• Title/Summary/Keyword: Polyvinylchloride

Search Result 62, Processing Time 0.019 seconds

Application of new external total ring prostheses made by drip chamber of intravenous administration set in normal dogs (정상 견에서 수액세트 점적통을 이용한 새로운 기관 외부 보철링의 적용)

  • Jeong, Sang-hyi;Jeong, Soon-wuk
    • Korean Journal of Veterinary Research
    • /
    • v.44 no.1
    • /
    • pp.137-141
    • /
    • 2004
  • The purpose of this study was to compare easiness of application of polypropylene external total ring prosthesis (PPTRP, Group A) with that of polyvinylchloride external total ring prosthesis (PVCTRP, Group B), which were used for surgical correction of tracheal collapse in dogs. PPTRP was made from 3 ml syringe and PVCTRP from the drip chamber of intravenous administration set. Prostheses of group A (n=5) and B (n=5) were placed to cervical trachea in clinically normal 10 dogs, respectively weighing between 4 kg and 6 kg. There were mild coughing and swelling in one to three dogs of both groups for 3 days after surgery. No exercise intolerance was observed in both groups after surgery. There were no different results of clinical signs and radiographic views after surgery between group A and group B. The time (mean${\pm}$SD) to make total ring prosthesis, group A took $23.2{\pm}1.9$ minutes which was remarkably longer than that $(4.6{\pm}0.3)$ of group B. Also, the time to place around trachea, group A required $61.8{\pm}8.8$ minutes and group B $38.4{\pm}8.0$ minutes. Conclusionly, PVCTRP was timesaving and easier to make, fix, and suture than those of PPTRP. PVCTRP may be used alternatively to PPTRP for the tracheal collapse to treat in dogs.

Treatment of Korean Medical Herb Extracts Affects the Quality Characteristics of Vegetables (대황 및 황련추출물 처리에 따른 시설채소산물의 품질특성 변화)

  • 박우포;조성환
    • Food Science and Preservation
    • /
    • v.6 no.3
    • /
    • pp.276-280
    • /
    • 1999
  • To maintain the quality characteristics of vegetables, produce was dipped in Korean medical herb extracts (KMHE) such as Rheum palmatum L. or Coptis chinensis Franch with different concentration. Dipping in 500 ppm KMHE solution was suitable for the reduction or microbial load on cucumber, and 100 ppm KMHE solution was appropriate for others. Dipping time was suitable for produce about 10 minutes, and the temperature of dining solution had a limited effect cm the microbial load reduction. Antimicrobial activity of Coptis chinensis Franch and Rheum palmatum L. was maintained for cucumber and zucchini wrapped with polyvinylchloride film during storage at 10$^{\circ}C$.

  • PDF

An Amperometric Proton Selective Sensor with an Elliptic Microhole Liquid/Gel Interface for Vitamin-C Quantification

  • Faisal, Shaikh Nayeem;Hossain, Md. Mokarrom;Lee, Hye-Jin
    • Journal of Electrochemical Science and Technology
    • /
    • v.1 no.2
    • /
    • pp.121-126
    • /
    • 2010
  • An amperometric ascorbic acid selective sensor utilizing the transfer reaction of proton liberated from the dissociation of ascorbic acid in aqueous solution across an elliptic micro-hole water/organic gel interface is demonstrated. This redox inactive sensing platform offers an alternative way for the detection of ascorbic acid to avoid a fouling effect which is one of the major concerns in redox based sensing systems. The detection principle is simply measuring the current change with respect to the assisted transfer of protons by a proton selective ionophore (e.g., ETH 1778) across the micro-hole interface between the water and the polyvinylchloride-2-nitrophenyloctylether gel phase. The assisted transfer reaction of protons generated from ascorbic acid across the polarized micro-hole interface was first characterized using cyclic voltammetry. An improved sensitivity for the quantitative analysis of ascorbic acid was achieved using differential pulse stripping voltammetry with a linear response ranging from 1 to $100\;{\mu}M$ concentrations of ascorbic acid. As a demonstration, the developed sensor was applied for analyzing the content of vitamin-C in different types of commercial pharmaceutical tablets and syrups, and a satisfactory recovery from these samples were also obtained.

