• Title/Summary/Keyword: Porcelain insulators

Search Result 125, Processing Time 0.029 seconds

A Study on Measurement of ESDD and Contamination Performance of Polymeric Outdoor Insulators (옥외용 절연체 표면에서의 ESDD 측정과 내오손특성에 관한 연구)

  • 연복희;유형철;이현진;송정용;이태호;허창수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.427-430
    • /
    • 2002
  • This paper presents on contamination performance of polymeric outdoor insulator with different contaminant accumulation. The ESDD (equivalent salt deposit density), tracking resistance and clean-fog test were performed to investigate the characteristics of contamination performance on polymeric outdoor insulator. Furthermore, we evaluated together with the porcelain samples for its comparison. It is found that ESDD of polymeric and porcelain insulator depends on the installation position. This surface accumulation of contaminant lead to the loss of surface hydrophobicity, expecially upper shed part of polymeric insulator. In addition, the effect of an artificial contaminant on the tracking resistance by inclined-plane method and leakage suppression ability under clean fog was surveyed. The time of tracking failure did not appear to change significantly with a much contaminant accumulation, while leakage current under clean-fog increased.

  • PDF

Dead-end/Suspension Composite Insulator for Overhead Distribution Lines (신소재를 적용한 배전용 폴리머 현수애자의 평가 기술)

  • Soh, Jin-Joong;Kim, In-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1490-1492
    • /
    • 2001
  • Recently polymer composite materials has been replacing the porcelain in suspension insulators as a insulating material. The polymer composite materials are introduced into Korea from the abroad, so there is, actually, no formal standard of assessment Both the porcelain insulator specifications and composite material test specifications are being used at the same time. The aim of this project is to establish a systematic standard suitable to current situations considering the trends of its production within Korea. This would protect the inner-markets against the market-opening and would promote the industrial development within a country.

  • PDF

Aging Properties from Forest-fire Simulated Acceleration of Porcelain Insulators for Transmission Line (송전용 애자의 산불 복합가속열화 특성)

  • Han, Se-Won;Choi, In-Hyuk;Lee, Dong-Il;Lee, Won-Kyo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.114-114
    • /
    • 2010
  • 산불에 노출되는 경우 열충격으로 작용하는 패턴과 특성을 검토하여 가속열화시험에 반영하는 것이 필요하다. 본 연구에서는 산불환경을 모의하여 복합열화시험을 실시하기위해 복합가속열화 챔버를 구축하였다. 온도는 주로 $200^{\circ}C$에서 최대 $1000^{\circ}C$까지 변화를 주면서 예비시험과 본시험 실하였다.

  • PDF

A Studies on Aging Properties for Transmission Line Polymer Insulators which are Installed in service (실계통에 포설된 송전용 고분자 애자의 AGING 특성 연구)

  • Kim, So-Yeon;Lee, Sang-Jin;Ha, Young-Kil;Kim, Dong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.152-154
    • /
    • 2001
  • Recently the extensive use of composite insulators for transmission lines can ultimately be justified only on long-term qualification tests. Especially, it is possible for the Polymer insulator to be aged in according to the environment in which it is used this may bring about the decrease of the duration of voltage application. So, this paper deals with aging property of the polymer insulator installed at real transmission line in the industry area. The contact angle, arc test, tracking test were measured for acquiring the degradation characteristics of silicone rubber and the SEM, XRF, FT-IR tests were measured for analyzing the crack and components. Also the surface leakage current of the polymer insulator was compared with that of the porcelain insulator. Finally, we knew that the aging property was not appeared during seven months at real transmission line in the industry area.

  • PDF

A Study on the Ultraviolet Aging Characteristics of Outdoor Polymeric Insulating Materials (옥외용 고분자 절연재료의 자외선 열화특성 연구)

  • Kim, Yeong-Seong;Jeong, Sun-Ok
    • Korean Journal of Materials Research
    • /
    • v.9 no.4
    • /
    • pp.409-413
    • /
    • 1999
  • Recently, the polymeric insulators have been accepted in several countries for the outdoor high voltage applications. In comparison with the conventional porcelain, polymeric insulators offer various advantages such as light weight, superior vandal resistance and better contamination performance. The outdoor polymeric insulating materials such as silicone rubber, ethylene propylene diene monomer(EPDM), ethylene vinyl acetate(EVA) and epoxy are aged such as silicone rubber, ethylene propylene diene monomer(EPDM), ethylene vinyl acetate(EVA) and epoxy are aged under the various natural environment with the long-term performance in outdoor. In this paper, the effects of UV-under the various natural environment with the long-term performance in outdoor. In this paper, the effects of UV-ray on the surface of silicone rubber were investigated by using the weather-Ometer. The accelerated aging stresses were simulated by UV radiation, high temperature and humidity as well as water spray. These aging characteristics were examined through contact angle measurements, tracking resistance test, FT-IR and SEM/EDS analysis. The experimental results showed that tracking resistance decreases with increase in the UV-ray irradiation period. But the surface of silicone rubber kept hydrophobicity. It is found that the inorganic filler such as)$ Al(OH_3$ improves tracking resistance and the $Tio_2$is very effective in preventing degradation of silicone rubber surface from UV-ray.

