지중매설 폴리에틸렌 관의 단기거동 예측 (Prediction of Short-term Behavior of Buried Polyethylene Pipe)

  • 박준석;이영근;김선희;박정환;김응호
    • 상하수도학회지
    • /
    • 제26권6호
    • /
    • pp.907-914
    • /
    • 2012
  • Flexible pipes take advantage of their ability to move, or deflect, under loads without structural damage. Common types of flexible pipes are manufactured from polyethylene (PE), polyvinyl chloride (PVC), steel, glass fiber reinforced thermosetting polymer plastic (GFRP), and aluminum. In this paper, we present the result of an investigation pertaining to the short-term behavior of buried polyethylene pipe. The mechanical properties of the polyethylene pipe produced in the domestic manufacturer are determined and the results are reported in this paper. In addition, vertical ring deflection is measured by the laboratory model test and the finite element analysis (FEA) is also conducted to simulate the short-term behavior of polyethylene pipe buried underground. Based on results from soil-pipe interaction finite element analyses of polyethylene pipe is used to predict the vertical ring deflection and maximum bending strain of polyethylene pipe.

PE 피복형 파형강관의 플랜지 이음부 설계에 관한 연구 (A Study on Flange Coupling Design of Polyethylene Corrugated Steel Pipe)

  • 김태규;이호영;양상민
    • 대한기계학회논문집A
    • /
    • 제31권3호
    • /
    • pp.403-408
    • /
    • 2007
  • The concrete pipe(Hume, PC) and polyethylene(PE) pipe are usually used for dram pipe in local market. Hume pipe, however, is heavy and needs the high cost of construction and PC pipe has a disadvantage to easily occur the deformation by the outside pressure even though it is light and constructible. The corrugated steel pipe coated with polyethylene is used increasedly because it is durable, constructible and economical. However, it is not used for sewage or waste water because it is hard to guarantee the watertight property on the coupling part. In this study, we studied on the flange coupling and the method of its construction to guarantee the watertight property and easy to use. If the developed flange coupling and method are used on a construction field, the economical property, constructible property and structural safety can be guaranteed.

지중매설 폴리에틸렌 관의 장기거동 예측 (Prediction of Long-Term behavior of polyethylene pipe buried underground)

  • 이재호;김빈;윤수현;김응호
    • 상하수도학회지
    • /
    • 제31권1호
    • /
    • pp.7-12
    • /
    • 2017
  • Most of existing buried pipes are composed of reinforced concrete. Reinforced concrete pipes have many problems such as aging, corrosion, leaking, etc. The polyethylene (PE) pipes have advantages to solve these problems. The plastic pipes buried underground are classified into a flexible pipe. National standard that has limited the long-term vertical deformation of the pipe to 5% for flexible pipes including PE pipe. This study presents a prediction for the long-term behavior of the polyethylene pipe based on ASTM D 5365. This prediction method is presented to estimate by using the statistical method from the initial deflection measurement data. We predict the behavior of long-term performance on the double-wall pipe and multi-wall pipe. As a result, it was found that the PE pipe will be sound enough more than 50 years if the compaction of soil around the pipe is more than 95% of the standard soil compaction density.

다양한 결함에 대한 폴리에틸렌 배관의 음향방출 특성 (AE Characteristic of Polyethylene Pipe under various defects)

  • 남기우;이시윤;안석환
    • 한국가스학회지
    • /
    • 제8권3호
    • /
    • pp.1-7
    • /
    • 2004
  • 최근 가스관용으로 압력손실이 큰 동관의 사용은 점차 줄어들고 있는 추세이며, 한편으로는 폴리에틸렌관이 신소재배관재료로서 사용되어 지고 있다. 폴리에틸렌관은 화학적으로 안정성이 높아 부식에 강하고 반영구적으로 사용할 수 있으며, 유연성이 좋아 설치와 유지관리가 편한 장점이 있다. 그러나 외부에 노출되었을 때 쉽게 열화되므로, 주로 저압가스용 매설배관으로서 사용하고 있는 실정이다 그러나 매설배관으로 사용되는 폴리에틸렌관의 사용 중에 발생하는 결함에 대한 비파괴적 평가에 대한 연구는 거의 없다. 본 연구에서는 폴리에틸렌 배관의 건전성을 평가하기 위해 다양한 결함을 상정하여 볼 베어링 충격시험에 따른 음향방출에 의한 신호특성을 평가하였다. 폴리에틸렌 배관의 결함 형상에 따라 파형 및 중심주파수의 구별이 가능하였다. 특히, 노치결함이 있는 경우 노치의 각도와 깊이에 따라 AE신호의 특성이 다르게 나타났다.

  • PDF

Finite element analysis of high-density polyethylene pipe in pipe gallery of nuclear power plants

  • Shi, Jianfeng;Hu, Anqi;Yu, Fa;Cui, Ying;Yang, Ruobing;Zheng, Jinyang
    • Nuclear Engineering and Technology
    • /
    • 제53권3호
    • /
    • pp.1004-1012
    • /
    • 2021
  • High density polyethylene (HDPE) pipe has many advantages over metallic pipe, and has been used in non-safety related application for years in some nuclear power plants (NPPs). Recently, HDPE pipe was introduced into safety related applications. The main difference between safety-related and non-safety-related pipes in NPPs is the design method of extra loadings such as gravity, temperature, and earthquake. In this paper, the mechanical behavior of HDPE pipe under various loads in pipe gallery was studied by finite element analysis (FEA). Stress concentrations were found at the fusion regions on inner surface of mitered elbows of HDPE pipe system. The effects of various factors were analyzed, and the influence of various loads on the damage of HDPE pipe system were evaluated. The results of this paper provide a reference for the design of nuclear safety-related Class 3 HDPE pipe. In addition, as the HDPE pipes analyzed in this paper were suspended in pipe gallery, it can also serve as a supplementary reference for current ASME standard on Class 3 HDPE pipe, which only covers the application for buried pipe application.

