• 제목/요약/키워드: Porcelain insulators

검색결과 125건 처리시간 0.026초

초고압 현수애자의 Pin 형상에 따른 응력해석 (The Temperature Distribution Analysis and Temperature Rise Test of Pole Mold Transformer)

  • 조한구;박기호;한세원;윤문수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.155-157
    • /
    • 2001
  • Various types suspension insulators made of toughness glass or porcelain are used in the power transmission. And, Insulators are continually subject to mechanical and electrical stresses which depend on the characteristics of the line. The main factor that influence the increase in reliability of insulators. In operation is the capacity of the design to withstand the certain load over a long time, the mechanical strength of the insulators. This paper describes the results of a study on the stress analysis of suspension insulator based on the finite element analysis using NASTRAN. And, the mechanical strength was evaluated through such as kinds of pin type.

  • PDF

외산 154kV NGK 노후애자의 전기적 성능 평가 (A Study on the Electric Performance of NGK Porcelain Insulators for long period use in 154kV Transmission Line)

  • 최인혁;박현민;원경배;강동훈;신구용;김영홍;김민주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.426-428
    • /
    • 2015
  • The NGK suspension insulators are subjected in harsh environments in service above 40 years long time. The long term reliability of the insulators is required for both mechanical and electrical performances. This study describes some electrical performances according to KEPCO-standard. There was fail in electrical and mechanical performance test such as galvanizing, low-frequence wet flashover voltage, puncture and combine mechanical & electrical strength test. The NGK suspension insulators of 1968 were shown lower electrical and mechanical performance than those of 1979.

  • PDF

비용해성 산업용 분진이 배전용 자기제 현수애자의 전기적 특성에 미치는 영향 (The Effect of the Non Soluble Industrial Dust on the Electrical Properties of Distribution Porcelain Suspension Insulators)

  • 김찬영;송일근;김주용;한재홍;김동명;이병성
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권4호
    • /
    • pp.182-189
    • /
    • 2001
  • In this paper, the distribution suspension porecelain insulators which had been used for long periods in the contaminated area were evaluated. The contaminated area is close to the sea and in the high density of industries. The heavily contaminated domestic and imported insulators were investigated by using electrical characteristics, such as power-frequency dry flashover voltage, power-frequency wet, flahover voltage, and leakage current. Also, these electrical results were compared with the contaminants on the surface. From these analysis, we found that the contamination from the industrial dust, only slightly decreased flashover voltage and increased leakage current. Therefore, the electrical properties of insulators used for 30 years in the area of coast and industrial complex were not much changed.

  • PDF

폴리머 LP애자의 설계해석과 전기적 성능 시험 (The Design Analysis and Electrical Performance Test of Polymer LP Insulator)

  • 이운용;조한구;박상호;송홍준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.399-401
    • /
    • 2000
  • Recently polymer insulators are being used for outdoor high voltage applications. Polymer insulators for transmission and distribution line have significant advantages over porcelain and glass insulators, especially for ultra-high voltage(UHV) transmission lines. Their advantages are light weight, vandalism resistance and hydrophobicity. In this paper, polymer line post insulator has been designed and investigated electric field distribution by FEM. Designed LP insulators have been tested as insulator performance test, such as power frequency voltage test, lightning impulse voltage test, artificial pollution test and flexural load test.

  • PDF

실 포설 환경에 노출된 송전용 고분자애자의 평가 (Analysis of Polymeric Insulators Exposed to In-service Conditions)

  • 이상진;연복희;배경무;전승익
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.248-250
    • /
    • 2004
  • We have investigated the surface state of 154kV polymeric insulators exposed to in-service conditions for about five years. In order to evaluate surface aging of silicone rubber exposed to real field environments, we used various analytic methods such as contact angle, ATR-FTIR, SEM-EDS. Although contaminants were accumulated on weathershed surface, polymeric insulator has retained its intrinsic surface hydrophocity. In addition, ATR-FTIR confirmed the diffusion layer of a low molecular weight silicone fluid on surface layer and no surface cracking and chalking were Indicated by SEM. Polymeric insulators have still retained their improved pollution performance over porcelain insulators. That will lead to very low frequency of flashovers throughout their useful life, often under contaminated conditions.

  • PDF

애자류의 염해대책에 관한 기초연구 (A basic study on preventing insulators from salt accident)

  • 김원섭
    • 전기의세계
    • /
    • 제18권1호
    • /
    • pp.11-14
    • /
    • 1969
  • This paper shows experimentally one method of preventing porcelain insulators from salt accident likely to be caused in the region of sea coast. In this experiment some results that, if a conductor barrier is inserted into the flash over discharge path which is wetted by salt dissolved water, the flash over voltage found to be raised up, were gotten. This results may be actually applied to suspension insulator or bushing to prevent them from salt accidents.

