• Title/Summary/Keyword: Polyvinyl chloride

Search Result 230, Processing Time 0.029 seconds

Effect of Different Variable Selection and Estimation Methods on Performance of Fault Diagnosis (이상진단 성능에 미치는 변수선택과 추정방법의 영향)

  • Cho, Hyun-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.551-557
    • /
    • 2019
  • Diagnosis of abnormal faults is essential for producing high quality products. The role of real-time diagnosis is quite increasing in the batch processes of producing high value-added products such as semiconductors, pharmaceuticals, and so forth. In this study, we evaluate the effect of variable selection and future-value estimation techniques on the performance of the diagnosis system, which is based on nonlinear classification and measurement data. The diagnostic performance can be improved by selecting only the variables that are important and have high contribution for diagnosis. Thus, the diagnostic performance of several variable selection techniques is compared and evaluated. In addition, missing data of a new batch, called future observations, should be estimated because the full data of a new batch is not available before the end of the cycle. In this work the use of different estimation techniques is analyzed. A case study on the polyvinyl chloride batch process was carried out so that optimal variable selection and estimation methods were obtained: maximum 21.9% and 13.3% improvement by variable selection and maximum 25.8% and 15.2% improvement by estimation methods.

Rating Evaluation of Fire Risk for Combustible Materials in Case of Fire (화재 시 연소성 물질에 대한 화재 위험성 등급 평가)

  • Chung, Yeong-Jin;Jin, Eui
    • Applied Chemistry for Engineering
    • /
    • v.32 no.1
    • /
    • pp.75-82
    • /
    • 2021
  • This study investigated the fire risk assessment of woods and plastics for construction materials, focusing on the fire performance index-III (FPI-III), fire growth index-III (FGI-III), and fire risk index-IV (FRI-IV) by a newly designed method. Japanese cedar, red pine, polymethylmethacrylate (PMMA), and polyvinyl chloride (PVC) were used as test pieces. Fire characteristics of the materials were investigated using a cone calorimeter (ISO 5660-1) equipment. The fire performance index-III measured after the combustion reaction was found to be 1.0 to 15.0 with respect to PMMA. Fire risk by fire performance index-III increased in the order of PVC, red pine, Japanese cedar, and PMMA. The fire growth index-III was found to be 0.5 to 3.3 based on PMMA. Fire risk by fire growth index-III increased in the order of PVC, PMMA, red pine, and Japanese cedar. COpeak concentrations of all specimens were measured between 106 and 570 ppm. In conclusion, it is understood that Japanese cedar with a low bulk density and PMMA containing a large amount of volatile organic substances have a low fire performance index-III and high fire growth index-III, and thus have high fire risk due to fire. This was consistent with the fire risk index-IV.

Installation Damage Assessment of Geogrids by Laboratory Tester (실내 시험기에 의한 지오그리드의 시공 시 손상 평가)

  • Jeon, Han-Yong;Jin, Yong-Bum;Jang, Yeon-Soo;Yoo, Chung-Sik
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.7
    • /
    • pp.77-86
    • /
    • 2007
  • Installation damage of 3 types of geogrids was evaluated with compaction condition by laboratory tester. This experimental was in accordance with ENV ISO 10722-1. First, soil distribution and water content were conducted. And then we changed cyclic loading time and type of geogrids as a factor of installation damage. The samples are woven, warp-knitted, welded type of 6, 8, 10T. This study aims to give an insight into the relationships between installation damage and cyclic loading time. The result of studies was that strength of the damaged geogrids can be closely correlated with the time of loading cycles. Especially, welded type shows slower slope than two types of geogrids due to coating materials. That means welded type is coated with PP (Polypropylene), but the other two types of geogrids are coated with PVC (Polyvinyl Chloride). To confirm another factor different method was performed. The size of soil was used between 9.5 mm and 23.5 m to compare initial experimental. Cyclic loading compaction is taken 200 times before installation test and the reason is that the reduction factor of this case by installation damage was higher than other compaction loading conditions.

