• 제목/요약/키워드: Porcelain teeth

검색결과 99건 처리시간 0.022초

보철 수복시 치간 유두에 대한 고려 사항

  • 이성복;이승규
    • 대한심미치과학회지
    • /
    • 제10권1호
    • /
    • pp.30-45
    • /
    • 2001
  • In recent years, clinicians' and dentists' esthetic demands in dentistry have increased rapidly. The ultimate goal in modern restorative dentistry is to achieve "white" and "pink" esthetics in the esthetically important zones. Therefore, modern esthetic dentistry involves not only the restoration of lost teeth and their associated hard tissues, but increasingly the management and reconstruction of the encasing gingiva with adequate surgical techniques. Interdental space are filled by interdental papilla in the healthy gingiva, preventing plaque deposition and protecting periodontal tissue from infection. This also inhibits impaction of food remnants and whistling through the teeth during speech. These functional aspects are obviously important, but esthetic aspects are important as well. Complete and predictable restoration of lost interdental papillae remains one of the biggest challenges in periodontal reconstructive surgery. One of the most challenging and least predictable problems is the reconstruction of the lost interdental papilla. The interdental papilla, as a structure with minor blood supply, was left more or less untouched by clinicians. Most of the reconstructive techniques to rebuild lost interdental papillae focus on the maxillary anterior region, where esthetic defects appear interproximally as "black triangle". Causes for interdental tissue loss are, for example, commom periodontal diseases, tooth extraction, excessive surgical periodontal treatment, and localized progressive gingiva and periodontal diseases. If an interdental papilla is absent because of a diastema, orthodontic closure is the treatment of choice. "Creeping" papilla formation has been described by closing the interdental space and creating a contact area. In certain cases this formation can also be achieved with appropriate restorative techniques and alteration of the mesial contours of the adjacent teeth. The presence of an interdental papilla depends on the distance between the crest of bone and the interproximal contact point, allowing it to fill interdental spaces with soft tissue by altering the mesial contours of the adjacent teeth and positioning the contact point more apically. The interdental tissue can also be conditioned with the use of provisional crowns prior to the definitive restoration. If all other procedures are contraindicated or fail, prosthetic solutions have to be considered as the last possibility to rebuild lost interdental papillae. Interdental spaces can be filled using pink-colored resin or porcelain, and the use of a removable gingival mask might be the last opportunity to hide severe tissue defects.

  • PDF

수종의 인공 레진 치아의 마모저항성과 경도에 관한 비교 연구 (Comparative Study on Wear Resistance and Hardness of Several Artificial Resin Teeth)

