• Title/Summary/Keyword: Polyethylene oxide(PEO)

Search Result 50, Processing Time 0.028 seconds

Heparin Release from Polyurethane-Polyethylene Oxide-Polypropylene Oxide Device (폴리우레탄-폴리에칠렌옥사이드-폴리프로필렌옥사이드-디바이스로부터의 헤파린 방출)

  • Yoo, Jae-Gwon;Jun, Sung-Joo;Kim, Sung-Ho
    • Journal of Pharmaceutical Investigation
    • /
    • v.18 no.4
    • /
    • pp.169-174
    • /
    • 1988
  • The release of heparin from monolithic devices composed of different ratios of polyethylene oxide-polypropylene oxide (PEO-PPO) and hydrophobic polyurethane was investigated. The release rate of heparin could be controlled by varying the PEO-PPO content. The heparin release rate from the devices increased as the content of PEO-PPO in the devices increased. The release mechanism may be associated with creation of micro-channels and pores through the devices following the change in the physical structure of the polymer network. Hydrophobic polyurethane containing PEO-PPO can provide an antithrombogenic material for prolonged release of heparin from a heparin blended system.

  • PDF

Controlled Release of Progesterone from Polyethylene Oxide-Silicone Rubber Matrix

  • Kim, Sung-Ho;O, Sung-l
    • Archives of Pharmacal Research
    • /
    • v.12 no.3
    • /
    • pp.191-195
    • /
    • 1989
  • The release of progesterone from monolithic devices composed of different ratios of polyethylene oxide (PEO; mw 20, 000) and hydrophobic polydimethylsiloxane was investigated. Water soluble PEO soaked into the polymer provided controlled release of progesterone. The release rate of progesterone could be controlled by varying the contents of PEO and progesterone in soaking solution. The progesterone release rate from silicone devices increased as the content of PEO in devices increased, while it decreased as the content of PEO in soaking solution increased. The release rate may be made by simple alterations of geometry of devices controlled swelling and the change in the physical structure of polymer network. Hydrophobic polydimethylsiloxane containing PEO and progesterone can provide a contraceptive material for prolonged release of progesterone.

  • PDF

Preparation and Pharmacokinetic evaluation of Captopril Matrix Tablets with Polyethylene Oxide (폴리에틸렌옥시드를 이용한 캅토프릴 매트릭스 정제의 제조 및 약물동력학적 평가)

  • Jiang, Ge;Baek, Myoung-Ki;Jee, Ung-Kil
    • Journal of Pharmaceutical Investigation
    • /
    • v.29 no.1
    • /
    • pp.7-12
    • /
    • 1999
  • The captopril matrix tablets composed of polyethylene oxide(PEO) was prepared and administered to beagle dogs. Captopril matrix tablets were prepared using direct compressed method and wet granulation compressed method with various ratios of drug to PEO. The diffusion rate of captopril matrix tablets followed on the Higuchi's diffusion model. With increasing hardness of captopril matrix tablets, release rate was decreased. Each formulation was evaluated by the area under the curve (AUC) and time course of plasma captopril concentration after oral administration to beagle dogs. The $AUC_{0-12}$ were $9.126\;{\mu}g\;h/ml$ and $6.417\;{\mu}g\;h/ml$ for the matrix tablets and conventional tablets, respectively. Therefore, the bioavailability of captopril matrix tablets was greater than that of commercial product. It is suggested that captopril matrix tablets using PEO is a useful sustained release formulation.

  • PDF

Swelling and Drug Release Characteristics of Poly (ethylene oxide)-Poly (methacrylic acid) Interpenetrating Networks (폴리에틸렌 옥사이드-폴리메타크릴산 IPN 공중합체의 팽윤 및 약물 방출특성)

  • Lee, Seung-Jin
    • Journal of Pharmaceutical Investigation
    • /
    • v.21 no.3
    • /
    • pp.149-153
    • /
    • 1991
  • Polyethylene oxide (PEO)-polymethacrylic acid (PMAA) interpenetrating polymer networks (IPN) were synthesized via radical polymerization of PMAA and simultaneous crosslinking of PEO using triisocyanate. The equilibrium swelling of PEO-PMAA IPN was determined at different pHs. The swelling of PEO-PMAA IPN, ranged from 20% to 90%, was more sensitive than that of homo polymer PMAA gel This is probably due to protonation and deprotonation of the PMAA network and interpolymer complex formation between PEO and PMAA. Several model drugs were loaded into the IPN matrices and the release mechanisms were investigated. The release of nonionizable drugs such as ftorafur and prednisolone was controlled by swelling of the matrices. However, he release of propranolol, positively charged drug, was more affected by the ionic interaction between the drug and PMAA newtork, and the interpolymer complexation.

  • PDF

Fabrication of Polymer Nanofibers using Electrospinning (전기방사를 이용한 PEO 나노섬유 제조)

  • Kim, G.T.;Ahn, Y.C.;Lee, J.K.;Kattamuri, Nirupama;Sung, C.M.
    • Journal of ILASS-Korea
    • /
    • v.8 no.2
    • /
    • pp.31-37
    • /
    • 2003
  • Polymeric fibers with nanometer-scale diameters are produced by electrospinning method. When the electrical forces at the surface of a polymer solution or melt overcome the surface tension, then electrospinning occurs and nanofibers are made. Polyethylene oxide(PEO) have been electrospun in our laboratory Electrospun PEO fibers are observed by scanning electron microscopy or transmission electron microscopy In thl:; study. the average diameter of the electrospun fibers decreases with decreasing PEO concentration and increasing electric field strength. The optimal conditions for producing uniform PEO 100nm fibers are the 10wt% PEO concentration at a voltage 25 to 30kV and a distance of 10cm from tip to collector.

