• 제목/요약/키워드: Polyvinylchloride

검색결과 61건 처리시간 0.196초

정상 견에서 수액세트 점적통을 이용한 새로운 기관 외부 보철링의 적용 (Application of new external total ring prostheses made by drip chamber of intravenous administration set in normal dogs)

  • 정상휘;정순욱
    • 대한수의학회지
    • /
    • 제44권1호
    • /
    • pp.137-141
    • /
    • 2004
  • The purpose of this study was to compare easiness of application of polypropylene external total ring prosthesis (PPTRP, Group A) with that of polyvinylchloride external total ring prosthesis (PVCTRP, Group B), which were used for surgical correction of tracheal collapse in dogs. PPTRP was made from 3 ml syringe and PVCTRP from the drip chamber of intravenous administration set. Prostheses of group A (n=5) and B (n=5) were placed to cervical trachea in clinically normal 10 dogs, respectively weighing between 4 kg and 6 kg. There were mild coughing and swelling in one to three dogs of both groups for 3 days after surgery. No exercise intolerance was observed in both groups after surgery. There were no different results of clinical signs and radiographic views after surgery between group A and group B. The time (mean${\pm}$SD) to make total ring prosthesis, group A took $23.2{\pm}1.9$ minutes which was remarkably longer than that $(4.6{\pm}0.3)$ of group B. Also, the time to place around trachea, group A required $61.8{\pm}8.8$ minutes and group B $38.4{\pm}8.0$ minutes. Conclusionly, PVCTRP was timesaving and easier to make, fix, and suture than those of PPTRP. PVCTRP may be used alternatively to PPTRP for the tracheal collapse to treat in dogs.

대황 및 황련추출물 처리에 따른 시설채소산물의 품질특성 변화 (Treatment of Korean Medical Herb Extracts Affects the Quality Characteristics of Vegetables)

  • 박우포;조성환
    • 한국식품저장유통학회지
    • /
    • 제6권3호
    • /
    • pp.276-280
    • /
    • 1999
  • 항균력이 있는 것으로 확인된 대황 및 황련추출물을 오이, 호박, 상치 및 고추에 처리하였을 때 총균수가 감소하였다. 채소의 종류에 따라서 적절한 처리농도는 달랐는 데, 호박, 상치 및 고추는 100 ppm, 오이는 500 ppm 처리가 적절한 것으로 나타났다. 채소를 침지할 때의 시간은 10분 정도가 적절한 것으로 나타났으며, 세척수의 온도를 4$0^{\circ}C$로 높일 경우에도 채소류 표면의 총균수 감소 효과는 실온의 세척수와 비슷하였다. 또한 오이와 호박을 대황 및 황련 추출물로 처리한 다음 1$0^{\circ}C$에서 건조하고 PVC랩으로 포장하여 저장한 결과 대조구에 비하여 총균수가 낮은 것으로 나타났다. 저장 기간 중 무게는 지속적으로 감소하였으며, 처리구와 대조구간에 큰 차이를 나타내지는 않았다. Ascorbic acid의 함량은 저장 기간 중 지속적으로 감소하는 것으로 나타났는데, 대황 및 황련추출물을 처리한 시험구가 대조구에 비하여 ascorbic acid의 함량이 높은 것으로 나타났다

  • PDF

An Amperometric Proton Selective Sensor with an Elliptic Microhole Liquid/Gel Interface for Vitamin-C Quantification

  • Faisal, Shaikh Nayeem;Hossain, Md. Mokarrom;Lee, Hye-Jin
    • Journal of Electrochemical Science and Technology
    • /
    • 제1권2호
    • /
    • pp.121-126
    • /
    • 2010
  • An amperometric ascorbic acid selective sensor utilizing the transfer reaction of proton liberated from the dissociation of ascorbic acid in aqueous solution across an elliptic micro-hole water/organic gel interface is demonstrated. This redox inactive sensing platform offers an alternative way for the detection of ascorbic acid to avoid a fouling effect which is one of the major concerns in redox based sensing systems. The detection principle is simply measuring the current change with respect to the assisted transfer of protons by a proton selective ionophore (e.g., ETH 1778) across the micro-hole interface between the water and the polyvinylchloride-2-nitrophenyloctylether gel phase. The assisted transfer reaction of protons generated from ascorbic acid across the polarized micro-hole interface was first characterized using cyclic voltammetry. An improved sensitivity for the quantitative analysis of ascorbic acid was achieved using differential pulse stripping voltammetry with a linear response ranging from 1 to $100\;{\mu}M$ concentrations of ascorbic acid. As a demonstration, the developed sensor was applied for analyzing the content of vitamin-C in different types of commercial pharmaceutical tablets and syrups, and a satisfactory recovery from these samples were also obtained.

