• 제목/요약/키워드: Pool boiling heat transfer

검색결과 142건 처리시간 0.018초

열전달 촉진 표면에서 임계 열유속까지의 물의 풀 비등 열전달계수 (Pool Boiling Heat Transfer Coefficients of Water Up to Critical Heat flux on Enhanced Surfaces)

  • 이요한;강동규;정동수
    • 설비공학논문집
    • /
    • 제23권3호
    • /
    • pp.194-200
    • /
    • 2011
  • In this work, nucleate pool boiling heat transfer coefficients(HTCs) of pure water are measured on horizontal 26 fpi low fin, Turbo-B and Thermoexcel-E square surfaces of 9.53 mm length. HTCs are taken from 10 $kW/m^2$ to critical heat flux for all surfaces. Test results show that critical heat fluxes(CHFs) of all enhanced surfaces are greatly improved as compared to that of a plain surface. CHFs of water on the 26 fpi low fin surface, Thermoexcel-E surface, and Turbo-B are increased up to 320%, 275%, and 150% as compared to that of the plain surface, respectively. CHF of the Turbo-B enhanced surface is lower than that of the 26 fpi low fin surface due to the surface geometry. The heat transfer enhancement ratios of the Thermoexcel-E surface, low fin surface and Turbo-B enhanced surface are 1.6~2.9, 1.6~2.1, 1.4~1.7 respectively in the range of heat fluxes tested. Judging from these results, it can be said that these types of enhanced surfaces can be used in heat transfer applications at high heat fluxes.

Thermoexcel-E 촉진 표면에서 임계 열유속까지의 풀 비등 열전달계수 (Pool Boiling Heat Transfer Coefficients Up to Critical Heat flux on Thermoexcel-E Enhanced Surface)

  • 이요한;강동규;장철한;정동수
    • 설비공학논문집
    • /
    • 제24권9호
    • /
    • pp.685-692
    • /
    • 2012
  • In this work, nucleate pool boiling heat transfer coefficients(HTCs) of 5 refrigerants of different vapor pressure are measured on horizontal Thermoexcel-E square surface of 9.53 mm length. Tested refrigerants are R32, R22, R134a, R152a and R245fa. HTCs are taken from 10 $kW/m^2$ to critical heat fluxes for all refrigerant at $7^{\circ}C$. Wall and fluid temperatures are measured directly by thermocouples located underneath the test surface and in the liquid pool. Test results show that critical heat fluxes(CHFs) of Thermoexcel-E enhanced surface are greatly improved as compared to that of a plain surface in all tested refrigerants. CHFs of all refrigerants on the Thermoexcel-E surface are increased up to 100% as compared to that of the plain surface. The improvement of Thermoexcel-E surface in CHF, however, is lower than that of the low fin surface. HTCs on Thermoexcel-E surface increase with heat flux. But after certain heat flux, HTCs began to decrease due to the difficulty in bubble removal caused by the inherent complex nature of this surface. Therefore, at heat fluxes close to the critical one, sudden decrease in HTCs needs to be considered in thermal design with Thermoexcel-E surface.

피치가 수평 튜브 배열의 풀비등에 미치는 영향 (Effects of Pitch on Pool Boiling from Horizontal Tube Array)

  • 강명기
    • 대한기계학회논문집B
    • /
    • 제41권11호
    • /
    • pp.719-726
    • /
    • 2017
  • 튜브 피치와 주변 튜브의 열유속이 수평으로 설치된 튜브 배열의 풀비등 열전달에 미치는 영향을 살펴보기 위하여 실험적 연구를 수행하였다. 실험을 위하여 외경이 19 mm인 두 개의 스테인리스강 튜브와 대기압 상태인 물을 사용하였다. 튜브간 피치는 18.5~95 mm이며, 주변 튜브의 열유속은 $0{\sim}90kW/m^2$이다. 열전달 향상은 주변 튜브의 열유속이 크고 시편의 열유속이 $40kW/m^2$보다 낮은 경우에 분명하게 관찰되었다. 피치가 튜브 지름의 4배 보다 크면 피치 변화가 열전달에 미치는 영향은 무시할 수 있을 정도이다. 순환유동, 대류유동, 액체교란은 열전달을 향상시키며 유동간섭과 기포군집은 열전달을 둔화시킨다.

