• 제목/요약/키워드: Poly vinyl chloride (PVC)

검색결과 117건 처리시간 0.025초

A New Fe (III)-Selective Membrane Electrode Based on Fe (II) Phthalocyanine

  • Ozer, Tugba;Isildak, Ibrahim
    • Journal of Electrochemical Science and Technology
    • /
    • 제10권3호
    • /
    • pp.321-328
    • /
    • 2019
  • A new miniaturized all solid-state contact Fe (III)-selective PVC membrane electrode based on Fe (II) phthalocyanine as a neutral carrier was described. The effects of the membrane composition and foreign ions on the electrode performance was investigated. The best performance was obtained with a membrane containing 32% poly (vinyl chloride), 64% dioctylsebacate, 3% Fe (II) phthalocyanine, and 1% potassium tetrakis (p-chlorophenyl) borate. The electrode showed near Nernstian response of $26.04{\pm}0.95mV/decade$ over the wide linear concentration range $1.0{\times}10^{-6}$ to $1.0{\times}10^{-1}M$, and a very low limit of detection $1.8{\pm}0.5{\times}10^{-7}M$. The potentiometric response of the developed electrode was independent at pH 3.5-5.7. The lifetime of the electrode was approximately 3 months and the response time was very short (< 7 s). It exhibited excellent selectivity towards Fe (III) over various cations. The miniaturized all solid-state contact Fe (III)-selective membrane electrode was successfully applied as an indicator electrode for the potentiometric titration of $1.0{\times}10^{-3}M$ Fe (III) ions with a $1.0{\times}10^{-2}M$ EDTA and the direct determination of Fe (III) ions in real water samples.

Electroanalytical Determination of Copper(II) Ions Using a Polymer Membrane Sensor

  • Oguz Ozbek;Meliha Burcu Gurdere;Caglar Berkel;Omer Isildak
    • Journal of Electrochemical Science and Technology
    • /
    • 제14권1호
    • /
    • pp.66-74
    • /
    • 2023
  • In this study, a new potentiometric sensor selective to copper(II) ions was developed and characterized. The developed sensor has a polymeric membrane and contains 4.0% electroactive material (ionophore), 33.0% poly(vinyl chloride) (PVC), 63.0% bis(2-ethylhexyl)sebacate (BEHS) and 1.0% potassium tetrakis(p-chlorophenyl)borate (KTpClPB). This novel copper(II)-selective sensor exhibits a Nernstian response over a wide concentration range from 1.0×10-6 to 1.0×10-1 mol L-1 with a slope of 29.6 (±1.2) mV decade-1, and a lower detection limit of 8.75×10-7 mol L-1. The sensor, which was produced economically by synthesizing the ionophore in the laboratory, has a good selectivity and repeatability, fast response time and stable potentiometric behaviour. The potential response of the sensor remains unaffected of pH in the range of 5.0-10.0. Based on the analytical applications of the sensor, we showed that it can be used as an indicator electrode in the quantification of Cu2+ ions by potentiometric titration against EDTA, and can also be successfully utilized for the determination of copper(II) ions in different real samples.

중합체(PVC)의 고온 알칼리 용액중에서의 산소 산화에 의한 옥살산과 벤젠 카르복실산으로의 화학적 리사이클링 (Chemical Recycling of Poly(Vinyl Chloride) to Oxalic Acid and Benzene Carboxylic Acids by Oxygen Oxidation in Alkaline Solutions at High Temperatures)

  • Toshiaki-Yoshioka;Shinya-Yasuda;Keiichi-Furukawa;Tsugio-Sato;Akitsugu-Okuwaki
    • 한국자원리싸이클링학회:학술대회논문집
    • /
    • 한국자원리싸이클링학회 1993년도 EARTH 발표논문초록
    • /
    • pp.13.2-13
    • /
    • 1993

Potentiometric Sensor for the Determination of Dibucaine in Pharmaceutical Preparations and Electrochemical Study of the Drug with BSA

  • Ensafi, Ali A.;Allafchian, A.R.
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권8호
    • /
    • pp.2722-2726
    • /
    • 2011
  • Plasticized poly(vinyl chloride), PVCs, with different membrane compositions tested for use in the construction of an ion-selective sensor for the determination dibucaine. A prepared membrane with dioctyl phthalate-PVC and ion-pair of N-(1-naphthyl)ethylenediamine dihydrochloride-tetraphenyl borate had a good potential to acts as a potentiometric sensor for the analysis of dibucaine. A linear relationship was obtained between potential and logC varying between $1.0{\times}10^{-6}$ and $1.0{\times}10^{-2}$ M dibucaine with a good repeatability and reproducibility. The sensor was applied for the determination of the drug in pharmaceuticals and biological fluids such as plasma and urine samples with satisfactory results. The drug electrode has also been used to study the interaction of bovine serum albumin (BSA) with dibucaine. The saturated quantities of dibucaine binding were 13.04, 5.30 and 9.70 mol/mol in 0.01, 0.02 and 0.1% of protein, respectively.