Effects of Modified Atmosphere Packaging on the Quality of Chitosan and $CaCl_2$ Coated Mushroom (Agaricus bisporus) (환경가스조절 포장이 키토산 및 $CaCl_2$로 코팅 처리된 양송이 버섯의 품질에 미치는 영향)

  • Lee, Jin-Sil
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.5
    • /
    • pp.1308-1314
    • /
    • 1999
  • The effects of modified atmosphere(MA) packaging and coating on the quality of mushroom (Agaricus bisporus) were investigated. Whole mushrooms(100 g) were packed with polyvinyl chloride(PVC) film wrap, PD941 and PD961 film bags and were stored in a chamber at $12^{\circ}C$ and 80% RH for 6 days. Gas composition of packages, respiration rate, weight loss, color and maturity index of MA packaged mushrooms were examined. The wrap packaged mushrooms showed different level of internal $CO_2$ concentrations among water washed, chitosan coated and $CaCl_2$ coated subgroups significantly at 5% level. The maximum $CO_2$ concentration of PD941 and PD961 packages for all coated showed $4.1{\sim}4.7%$ and $10.4{\sim}11.7%$, respectively, for the first day. PD961 package showed the lowest $O_2$ concentration compared to other groups. There were no significant respiration rate differences between wrap packed and PD941 packaged. Respiration rate of water washed. chitosan coated and $CaCl_2$ coated in PD961 packaged was 192 mg, 226 mg and 245 mg, respectively. Maturity index of PD961 packaged were not significantly different among the water washed, chitosan and $CaCl_2$ coated packages. Chitosan coating showed a negative effect on color change of mushrooms. The weight loss of 961 packaged was lower $(7.0{\sim}8.0%)$ that those of wrap packaged and PD941 packaged.

  • PDF

Usefulness of modified ambu® in patients who need artificial ventilation (인공 환기가 필요한 환자에서 변형된 수동식 인공호흡기(Ambu®)의 유용성)

  • Ha, Kee Soo;Moon, Il Hong;Lee, Hee Sun;Shin, Dong Han;Eun, So Hee;Eun, Baik-Lin;Hong, Young Sook;Lee, Joo Won
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.11
    • /
    • pp.1194-1201
    • /
    • 2006
  • Purpose : The comatose mentality can be catastrophic, especially if the condition is severe or the duration is prolonged. Therefore, delayed diagnosis can result in a poor outcome or death. The best radiologic modality to differentiate from cerebral lesions in patients suffering from cerebral diseases is magnetic resonance imaging (MRI) rather than computed tomography (CT). Special apparatuses with metal materials such as ventilators, and cardiac pacemakers belonging to patients cannot be located in the magnetic field. We aimed to exhibit the possibility of examining MRI, maintaining ventilation at a relative long distance by means of modified $Ambu^{(R)}$. Methods : Self-inflating bags as a sort of a manual ventilator, connected with relatively long extension tubes instead of mechanical ventilators, were adopted to obtain MRI. PVC (polyvinyl chloride) extension tubes had different lengths and diameters. Lengths were 1, 2, and 3 cm and diameters were 15, and 25 mm. The work of breathing and expiratory changes of expiratory tidal volume (TVe), minute volume of expiration (MVe), peak inspiratory pressure (PIP) were measured by use of the mechanical ventilator, $Servoi^{(R)}$, as the alteration of TVi (inspiratory tidal volume), extension tube lengths and diameters with other values fixed. Results : Measured TVe and MVe by ventilator were the same values with control at every TVi, regardless of extension tube lengths and diameters, but PIP were increased with the rise of TVi, tube lengths, with decline of tube diameters, these were statistically significant. Conclusion : MRI examination can be carried out with a self-inflating bag connected with an extension tube at a long distance in patients who need artificial ventilation.

Growth kinetics and chlorine resistance of heterotrophic bacteria isolated from young biofilms formed on a model drinking water distribution system (모델 상수관망에 형성된 초기 생물막에서 분리한 종속영양세균의 생장 동역학 및 염소 내성)