탄소섬유를 이용한 Polyethylene배관의 전기융착 기술 (Electrofusion Joining Technology for Polyethylene Pipes Using Carbon Fiber)

  • 안석환;하유성;문창권
    • 한국해양공학회지
    • /
    • 제27권5호
    • /
    • pp.93-98
    • /
    • 2013
  • Fuel gas is an important energy source that is being increasingly used because of the convenience and clean energy provided. Natural gas is supplied to consumers safely through an underground gas-pipe network made of a polyethylene material. In electrofusion, which is one of the joining methods used, copper wire is used as the heating wire. However, it takes a long time for fusion to occur because the electrical resistance of copper is low. In this study, therefore, electrofusion was conducted by replacing the copper heating wire with carbon fiber to reduce the fusion time and improve the production when joining large pipes. Fusion and tensile tests were performed after the electrofusion joint was made in the polyethylene pipe using carbon fiber. The results showed that the fusion time was shorter and the temperature inside the pipe was higher with an increase in the current value. The ultimate tensile strength of specimens was higher than that of virgin polyethylene pipe, except for polyethylene pipes joined using a current of 0.8 A. The best fusion current value was 0.9 or 1.0 A because of the short fusion time and lack of transformation inside the pipe. Thus, it was shown that carbon fiber can be used to replace the copper heating wire.

폴리에틸렌 하수관 연결용 전기발포융착 이음관에 관한 연구 (A Study of Electro-foaming Fusion Wrap for Polyethylene Sewer Pipe)

  • 계형산;주경훈
    • 상하수도학회지
    • /
    • 제26권3호
    • /
    • pp.343-354
    • /
    • 2012
  • A electro-foaming fusion wrap fitting for polyethylene sewer pipe was built and foaming mechanism has been studied. A foaming sheet, supporting sheet and clamping band is assembled into a all-in-one structured electro-foaming fusion wrap fitting. To specify foaming and fusion of electro-foaming fusion wrap for PE sewer pipe, series of fusion tests were performed in various conditions. A parallel plate compression test up to 50 % of inner diameter deflection has been performed to check integrity of fusion quality and it was found that there were no visible signs of crack in wrapped area of fitting. Also air tightness test based on KS M 3511-2 has been performed to evaluate perfectness of wrap fusion quality and we found there were no pressure drop up to 10 times higher value than KS standard regulation.

PE 배관의 인장시험 동안 발생한 AE 특성 (AE characteristic of PE pipe under tensile test)

  • 정정환;남기우;안석환;박인덕
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.130-133
    • /
    • 2002
  • Polyethylene pressure pipe has been used with a gas pipe material because of workability and stability etc.. Researches on characteristics of polyethylene pressure pipe are carried out, but there are rare. In this study, the tensile test was performed on polyethylene pipe. From the tensile test, AE signals were detected and estimated in real time. Also, the time-frequency analysis of AE signals was analyzed. From test results, PE pipes were displayed typical stress-strain curves oj semi-crystalline polymer. As result analyzed AE signals, could divide stress-strain curves could be divided into four stages. In the elastic region, signals were not detected. Low amplitude distributions of 30-35dB appeared after yielding, and high amplitude distributions of 30-60dB appeared with increased extension. From the time-frequency analysis of AE signals, the frequency band of 100kHz appeared mainly. Also, the frequency band of 300kHz appeared before the necking phenomenon spreads into the whole region, and the frequency band of 500kHz appeared on extension earlier.

  • PDF

저압배관용 폴리에틸렌의 인장시험시 발생한 음향방출 특성 (AE Characteristic under Tensile of Polyethylene for Low Pressure Pipe)

  • 이시윤;정정환;안석환;남기우
    • 동력기계공학회지
    • /
    • 제7권1호
    • /
    • pp.82-85
    • /
    • 2003
  • This study is to look at the effect for deformation of Polyethylene, on the wave forms produced by tensile test. Signals collected were then classified visually into three types according to their shapes in the time and frequency domain. Each type should contain signals which could be correlated to a certain micro failure mechanism that occurs during the tensile process. The result showed that the acoustic emission method could be effectively used for analysis of fracture mechanism in Polyethylene structures.

  • PDF

고밀도 폴리에틸렌 파이프의 설치중 구조안정성에 대한 연구 (A Study of Structural Stability of HDPE Pipe during Installation)

  • 송현배;김도균;최한석;박규식
    • 복합신소재구조학회 논문집
    • /
    • 제6권1호
    • /
    • pp.59-66
    • /
    • 2015
  • In this study, structural stability of large diameter high density polyethylene (HDPE) pipe during installation was numerically investigated in order to investigate the effect of concrete collar dimension, water depth and tension (pulling force). From the numerical simulation results, the total stress of HDPE pipe with designed concrete collar was within 2.5%, so the total weight of concrete collar for sinking of HDPE is important rather than concrete collar dimension. Furthermore, the tension area for possible installation is decreased as the air filling rate is increased. Therefore, it is important to calculate the reasonable tension range before actual installation for safe installation of HDPE pipe.