레이저 조사에 의한 endotracheal tubes의 안정성에 대한 연구

  • 정필상;김영훈;정필섭;이정구
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1995.04a
    • /
    • pp.91.2-91
    • /
    • 1995
  • 레이저를 이용한 구강 및 인후두 수술시 endotracheal tubes의 손상은 치명적이라 아니 할 수 없다. 이에 저자들은 여러 가지 endotracheal tube를 실험 재료로 사용하여 보다 안전한 레이저 수술을 위해서 적절한 endotracheal tube를 찾기 위해 본 실험을 시행하였다. 실험에 사용된 tube는 총 5가지 - $Bivona^{TM}$, Xomed Laser Shield $II^{TM}$, Mallinckrodt Laser-$Flex^{TM}$, Rusch tube wrapped with aluminium foil tape(Rusch tube), Polyvinylchloride tube wrapped with aluminium foil tape(PVC tube) - 가 사용되었다. 사용된 레이저는 KTP/532 와 $CO_2$ laser 이며 모든 실험에서 tube를 $FiO_2$ 95%-98% 상태에서 조사하여 각각 5회씩 실시하였다. tube에 이상이 없거나 발화가 되지 않는 한 90초 동안 시행하였다. 실험 결과, KTP/532 조사시 $Bivona^{TM}$, Mallinckrodt 와 PVC tube는 심한 손상을 받거나 발화하였으며 Xomed 와 Rusch tube는 안정된 상태를 유지하였고 $CO_2$ Laser 조사시는 KTP/532 조사시와 유사한 결과를 얻었다. 한편 혈액을 endotracheal tube에 도포한 상황에서는 모든 tube가 더 심한 손상을 보이는 바 KTP/532 조사시 Xomed는 상당히 안정된 상태를 유지하였고 나머지 tube는 심한 손상 또는 발화를 보이고 $CO_2$ Laser 조사시 $Bivona^{TM}$ 와 Mallinckrodt는 발화하였고 Rusch tube는 표면이 녹았으며 Xomed와 PVC tube도 1례에서 발화하였다. 향후 이비인후과 영역에서의 레이저 수술이 증가함을 예상할 때 좀 더 레이저에 대하여 안정적이고 경제적인 endotracheal tube의 개발이 필요할 것으로 사료된다.

  • PDF

Development of Vibraction and Impact Noise Dampling Wood-based Composites(I) -Dynamic Mechanical and Vibration Damping Properties of Plasticized PVC- (진동.충격음 흡수성능을 지니는 목질계 복합재료의 개발(I) -가소화 폴리염화비닐의 동적점탄성과 진동흡수성능-)

  • 이현종
    • Journal of Korea Foresty Energy
    • /
    • v.17 no.1
    • /
    • pp.36-46
    • /
    • 1998
  • The aim of this study was to develop the noise and vibration damping wood-based composites by using viscoelastic polymer materials. Polyvinylchloride(PVC) was plasticized with 20-140 phr bis(2-ethylhexyl) phthalate(DOP) and the dynamic tensile mechanical properties were measured at 110Hz and approximate temperature range -100 to 150$^{\circ}$ using a Rheovibron Instrument. The PVC/DOP blends were shown to be compatible in all proportions, and both T(E”$_{max}$) and T(tan${\delta}_{max}$) shifted to the lower temperature side as the DOP content increased. The vibration damping properties of wood/polymer composites were measured using the Rheovibron instrument in a bending mode. The composite damping factor(tan ${\delta}_{c}$) of wood /PVC-DOP/wood sandwich structure correlated with the loss factor and that of the coated structure correlated with the loss modulus(E”) of the polymer layer. In addition, the sandwich structure was found to be more effective in damping than the coated structure. The logarithmic decrement (${\Delta}$c) curve of a sandwich structure, which was determined by the free-free flexural vibration method was similar in shape to the tan ${\delta}_{c}$ curve.