다공도가 다른 전열촉진관의 냉매 풀비등에 미치는 오일의 영향 (Effect of Oil on Pool Boiling of Refrigerant on Enhanced Tubes having Different Pore Sizes)

  • 김내현;이응렬;민창근
    • 설비공학논문집
    • /
    • 제18권3호
    • /
    • pp.254-261
    • /
    • 2006
  • The effect of enhanced geometry (pore diameter, gap width) is investigated on the pool boiling of R-123/oil mixture for the enhanced tubes having pores with connecting gaps. Tubes with different pore diameters (and corresponding gap widths) are specially made. Significant heat transfer degradation by oil is observed for the present enhanced tubes. At 5% oil concentration, the degradation is 26 to 49% for $T_{sat}=4.4^{\circ}C$. The degradation increases 50 to 67% for $T_{sat}=26.7^{\circ}C$. The heat transfer degradation is significant even with small amount of oil (20 to 38% degradation at 1% oil concentration for $T_{sat}=4.4^{\circ}C$), probably due to the accumulation of oil in sub-tunnels. The pore size (or gap width) has a significant effect on the heat transfer degradation. The maximum degradation is observed for $d_p$ = 0.20 mm tube at $T_{sat}=4.4^{\circ}C$, and for $d_p$=0.23 mm tube at $T_{sat}=26.7^{\circ}C$. The minimum degradation is observed for $d_p$=0.27 mm tube for both saturation temperatures. It appears that the oil removal is facilitated for the larger pore diameter (along with larger gap) tube. The highest heat transfer coefficient with oil is obtained for $d_p$ =0.23 mm tube, which yielded the highest heat transfer coefficient for pure R-123. The heat transfer degradation increases as the heat flux decreases.

낮은 핀 표면과 Turbo-B 촉진 표면에서 임계 열유속까지의 풀 비등 열전달계수 (Pool Boiling Heat Transfer Coefficients Up to Critical Heat flux on Low-fin and Turbo-B Surfaces)

  • 이요한;정동수
    • 설비공학논문집
    • /
    • 제23권3호
    • /
    • pp.179-187
    • /
    • 2011
  • In this work, nucleate pool boiling heat transfer coefficients(HTCs) of 5 refrigerants of differing vapor pressure are measured on horizontal low fin and Turbo-B square surfaces of 9.53 mm length. Tested refrigerants are R32, R22, R134a, R152a and R245fa and HTCs are taken from 10 $kW/m^2$ to critical heat fluxes for all refrigerant at $7^{\circ}C$. Wall and fluid temperatures are measured directly by thermocouples located underneath the test surface and in the liquid pool. Test results show that Critical heat fluxes(CHFs) of all enhanced surfaces are greatly improved as compared to that of a plain surface in all tested refrigerants. CHFs of all refrigerants on the 26 fpi low fin surface are increased up to 240% as compared to that of the plain surface. HTCs on both low fin and Turbo-B surfaces increase with heat flux. After certain heat flux, however, they decrease. CHFs of the Turbo-B enhanced surface are lower than that of the 26 fpi low fin surface. This phenomenon is due to the difference in surface structure of the low fin and Turbo-B surface.

나노유체의 임계열유속 및 비등특성에 미치는 나노입자 크기의 영향 (Effect of particle sizes on CHF enhancement and boiling characteristics of nano-fluids)

  • 조병남;강준원;유재석;김현정
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2006년도 추계학술대회 논문집
    • /
    • pp.125-130
    • /
    • 2006
  • The characteristics of boiling heat transfer and critical heat flux (CHF) behavior of nano-fluids were studied by using various sized silver and alumina nanoparticles. The diameter of nanoparticles was from 2 nm to 250 nm for silver and from 20nm to 40nm for alumina. Pool boiling characteristics and CHF enhancement of nano-fluids with different sized nanoparticles were compared with those of pure water and each nano-fluids. The experiment was performed at atmospheric pressure and the temperature of the pool was maintained constantly by using a flat immersed heater. The concentration of nano-fluids was uniform in all experiments as 0.01g/liter. The results showed that the measured boiling curves were shifted to the right. It demonstrated that the occurrence of nucleate boiling regime in nano-fluids retarded, compared with that of pure water. Also, in nano-fluids, the boiling curves showed that CHF of nano-fluids is significantly enhanced and represented the effect of particle size on boiling characteristics.

  • PDF

평활관과 낮은 핀관에서 R245fa의 풀 비등 열전달계수 (Pool Boiling Heat Transfer Coefficient of R245fa on the Plain Tube and the Low Fin Tube)

  • 박기정;이요한;임병덕;정동수
    • 설비공학논문집
    • /
    • 제23권3호
    • /
    • pp.208-215
    • /
    • 2011
  • In this work, pool boiling heat transfer coefficients(HTCs) of R22, R123, R134a, and R245fa are measured on both horizontal plain and 26 fpi low fin tubes. The pool boiling temperature is maintained at $7^{\circ}C$ and heat flux is varied from 80 $kW/m^2$ to 10 $kW/m^2$ with an interval of 10 $kW/m^2$. Wall temperatures are measured directly by thermocouples inserted through holes of 0.5 mm diameter. Test results show that HTCs of high vapor pressure refrigerants are usually higher than those of low pressure fluids in both plain and low fin tubes. On a plain tube, HTCs of R245fa are 23.3% higher than those of R123 while on a 26 fpi low fin tube, HTCs of R245fa are 46.3% higher than those of R123. The fin effect is more prominent with low vapor pressure refrigerants than with high vapor pressure ones due to a sweeping effect.