레이저 조사에 의한 endotracheal tubes의 안정성에 대한 연구

  • 정필상;김영훈;정필섭;이정구
    • 대한기관식도과학회:학술대회논문집
    • /
    • 대한기관식도과학회 1995년도 이비인후과 종합학술대회 초록집
    • /
    • pp.91.2-91
    • /
    • 1995
  • 레이저를 이용한 구강 및 인후두 수술시 endotracheal tubes의 손상은 치명적이라 아니 할 수 없다. 이에 저자들은 여러 가지 endotracheal tube를 실험 재료로 사용하여 보다 안전한 레이저 수술을 위해서 적절한 endotracheal tube를 찾기 위해 본 실험을 시행하였다. 실험에 사용된 tube는 총 5가지 - $Bivona^{TM}$, Xomed Laser Shield $II^{TM}$, Mallinckrodt Laser-$Flex^{TM}$, Rusch tube wrapped with aluminium foil tape(Rusch tube), Polyvinylchloride tube wrapped with aluminium foil tape(PVC tube) - 가 사용되었다. 사용된 레이저는 KTP/532 와 $CO_2$ laser 이며 모든 실험에서 tube를 $FiO_2$ 95%-98% 상태에서 조사하여 각각 5회씩 실시하였다. tube에 이상이 없거나 발화가 되지 않는 한 90초 동안 시행하였다. 실험 결과, KTP/532 조사시 $Bivona^{TM}$, Mallinckrodt 와 PVC tube는 심한 손상을 받거나 발화하였으며 Xomed 와 Rusch tube는 안정된 상태를 유지하였고 $CO_2$ Laser 조사시는 KTP/532 조사시와 유사한 결과를 얻었다. 한편 혈액을 endotracheal tube에 도포한 상황에서는 모든 tube가 더 심한 손상을 보이는 바 KTP/532 조사시 Xomed는 상당히 안정된 상태를 유지하였고 나머지 tube는 심한 손상 또는 발화를 보이고 $CO_2$ Laser 조사시 $Bivona^{TM}$ 와 Mallinckrodt는 발화하였고 Rusch tube는 표면이 녹았으며 Xomed와 PVC tube도 1례에서 발화하였다. 향후 이비인후과 영역에서의 레이저 수술이 증가함을 예상할 때 좀 더 레이저에 대하여 안정적이고 경제적인 endotracheal tube의 개발이 필요할 것으로 사료된다.

  • PDF

진동.충격음 흡수성능을 지니는 목질계 복합재료의 개발(I) -가소화 폴리염화비닐의 동적점탄성과 진동흡수성능- (Development of Vibraction and Impact Noise Dampling Wood-based Composites(I) -Dynamic Mechanical and Vibration Damping Properties of Plasticized PVC-)

  • 이현종
    • 임산에너지
    • /
    • 제17권1호
    • /
    • pp.36-46
    • /
    • 1998
  • 이 연구는 점탄성 고분자재료를 사용하여 진동·충격음 흡수성능을 지니는 목질계 복합재료의 제조를 목적으로, 가소화 PVC의 동적점탄성 및 고분자 적층 복합체의 진동흡수성능에 미치는 고분자의 점탄성의 영향을 검토하였다. 가소제는 디옥틸프탈레이트(DOP)를 사용하여, 20∼140 phr까지 첨가하였다. 고분자의 동적점탄성의 측정은 Rheovibron을 사용하여 110Hzdml 인장진동을 가하여, -100∼150℃까지 매분 1℃를 상승시키면서 측정하였다. PVC와 DOP는 전조성에서 완전상용성이었으며, T(E"max)와 T(tan δmax)는 가소제의 첨가량이 증가함에 따라 저온 측으로 이동하였다. 고분자 적층 복합체의 진동흡수성능은 Rheovibron을 개조한 양단지지 중심하중에 의한 강제 휨진동법 및 공진법에 하나인 양단자유 휨진동법을 사용하였다. 샌드위치구조 복합체의 진동흡수계수(tanδc)는 고분자의 손실계수(tanδ)와 정의 상관성을 나타내었으며, 피복체의 진동흡수계수는 고분자의 손실탄성률(E")에 의존하는 경향을 나타내었다. 또한 샌드위치구조 복합체의 대수감쇠율(Δc)은 tanδc곡선과 유사한 곡선을 나타내었다.