  • 최유성;이준석;조인호
    • 구강회복응용과학지
    • /
    • 제24권2호
    • /
    • pp.129-146
    • /
    • 2008
  • 본 연구에서는 다양한 치과 수복재료에 대합되는 의치용 레진치의 마모저항성을 알아보기 위해 통상의 아크릴 릭 레진치인 $Trubyte^{(R)}$ $Biotone^{(R)}$ (Dentsply, U.S.A.)과 고강도 레진치인 Endura $Posterio^{(R)}$ (Shofu, Japan), Physio $Duracross^{(R)}$ (Nissin, Japan)를 수복재료인 금합금, 도재, 충전용 레진에 대합시켜 마모저항성을 비교 분석하였다. 또한 앞의 세 종류의 레진 인공치와 5종류의 의치세정제인 유한락스, 폴리덴트, 싸이덱스, 헥사메딘, 증류수를 사용하여 의치세정제 및 소독제가 경도에 미치는 영향을 비교 분석하여 다음과 같은 결과를 얻었다. 1. 대합되는 수복재료로 충전용 레진, 도재를 사용한 경우 $Trubyte^{(R)}$ $Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ 순으로 교두정 높이감소가 컸으며 세 재료간의 유의한 차이를 보였다 (p<0.05). 2. 대합되는 수복재료로 금합금을 사용한 경우 $Trubyte^{(R)}$ $Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ 순으로 교두정 높이 감소가 컸으며, 특히 $Trubyte^{(R)}$ $Biotone^{(R)}$ 이 다른 두 종류의 인공치보다 유의성 있게 높은 교두정 높이 감소를 보였다 (p<0.05). 3. 대합되는 수복재료로 충전용 레진, 금합금, 도재를 사용한 경우 모두 $Trubyte^{(R)}$ $Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ 순으로 무게 감소가 컸으며, 세 재료간의 유의한 차이를 보였다 (p<0.05). 4. 의치세정제에 따른 경도 감소는 실험 전과 후의 측정치를 비교했을 때 모든 레진 인공치에서 유의성 있는 차이 를 나타내었다 (p<0.05). 5. 유한락스, 싸이덱스, 헥사메딘에 담구었던 레진 인공치에 의한 경도감소는 $Trubyte^{(R)}$ $Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ 순으로 높은 감소를 보였고, 특히 $Trubyte^{(R)}$ $Biotone^{(R)}$이 다른 두 종류의 인공치보다 유의성 있게 높은 경도 감소를 보였다 (p<0.05). 이상의 실험 결과 마모저항성 실험에서는 최근에 개발된 Physio $Duracross^{(R)}$가 다른 두 종류의 레진 인공치에 비해 세 종류의 대합되는 수복재료 모두에서 높은 마모저항성을 보였고 특히 $Trubyte^{(R)}$ $Biotone^{(R)}$에 비해 유의성 있게 높은 마모저항성을 보였다. 경도 실험에서는 Physio $Duracross^{(R)}$와 Endura $Posterio^{(R)}$$Trubyte^{(R)}$ $Biotone^{(R)}$에 비해 유의성 있게 낮은 경도감소를 보였고 (p<0.05), 폴리덴트, 증류수에서는 유의한 차이를 보이지 않았다. 따라서, Physio $Duracross^{(R)}$가 세 종류의 레진 인공치에 비해 우수한 마모저항성을 보인다고 볼 수 있고, Endura $Posterio^{(R)}$와 함께 $Trubyte^{(R)}$ $Biotone^{(R)}$에 비해서 우수한 경도를 보인다고 볼 수 있지만, 단편적인 실험 결과이므로, 아직은 신중하게 고려되어야 하고, 더 많은 연구가 필요하다고 사료된다.

수종 도재 색조 선택 시스템의 spectrophotometer를 이용한 색조 재현성 평가 (THE REPRODUCIBILITY OF VARIOUS PORCELAIN COLOR SELECTION SYSTEMS USING SPECTROPHOTOMETRY)

  • 김이경;조인호;신수연
    • 대한치과보철학회지
    • /
    • 제42권5호
    • /
    • pp.544-555
    • /
    • 2004
  • Statement of problem: Shade selection has traditionally been accomplished by visual examination, which is particularly relevant to the shade selection of anterior teeth, but the subjective nature of visual analysis can lead to errors in shade matching. Recently shade selection systems have been developed to provide a more objective and scientific approach to understanding and clarifying shade selection. Purpose : The purpose of this study was analysis of various shade analyzing equipment with the goal of providing a more objective shade selection. Materials and method: Visual shade matching system selection(Vita Lumin Vacuum shade guide, Vitapan 3D Master shade guide) and mechanical shade matching method($ShadeEye^{(R)}$-EX Chroma Meter, $Shadescan^{TM}$ System) used for this study. The shade guide tap specimens for 10 extracted maxillary anterior teeth were produced by selecting shades using each shade matching system. The accuracy of the selection of shades for the teeth and fabricated specimens were evaluated by analyzing the calculated shade difference(${\Delta}E^*$), using a spectrophotometer and calculating the output of value $L^*,\;a^*,\;b^*$. Results and conclusion: The results show that the average ${\{Delta}E^*$ value (difference of shade) of the shade tap specimens to the actual specimen decreased in the following order: Vita Lumin Vacuum Shade Guide(VL), $ShadeEye^{(R)}$-EX Chroma Meter(SE) Vitapan 3D Master Shade guide(V3), and $Shadescan^{TM}$ System(55) : and that there are significant statistical differences between the VL and SS (p<0.05). In the analysis of the ${\Delta}E^*$ (difference of shade) value,40% of the VL group was found to be less than 3.3 (limit value of shade tap specimens clinically acceptable), 60% in the V3 group, 50% in the SE group, and 80% in the SS group.