  • Park, Se-Keun;Kim, Yeong-Kwan;Oh, Young-Sook;Choi, Sung-Chan
    • Korean Journal of Microbiology
    • /
    • v.51 no.4
    • /
    • pp.355-363
    • /
    • 2015
  • The present work quantified the growth of young biofilm in a model distribution system that was fed with chlorinated drinking water at a hydraulic retention time of 2 h. Bacterial biofilms grew on the surface of polyvinyl chloride (PVC) slides at a specific growth rate of $0.14{\pm}0.09day^{-1}$ for total bacteria and $0.16{\pm}0.08day^{-1}$ for heterotrophic bacteria, reaching $3.1{\times}10^4cells/cm^2$ and $6.6{\times}10^3CFU/cm^2$ after 10 days, respectively. The specific growth rates of biofilm-forming bacteria were found to be much higher than those of bulk-phase bacteria, suggesting that biofilm bacteria account for a major part of the bacterial production in this model system. Biofilm isolates exhibited characteristic kinetic properties, as determined by ${\mu}_{max}$ and $K_S$ values using the Monod model, in a defined growth medium containing various amounts of acetate. The lowest ${\mu}_{max}$ value was observed in bacterial species belonging to the genus Methylobacterium, and their slow growth seemed to confer high resistance to chlorine treatment (0.5 mg/L for 10 min). $K_S$ values (inversely related to substrate affinity) of Sphingomonas were two orders of magnitude lower for acetate carbon than those of other isolates. The Sphingomonas isolates may have obligate-oligotrophic characteristics, since the lower $K_S$ values allow them to thrive under nutrient-deficient conditions. These results provide a better understanding and control of multi-species bacterial biofilms that develop within days in a drinking water distribution system.

Case Study on Determination of the Level of New RoHS II Substances in Domestic Electronic and Electrical Equipments (국내 전기전자 제품에 함유된 신규 RoHS II 물질 검출 사례 연구)

  • Song, Moon-Hwan;Son, Seung-Hwan;Cho, Young-Dal;Choe, Eun-Kyung
    • Clean Technology
    • /
    • v.17 no.2
    • /
    • pp.124-133
    • /
    • 2011
  • In addition to six substances regulated in EU RoHS including lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB) and polybrominated diphenyl ethers (PBDE), priority substances are identified in new RoHS II as hexabromocyclododecane (HBCDD), dibutyl phthalate (DBP), butyl benzyl phthalate (BBP) and diethylhexyl phthalate (DEHP). In this study, 20 plastic samples were collected from 12 domestic electrotechnical companies and levels of four restricted substances were determined by gas chromatography-mass spectrometry, Among 20 parts that compose washer, refrigerator or microwave oven, HBCDD was detected in three samples of NBR material with the amount of 42~381 mg/kg while DBP and BBP was not detected in any samples collected respectively, implying that these substance may not be used widely in plastic materials for EEE. However, DEHP was detected in all samples of NBR, PP, PBT, EPDM and PVC materials with the amount of 42 up to 59,400 mg/kg that exceeds the limit value of 0.1 wt% (1,000 mg/kg). Presence of a restricted substance in polymer material makes a great negative influence on a number of final product. To cope with coming RoHS II as well as REACH, action not to use DEHP in plastic material or the relevant notification in case of REACH seems to be needed. Screening test of Arsenic compounds such as diarsenic pentaoxide, diarsenic trioxide, lead hydrogen arsenate, triethyl arsenate that are included in REACH SVHC was done by ICP measurement Arsenium was detected in four samples made of NBR and PBT materials in the level of 15~700 mg/kg. By considering the screening method used in this study, the amount of arsenium compounds in the thermistor made of PBT material has a high chance of exceeding the regulated limit value.

Determination of the Levels of Bisphenol A Diglycidyl Ether (BADGE), Bisphenol F Diglycidyl Ether (BFDGE) and Their Reaction Products in Canned Foods Circulated at Korean Markets (캔 제품의 bisphenol A diglycidyl ether (BADGE), bisphenol F diglycidyl ether (BFDGE) 유도체 및 분해산물 분석법)

  • Kim, Hee-Yun;Lee, Jin-Sook;Cho, Min-Ja;Yang, Ji-Yeon;Baek, Ji-Yun;Cheong, So-Young;Choi, Sun-Hee;Kim, Young-Seon;Choi, Jae-Chun
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.1
    • /
    • pp.8-13
    • /
    • 2010
  • Bisphenol A diglycidyl ether (BADGE) and bisphenol F diglycidyl ether (BFDGE) were obtained by a polymerization reaction of epichlorohydrin (ECH) with bisphenol A (BPA) or bisphenol F (BPF). These compounds are commonly used as monomers or additives such as a polymerization stabilizer and a hydrochloric acid scavenger of epoxy resin, polyvinyl chloride (PVC)-containing organosols and polyester lacquers, that are applied to the internal surface of most canned foods to impart chemical resistance. The unreacted BADGE, BFDGE and their reaction products migrating from epoxy resin, PVC-containing organosol and/or polyester lacquer-based food packaging materials into the foods have recently become an issue of great concern because of increased customer demand for safety. This study was conducted to develop a rapid and sensitive simultaneous analysis method based on HPLC/FLD and HPLC/APCI-mass and to evaluate the concentration of BADGE, BFDGE and their metabolites, BADGE $H_2O$, BADGE $2H_2O$, BADGE HCl, BADGE 2HCl, BADGE HCl $H_2O$, BFDGE $H_2O$, BFDGE $2H_2O$, BFDGE HCl, BFDGE 2HCl and BFDGE HCl $H_2O$ for 133 canned food samples. The method provided a linearity of 0.9997-0.9999, a limit of detection of $0.01-0.13\;{\mu}g/mL$, a limit of quantitation of $0.03-0.44\;{\mu}g/mL$ and a recovery (%) of 85.64-118.18. The number of samples containing BADGE, BFDGE or their metabolites were: 28/133 (21.1%), with levels of 0.400-0.888 mg/kg being observed for aqueous foods (19/133) and 0.093-0.506 mg/kg being observed for oily foods (9/133).

