• 제목/요약/키워드: Polymer electrolyte membrane Fuel cell

검색결과 467건 처리시간 0.019초

온실 냉난방을 위한 연료전지 기반 열병합 발전 시스템 (Fuel Cell-based Cogeneration System for Greenhouse Cooling and Heating)

  • 박진영;뚜안앵;박승용;이동근;배용균;김영상;이상민
    • 한국수소및신에너지학회논문집
    • /
    • 제34권6호
    • /
    • pp.667-672
    • /
    • 2023
  • This study proposes polymer electrolyte membrane fuel cell (PEMFC) based cogeneration system for greenhouse heating and cooling. The main scope of this study is to examine the proposed cogeneration system's suitability for the 660 m2-class greenhouse. A 25 kW PEMFC system generates electricity for two identical air-cooled heat pumps, each with a nominal heating capacity of 70 kW and a cooling capacity of 65 kW. Heat recovered from the fuel cell supports the heat pump, supplying hot water to the greenhouse. In cooling mode, the adsorption system provides cold water to the greenhouse using recovered heat from the fuel cell. As a result, the cogeneration system satisfies both heating and cooling capability, performing 175 and 145 kW, respectively.

저전류/저가습 조건에서 고분자전해질 막 열화 (Degradation of Polymer Electrolyte Membrane under Low Current/Low Humidity Conditions)

  • 김태희;이정훈;이호;임태원;박권필
    • 한국수소및신에너지학회논문집
    • /
    • 제18권2호
    • /
    • pp.157-163
    • /
    • 2007
  • During PEMFC operation, low current and low humidity conditions accelerate the degradation of perfluorosulfonic acid membrane. But, there have been no studies that clearly explain why these conditions accelerate the membrane degradation. In this study, the hydrogen permeability through the membrane, I-V polarization of MEA, fluoride emission rate(FER) in effluent water were measured during cell operation under low current densities and low relative humidity(RH). The experimental results were evaluated with oxygen radical mechanism the most commonly known for membrane degradation. It seems that low RH of anode is a good condition for $H{\cdot}$ radical formation on the Pt catalyst and the low current condition accelerates the $H{\cdot}$ to form $HO_2{\cdot}$ radical attacking the polymer membrane.

분리판 분할을 통만 연료전지의 전류분포 측정법에 대한 수치적 검증 (Computational Justification of Current Distribution Measurement Technique Via Segmenting Bipolar Plate in Fuel Cells)

  • 최용준;이기용;강경문;김환기;주현철
    • 한국수소및신에너지학회논문집
    • /
    • 제21권1호
    • /
    • pp.1-11
    • /
    • 2010
  • Current distribution measurement technique based on a segmented bipolar plate (BP) has been widely adopted to visualize the distribution of current density in a polymer electrolyte membrane. However, a concern is raised how closely the current density of a segmented BP can approach that of a corresponding non-segmented membrane. Therefore, in this paper, the accuracy of the measurement technique is numerically evaluated by applying a three-dimensional, two-phase fuel cell model to a $100\;cm^2$ area fuel cell geometry in which segmented BPs and non-segmented membrane are combined together. The simulation results reveal that the errors between the current densities of the segmented BPs and non-segmented membrane indeed exist, predicting the maximum relative error of 33% near the U-turn regions of the flow-field. The numerical study further illustrates that the erroneous result originates from the BPs segmented non-symmetrically based on the flow channels that allows some currents bypassing flow channels to flow into its neighboring segment. Finally, this paper suggests the optimal way for bipolar plate segmentation that can minimize the deviation of current measured in a segmented BP from that of a corresponding membrane region.

연료전지 기반 에너지저장 시스템의 환경 전과정평가 및 에너지 효율성 분석 (Life Cycle Assessment (LCA) and Energy Efficiency Analysis of Fuel Cell Based Energy Storage System (ESS))

  • 김형석;홍석진;허탁
    • 한국수소및신에너지학회논문집
    • /
    • 제28권2호
    • /
    • pp.156-165
    • /
    • 2017
  • This study quantitatively assessed the environmental impacts of fuel cell (FC) systems by performing life cycle assessment (LCA) and analyzed their energy efficiencies based on energy return on investment (EROI) and electrical energy stored on investment (ESOI). Molten carbonate fuel cell (MCFC) system and polymer electrolyte membrane fuel cell (PEMFC) system were selected as the fuel cell systems. Five different paths to produce hydrogen ($H_2$) as fuel such as natural gas steam reforming (NGSR), centralized naptha SR (NSR(C)), NSR station (NSR(S)), liquified petroleum gas SR (LPGSR), water electrolysis (WE) were each applied to the FCs. The environmental impacts and the energy efficiencies of the FCs were compared with rechargeable batteries such as $LiFePO_4$ (LFP) and Nickel-metal hydride (Ni-MH). The LCA results show that MCFC_NSR(C) and PEMFC_NSR(C) have the lowest global warming potential (GWP) with 6.23E-02 kg $CO_2$ eq./MJ electricity and 6.84E-02 kg $CO_2$ eq./MJ electricity, respectively. For the impact category of abiotic resource depletion potential (ADP), MCFC_NGSR(S) and PEMFC_NGSR(S) show the lowest impacts of 7.42E-01 g Sb eq./MJ electricity and 7.19E-01 g Sb eq./MJ electricity, respectively. And, the energy efficiencies of the FCs are higher than those of the rechargeable batteries except for the case of hydrogen produced by WE.