쉽고 안전한 치아미백술 (Simple and Safe Tooth Bleaching)

  • 권소란
    • 대한심미치과학회지
    • /
    • 제8권1호
    • /
    • pp.64-74
    • /
    • 1999
  • The use of fluoride and other preventive methods caused a dramatic decline in dental caries and the need for restorative dentistry. In our modern society that places a high value on appearance, emphasis is now shifting towards esthetic dentistry which has experienced a high popularity with the development of bonding techniques and materials including porcelain and composite. To satisfy patients wanting whiter teeth and a better looking smile, there are many treatment options ranging from full crown coverage to conservative procedures such as bleaching. Whether bleaching should be combined with other esthetic procedures or used alone depends on the type of discoloration and the patient's willingness to accept the various treatment options. Therefore, in order to obtain a successful esthetic outcome, careful diagnosis and treatment planning followed by consultation with the patient is of utmost importance.

  • PDF

포스트의 종류에 따른 Empress 2 도재관의 색상에 관한 비교연구 (COLOR COMPARISON OF VARIOUS POST SYSTEMS WITH EMPRESS 2 CROWNS)

  • 이영수;유동엽
    • 대한치과보철학회지
    • /
    • 제39권2호
    • /
    • pp.197-207
    • /
    • 2001
  • Development of new ceramics and esthetic needs of patients increase the use of all ceramic restorations. Fractured teeth often need metal post and core as foundation for final restoration. When all ceramic restorations are planned, metal post and core may lead to compromised esthetics because of opacity and gray color of metal post and core. Many techniques have been proposed to solve this problem such as application of an opaque porcelain to the metal core or all ceramic post and core. This study was performed to evaluate effect on color of Empress 2 crown according to various post systems. Color was evaluated by the CIE $L^*a^*b^*$ systems and measured by spectrophotometer (Model CM-3500, Minolta, Japan). Specimens were divided into 4 groups as follows Group 1 : gold cast post specimen + Empress 2 crown specimen Group 2 : application of an opaque porcelain to gold cast post specimen + Empress 2 crown specimen Group 3 : cosmopost specimen + Empress 2 crown specimen Group 4 : In-ceram post specimen + Empress 2 crown specimen. The results obtained as follows, 1. $L^*$ Values showed that group 2, 3, 4 were higher than group 1 with significant difference and group 2, 3, 4 were not significantly different. 2. $a^*$ Values and $b^*$ values also showed that group 2. 3, 4 were higher than group 1 with significant difference and group 2, 3, 4 were not significantly different. 3. ${\Delta}E^* ab$ Values showed that ${\Delta}E^* ab$ 3 was the highest value and ${\Delta}E^* ab$ 5 was the lowest value.

  • PDF

CAD/CAM을 이용하여 제작한 전부도재관의 지르코니아 코핑 디자인에 따른 파절강도에 관한 연구 (A Study on the Fracture Strength of All-Ceramic Crown according to the Zirconia Coping Design using CAD/CAM System)

  • 로도이 볼강;조인호;신수연
    • 구강회복응용과학지
    • /
    • 제22권2호
    • /
    • pp.111-123
    • /
    • 2006
  • A Study on the Fracture Strength of All-Ceramic Crown according to the Zirconia Coping Design using CAD/CAM System L. Bulgan, In-Ho Cho, Soo-Yeon Shin Department of Prosthodontics, Graduate School, Dankook University The fracture strength of prosthesis is important, because it affects the function, and long term success of prosthesis and teeth. The purpose of this study was to compare the fracture strength of zirconia coping designs. Experimental test group were classified into three designs according to coping design, Modified design: Zirconia coping margin was located at 1mm above the axiogingival line angle. Collarless design: The coping margin terminated at the axiogingival line angle Butt design: The coping margin was extended to the finishing line of prepared margin. A $Cercon^{(R)}$(Degussa, Germany) CAD/CAM system was used to make the zirconia coping. Fracture strength was measured using loading machine at a cross head speed of 1mm/min. The results were statistically analyzed using the one-way ANOVA and multiple comparison test. Statistical significance was set in advance at the probability level of less than 0.05. The result : I. Collarless($738N{\pm}155N$) and Modified($755N{\pm}185N$) groups showed significantly a lower fracture strength than Butt($1057N{\pm}262N$) group(p<0.05). II. There were no statistical differences of the fracture strength between Modified($755N{\pm}185N$) and Collarless($738N{\pm}155N$) groups. III. When comparing the fractured surface, all the group showed porcelain fracture, which were fractured at the labial surface of baked porcelain The butt design of the zirconia coping has higher fracture strength than modified and collarless design.