탄소나노튜브 적용 나노유체의 임계 열유속까지의 비등 열전달계수 (Boiling Heat Transfer Coefficients of Nanofluids Containing Carbon Nanotubes up to Critical Heat Fluxes)

  • 박기정;이요한;정동수;심상은
    • 대한기계학회논문집B
    • /
    • 제35권7호
    • /
    • pp.665-676
    • /
    • 2011
  • 본 연구에서는 순수 물에 탄소나노튜브를 분산시킨 나노유체를 작동유체로 하여 $60^{\circ}C$ 에서 정사각형 구리 평면 히터를 이용하여 핵 비등 열전달계수와 임계 열유속을 측정하였다. 탄소나노튜브의 체적비는 0.0001%, 0.001%, 0.01%까지 변화시켜 실험을 수행하였다. 탄소나노튜브는 고분자 물질을 사용하여 분산시키지 않고 탄소나노튜브에 직접 산화처리를 하여 분산시켰다. 실험 결과 나노유체의 열전달계수는 순수 물과 비교해 모든 체적비에서 증가하였다. 산화 처리를 한 탄소나노튜브는 비등이 일어나는 동안 열 경계층 안에서 열전도도가 큰 탄소나노튜브가 침착되지 않고 열전달 표면에 자주 접촉함으로써 열 경계층을 교란시켜 비등 열전달을 촉진시키는 것으로 사료된다. 임계 열유속은 체적비 0.001%에서 순수 물의 결과에 비해 150%까지 증가하였다. 이는 열전달 표면에서 탄소나노튜브가 매우 얇게 침착되어 생긴 나노 막으로 인해 거대한 기포막의 형성이 억제되고 핵 비등이 높은 열유속에서도 지속되어 임계 열유속이 증가하는 것으로 판단된다.

만액식 증발기의 열전달 촉진관에서 저온 비등열전달의 이력현상 특성 (Hysteresis on Boiling Heat Transfer at Low Temperature on Enhanced Tubes in a Flooded Evaporator)

  • 윤현필;박종익;정진희;강용태
    • 설비공학논문집
    • /
    • 제15권4호
    • /
    • pp.254-260
    • /
    • 2003
  • The boiling characteristics for R134a are studied to clarify the hysteresis at low temperature on enhanced tubes of a flooded evaporator. Initial boiling conditions, refrigerant temperature, and inlet temperature of the chilled water are considered as the key parameters of the experiments. Unlike previous studies of the boiling heat transfer with uniform heat flux and uniform wall temperature, the wall temperature was varied along the tube. In, this study, it was found that the hysteresis of the temperature overshoot (705) at the onset of nucleate boiling initially at the inlet section of the tube. It is also concluded that the abnormal operation can be avoided during the low temperature boiling if the refrigeration system is started with LMTD larger than $3.4^{\circ}C$ at initial stage and larger than $1.0^{\circ}C$ at normal stage.

절삭유 냉각용 낮은 핀관의 응축 및 비등 열전달 성능에 관한 연구 (A Study on the Performance of the Condensation and the Boiling Heat Transfer of Low Fin Tubes Used in Cooling of the Cutting Oil)

  • 조동현;이종선
    • 한국생산제조학회지
    • /
    • 제8권4호
    • /
    • pp.65-65
    • /
    • 1999
  • Heat transfer performance is studied for boiling and condensation of R-11 on integral-fin tubes. Nine tubes with trapezoidal integral-fins having fin densities from 748 to 1654fpm and 10,30 grooves and finned tubes with caves of 0.55 and 0.64 mm height respectively are tested. in case of condensation CFC-11 condensates at saturation stat of 32℃ on the outside surface cooled by inside cooling water flows. And in case of boiling the refrigerant evaporates at a saturation state of 1 bar on the outside tube surface and heat is supplied by hot water which circulates inside of the tube,. The tube having fin transfer coefficient concerns fin tubes with caves show higher valve than low fin tube having find density of 1299fpm and 30grooves. The overall heat transfer coefficient of fin tube with caves is about 5155 W/mK at 2.8m/s of water velocity, The value is abuot 2.7 times higher than plain tube and 1.3 times higher than low fin tube having fin density of 1299fpm and 30 grooves.