• Title/Summary/Keyword: Poor contact

Search Result 220, Processing Time 0.024 seconds

A Study for Failure Examples Including with Engine Oil Leakage, Poor Contact by Fin Damage and Vaporizer Inferiority on LPG Automotive (LPG 자동차의 엔진오일누설, 핀 손상에 의한 접촉불량, 베이퍼라이저 내부불량으로 인한 고장사례연구)

  • IL Kwon, Lee;Chang Ho, Kook;Sung Hoon, Ham;Seung Yong, Lee;Jae Gang, Lee;Seung Min, Han; Woo Chan, Hwang;Dae Cheon, Jang;Chang Bae, You;Jeong Ho, Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.6
    • /
    • pp.24-29
    • /
    • 2022
  • This paper is a purpose to Analyze and study the failure examples for a engine oil leakage of camshaft bearing seal, poor contact by computer connector fin damage and vaporizer inferiority on LPG automotive. The first example, when the researcher disassembled the cylinder head of engine to establish the cause for oil leakage, he confirmed the engine oil leakage by damaged between the engine intake camshaft bearing and seal part. The second example, the connector fin of power source line that control the starting of a car supplied with engine computer. As a result, it found the fact that the engine operation stopped because of cutting of the power source by connector fin damage. The third example, it verified the engine incongruity phe cutting of the power source by connector fin damage. The third example, it verified the engine incongruity phenomenon as thd gas didn't flow the vaporizer by foreign substance deposit. Finally, it supplied a small quantity gas from vaporizer to mix. As the computer controlling mix opening condition supplied a air as opening signal, the air and fuel became rarefied state. it knew that the engine didn't produce prpper power. Therefore, a car have to throughtly inspect not in order to arise the failure symptoms.

Method of Biological Information Analysis Based-on Object Contextual (대상객체 맥락 기반 생체정보 분석방법)

  • Kim, Kyung-jun;Kim, Ju-yeon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.41-43
    • /
    • 2022
  • In order to prevent and block infectious diseases caused by the recent COVID-19 pandemic, non-contact biometric information acquisition and analysis technology is attracting attention. The invasive and attached biometric information acquisition method accurately has the advantage of measuring biometric information, but has a risk of increasing contagious diseases due to the close contact. To solve these problems, the non-contact method of extracting biometric information such as human fingerprints, faces, iris, veins, voice, and signatures with automated devices is increasing in various industries as data processing speed increases and recognition accuracy increases. However, although the accuracy of the non-contact biometric data acquisition technology is improved, the non-contact method is greatly influenced by the surrounding environment of the object to be measured, which is resulting in distortion of measurement information and poor accuracy. In this paper, we propose a context-based bio-signal modeling technique for the interpretation of personalized information (image, signal, etc.) for bio-information analysis. Context-based biometric information modeling techniques present a model that considers contextual and user information in biometric information measurement in order to improve performance. The proposed model analyzes signal information based on the feature probability distribution through context-based signal analysis that can maximize the predicted value probability.

  • PDF

Inspection of Welded Zone and Flat Plate Using Flexible ECA Probe (Flexible ECA Probe를 이용한 평판 및 용접부 검사)

  • Lee, Chang-Jun;Lee, Kyu Sung;Shin, Chung-Ho;Lee, Kyoung-Jun;Jang, Yoon Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.4
    • /
    • pp.288-294
    • /
    • 2016
  • This paper aims to compare the ability to detect notch defects existing in the plate and welded area using a flexible ECA (eddy current array) probe with OmniScan MX and MS-5800E. The characteristics of signals with various frequencies and lift-offs were also compared. As a result, when signals of frequencies 500, 1000, and 1500 kHz were used, the amplitude of the signal increased, as the depth of the notch increased, but reduced linearly in accordance with the lift-off variation. In addition, the detection sensitivity of the weld defect was found to be closely related to the contact surface of the probe and specimen. In this paper, it was demonstrated that the detection sensitivity was excellent when the contact surface of the probe and the specimen was sufficient, but it was poor when the contact surface was insufficient.