가정용 고분자전해질 연료전지 공기공급시스템의 모델 기반 고장 검출 기술 (Model-based Fault Detection Method for the Air Supply System of a Residential PEM Fuel Cell)

  • 원진연;김민진;이원용;최윤영;홍종섭;오환영
    • 한국수소및신에너지학회논문집
    • /
    • 제30권6호
    • /
    • pp.556-566
    • /
    • 2019
  • Recently, as the supply of residential polymer electrolyte membrane fuel cells (PEMFCs) increases, the durability and lifetime of the PEMFC system are becoming important. The related studies have been mainly focused on the durability and lifetime of materials while the research on the durability and maintenance of the system level is insufficient. In this paper, a model-based fault detection method is developed considering an air supply system that is dominant to the system performance and efficiency. A commercial 1 kW residential fuel cell system is built, and experiments are conducted under various operation loads and states (normal, 6 faults). From the experimental data, nominal models and residuals are generated. With the residual pattern obtained from real-time data, the detection and classification of various faults can be possible. The technical importance of this paper is to minimize extra sensor installation by using the empirical model rather than a complex mathematical model, and to decrease the number of models by using the applicable model at three loads. Finally, the model-based fault detection method for the air supply system of a PEMFC is established and is expected to be applicable to other subsystems.

Pd 나노 촉매가 도입된 나피온 막의 기계적 강도 및 고분자 전해질막 연료전지 (PEMFC) 성능 (Mechanical Property of Nafion Membrane Incorporated with Pd Nanocatalyst and the Performance of PEMFC)

  • 이우금;이홍기
    • 한국수소및신에너지학회논문집
    • /
    • 제27권3호
    • /
    • pp.270-275
    • /
    • 2016
  • A simple solid state incorporation method was employed in order to incorporate Pd nanocatalyst into a Nafion film for polymer electrolyte membrane fuel cell (PEMFC) via the reduction of palladium (II) bis (acetylacetonate), $Pd(acac)_2$. It was sublimed, penetrated into Nafion film and then reduced to Pd nanoparticles simultaneously in a glass reactor of N2 atmosphere at $180^{\circ}C$ for 1, 3 and 5 min. This reaction was took place without any reducing agent and any solvent. The morphology of the Pd nanoparticles was observed by transmission electron microscopy (TEM), and Pd distribution was analyzed by scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS). And 23% modification of tensile strength of Pd/Nafion composite film was measured by universal testing machine and I-V curve was estimated by using a unit cell with $5{\times}5cm^2$ active area.

압축기 성능 맵이 자동차용 가압형 고분자전해질형 연료전지 시스템 효율에 미치는 영향 연구 (A Study of the Effect of Compressor Performance Map on the Efficiency of High-pressure Operating PEMFC Systems in Automotive Applications)

  • 조동훈;김한상
    • 한국수소및신에너지학회논문집
    • /
    • 제23권6호
    • /
    • pp.604-611
    • /
    • 2012
  • For the commercialization of fuel cell powered vehicle, it is highly important to improve the performance and efficiency of an automotive polymer electrolyte membrane fuel cell (PEMFC) system. The performance and efficiency of PEMFC systems are significantly influenced by their operating conditions. Among these conditions, the system operating pressure is considered as the one of the main factors. In this study, to investigate the effects of operating pressure on the performance and efficiency of automotive PEMFC systems, two types of high-pressure operating PEMFC systems adopting two different compressors (i. e. different performance maps) are modeled by using MATLAB/Simulink environment. The PEMFC system efficiency and parasitic compressor power are mainly analyzed and compared for the two types of high-pressure operating PEMFC systems under the same system net power conditions. It is expected that this kind of study can contribute to provide basic insight into the operating strategies of high-pressure operating PEMFC systems for automotive use.

