• Title/Summary/Keyword: Polyurethane

Search Result 1,611, Processing Time 0.031 seconds

Parametric Study on Gloss Property of UV Curable Coated Steel (자외선 코팅 강판의 광택도에 미치는 공정 변수에 대한 연구)

  • Hwang, Dong Seop;Cho, Dong Chul;Yoo, Hye Jin;Kim, Jong Sang;Cheong, In Woo
    • Journal of Adhesion and Interface
    • /
    • v.15 no.3
    • /
    • pp.116-122
    • /
    • 2014
  • This work deals with the effects of different oligomers, monomers, photoinitiators, and steel plates on the variation of gloss for UV coated steel plates at $20^{\circ}$ and $60^{\circ}$ (ASTM D523). The gloss value was more significantly varied with $20^{\circ}$ angle as compared with $60^{\circ}$. No substantial change in gloss was observed for the type of single oligomer; however, the gloss varied with the mixing ratios of oligomers, type and mixing ratio of monomers, type and concentration of photoinitiator, and type of steel plate. The maximum gloss value was observed when the mixing ratio of polyurethane acrylate (UA) to epoxy acrylate (EA) was 70 : 30, the mixing ratio of trimethylolpropantriacrylate (TMPTA) to tetrahydrofurfurylacrylate (THFA) was 5 : 5, the content of the mixed oligomer (UA : EA = 70 : 30) was 90 wt%, respectively. Darocur MBF of liquid type showed better gloss property than the solid type of Irgacure 184, and the gloss was decreased as the concentration of Darocur MBF increased from 1 to 4 wt%. Regarding the type of steel plate, GI steel plate showed better gloss property as compared with EG and primer-coated steel plates. The maximum gloss values of 95 GU and 120 GU, respectively, at $20^{\circ}$ and $60^{\circ}$ angles throughout the parametric study in the absence of leveling agents enhancing the gloss.

Drug Adsorption Behavior of Polyolefin Infusion Tube Compared to PVC and PU (Non-PVC(폴리올레핀) 수액용 튜브 내면에서의 약물흡착 거동 - PVC 및 PU 수액튜브와의 비교)

  • Park, Kang Hoon;Park, Chang Kyu;Park, Jong;Jeon, Seungho;Bang, Sa-Ik;Kim, Ji-Heung;Chung, Dong June
    • Polymer(Korea)
    • /
    • v.38 no.3
    • /
    • pp.333-337
    • /
    • 2014
  • PVC (polyvinyl chloride) intravenous fluid bags and tubes that contain DEHP (diethylhexyl phthalate) as a plasticizer have several associated disadvantages for intravenous injections. We investigated the drug absorption behaviors on the inner surface of an infusion tube that consisted of commercialized PVC/PU (polyurethane). We developed a non-PVC (polyolefin) tube in order to improve the efficacy of this drug administration method. We prepared four types of non-PVC (polyolefin) infusion tubes using a polyethylene (PE), polypropylene (PP), syndiotactic 1,2-polybutadiene (PB), and styrene-ethylene (SE) copolymer elastomers were prepared using a single screw extruder. The four types of manufactured non-PVC (polyolefin) infusion tubes had good mechanical properties that were equivalent to PVC tube properties. The four types of prepared non-PVC (polyolefin) infusion tubes also prohibited drug absorption when compared to the commercialized PVC and PU tubes. Therefore, based on the results of this study, prepared non-PVC (polyolefin) tubes are good candidates for infusion because they prevent drug absorption and the release of DEHP.

Mechanical evaluation of the use of conventional and locking miniplate/screw systems used in sagittal split ramus osteotomy