  • PDF

송전선용 현수애자 양생공정에서 발생하는 접착부의 응력변화 (Stress Response of Cement Interface on Manufacturing Process of a Suspension Insulator)

  • 우병철;한세원;조한구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1448-1450
    • /
    • 2003
  • The suspension insulators are subjected to harsh environment in service for a long time. Long term reliability of the insulators is required for both mechanical and electrical performances. We studied an analysing method to find out a deformation of brittle porcelain with a thermal expansion of simulation analysis and experimental results show that cement volume growths affect severely to be mechanical failure ageing.

  • PDF

송전용 폴리머애자의 산불 영향 신뢰성 평가 (Reliability Assessment of Forest Fire on EHV Polymer Insulator Strings)

  • 민병욱;신태우;최인혁;최한열;박재웅;유근양
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.436-437
    • /
    • 2006
  • Porcelain insulators have generally been used in Korea but polymer insulators which are superior in that they are light weight, explosion proof, impact proof, economical with construction characteristics, have been in use for the 154kV transmission line since 1999 following a worldwide trend towards the reduced weight, simplification and compact usage of new material insulators. However there have been approximately 500 cases of forest fires in Korea, so the transmission lines that for the most part pass through mountainous areas have been highly effected and the highly polymerized compound polymer insulator has raised concern about reliability in cases of exposure to forest fires. Therefore for the reliability assessment of the effect of forest fires on polymer insulators, mechanical and electrical characteristics are analyzed by an artificial flare test device and transmission facility surrounding conditions along with forest fire characteristics are surveyed. In addition to this, actual 90kV energized transmission line was tested with an artificial forest fire and the expanded usage of polymer insulators is presented through the analysis of mechanical and electrical characteristics and physical properties, and a study on the influence of forest fires on polymer insulators.

  • PDF

A Review of the Flashover Performance of High Voltage Insulators Constructed with Modern Insulating Materials

  • Khatoon, Shabana;Khan, Asfar Ali;Singh, Sakshi
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권5호
    • /
    • pp.246-249
    • /
    • 2017
  • Pollution flashover of outdoor insulators is a common risk, which affects the safe operation of overhead transmission networks. Early electrical power systems, which feature insulators made from ceramic materials have been used all over the world with good performance. At present, non-ceramic insulators are in common use, as a result of their good electrical as well as mechanical properties. The aim of this paper is to discuss and compare the flashover performance of insulators typically used in power lines, such as, porcelain, ethylene-propylene-diene-monomer (EPDM) rubber, room temperature vulcanized (RTV) and high temperature vulcanized (HTV) coated silicone rubber. The effect of various parameters, including the severity of pollution, ice accumulation, and shade profile, are considered.. From the studies reviewed it was concluded that there is a distinct difference in the flashover voltages of different types of insulators, and the silicone provides the best flashover performance of all insulating materials.

AE기법을 이용한 자기애자의 손상 분석 (Analysis on Damage of Porcelain Insulators Using AE Technique)

  • 최인혁;신구용;임윤석;구자빈;손주암;임대연;오태근;윤영근
    • 한국전기전자재료학회논문지
    • /
    • 제33권3호
    • /
    • pp.231-238
    • /
    • 2020
  • This paper investigates the soundness of porcelain insulators associated with the acoustic emission (AE) technique. The AE technique is a popular non-destructive method that measures and analyzes the burst energy that occurs mainly when a crack occurs in a high-frequency region. Typical AE methods require continuous monitoring with frequent sensor calibration. However, in this study, the AE technique excites a porcelain insulator using only an impact hammer, and it applies a high-pass filter to the signal frequency range measured only in the AE sensor by comparing the AE and the acceleration sensors. Next, the extracted time-domain signal is analyzed for the damage assessment. In normal signals, the duration is about 2ms, the area of the envelope is about 1,000, and the number of counts is about 20. In the damage signal, the duration exceeds 5ms, the area of the envelope is about 2,000, and the number of counts exceeds 40. In addition, various characteristics in the time and frequency domain for normal and damage cases are analyzed using the short-time Fourier transform (STFT). Based on the results of the STFT analysis, the maximum energy of a normal specimen is less than 0.02, while in the case of the damage specimen, it exceeds 0.02. The extracted high-frequency components can present dynamic behavior of crack regions and eigenmodes of the isolated insulator parts, but the presence, size, and distribution of cracks can be predicted indirectly. In this regard, the characteristics of the surface crack region were derived in this study.