• 제목/요약/키워드: Polymeric insulators

검색결과 55건 처리시간 0.025초

옥외용 실리콘 고무의 표면 열화 특성 연구 (The Study on Properties of Surface Degradation of Silicone Rubber for Outdoor Use)

  • 서광석;김정호;송우창;문중섭;박용관;유영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2302-2304
    • /
    • 1999
  • The application of polymeric insulators for outdoor use has been increasing as a new replacement of overhead line in abroad. In domestic case, it is actively going on the research of polymeric insulators. The Silicone rubber among polymeric insulators have a good electrical properties, due to surface hydrophobicity. This paper is concentrated on the recovery of surface hydrophobicity and the change of surface construction after electrical stress. The feature of silicone rubber, a good hydrophobicity, is demanded the improvement method as the estimation of the non-ceramic insulators like it.

  • PDF

Tracking/Erosion Resistance Analysis of Nano-Al(OH)3 Filled Silicone Rubber Insulating Materials for High Voltage DC Applications

  • Kannan, P.;Sivakumar, M.;Mekala, K.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.355-363
    • /
    • 2015
  • HVDC technology has become popular as an economic mode of bulk power transmission over very long distances. Polymeric insulators in HVDC power transmission lines are affected by surface tracking and erosion problems due to contamination deposit, which pose a greater challenge in maintaining the reliability of the HVDC system. In addition, polymeric insulators are also naturally affected by aging due to various environmental stresses, which in turn accelerates the surface tracking and erosion problems. Research works towards the improvement of tracking and erosion resistance of polymeric insulators by adding nano-sized fillers in the base material are being carried out worldwide. However, surface tracking and erosion performance of nano-filled aged polymeric insulators for HVDC applications are not well reported. Hence, in the present work, tracking and erosion resistance of the nano $Al(OH)_3$ filled silicone rubber insulation material has been evaluated under DC voltages at different filler concentrations and aged conditions, as per IEC 60587 test procedures. Leakage current and contact angle measurements were carried out to understand the surface hydrophobicity. Moving average technique was used to analyze the trend followed by leakage current. Water aged specimen shows less tracking resistance when compared with thermal aged specimen. It is observed that nano-filler concentration of 5% is even sufficient to get better tracking/erosion resistance under DC voltages.

송전용 애자의 산불영향에 따른 특성 연구 (A study of the forest Fire Influence on the Insulator Characteristics for T/L)

  • 최인혁;최장현;이동일;정용운;유근양
    • 조명전기설비학회논문지
    • /
    • 제19권2호
    • /
    • pp.138-144
    • /
    • 2005
  • 본 논문에서는 산불이 송전용 폴리머애자에 미치는 영향을 연구하기 위해 인공화염 시험장치를 제작하여 화염의 가열 시간에 따른 폴리머애자의 갓(shed) 변화와 자기애자의 disc 변화를 관찰하고, 전기적$\cdot$기계적 실험을 통하여 특성변화를 확인하였다. 실험결과 다음과 같은 결론을 얻을 수 있었다. 첫째, 화염의 가열시간이 5분정도 경과하였을 때, 자기애자의 전기적 특성은 $80(\%)$ 정도 저하된 반면에 폴리머애자의 경우 갓 유실이 있었지만 전기적 특성의 변화는 $10(\%)$ 정도였다. 폴리머애자를 20분 가열하였을 때는 대부분의 갓이 유실되었지만 전기적 특성치는 $20(\%)$ 정도 감소하였다. 둘째, 폴리머애자와 자기애자 모두 전기적 특성치의 감소는 있었지만 기계적 특성치는 양호하게 나타났다.

주위 환경 변화 따른 폴리머 절연재료의 표면 누설전류 (The Study of Leakage Current Distributions of Plymeric Insulators will Changing Environment)

  • 이병성;한재홍;김주용;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.88-91
    • /
    • 2001
  • Our knowledge about their long-term performance in an outdoor environment is still very limited. The electrical stress caused the surface of these insulators to become degradation. In order to evaluate leakage current patterns caused by surface aging on polymeric insulators, we utilized the combined aging test facility and leakage current monitoring system. And we get the continuous leakage current values from each sample. After completing the 3000h combined aging cycle test, leakage current measurement were conducted for these samples and carried out harmonics analysis for its data.

  • PDF

전차 선로용 폴리머 현수애자의 적용 기술 (Application Technologies of Polymer Suspended Insulators for the Electric Track Line)

  • 한세원;조한구;송홍준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.59-61
    • /
    • 2001
  • Polymeric suspended insulators for the electric track line have been developed. The main elements to design polymeric insulators are the insulation ability related with materials of FRP core and housing, and the optimal structure related with fitting parts and interface characteristics. To confirm the design fitness of insulator samples the electric field distribution by FEM and mechanical stress distribution by NASTRAN program was analysed with housing shed shapes and fitting structure. The leakage distance and breakage voltage properties which are core parameters to determine electric insulation ability are selected according to the requirement values of user specification, then the power frequency wet withstand voltage was specified above 22kV and the leakage distance was required above 290mm. The contamination condition of the electric track line was the heavy class according to IEC 815 in order to retain the enough safety margin against overvoltages.