  • PDF

Portable Amperometric Perchlorate Selective Sensors with Microhole Array-water/organic Gel Interfaces

  • Lee, Sang Hyuk;Kim, Hyungi;Girault, Hubert H.;Lee, Hye Jin
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권9호
    • /
    • pp.2577-2582
    • /
    • 2013
  • A novel stick-shaped portable sensing device featuring a microhole array interface between the polyvinylchloride-2-nitrophenyloctylether (PVC-NPOE) gel and water phase was developed for in-situ sensing of perchlorate ions in real water samples. Perchlorate sensitive sensing responses were obtained based on measuring the current changes with respect to the assisted transfer reaction of perchlorate ions by a perchlorate selective ligand namely, bis(dibenzoylmethanato)Ni(II) (Ni(DBM)2) across the polarized microhole array interface. Cyclic voltammetry was used to characterize the assisted transfer reaction of perchlorate ions by the $Ni(DBM)_2$ ligand when using the portable sensing device. The current response for the transfer of perchlorate anions by $Ni(DBM)_2$ across the micro-water/gel interface linearly increased as a function of the perchlorate ion concentration. The technique of differential pulse stripping voltammetry was also utilized to improve the sensitivity of the perchlorate anion detection down to 10 ppb. This was acquired by preconcentrating perchlorate anions in the gel layer by means of holding the ion transfer potential at 0 mV (vs. Ag/AgCl) for 30 s followed by stripping the complexed perchlorate ion with the ligand. The effect of various potential interfering anions on the perchlorate sensor was also investigated and showed an excellent selectivity over $Br^-$, $NO_2{^-}$, $NO_3{^-}$, $CO{_3}^{2^-}$, $CH_3COO^-$ and $SO{_4}^{2^-}$ ions. As a final demonstration, some regional water samples from the Sincheon river in Daegu city were analyzed and the data was verified with that of ion chromatography (IC) analysis from one of the Korean-certified water quality evaluation centers.

폐글리세롤을 이용한 친환경 가소제의 경구투여독성 및 피부자극성 시험 (The oral dose toxicity test and skin irritation test of eco-friendly plasticizer using crude glycerol derived)

  • 강수정;김희영;박상원;심은영;김진환
    • 한국산업보건학회지
    • /
    • 제25권3호
    • /
    • pp.322-327
    • /
    • 2015
  • Objectives: The major objective of this study is the oral dose toxicity test and skin irritation test of eco-friendly plasticizer using crude glycerol derived from the biodiesel process. Methods: Glyceroldiacetate laurate(GDL) was synthesized from glycerol monolaurat(GML) and acetic acid. The synthesis of the GDL plasticizer was measured with nuclear magnetic resonance spectroscop(NMR) and FT-IR(Fourier Transform Infrared Spectrometer). To provide information on the safety of GDL, we carried out an oral dose toxicity test for GDL in Sprague-Dawley rats. Also, we carried out a skin irritation test for GDL in New Zealand White rabbits. Results: The oral dose toxicity test in Sprague-Dawley rats showed that GDL is a non-toxic material. The result of the skin irritation test on New Zealand White rabbits showed that GDL is non-irritating. Conclusions: From the results of oral dose toxicity test and skin irritation test, we concluded that the developed plasticizer showed excellent eco-friendly property. Based on our results, we confirmed the development of an eco-friendly non-phthalate plasticizer. Applicability for PVC toys and food and drug packaging materials was found.