THE COLOR STABILITY OF AESTHETIC RESTORATIVE MATERIALS RESULTING FROM ACCELERATED AGING

  • Lee, Jeong-Seon;Suh, Kyu-Won;Ryu, Jae-Jun
    • 대한치과보철학회지
    • /
    • 제46권6호
    • /
    • pp.577-585
    • /
    • 2008
  • STATEMENT OF PROBLEM: The discoloration of anterior teeth restoration is one of the material problems demanding retreatment. OBJECTIVES: To evaluate the color stability and affecting factors on esthetic restorative materials when subjected to accelerated aging. MATERIAL AND METHODS: This study was conducted using porcelain disks (IPS Empress 2-glazed, IPS Empress 2-polished), direct restorative resin disks (SYNERGY Duo) and indirect restorative resin disks (Sinfony, TESCERA ATL). Accelerated aging was done by precipitating the specimens in 38.C distilled water and irradiating with xenon light, and the total irradiation was 397.98 KJ/mm. Color and microhardness change of the specimens were measured before accelerated aging and after 100 hours, 200 hours and 300 hours of accelerated aging, and Surface of the specimens were examined with SEM before and after 300 hours of accelerated aging. RESULTS: 1. After 300 hours' accelerated aging, a ${\Delta}E$ value was 3.3 or lower in IPS Empress 2-glazed, IPS Empress 2-polished and Sinfony. 2. After 300 hours' accelerated aging, gloss was lost and surface changes including microcracks were observed in TESCERA ATL and SYNERGY Duo, and color changes of them ranged between 3.58 and 6.40 ${\Delta}E$ units. 3. During 300 hours' accelerated aging, the microhardness of surface was increased by 3.21 - 19.64% in all kinds of composites resin. CONCLUSION: After 300 hours' accelerated aging, SEM images IPS Empress 2-glazed, IPS Empress 2-polished and Sinfony showed little morphological change and their color changes were considered to be clinically acceptable. And there was significant correlation between microhardness changes and color changes of composites (P < .05).

금속의 두께가 도재의 파절강도에 미치는 영향 (A study on the difference of Ceramic fracture strength according to the metal depth)

  • 신무학;최운재;김용원
    • 대한치과기공학회지
    • /
    • 제27권1호
    • /
    • pp.89-95
    • /
    • 2005
  • In the manufacture of ceramo-metal crown, difference of fracture strength according to the metal depth has been known to be an important influence on enough intensity and internal stress to endure an occlusion-pressure as well as aesthetics of rehabilitating similar colour such as natural teeth. Depth of ceramic material could be determined by that of metal in three groups: first case of thin depth, second case of thick depth, and third case of constant depth. For the enhancement of the fracture strength between metal and ceramic materials and aesthetic satisfaction, a study on the bonding force, fracture strength, and aesthetics have been required more. In this study, therefore metal coping were made in three groups of A, B and C by using both ceramic powder of Norithe and metal of Columbium, which have been used primarily in the market. A group was made in $0.2mm\times10mm\times10mm$, B group was made in $0.4mm\times10mm\times10mm$, and, C group was made in $0.8mm\times10mm\times10mm$, respectively. The number of metal coping in each group was 10, and total sample numbers used in this study were 30 metal copings. After these metal coping tissue were in the process of build-up in 1.5mm constant depth of porcelain, firing, and glazing, the fracture strength about each metal coping tissue was investigated using oil press. It was found that the average values of durable occlusion pressure for separation of ceramic material in the porcelain fused to metal crown (PFM) in the each group showed the increasing order of A group (30 bar), B group (42 bar), and C group (44 bar), respectively. Proper depth of metal coping in the PFM was considered to be 0.4mm in the B group because this metal size showed higher durable property to the occlusion pressure and better coupling strength in the ceramo-metal crown.