A Study on the Nutritional Assessment and the Effects of Enteral Nutritional Supports of Tube Feeding In-patients (경관급식 중인 입원환자의 영양상태 평가와 영양 보충제 투여의 영향에 관한 연구)

  • 윤숙영;김성미
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.25 no.5
    • /
    • pp.855-864
    • /
    • 1996
  • The purpose of this study is to evaluate nutritional status of tube feeding patients, and to investigate the effects of giving enteral nutritional support to them. 83 in-patients have been examined for their nutritional status. The mean caloric density was 0.77kca1/m1. 36.1% to 75.9% of them were malnourished in terms of biochemical assessment. The energy intake showed the significant and positive correlation in all biochemical parameters. And the protein intake showed the significant and positive correlation in total protein, serum albumin, serum iron, hemoglobin, hematocrit and TLC. But age was correlated negatively to serum albumin and transferrin. The amount of energy and protein intake has been significantly increased as the tube feeding duration became longer. Also the effect of enteral nutritional support for 6 weeks has been investigated. Case group(n=8) was administered 250kca1 of polymeric formula in addition to their usual diet, while control group(n=8) kept the amount of their original intake. When comparing the biochemical changes of the case group and those of control group at week 0 and week 6 respectively, it showed significant differences in total protein, serum transferrin and TLC. This study suggests that the malnourished status of tube feeding patients can be improved and even prevented if nutritional support is properly administered.

  • PDF

Growth Characteristics of Juvenile Abalone, Haliotis discus hannai by Reared Methods in order to High Density Intermediate Culture in Land-based Tank (육성수조 내 북방전복, Haliotis discus hannai 치패 고밀도 중간양성 사육방식별 성장특성)

  • Lee, Si-Woo;Kim, Byeong-Hak;Park, Min-Woo;Kim, Tae-Ik;Son, Maeng-Hyun
    • The Korean Journal of Malacology
    • /
    • v.31 no.2
    • /
    • pp.83-92
    • /
    • 2015
  • The effect of different intermediated rearing method by expanding the attached floor space in order to highly density culture on the growth characteristics and survival rate of the juvenile abalone, Haliotis discus hannai, were investigated in land-based tanks. The intermediated culture methods was determined thru the shelter counts and layer for 10 month with two replicates : the single layer shelter (SLS), the double layer shelter (DLS), the triple layer shelter (TLS) and the single layer shelter under net cage (SLSNC). In addition, the culture on shallow race way tank had to set up as culture of the ditch raceway tank (CDRT) and the floor race way tank (CFRT). In the growth performance of reared abalone (initial mean shell length $54.18{\pm}7.39mm$ and weight $1.93{\pm}0.14g$) at experimental tanks, that the absolute growth rate (ARG), daily growth rate (DGR) and specific growth rate (SGR) to the shell length and shell breadth was not significant at each experimental tanks except SLSNC. As well as too, weight gain (WG), daily weight gain (DWG) and specific weight gain (SWG) to weight was not significant at each experimental tanks except SLSNC, too. Survival rates of CDRT and CFRT was lower than those of different experimental tanks (P < 0.05). Therefore, these results is showed that high density different intermediated rearing method by expanding the attached floor space for juvenile H. discus hannai was not have difference as growth performance and survival rate both one layer shelter and multi layer shelter. Also, it is considered that shallow race way tank was not useful rearing for the juvenile intermediate culture of H. discus hannai in land based.