비스페닐프로판 단위를 갖는 연료전지전해질용 블록공중합체/나노실리카 복합막 제조 및 특성 (Preparation and Characterization of Block Copolymer Containing Bisphenyl Propane Unit and Nanosilica Composite Membrane for Fuel Cell Electrolyte Application)

  • 김애란
    • 한국수소및신에너지학회논문집
    • /
    • 제28권2호
    • /
    • pp.144-149
    • /
    • 2017
  • A proton-conducting bisphenylpropaned sulfonated fluorinated blockcopolymer (BPSFBC) was synthesized. Five kinds of polymer electrolyted composite membranes were preparated by incorporating silica ($SiO_2$) with various weight ratio. And their characteristics were investigated by FT-IR (fourier transform infrared), $^1H-NMR$ ($^1H$ nuclear magnetic resonance), TGA (thermogravimetric analysis), water uptake, FE-SEM (field emission scanning electron microscopes), and ion conductivity properties. The water uptake and ion conductivity were increased until 9 wt% $SiO_2$, and then decreased. The maximum proton conductivity equal to $52mScm^{-1}$ was measured for the BPSFBC/$SiO_2$-9 composite membrane at $90^{\circ}C$ and 100% relative humidity. From the measured results, it is distinct that the manufactured composite membrane BPSFBC/$SiO_2$-9 can be considered as a polymer membrane suitable for a fuel cell electrolyte.

폴리비닐알콜을 이용한 직접메탄을 연료전지용 이온교환막 제조에 관한 연구 (Studies on the Preparation of the Poly(vinyl alcohol) ion Exchange Membranes for Direct Methanol Fuel cell)

  • 임지원;천세원;전지현;남상용
    • 멤브레인
    • /
    • 제13권3호
    • /
    • pp.191-199
    • /
    • 2003
  • 본 연구는 직접메탄을 연료전지(Direct Methanol Fuel Cell, DMFC)용 전해질 막으로 이용되는 양이온교환막의 개발에 관한 것이다. 투과증발공정에서 메탄을 Barrier로 잘 알려져 있는 Poly(vinyl alcohol)을 Base polymer로 사용하고 양이온 교환기가 포함되어 있는 Poly(acrylic acid)를 가교제로 사용하여 가교제의 함량변화에 따른 메탄을 투과도(Methanol permeability), 이온전도도(Ion conductivity), 이온교환용량(Ion exchange capacity), 함수율(Water content), 고정이온농도(Fixed ion concentration)를 통해 막 특성을 측정하였다. 메탄올 투과도와 이온전도도는 가교제인 PAA함량이 증가함에 따라 감소하다가 15%이상에서는 증가하는 경향을 보였다. 이것은 가교제의 함량증가로 인한 가교의 영향과 가교제에 포함되어 있는 친수성기의 도입으로 이와 같은 결과가 나타난다고 예상된다. 실험결과를 통해 DMFC에 적용가능성이 있는 막은 $25^{\circ}C,\; 50^{\circ}C$에서의 메탄을 투과도가 $6.49{\times}10^{-8}/cm^2/s,\; 2.85{\times}10^{-7}/cm^2/s$, $25^{\circ}C,\; 50^{\circ}C$에서의 이온전도도가 $2.66{\times}10^{-3}\;S/cm,\; 9.16{\times}10^{-3}\;S/cm,$ 이온교환용량이 1.32 meq/g membrane, 함수율이 0.25 g $H_2O$/g membrane, 고정이온농도가 5.25 meq/g $H_2O$인 PVA/PAA-$160^{\circ}C$ 15% 막으로 예측된다.

FEM과 CFD 연동을 통한 스택 체결 시 압력에 의해 변형된 단위 전지 해석 (Analysis of the Deformed Unit Cell by Clamping Force Through the FEM and CFD Interaction)

  • 유빈;임기성;주현철
    • 한국수소및신에너지학회논문집
    • /
    • 제32권4호
    • /
    • pp.228-235
    • /
    • 2021
  • Polymer electrolyte membrane fuel cells (PEMFC) are currently being used in various transport applications such as drones, unmanned aerial vehicles, and automobiles. The power required is different according to the type of use, purpose, and the conditions adjusted using a cell stack. The fuel cell stack is compressed to reduce the size and prevent fuel leakage. The unit cells that make up the cell stack are subjected to compression by clamping force, which makes geometrical changes in the porous media and it impacts on cell performance. In this study, finite elements method (FEM) and computational fluid dynamics (CFD) analysis for the deformed unit cell considering the effects of clamping force is performed. First, structural analysis using the FEM technique over the deformed gas diffusion layer (GDL) considering compression is carried out, and the resulting porosity changed in the GDL is calculated. The PEMFC model is then verified by a three-dimensional, two-phase fuel cell simulation applying the physical properties and geometry obtained before and after compression. The detailed simulation results showed different concentration distributions of fuel between the original and deformed geometry, resulting in the difference in the distribution of current density is represented at compressed GDL region with low oxygen concentration.