  • Santos, Zarina Tatia Barbosa Vieira;Goulart, Douglas Rangel;Sigua-Rodriguez, Eder Alberto;Pozzer, Leandro;Olate, Sergio;Albergaria-Barbosa, Jose Ricardo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.43 no.2
    • /
    • pp.77-82
    • /
    • 2017
  • Objectives: The aim of this study was to compare the mechanical resistance of four different osteosyntheses modeled in two different sagittal split ramus osteotomy (SSRO) designs and to determine the linear loading in a universal testing machine. Materials and Methods: An in vitro experiment was conducted with 40 polyurethane hemimandibles. The samples were divided into two groups based on osteotomy design; Group I, right angles between osteotomies and Group II, no right angles between osteotomies. In each group, the hemimandibles were distributed into four subgroups according to the osteosynthesis method, using one 4-hole 2.0 mm conventional or locking plate, with or without one bicortical screw with a length of 12.0 mm (hybrid technique). Each subgroup contained five samples and was subjected to a linear loading test in a universal testing machine. Results: The peak load and peak displacement were compared for statistical significance using PASW Statistics 18.0 (IBM Co., USA). In general, there was no difference between the peak load and peak displacement related to osteotomy design. However, when the subgroups were compared, the osteotomy without right angles offered higher mechanical resistance when one conventional or locking 2.0 mm plate was used. One locking plate with one bicortical screw showed higher mechanical resistance ($162.72{\pm}42.55N$), and these results were statistically significantly compared to one conventional plate with monocortical screws (P=0.016) and one locking plate with monocortical screws (P=0.012). The difference in peak displacement was not statistically significant based on osteotomy design or internal fixation system configuration. Conclusion: The placement of one bicortical screw in the distal region promoted better stabilization of SSRO. The osteotomy design did not influence the mechanical behavior of SSRO when the hybrid technique was applied.

Shape Design of Bends in District Heating Pipe System by Taguchi Method (다구찌 방법을 이용한 지역난방시스템의 벤드형상 설계)

  • Choi, Moon-Deok;Kim, Joo-Yong;Ko, Hyun-Il;Cho, Chong-Du
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.3
    • /
    • pp.307-313
    • /
    • 2010
  • In this study, alternative designs for the bends used in district heating pipes are investigated. The district heating pipes, which are subjected to temperatures of 10 to $120^{\circ}C$ and a water pressure of $16\;kgf/cm^2$, have to withstand thermomechanical cyclic loads when in use. These pipes comprise three concentric tubes: a steel pipe (internal), polyurethane (PUR) insulator (middle), and a high-density polyethylene (HDPE) case (external). In addition, the bends in the district heating pipe system are covered with foam pads that cause aging. In this study, an alternative bend design that does not involve the use of a foam pad is proposed to overcome the aging problem in the bends. In the proposed design, "shear rings" are added to the surface of a bend, and its dimensions are determined by a combination of the statistical (Taguchi) method and FEM. The geometrical parameters such as thickness, height, and number of the rings significantly affect the design optimization, and hence, they affect the results of the FEM.

Synthesis of Polyester Polyols by Using Double Metal Cyanide Catalyst and Physical Properties of Polyurethanes Produced by the Polyols (이중금속시안염 촉매에 의한 폴리에스테르 폴리올 제조 및 이를 이용한 폴리우레탄의 물성)

  • Kim, In-Ki;Seo, Hyun-Sook;Ha, Chang-Sik;Park, Dae-Won;Kim, Il
    • Clean Technology
    • /
    • v.14 no.1
    • /
    • pp.29-34
    • /
    • 2008
  • Copolymerizations of propylene oxide (PO) and phthalic anhydride (PA) have been performed in the presence of double metal cyanide (DMC) catalyst as a means of incorporating ester groups in the polyol backbone. DMC catalyst was effective for the copolymerization and the reactivity ratios measured by modified Kelen-$T{\ddot{u}}d{\ddot{o}}s$ equation were $r_1(PA)\;=\;0$, and $r^2(PO)\;=\;0.248$. Four different Polyol samples containing 1.0, 2.1, 7.52, and 11.42 mol% of PA unit were utilized for the synthesis of thermoplastic polyurethanes of their hard segments of 19 wt%. As the incorporated amount of PA increases, the elongation of the resulting polyurethane decreases and the tensile strength and the tensile modulus increase. The modulation of the incorporated amount of PA into polyol backbone was proven to be a feasible way to tune the physical properties of polyurethanes.