  • PDF

Pharmaceutical Formulation and Evaluation of Sustained - Release Hydrophilic Matrix Tablet of Cefatrizine Propyleneglycol Using Polyethylene Oxide (폴리에틸렌옥사이드를 이용한 세파트리진프로필렌글리콜 서방성매트릭스 정제의 제조 및 평가)

  • Lee, Eon-Hyoung;Park, Sun-Young;Jee, Ung-Kil;Kim, Dong-Chool
    • Journal of Pharmaceutical Investigation
    • /
    • v.31 no.1
    • /
    • pp.37-41
    • /
    • 2001
  • Various characteristics of polyethylene oxide (PEO) are useful for drug delivery systems. In this study, PEO was used as a sustained release matrix system containing cefatrizine propyleneglycol (Cefa-PG) which is a new semi-synthetic broad-spectrum and orally active cephalosporin. Five kinds of sustained release matrix tablets were formulated with various content of PEO and other ingredients. And three types of matrix tablets were formulated of which compositions were the same but the hardness was different. It was found that PEO content influenced drug release rate. Increasing PEO content, the drug release rate from matrix tablets was decreased. In addition, Avicel, one of the ingredients of matrix components, changed the drug release from the sustained release PEO matrix tablets. With increasing Avicel content, the rate of drug release was increased. For the effect of hardness of matrix tablets, the rate of drug release is decreased with increasing hardness. In comparison of bioavailability parameters after oral administration of Cefa-PG PEO matrix tablets and general Cefa-PG capsule in beagle dog, the sustained release PEO matrix tablets is more useful than a general dosage form. $AUC^{0-12}$ of the sustained release PEO matrix tablet and the general dosage form was 1.16 and 0.644 respectively.

  • PDF

The Steric Repulsion Properties of Polyethylene Oxide

  • Jeon, Sang Il;Joseph D. Andrade
    • Bulletin of the Korean Chemical Society
    • /
    • v.13 no.3
    • /
    • pp.245-248
    • /
    • 1992
  • Polyethylene oxide (PEO) surfaces are recognized as having an effective steric stabilization character. A theoretical scaling analysis involves the osmotic and elastic coefficients of the polymer as a function of molecular weight, in a good solvent. The calculated results show that PEO in water may exhibit the greatest flexibility among water soluble polymers, probably due to its lowest elastic contribution.

Morphology Evolution of Poly(L-lactic acid) (PLLA), Poly(ε-caprolactone) (PCL) and Polyethylene Oxide (PEO) Ternary Blend and Their Effects on Mechanical Properties for Bio Scaffold Applications (폴리락틱산, 폴리카프로락톤, 폴리에틸렌 옥사이드 삼성분계 블렌드의 형태학적 변화와 이들이 의료용 스캐폴더의 기계적 특성에 미치는 영향)

  • Ezzati, Peyman;Ghasemi, Ismaeil;Karrabi, Mohammad;Azizi, Hamed;Fortelny, Ivan
    • Polymer(Korea)
    • /
    • v.38 no.4
    • /
    • pp.449-456
    • /
    • 2014
  • Ternary blends of poly(L-lactic acid) (PLLA), poly(${\varepsilon}$-caprolactone) (PCL) and polyethylene oxide (PEO) were produced with different concentrations of components via melt blending. By leaching the PEO from the samples by water, porous materials were obtained with potential application for bio scaffolds. Sample porosity was evaluated by calculating the ratio of porous scaffold density (${\rho}^*$) to the non-porous material density (${\rho}_s$). Highest porosity (51.42%) was related to the samples containing 50 wt%. of PEO. Scanning electron microscopy (SEM) studies showed the best porosity resulted by decreasing PLLA/PCL ratio at constant concentration of PEO. Crystallization behavior of the ternary blend samples was studied using differential scanning calorimetry (DSC). Results revealed that the crystallinity of PLLA was improved by addition of PEO and PCL to the samples. The porosity plays a key role in governing the compression properties. Mechanical properties are presented by Gibson-Ashby model.

Conductivity properties of ion conducting polymer electrolyte based on poly(ethylene oxide) (이온전도성 poly(ethylene oxide)고분자전해질의 전도특성)

  • 김종욱;문성인;진봉수;구할본;윤문수
    • Electrical & Electronic Materials
    • /
    • v.8 no.4
    • /
    • pp.487-494
    • /
    • 1995
  • The purpose of this study is to research and develop solid polymer electrolyte(SPE) for Li secondary battery. We investigated the effects of lithium salts, plasticizer addition, temperature dependence of conductivity and electrochemical stability window of polyethylene oxide(PEO) electrolytes. PEO electrolyte completed with LiCIO$\_$4/ shows the better conductivity than the others. PEO-LiCIO$\_$4/ electrolyte, when EO/Li$\^$+/ ratio is 8, showed adequate conductivity around room temperature. By adding propylene carbonate and ethylene carbonate to PEO-LiCIO$\_$4/ electrolyte, its conductivity was higher than that of PEO-LiCIO$\_$4/ without those. Also PEO$\_$8/LiCIO$\_$4/ electrolyte remains stable up to 4.5V vs. Li/Li.

  • PDF