  • PDF

Portable Amperometric Perchlorate Selective Sensors with Microhole Array-water/organic Gel Interfaces

  • Lee, Sang Hyuk;Kim, Hyungi;Girault, Hubert H.;Lee, Hye Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.9
    • /
    • pp.2577-2582
    • /
    • 2013
  • A novel stick-shaped portable sensing device featuring a microhole array interface between the polyvinylchloride-2-nitrophenyloctylether (PVC-NPOE) gel and water phase was developed for in-situ sensing of perchlorate ions in real water samples. Perchlorate sensitive sensing responses were obtained based on measuring the current changes with respect to the assisted transfer reaction of perchlorate ions by a perchlorate selective ligand namely, bis(dibenzoylmethanato)Ni(II) (Ni(DBM)2) across the polarized microhole array interface. Cyclic voltammetry was used to characterize the assisted transfer reaction of perchlorate ions by the $Ni(DBM)_2$ ligand when using the portable sensing device. The current response for the transfer of perchlorate anions by $Ni(DBM)_2$ across the micro-water/gel interface linearly increased as a function of the perchlorate ion concentration. The technique of differential pulse stripping voltammetry was also utilized to improve the sensitivity of the perchlorate anion detection down to 10 ppb. This was acquired by preconcentrating perchlorate anions in the gel layer by means of holding the ion transfer potential at 0 mV (vs. Ag/AgCl) for 30 s followed by stripping the complexed perchlorate ion with the ligand. The effect of various potential interfering anions on the perchlorate sensor was also investigated and showed an excellent selectivity over $Br^-$, $NO_2{^-}$, $NO_3{^-}$, $CO{_3}^{2^-}$, $CH_3COO^-$ and $SO{_4}^{2^-}$ ions. As a final demonstration, some regional water samples from the Sincheon river in Daegu city were analyzed and the data was verified with that of ion chromatography (IC) analysis from one of the Korean-certified water quality evaluation centers.

The oral dose toxicity test and skin irritation test of eco-friendly plasticizer using crude glycerol derived (폐글리세롤을 이용한 친환경 가소제의 경구투여독성 및 피부자극성 시험)

  • Kang, Soo-Jung;Kim, Heeyoung;Park, Sangwon;Sim, Eunyoung;Kim, Jinhwan
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.3
    • /
    • pp.322-327
    • /
    • 2015
  • Objectives: The major objective of this study is the oral dose toxicity test and skin irritation test of eco-friendly plasticizer using crude glycerol derived from the biodiesel process. Methods: Glyceroldiacetate laurate(GDL) was synthesized from glycerol monolaurat(GML) and acetic acid. The synthesis of the GDL plasticizer was measured with nuclear magnetic resonance spectroscop(NMR) and FT-IR(Fourier Transform Infrared Spectrometer). To provide information on the safety of GDL, we carried out an oral dose toxicity test for GDL in Sprague-Dawley rats. Also, we carried out a skin irritation test for GDL in New Zealand White rabbits. Results: The oral dose toxicity test in Sprague-Dawley rats showed that GDL is a non-toxic material. The result of the skin irritation test on New Zealand White rabbits showed that GDL is non-irritating. Conclusions: From the results of oral dose toxicity test and skin irritation test, we concluded that the developed plasticizer showed excellent eco-friendly property. Based on our results, we confirmed the development of an eco-friendly non-phthalate plasticizer. Applicability for PVC toys and food and drug packaging materials was found.

Development of Controlled Release Oral Drug Delivery System by Membrane-Coating Method-III- Preparation of Theophylline Tablets and Pharmacokinetic Evaluation in Man- (피막법에 의한 경구투여용 제어방출제제의 개발-III-테오필린함유 제어방출제제의 제조 및 사람의 타액중 농도로부터의 평가-)