  • PDF

보철물 조건에 따른 Periotest수치의 실험적 평가 (IN VITRO EVALUATION OF PERIOTEST VALUES UNDER VARIOUS CONDITIONS OF PROSTHESES)

  • 한중석
    • 대한치과보철학회지
    • /
    • 제35권4호
    • /
    • pp.793-800
    • /
    • 1997
  • Periotest(Siemens, Germany) has been used to test mobility of the implants clinically, however the effects of target materials and connection methods on the PTVs(Periotest Values) have not been evaluated. Periotest has been regarded as a reliable and objective tool to test implant and natural teeth mobility clinically, however this instrument showed different PTVs under various test conditions. This in vitro study was designed to compare PTVs of different veneering materials and prosthodontic designs (single and bridge restorations). To compare the effects of veneering materials on PTVs, 1 mm thickness of five different testing materials (porcelain, type III gold alloy, pure titanium, composite resin, acrylic resin) were placed on the resin block. Three full length of 13 mm Mark II implant fixtures were embedded into autopolymerizing resin block to fabricate single and bridge restorations. To evaluate effects of the connection method in single restorations, PTVs of screw retained(UCLA type) and cementation type(Cera-One system) were compared. Finally, to test reliability of PTVs of the final restorations, screw retained three unit short span PFM bridges were fabricated on the standard and Estheti-Cone abutments. All testing components were tightened with torque controller and PTVs of all specimens were measured 15 times for statistical analysis with SAS program. Following conclusions were made within the limit of this in vitro study. 1. PTVs of type III gold alloy, grade II titanium, composite resin veneering materials showed no significant differences, however acrylic resin and porcelain showed significant differences (P<0.05). 2. Single tooth restorations showed consistent PTVs as long as proper torque force was applied. 3. PTVs of bridge type prostheses was inconsistent regardless of abutment types. 4. PTVs of the prostheses showed higher scores and standard deviations than those of abutments regardless types of connection (P<0.05).

  • PDF

Evaluation of two interforaminal implants and implant-assisted removable dentures on stress distribution: an in vitro study

  • Bilhan, Selda Arat;Geckili, Onur;Cilingir, Altug;Bozdag, Ergun;Bilhan, Hakan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제45권4호
    • /
    • pp.199-206
    • /
    • 2019
  • Objectives: In mandibular edentulism, the treatment option with a two-interforaminal implant-retained bridge and a removable partial denture is rarely evaluated in literature. The aim of this in vitro study was to evaluate the stress distribution of this treatment option by comparing it with traditional treatment options with interforaminal implants in the edentulous mandible. Materials and Methods: Two interforaminal implants were placed in a formalin-fixed cadaver mandible, and overdentures with three different types of attachments were fabricated: (1) two ball attachments and an overdenture, (2) a Dolder bar and an overdenture, and (3) screw-retained two-implant inter-canine porcelain fused to a metal bridge and an implant-assisted removable denture (IARD) with precision attachments. Three biting conditions were generated for each denture type, and the strains were documented under vertical loading of 100 N. Results: The calculated strain values from measured strains in all measurement sites and loading conditions for the screw-retained two-implant intercanine porcelain fused to a metal bridge and a cast framework partial denture with precision attachments situation were lower than in the other scenarios (P<0.05). Conclusion: Within the limitations of the present study, it can be concluded that an IARD may be a reasonable and valuable alternative to ball attachments or a bar in two interforaminal implants, especially when the patients prefer to be able to show their teeth even when they take out their removable dentures.