A Study to Improve PEMFC Performance by Using Electro Polishing and CrN Coating on Metal Bipolar Plate (금속분리판의 Electro Polishing 및 CrN 코팅을 통한 PEMFC 성능 향상을 위한 연구)

  • Hwang, Sung Tack;Cheon, Seung Ho;Song, Jun Seok;Yun, Young-Hoon;Kim, Byeong Heon;Zhang, Xia;Kim, Dae-Ung;Hyun, Deoksu;Oh, Byeong Soo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.4
    • /
    • pp.65-71
    • /
    • 2014
  • As an important component of a fuel cell, the bipolar plate comprises a large proportion in the fuel cell's volume, weight and price. The bipolar plate is the most widely used; however, graphite bipolar plate is large in volume, brittle and therefore easily broken during assembling. In addition, due to its poor machinability, production costs a lot, unless mass production. Compared with the graphite bipolar plate, the metal bipolar plate has good machinability, high electric conductivity and strong mechanical strength; however, it corrodes easily and has a high contact resistance, so in order to prevent corrosion and reduce the contact resistance, the basic metal needs to be processed by use of electro polishing and coating. The water which is produced by electrochemical reactions in the fuel cell must be discharged smoothly. In this study, in order to prevent corrosion the processes of electro polishing and CrN coating were used. According to the presence or absence of these processes, the contact angles can be measured and different metal bipolar plates can be made, these plates can be used for comparing and analyzing the performance of the fuel cell.

Development of the Large-area Au/Pd Transfer-printing Process Applying Both the Anti-Adhesion and Adhesion Layers (접착방지막과 접착막을 동시에 적용한 대면적 Au/Pd 트랜스퍼 프린팅 공정 개발)

  • Cha, Nam-Goo
    • Korean Journal of Materials Research
    • /
    • v.19 no.8
    • /
    • pp.437-442
    • /
    • 2009
  • This paper describes an improved strategy for controlling the adhesion force using both the antiadhesion and adhesion layers for a successful large-area transfer process. An MPTMS (3-mercaptopropyltrimethoxysilane) monolayer as an adhesion layer for Au/Pd thin films was deposited on Si substrates by vapor self assembly monolayer (VSAM) method. Contact angle, surface energy, film thickness, friction force, and roughness were considered for finding the optimized conditions. The sputtered Au/Pd ($\sim$17 nm) layer on the PDMS stamp without the anti-adhesion layer showed poor transfer results due to the high adhesion between sputtered Au/Pd and PDMS. In order to reduce the adhesion between Au/Pd and PDMS, an anti-adhesion monolayer was coated on the PDMS stamp using FOTS (perfluorooctyltrichlorosilane) after $O_2$ plasma treatment. The transfer process with the anti-adhesion layer gave good transfer results over a large area (20 mm $\times$ 20 mm) without pattern loss or distortion. To investigate the applied pressure effect, the PDMS stamp was sandwiched after 90$^{\circ}$ rotation on the MPTMS-coated patterned Si substrate with 1-${\mu}m$ depth. The sputtered Au/Pd was transferred onto the contact area, making square metal patterns on the top of the patterned Si structures. Applying low pressure helped to remove voids and to make conformal contact; however, high pressure yielded irregular transfer results due to PDMS stamp deformation. One of key parameters to success of this transfer process is the controllability of the adhesion force between the stamp and the target substrate. This technique offers high reliability during the transfer process, which suggests a potential building method for future functional structures.

