• 제목/요약/키워드: Polyvinyl fluoride bag

검색결과 2건 처리시간 0.016초

환원황화합물에 대한 용기채취법의 비교 연구 (Comparison of Two Experimental Approaches to Test Temporal Storability of Reduced Sulfur Compounds in Whole Sampling Method)

  • 조상희;김기현
    • 한국대기환경학회지
    • /
    • 제28권3호
    • /
    • pp.306-315
    • /
    • 2012
  • In this study, storage stability of reduced sulfur compounds ($H_2S$, $CH_3SH$, DMS, $CS_2$, and DMDS) and $SO_2$ in sampling bags was investigated in terms of two contrasting storage approaches between forward (F) and reverse (R) direction. The samples for the F method were prepared at the same time and analyzed sequentially through time. In contrast, those of reverse (R) method were prepared sequentially in advance and analyzed all at once upon the preparation of the last sample. In addition, relative performance between two different bag materials (PVF and PEA) was also assessed by using 100 ppb standard. The response factors (RF) of gaseous RSC samples were determined by gas chromatography/pulsed flame photometric detector (GC/PFPD) combined with air server (AS)/thermal desorber (TD) system at storage intervals of 0, 1, and 3 days. There is no statistical difference in all RSCs between two storage methods. However, the results of relative recovery indicated 2.58~12.8% differences in compound type between the two storage methods. Moreover, loss rates and storage stability of $H_2S$ and $SO_2$ were considerably affected by bag materials than any other variables. Therefore, some considerations about storage methods (or bag material types) for sulfur compounds are needed if stored by sampling bag method.

휘발성유기물(VOC) 분석을 위한 시료보관 용기의 비교 (Comparison of sample storage containers for the analysis of volatile organic compounds (VOC))

  • 김서경;김달호
    • 분석과학
    • /
    • 제35권3호
    • /
    • pp.116-123
    • /
    • 2022
  • 대기 중 휘발성유기물(VOC) 분석을 위해 가스시료 채취 용기로서 고분자 재질의 유연한 백(bag)이나 금속재질의 캐니스터 또는 유리병 등을 사용하고 있다. 본 연구에서는 가스시료 용기에 시료 채취 후 분석 시까지 단기 보관에 따른 휘발성시료의 농도 안정성을 다양한 용기에 대해 비교하였다. 시료용기로 폴리비닐플로라이드(polyvinyl fluoride, PVF), 폴리프로필렌(polypropylene, PP), 폴리에스터-알미늄(polyester aluminum, PE-Al) 재질의 폴리머백과 스테인레스 재질의 캐니스터 그리고 2종의 갈색유리병을 사용하였으며 VOC 시료로 100 nmol/mol의 벤젠, 톨루엔, 에틸벤젠, 자일렌, 스타이렌 표준가스를 사용하였다. 열탈착-가스크로마토그래프-불꽃이온화검출기(TD-GC-FID)를 사용하여 용기 종류별로 10~20일 동안 보관된 시료의 농도변화를 측정하였다. 캐니스터와 갈색병은 1주일 동안 큰 농도의 변화가 없었으며 2주까지도 처음 농도의 80 %이상 농도를 유지하였다. 폴리머재질의 모든 백(bag)형 용기의 경우는 벤젠과 톨루엔을 제외한 모든 성분이 1일 후에 처음 농도의 70 % 미만으로 큰 농도 변화를 보였다. 특히 에틸벤젠, 자일렌, 스티렌의 경우 처음 농도의 30 % 미만이 남아 매우 큰 농도 변화를 보였다.