  • PDF

코로나 대전을 통한 옥외용 고분자 절연재료의 자외선 열화특성 연구 (Study on UV degradation in Polymeric Insulating Materials for Use in Outdoor Insulators by Corona-Charging)

  • 연복희;안종식;이상용;허창수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.106-109
    • /
    • 2001
  • In this paper, we have investigated the degradation of shed materials of outdoor insulators by UV-radiation by using corona-charging and XPS analysis. The accumulated charges on polymeric surface having intrinsic hydrophobic property have a negative impact on retaining its hydrophobicity. Therefore, shorter decay times of surface charges are preferred. The surface voltage decay on UV-treated silicone rubber and EPDM show a different decay trend with UV treated time. From the XPS analysis, the oxidized groups of silica-like structure in silicone rubber increase with UV treatment time. For EPDM, the oxidized carbon groups of C=O, O=C-O increase as elapse of UV radiation time. These oxidized surface for each material have different electrostatic characteristics, so deposited charges may be expected to have different impacts on their surface hydrophobicity. The degradation mechanism based on our results is discussed.

  • PDF

S-Transform Based Time-Frequency Analysis of Leakage Current Signals of Transmission Line Insulators under Polluted Conditions

  • Natarajan, A.;Narayanan, Suthanthiravanitha
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.616-624
    • /
    • 2015
  • Flashover of power transmission line insulators due to contamination is a major threat to the reliable operation of power system. This paper deals with the analysis of leakage current characteristics of polymeric insulator using S-Transform technique in order to develop a better diagnostic tool to identify the surface condition of outdoor polymeric insulators. In this work, experiments were carried out on 11 kV silicone rubber insulator under AC voltage at different pollution levels. Moving average technique was adopted to find the trend followed by LC peak at different relative humidity conditions. S-Transform was used to find the relationship between energy and frequency content of the leakage current signal with respect to increase in pollution level over a period of time. From the S-Transform time-frequency contour analysis, point of transition to severe arcing due to increase in pollution and its thershold limit were evaluated. Reported results show that the surface condition of insulators could be easily identified from the S-Transform time-frequency analysis of leakage current signals.

Leakage Current Waveforms of Outdoor Polymeric Insulators and Possibility of Application for Diagnostics of Insulator Conditions

  • Suwarno Suwarno
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권1호
    • /
    • pp.114-119
    • /
    • 2006
  • This paper reports the investigation results on the leakage currents (LC) on polymeric outdoor insulators. The samples used were EPDM (ethylene prophylene diene monomer) insulators used at 20 kV distribution lines. AC voltage was applied and the LC waveforms were measured under various environmental conditions (humidity and pollution). Digital data of the LC was transferred from a digital storage oscilloscope to a computer for further analysis. The LC waveform parameters such as magnitude and harmonic content (as indicated by the total harmonic distortion (THD)) were analyzed. The experimental results showed that 3rd, 5th and 7th harmonics and higher odd harmonics were observed for symmetrical-distorted LC waveforms while for unsymmetrical-distorted LC waveforms, odd and even harmonics were observed. The LC analysis indicated that there are 5 stages of insulator conditions from normal condition up to flashover correlated with different kind of LC waveforms. The results also showed that in general the magnitude of LC was good enough to show the condition of the insulators. However, under discharge condition (for example as a result of dry band arching) the LC magnitude should be combined by the THD to show a better correlation with the insulator condition. The product between THD and LC magnitude may be used as a diagnostic parameter.

옥외용 고분자 절연재료의 자외선 열화특성 연구 (A Study on the Ultraviolet Aging Characteristics of Outdoor Polymeric Insulating Materials)

  • 김영성;정순옥
    • 한국재료학회지
    • /
    • 제9권4호
    • /
    • pp.409-413
    • /
    • 1999
  • Recently, the polymeric insulators have been accepted in several countries for the outdoor high voltage applications. In comparison with the conventional porcelain, polymeric insulators offer various advantages such as light weight, superior vandal resistance and better contamination performance. The outdoor polymeric insulating materials such as silicone rubber, ethylene propylene diene monomer(EPDM), ethylene vinyl acetate(EVA) and epoxy are aged such as silicone rubber, ethylene propylene diene monomer(EPDM), ethylene vinyl acetate(EVA) and epoxy are aged under the various natural environment with the long-term performance in outdoor. In this paper, the effects of UV-under the various natural environment with the long-term performance in outdoor. In this paper, the effects of UV-ray on the surface of silicone rubber were investigated by using the weather-Ometer. The accelerated aging stresses were simulated by UV radiation, high temperature and humidity as well as water spray. These aging characteristics were examined through contact angle measurements, tracking resistance test, FT-IR and SEM/EDS analysis. The experimental results showed that tracking resistance decreases with increase in the UV-ray irradiation period. But the surface of silicone rubber kept hydrophobicity. It is found that the inorganic filler such as)$ Al(OH_3$ improves tracking resistance and the $Tio_2$is very effective in preventing degradation of silicone rubber surface from UV-ray.

  • PDF

배전용 폴리머애자 열화특성 평가를 위한 복합열화 시험장치 구축 (A Combined Aging Test Facility for Evaluating an Aging Characteristics of Distribution Polymer Insulators)

  • 이병성;한재홍;김찬영;윤태상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1948-1950
    • /
    • 2000
  • Polymeric composite insulators have been in use for outdoor insulation. However, our knowledge about their long-term performance in an outdoor environment is still very limited. Especially, these insulators are subjected to the environmental stress such as ultraviolet radiation, electrical stress, mechanical load, etc.. Hence, in this paper, we simulated the factors having influence on aging of polymer insulators using the combined aging test chamber. In order to evaluate an aging characteristics with time, we measured leakage current on these insulators to make out the degree of aging.

  • PDF