Investigation of Low Velocity Impact Behavior of Laminated Composite Plates Considering the Stacking Method (적층방법에 따른 복합적층판의 저속충격거동 조사)

  • Kim, Seung-Deog;Kwon, Suk-Jun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.4
    • /
    • pp.75-83
    • /
    • 2010
  • Laminated composite plates have shown their superiority over metals in applications requiring high specific strength, high specific modulus, and so on. Therefore, they have used in various industry. However, they have poor resistance to impact compared to typical metal materials. So, many researchers have investigated about impact behavior of laminated composite plate. To investigate impact behavior of laminated composite plate, we have to calculate contact force between impactor and laminated composite plate at the first. Impactor's equation of motion, plate's equation of motion and correlations for indentation were solved to know the contact force at the same time. In this study, low velocity impact behavior of composite plate was investigated using the finite element program which is involved the classical Hertzian law, Sun's law and Sun & Yang's experimental law and Sun & Tan's experimental law considering the stacking method.

  • PDF

Analysis of Axial Mis-alignment After Wearing of Toric Soft Contact Lenses (토릭소프트콘택트렌즈의 착용 후 축 정렬 상태의 변화 분석)

  • Kim, Sang-Yoeb;Lee, Dong Yeol;Lee, Sun-Haeng;Kim, Kun-Kyu;Song, Sop;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.213-217
    • /
    • 2010
  • Purpose: To emphasize the necessity of post-fitting by follow-up test, the mis-alignment was analyzed after initial wearing of toric soft contact lenses (TSCL). Methods: After trial contact lenses were worn to 87 eyes with myopic astigmatism for 1 week, we observed the alignment of axis mark on trial contact lenses using slit lamp and corrected the rotated axis by method of LARS. After final fitting, rotation ratio, rotation degree and rotation position were analyzed compared to initial prescription divided to amount of cylinderical and spherical powers. Results: Rotation ratio of TSCL's axis was increased as increment of both cylinderical powers and (-)spherical powers. An average of rotation degree was $10^{\circ}{\sim}13^{\circ}$ which was not related to amount of their powers. Rotation position of TSCL's axis was more to temporal than to nasal. Conclusions: Because mis-alignment of axis after TSCL wearing induce the poor sight, adjustment of axial alignment as a result of follow-up must be performed.

Clinical Significance of Interferon $\gamma$ Release Assay for Diagnosis of Tuberculosis in Children (소아 결핵 진단에 있어서 결핵 특이항원자극 인터페론 감마 측정검사의 임상적 의의)

  • Lee, Hee Woo;Park, Hwa Young;Ahn, Young Min;Sohn, Keun Chan
    • Pediatric Infection and Vaccine
    • /
    • v.17 no.2
    • /
    • pp.137-147
    • /
    • 2010
  • Purpose : The purpose of this study is to evaluate the usefulness and limitation of QuantiFERON-TB Gold (QTB) for diagnosis of latent tuberculosis in children. Methods : The medical records of 112 children who were tested by tuberculin skin test (TST) and QTB for detection of latent tuberculosis (TB) in Eulji General Hospital during the period from January 2007 to June 2009 were retrospectively reviewed. Results : Of the 112 participants, the clinical TB group included 15 (13.4%), the contact group included 43 (38.4%), and the non-contact group included 54 (48.2%). Positive rates of TST and QTB were 100% and 80% in the clinical TB group, 64% and 14% in the close contact group, 27% and 0% in the casual contact group, and 52% and 2% in the non-contact group, respectively. Sensitivity of QTB was 80.0% and specificity was 92.6%. Agreement between QTB and TST was poor ($\kappa$=0.209). We also confirmed that the positive rate of QTB increased as the age of the patient increased (P=0.011). A QTB indeterminate result was observed in 11 (9.8%) subjects. QTB was retested in 15 subjects. In 5 of the 6 subjects who had positive results initially, positive results persisted for a median 2.2 months after termination of treatment. Conclusion : Although QTB was associated with several problems, including low sensitivity and a high rate of indeterminate results, it had clinical importance due to its high specificity. We found good correlation with regard to exposure and QTB positivity, including that of young children under 5 years of age. However, clinical application of interferon-$\gamma$ releasing assay for young children for diagnosis of active and latent tuberculosis will require additional prospective studies.