  • PDF

A Study on Formation and Thermal Decomposition Kinetics of PU Elastomers by Dynamic DSC and TGA Analysis (Dynamic DSC 및 TGA 열분석을 이용한 PU Elastomer의 중합반응 및 열분해 반응 Kinetics에 관한 연구)

  • Yoon, Soo-Koong;Ahn, Won-Sool
    • Elastomers and Composites
    • /
    • v.42 no.1
    • /
    • pp.47-54
    • /
    • 2007
  • Reaction kinetics of polyurethane elastomers (PU) were studied using dynamic DSC and TGA for three PU samples of general purpose (Sample A), high temperature cross-likable CASE purpose with MOCA (Sample B), and RT cross-likable CASE purpose grade (Sample C). From DSC results, sample with MOCA(Sample B) showed lower shift of peak temperature, while showing broader thermograms than those of general purpose grade (Sample A). On the other hand, RT cross-linkable PU grade (Sample C) showed an interesting double mode reaction patterns, i.e., a lower temperature reaction at about $70\;^{\circ}C$, and a higher temperature reaction in the range of $140{\sim}170\;^{\circ}C$, indicating that it requires 2-step reaction process in order to complete the reaction. Once the cross-linking reaction completed, however, TGA results showed that all the samples would be considered to have similar chemical structures, showing similar decomposition processes. Sample C, especially, had showed decomposition properties of both Sample A and Sample B. Formation activation energies calculated from Kissinger method showed 10.39, 65.85, 36.52(Low $T_p$) and 18.21(High $T_p$) kcal/mol, while decomposition activation energies were 31.94, 30.84, 24.16 kcal/mol, respectively.

Selection of Biofilter Support for Removing MEK (MEK 제거를 위한 바이오필터용 담체의 선택)

  • Jeong Gwi-Taek;Lee Gwang-Yeon;Lee Kyoung-Min;Sunwoo Chang-Shin;Lee Woo-Tae;Jung Seong-Ho;Cha Jin-Myoung;Jang Young-Seon;Park Don-Hee
    • KSBB Journal
    • /
    • v.21 no.1 s.96
    • /
    • pp.34-41
    • /
    • 2006
  • The aim of this study is the development of biological removal process of methyl ethyl ketone (MEK) in odor gas, which is generated from the waste food recycling process. To develop the removal process of odor gas, MEK, the selection of proper biofilter support was carried out. When the biofilter equipment was passed by synthetic odor gas composed of 250 ppm of MEK, the maximum removal was achieved to $586.6g-MEK/m^3\;hr$ for polypropylene fibril as support. Under the same experimental conditions, the maximum removal in polyurethane support was obtained to $359.7 g-MEK/m^3\;hr$. Finally, the maximum removal in volcanic stone support was $56.2g-MEK/m^3\;hr$.

A New Method for Enhancement of Right-Left Pump Output Balance in the Totally Implantable Artificial Heart (완전이식형 인공심장의 좌,우 심박출량 균형의 개선에 관한 연구)

  • Choe, Won-U;Kim, Hui-Chan;Kim, Won-Gon;No, Jun-Ryang;Kim, In-Yeong;Min, Byeong-Gu
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.4
    • /
    • pp.385-391
    • /
    • 1998
  • A new balancing method of atrial pressures balancing for the moving actuator total artificial heart(TAH) without an extra compliance chamber was developed. The asymmetric operation of the pendulous moving actuator have made it possible to compensate the left and right pump output difference by utilizing the interventricular air space as an internal compliance chamber in a pump housing. Furthermore, the balancing performance between left and right pump outputs is increased through the improvement of the flexibility of part of the polyurethane housing. However, the increase of the flexibility of the pump housing causes a little loss of the cardiac output due to the reduction of active filling property. In this paper., a good condition between the balance and pump output performance is evaluated by adjusting the air volume in the interventricular space through a series of in vitro experiments. This new pump was implanted in a sheep weighting 63kg, and it survived for 3 days and the average cardiac output during postoperative days was about 4.2 L/mim with the atrial pressures under 15 mmHg.

  • PDF

Design of a Prototype System for Graft-Taking Enhancement of Grafted Seedlings Using Artificial Lighting - Effect of air current speed on the distribution of air temperature and relative humidity in a graft-taking enhancement system (인공광을 이용한 접목표 활착촉진 시스템의 시작품 설계 - 활착촉진 시스템 내의 기온과 상대습도 분포에 미치는 기류속도의 효과)