  • Shim, Chang-Koo;Kim, Chong-Kook;Lee, Min-Hwa;Kim, Shin-Keun
    • Journal of Pharmaceutical Investigation
    • /
    • v.22 no.3
    • /
    • pp.205-210
    • /
    • 1992
  • In order to develop a controlled-release oral drug delivery system (DDS) of theophylline (TP), microporous membrane-coated tablets were prepared and evaluated in vitro and in vivo. Rapidly water-soluble core tablets of TP (300 mg) were prepared by wet granulation and compression technique, Then the core tablets were spray-coated with polyvinylchloride (PVC) in which micronized sucrose particles were dispersed. Effect of formula compositions of coating suspensions on the pharmaceutical characteristics such as membrane strength and dissolution was investigated in vitro. The membranes remained unbroken in pH 1.2 buffer at $37^{\circ}C$ at least for 2 hours after the disintergration test. TP was released from the coated-released tablets at a zero-order rate over 8 hours. The release at pH 1.2 and 4.0 was similar in rate but a little more rapid than that at pH 6.8. The coated tablets were administered to three healthy male volunteers and their saliva profiles of TP were compared with those from the commercial sustained release TP tablets such as Slobid and Asconthin. Saliva TP concentrations from the coated tablets were successfully sustained over 48 hours after the dosing and were comparable to those of the commercial sustained-release tablets. The membrane-coating technique is very simple and does not need any sophisticated equipments. In this respect, the membrane-coated tablets may be superior to the commercial sustained-release tablets and this technique is worth adopting by the pharmaceutical industries.

  • PDF

Development of Controlled Release Oral Drug Delivery System by Membrane-Coating Method-I - Preparation and pharmaceutical evaluation of controlled release acetaminophen tablets-

  • Shim, Chang-Koo;Kim, Ki-Man;Kim, Young-Il;Kim, Chong-Kook
    • Archives of Pharmacal Research
    • /
    • v.13 no.2
    • /
    • pp.151-160
    • /
    • 1990
  • In order to develop a controlled-release oral drug delivery system (DDS) which sustains the plasma acetaminophen (AAP) concentration for a certain period of time, microporous membrane-coated tablets were prepared and evaluated in vitro. Firstly, highly water-soluble core tablet of AAP were prepared with various formulations by wet granulation and compression technique. Then the core tablets were coated with polyvinychloride (PVC) in which micronized sucrose particles were dispersed. Effect of formula compositions of core tablets and coating suspensions on the pharmaceutical characteristics such as drug release kinetics and membrane stability of the coated tablets was investigated in vitro. AAP was released from the coated tablets as a zero-order rate in a pH-independent manner. This independency of AAP release to pH change from 1.2 to 7.2 is favorable for the controlled oral drug delivery, since it will produce a constant drug release in the stomach and intestine regardless of the pH change in the GI tract. Drug release could be extended upto 10 h according to the coating condition. The release rate could be controlled by changing the formula compositions of the core tablets and coating suspensions, coat weight per each tablet, and especially PVC/sucrose ratio and particle size of the sucrose in the coating suspension. The coated tablets prepared in this study had a fairly good pharmaceutical characteristics in vitro, however, overall evaluation of the coated tablet should await in vivo absorption study in man.

  • PDF

Preparation and Properties of Sulfonated Polyvinylchloride (PVC) Membrane for Capacitive Deionization Electrode by Ultra Sonication Modification (초음파 표면개질에 의한 CDI 전극용 술폰화 염화비닐(PVC) 멤브레인의 제조 및 특성)

  • Hwang, Chi Won;Oh, Chang Min;Hwang, Taek Sung
    • Journal of Adhesion and Interface
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2014
  • Ion exchange membrane is widely used in various fields such as electro dialysis, diffusion dialysis, redox flow battery, fuel cell. PVC cation exchange membrane using ultrasonic modification was prepared by sulfonation reaction in various sulfonation times. Sulfuric acid was used as a sulfonating agent with ultrasonic condition. We've characterized basic structure of sulfonated PVC cation exchange membrane by FT-IR, EDX, water uptake, ion exchange capacity (IEC), electrical resistance (ER), conductivity, ion transport number and surface morphology (SEM). The presence of sulfonic groups in the sulfonated PVC cation exchange membrane was confirmed by FT-IR. The maximum values of water uptake, IEC, electrical resistance and ion transport number were 40.2%, 0.87 meq/g, $35.2{\Omega}{\cdot}cm^2$ and 0.88, respectively.