  • PDF

The research for the application of polymer support insulator used in DC railway system (직류전기철도에서의 고분자 지지애자 적용에 관한 연구)

  • Lee, Gi-Sung;Kim, Yoon-Sik;Sim, Jae-Suk;Jung, Ho-Sung;Lee, Ki-Won;Cho, Ho-Ryung
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.371-377
    • /
    • 2009
  • The use of polymer insulator has increased all over the world. As of 2000's KEPCO has used it fully since they introduced it in early 1990's. In Korea it is very widely used by KORAIL which uses AC 25 kV system in the ground electric car line. And It is also used in tunnel electric car line to support AT feeder line. But it has not been used in the section of DC 1500 V. In case of DC 1500 V electric railway system It is has been developed by research institutes by means of R&D projects since 2008. The user cleans porcelain insulators regularly by water because of dusts and pollution. In case of polymer insulators It is very easy to be made dirty by pollution because of the material properties and hard to be cleaned by cleansing. In accordance with these reasons It is worried about deterioration. This paper deals with anticipating problems when we apply it to DC electric railway system and the procedure for testing polymer support insulator.

  • PDF

Magnetite Crystallization in Semiconducting Glaze Frit for High Tension Electric Insulators (고전압 애자용 반도성 유약프리트에서의 Magnetite 결정화)

  • 이희수;이동인;전병세
    • Journal of the Korean Ceramic Society
    • /
    • v.20 no.4
    • /
    • pp.333-339
    • /
    • 1983
  • Semiconducting glaxe of iron system for the recent use as high Voltage porcelain insulators often showed the tendancy of unstable thermal properties. Thus the development of frit including magnetite was studied to cover the defect. In the experimental process melted and quenched frits were ground pelletized and heat-treated at various temperatures in the range of 800-1 $300^{\circ}C$ for various soaking time within 4 hours and then crystallized specimens were obtained. The speciment were studied with optical and electron microscope DTA x-ray diffractometer and electrometer The results obtained were as follows : 1) The optimum condition for the crystal growth of magnetite in the frite was the heat-treatment of $1300^{\circ}C$ for 3hrs and in this case the range of crystal size was $10-11\mu\textrm{m}$ 2) The activation energy for the crystal growth of magnetite was 21.1 kcal/mole. 3) The heat-treament at $1, 250^{\circ}C$ and $1, 300^{\circ}C$ resulted in the good thermal stability and the range of surface resistivity was $3.5{\times}10^4-4.0{\times}10^7$, /TEX> $\Omega$/$cm^2$ which was adguate to semiconducting frit. 4) The conduction mechanism seems to be due to the electron mobility rather than ion mobility and the activa-tion energy for the conduction was 0.07-0.15eV/mole for the heat-treated specimes in the range of 1, 250-1, 300C

  • PDF

Surface and Tracking Properties of Polymer Suspension Insulator for Power Transmission with secular variation (경년열화에 따른 송전용 폴리머 현수애자의 표면 및 트래킹 성능)

  • Cho, Han-Goo;Lee, Un-Yong;Han, Se-Won;Han, Dong-Hee;Huh, Jong-Chul;Choi, In-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.233-236
    • /
    • 2004
  • Recently, the polymer insulators that are used for high voltage applications have some advantages such as light weight, small size, vandalism resistance, hydrophobicity and easy making process. During outdoor service of polymer insulators, the surface of the insulating material is frequently subjected to moisture and contamination that lead to dry band arcing. Their tracking resistance, erosion resistance, end sealing and shed design are very important because dry band arcing causes degradation of polymer surface. The shape design of porcelain insulator is formalized but design standard for polymer insulator is no standardized up to now, much research is necessary in real condition. In this paper, the surface and tracking properties of polymer suspension insulator for power transmission is investigated with ICP-AES, SEM, EDX, tracking wheel test and flashover voltage test. The diagnosis of insulator sample in tracking test hass been analyzed by leakage current STRI Guide and thermal image.

  • PDF

Effects of Non-uniform Pollution on the AC Flashover Performance of Suspension Insulators

  • Zhijin, Zhang;Jiayao, Zhao;Donghong, Wei;Xingliang, Jiang
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.961-968
    • /
    • 2016
  • The non-uniform distribution of contamination on insulator surface has appreciable effects on flashover voltage, and corresponding researches are valuable for the better selection of outdoor insulation. In this paper, two typical types of porcelain and glass insulators which are widely used in ac lines were taken as the research subjects, and their corrections of AC flashover voltage under non-uniform pollution were studied. Besides, their flashover characteristics under different ratio (T/B) of top to bottom surface salt deposit density (SDD) were investigated, including the analysis of flashover voltage, surface pollution layer conductivity and critical leakage current. Test results gave the modified formulas for predicting flashover voltage of the two samples, which can be directly applied in the transmission line design. Also, the analysis delivered that, the basic reason why the flashover voltage increases with the decrease of T/B, is due to the decrease of equivalent surface conductivity of the whole surface and the decrease of critical leakage current. This research will be of certain value in providing references for outdoor insulation selection, as well as in proposing more information for revealing pollution flashover mechanism.

Performance of Polymer Suspension Insulator with Shed Profile (갓 형상에 따른 폴리머 현수애자의 열화특성)

  • Cho, H.G.;Lee, U.Y.;Kang, S.H.;Lim, K.J.;Yeo, H.G.;Ji, W.Y.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.539-542
    • /
    • 2003
  • Recently, the polymer insulators which are being used for high voltage applications have some advantages such as light weight, small size, vandalism resistance, hydrophobicity and easy making process. During outdoor service of polymer insulators, the surface of the insulating material is frequently subjected to moisture and contamination which lead to the well known phenomenon of dry band arcing. Their tracking resistance, erosion resistance, end sealing and shed design are very important because dry band arcing causes degradation of polymer surface. The shape design of porcelain insulator is formalized but design standard for polymer insulator is no standardized up to now, much research is necessary in real condition. In this paper, the aging property of polymer insulator with shed shape(regular, alternative type) is analyzed through numerical analysis, CEA(canadian electricity association) tracking wheel test and IEC 61109 Annex C.

  • PDF