  • 김용현
    • Journal of Biosystems Engineering
    • /
    • v.25 no.3
    • /
    • pp.213-220
    • /
    • 2000
  • Grafting of fruit-bearing vegetables has been widely used to increase the resistance to soil-borne diseases, to increase the tolerance to low temperature or to soil salinity, to increase the plant vigor, and to extend the duration of economic harvest time. After grafting, it is important to control the environment around grafted seedlings for the robust joining of a scion and rootstock. Usually the shading materials and plastic films are used to keep the high relative humidity and low light intensity in greenhouse or tunnel. It is quite difficult to optimally control the environment for healing and acclimation of grafted seedlings under natural light. So the farmers or growers rely on their experience for the production of grafted seedling with high quality. If artificial light is used as a lighting source for graft-taking of grafted seedlings, the light intensity and photoperiod can be easily controlled. The purpose of this study was to develop a prototype system for the graft-taking enhancement of grafted seedlings using artificial lighting and to investigate the effect of air current speed on the distribution of air temperature and relative humidity in a graft-taking enhancement system. A prototype graft-taking system was consisted by polyurethane panels, air-conditioning unit, system controller and lighting unit. Three band fluorescent lamps (FL20SEX-D/18, Kumho Electric, Inc.) were used as a lighting source. Anemometer (Climomaster 6521, KANOMAX), T-type thermocouples and humidity sensors (CHS-UPS, TDK) were used to measure the air current speed, air temperature and relative humidity in a graft-taking system. In this system, air flow acted as a driving force for the diffusion of heat and water vapor. Air current speed, air temperature and relative humidity controlled by a programmable logic controller (UP750, Yokogawa Electric Co) and an inverter (MOSCON-G3, SAMSUNG) had an even distribution. Distribution of air temperature and relative humidity in a graft-taking enhancement system was fairly affected by air current speed. Air current speed higher than 0.1m/s was required to obtain the even distribution of environmental factors in this system. At low air current speed of 0.1m/s, the evapotranspiration rate of grafted seedlings would be suppressed and thus graft-taking would be enhanced. This system could be used to investigate the effects of air temperature, relative humidity, air current speed and light intensity on the evaportranspiration rate of grafted seedlings.

  • PDF

Exposure Characteristics of Construction Painters to Organic Solvents

  • Park, Hyunhee;Park, Hae Dong;Jang, Jae-Kil
    • Safety and Health at Work
    • /
    • v.7 no.1
    • /
    • pp.63-71
    • /
    • 2016
  • Background: Construction painters have not been studied well in terms of their hazards exposure. The objective of this study was to evaluate the exposure levels of total volatile organic compounds (TVOCs) for painters in the construction industry. Methods: Activity-specific personal air samplings were carried out in three waterproofing activities [polyurethane (PU), asphalt, and cement mortar] and three painting activities (epoxy, oil based, and water based) by using organic-vapor-monitor passive-sampling devices. Gas chromatograph with flame ionization detector could be used for identifying and quantifying individual organic chemicals. The levels of TVOCs, by summing up 15 targeted substances, were expressed in exposure-index (EI) values. Results: As arithmetic means in the order of concentration levels, the EIs of TVOCs in waterproofing works were 10.77, 2.42, 1.78, 1.68, 0.47, 0.07, and none detected (ND) for indoor PU-primer task, outdoor PU-primer task, outdoor PU-resin task, indoor PU-resin task, asphalt-primer task, asphalt-adhesive task, and cement-mortar task, respectively. The highest EI for painting works was 5.61 for indoor epoxyprimer task, followed by indoor epoxy-resin task (2.03), outdoor oil-based-spray-paint task (1.65), outdoor water-based-paint task (0.66), and indoor oil-based-paint task (0.15). Assuming that the operations were carried out continuously for 8 hours without breaks and by using the arithmetic means of EIs for each of the 12 tasks in this study, 58.3% (7 out of 12) exceeded the exposure limit of 100% (EI > 1.0), while 8.3% (1 out of 12) was in 50e100% of exposure limit (0.5 > EI > 1.0), and 4 tasks out of 12 were located in less than 50% of the limit range (EI < 0.5). Conclusion: From this study, we recognized that construction painters are exposed to various solvents, including carcinogens and reproductive toxins, and the levels of TVOC concentration in many of the painting tasks exceeded the exposure limits. Construction workers need to be protected from chemical agents during their painting works by using personal protective devices and/or work practice measures. Additional studies should focus on the exposure assessment of other hazards for construction workers, in order to identify high-risk tasks and to improve hazardous work environments.