A Study on the Analysis of Korea's Library Policy and Performance to Establish Libraries' Role in Discovering Individuals' Potential (개인의 가능성을 발견하는 도서관 역할 정립을 위한 우리나라 도서관 정책 및 성과 분석 연구)

  • Younghee, Noh;Woojung, Kwak
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.56 no.4
    • /
    • pp.285-307
    • /
    • 2022
  • This study examines the policies currently announced in the "3rd Comprehensive Library Development Plan" in relation to the discovery of individuals' potential in libraries and analyzes the current status of the tasks promoted and executed by central administrative agencies and municipal and provincial libraries based on these policies. Based on the analysis results, this study presents the methods for libraries to play their role in discovering the potential of individuals in the future. According to the results of this study, due to the poor performance of libraries resulting from reduced in-person events because of library closures and the promotion of non-contact services such as humanities classes and cultural programs in response to COVID-19, it is necessary to establish systems to support emergency management and non-contact programs in response to COVID-19, as well as increase the budget for extending reading culture projects for underprivileged regions and people. In addition, it is necessary to discover quality long-term, non-contact programs, provide infrastructure for non-contact program operation, and develop guidelines. Second, it is observed that communication- and discussion-type social reading programs need to be promptly converted into and operated as online classes. Third, the study results confirm that it is necessary to prepare measures to reinforce external cooperation, such as improving the convenience of and accessibility to information use for users, conducting seminars between domestic and foreign councils, promoting one-stop data sharing systems, executing data digitalization, expanding library infrastructure in preparation for the post-COVID-19 era, and promoting public relations activities.

Pleural Carcinoembryonic Antigen and Maximum Standardized Uptake Value as Predictive Indicators of Visceral Pleural Invasion in Clinical T1N0M0 Lung Adenocarcinoma

  • Hye Rim Na;Seok Whan Moon;Kyung Soo Kim;Mi Hyoung Moon;Kwanyong Hyun;Seung Keun Yoon
    • Journal of Chest Surgery
    • /
    • v.57 no.1
    • /
    • pp.44-52
    • /
    • 2024
  • Background: Visceral pleural invasion (VPI) is a poor prognostic factor that contributes to the upstaging of early lung cancers. However, the preoperative assessment of VPI presents challenges. This study was conducted to examine intraoperative pleural carcinoembryonic antigen (pCEA) level and maximum standardized uptake value (SUVmax) as predictive markers of VPI in patients with clinical T1N0M0 lung adenocarcinoma. Methods: A retrospective review was conducted of the medical records of 613 patients who underwent intraoperative pCEA sampling and lung resection for non-small cell lung cancer. Of these, 390 individuals with clinical stage I adenocarcinoma and tumors ≤30 mm were included. Based on computed tomography findings, these patients were divided into pleural contact (n=186) and non-pleural contact (n=204) groups. A receiver operating characteristic (ROC) curve was constructed to analyze the association between pCEA and SUVmax in relation to VPI. Additionally, logistic regression analysis was performed to evaluate risk factors for VPI in each group. Results: ROC curve analysis revealed that pCEA level greater than 2.565 ng/mL (area under the curve [AUC]=0.751) and SUVmax above 4.25 (AUC=0.801) were highly predictive of VPI in patients exhibiting pleural contact. Based on multivariable analysis, pCEA (odds ratio [OR], 3.00; 95% confidence interval [CI], 1.14-7.87; p=0.026) and SUVmax (OR, 5.25; 95% CI, 1.90-14.50; p=0.001) were significant risk factors for VPI in the pleural contact group. Conclusion: In patients with clinical stage I lung adenocarcinoma exhibiting pleural contact, pCEA and SUVmax are potential predictive indicators of VPI. These markers may be helpful in planning for lung cancer surgery.