피막법에 의한 경구투여용 제어방출제제의 개발-III-테오필린함유 제어방출제제의 제조 및 사람의 타액중 농도로부터의 평가- (Development of Controlled Release Oral Drug Delivery System by Membrane-Coating Method-III- Preparation of Theophylline Tablets and Pharmacokinetic Evaluation in Man-)

  • 심창구;김종국;이민화;김신근
    • Journal of Pharmaceutical Investigation
    • /
    • 제22권3호
    • /
    • pp.205-210
    • /
    • 1992
  • In order to develop a controlled-release oral drug delivery system (DDS) of theophylline (TP), microporous membrane-coated tablets were prepared and evaluated in vitro and in vivo. Rapidly water-soluble core tablets of TP (300 mg) were prepared by wet granulation and compression technique, Then the core tablets were spray-coated with polyvinylchloride (PVC) in which micronized sucrose particles were dispersed. Effect of formula compositions of coating suspensions on the pharmaceutical characteristics such as membrane strength and dissolution was investigated in vitro. The membranes remained unbroken in pH 1.2 buffer at $37^{\circ}C$ at least for 2 hours after the disintergration test. TP was released from the coated-released tablets at a zero-order rate over 8 hours. The release at pH 1.2 and 4.0 was similar in rate but a little more rapid than that at pH 6.8. The coated tablets were administered to three healthy male volunteers and their saliva profiles of TP were compared with those from the commercial sustained release TP tablets such as Slobid and Asconthin. Saliva TP concentrations from the coated tablets were successfully sustained over 48 hours after the dosing and were comparable to those of the commercial sustained-release tablets. The membrane-coating technique is very simple and does not need any sophisticated equipments. In this respect, the membrane-coated tablets may be superior to the commercial sustained-release tablets and this technique is worth adopting by the pharmaceutical industries.

  • PDF

Development of Controlled Release Oral Drug Delivery System by Membrane-Coating Method-I - Preparation and pharmaceutical evaluation of controlled release acetaminophen tablets-

  • Shim, Chang-Koo;Kim, Ki-Man;Kim, Young-Il;Kim, Chong-Kook
    • Archives of Pharmacal Research
    • /
    • 제13권2호
    • /
    • pp.151-160
    • /
    • 1990
  • In order to develop a controlled-release oral drug delivery system (DDS) which sustains the plasma acetaminophen (AAP) concentration for a certain period of time, microporous membrane-coated tablets were prepared and evaluated in vitro. Firstly, highly water-soluble core tablet of AAP were prepared with various formulations by wet granulation and compression technique. Then the core tablets were coated with polyvinychloride (PVC) in which micronized sucrose particles were dispersed. Effect of formula compositions of core tablets and coating suspensions on the pharmaceutical characteristics such as drug release kinetics and membrane stability of the coated tablets was investigated in vitro. AAP was released from the coated tablets as a zero-order rate in a pH-independent manner. This independency of AAP release to pH change from 1.2 to 7.2 is favorable for the controlled oral drug delivery, since it will produce a constant drug release in the stomach and intestine regardless of the pH change in the GI tract. Drug release could be extended upto 10 h according to the coating condition. The release rate could be controlled by changing the formula compositions of the core tablets and coating suspensions, coat weight per each tablet, and especially PVC/sucrose ratio and particle size of the sucrose in the coating suspension. The coated tablets prepared in this study had a fairly good pharmaceutical characteristics in vitro, however, overall evaluation of the coated tablet should await in vivo absorption study in man.

  • PDF

초음파 표면개질에 의한 CDI 전극용 술폰화 염화비닐(PVC) 멤브레인의 제조 및 특성 (Preparation and Properties of Sulfonated Polyvinylchloride (PVC) Membrane for Capacitive Deionization Electrode by Ultra Sonication Modification)

  • 황치원;오창민;황택성
    • 접착 및 계면
    • /
    • 제15권1호
    • /
    • pp.1-8
    • /
    • 2014
  • 이온 교환막은 전기투석, 확산투석, Redox flow 전지, 연료전지 등 다양하고 넓은 분야에서 사용되고 있다. 초음파를 이용하여 만들어진 PVC 양이온 교환막을 시간을 변화시켜 가면서 술폰화 반응에 의해 제조하였다. 술폰화제로 황산을 사용하였으며, 술폰화 PVC 양이온 교환막의 기본구조와 특성을 FT-IR, EDX, Water uptake, 이온교환용량(IEC), 전기저항(ER), 전도도, 이온수송수 및 표면 morphology를 SEM 분석하였다. FT-IR 스펙트럼 분석결과 술폰화 PVC 양이온 교환막에 술폰산기가 도입되었음을 확인하였으며 멤브레인의 Water uptake, IEC, 전기 저항 및 ion transport number의 최대값은 각각 40.2%, 0.87 meq/g, $35.2{\Omega}{\cdot}cm^2$ 및 0.88이었다.