어린이 제품에 함유된 유해 물질 관리 방안에 관한 연구 -학용품을 중심으로- (A Study on the Control of Harmful materials in Children's Goods -centering on school supplies-)

  • 곽순진;김광수
    • 대한안전경영과학회지
    • /
    • 제19권1호
    • /
    • pp.115-122
    • /
    • 2017
  • This study analyzed that the standard of school supplies affects the satisfaction of certification. Safety requirements of school supplies in the Republic of Korea is enforced by court duty certification. Therefore, a test was conducted to compare the safety requirements of the United States and Europe and the survey was conducted to know how much manufacturers and importers are satisfied with the certification. To prepare management measures for harmful substances contained in children's product, XRF(X-ray Fluorescence Spectrometry) is utilized to analyze lead(Pb) and cadmium(Cd) in PA(paint), SP(sheet) and PVC(Poly Vinyl Chloride). The results of comparative analysis of ICP(inductively coupled plasma) is analyzed statistically with measured values.

치장목질마루판 종류별 표면열전달성 분석 (Analysis of Surface Heat Characteristics by Decoration Wood-based Wood Flooring Board)

  • 박철우;임남기
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.171-172
    • /
    • 2017
  • There is some recognition that Decoration Wood-based Flooring Board in Korea is a material that inhibits the heat transfer from the substrate to the room. There is a lack of substantial research literature on the surface heat transfer and condition of Decoration Wood-based Flooring Board, which is insufficient to deal with false perceptions. In this study, the purpose of this study is to analyze the surface heat transfer characteristics of Decoration Wood-based Flooring Board and to obtain basic data to cope with recognition.

  • PDF

Pilymeric Membrane Sodium Ion-Selective Electrodes Based on Calix[4}arene Triesters

  • 김윤덕;정해상;강성옥;남계천;전승원
    • Bulletin of the Korean Chemical Society
    • /
    • 제22권4호
    • /
    • pp.405-408
    • /
    • 2001
  • New lipophilic triesters of calix[4]arene and calix[4]quinone are investigated as sodium ion-selective ionophores in poly(vinyl chloride) membrane electrodes. For an ion selective electrode based on calix[4]arene triester I, the linear response is 1 ${\times}$10-3.5 to 1 ${\times}$ 10-1 M of Na+ concentrations. The selectivity coefficients for sodium ion over alkali metal and ammonium ions are determined. The detection limit (logaNa+ = -4.50) and the selectivity coefficient (logKNa+,K+pot = -1.86) are obtained for polymeric membrane electrode containing calix[4]arene triester I.

Sub-Micro Molar Monitoring of La3+ by a Novel Lanthanum PVC-Based Membrane Sensor Based on 3-Hydroxy-N'-(pyridin-2-ylmethylene)-2-naphthohydrazide

  • Ganjali, Mohammad Reza;Norouzi, Parviz;Yousefian, Nasrin;Faridbod, Farnoush;Adib, Mehdi
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권10호
    • /
    • pp.1581-1586
    • /
    • 2006
  • A La (III) ion-selective membrane sensor has been fabricated from poly vinyl chloride (PVC) matrix membrane, containing 3-hydroxy-N'-(pyridin-2-ylmethylene)-2-naphthohydrazide (HPMN) as a neutral carrier, potassium tetrakis (p-chlorophenyl) borate (KTpClPB) as an anionic excluder and ortho-nitrophenyloctyl ether (NPOE) as a plasticizing solvent mediator. The effects of membrane composition and pH as well as the influence of the anionic additive on the response properties were investigated. The sensor with 30% PVC, 62% solvent mediator, 6% ionophore and 2% anionic additive, shows the best potentiometric response characteristics. It displays a Nernstian behavior (19.2 mV per decade) across the range of $1.0{\times}10^{-2}-1.0{\times}10^{-7}$ M. The detection limit of the electrode is $7.0{\times}10^{-8}$ M ($\sim$10 ng/mL) and the response time is 15 s from $1.0{\times}10^{-2}$ up to $1.0{\times}10^{-4} $M and 30 s in the range of $1.0 {\times}10^{-5}-1.0{\times}10^{-7}$ M. The sensor can be used in the pH values of 3.0-9.0 for about seven weeks. The membrane sensor was used as an indicator electrode in the potentiometric titration of lanthanum ions with EDTA. It was successfully applied to the lanthanum determination in some mouth wash preparations.

한지 소재 내장재의 친환경적 요소 분석 연구 (Study on the Environmental Factor Analysis of Interior Material using Hanji)

  • 김지수;이유라;임현아
    • 한국가구학회지
    • /
    • 제22권1호
    • /
    • pp.63-71
    • /
    • 2011
  • Hanji has known for its high qualities for more than thousand years. Hanji is stronger, and has better durability, air permeability, flexibility, thermal insulation, soundproofs and UV absorbability. Therefore, developing industrial interior finishing materials using Hanji is replaced with the PVC (Poly-Vinyl Chloride) materials instead, it will be a new environment-friendly material and positively represents Korean brand marketing. The industrial inter-construction material is discomposed by heat or light because of material characteristics. As a result, it emits a lot of noxious substances. Hanji is essentially a neutral paper since it does not rely on any acidic chemicals of artificial bleaching methods. Hanji is also known as the living paper because of its close relation to nature. Therefore, I would like to suggest that Hanji made from alternative material as a chicken fiber. It will be a non-polluting interior finishing materials by making use of Hanji to a taste of Korean culture in the green industry around the world. Rather than PVC used commonly in construction material, kitchen and office furniture, interior materials in the subway, trains, or other vessels, credit cards, and ID cards, I created an interior construction material by using patented Hanji. This will be increased the value of usefulness in the environment-friendly green industry instead of PVC.

  • PDF

Simultaneous Determination of Plasticizers in Food Simulants Using GC/MS

  • Park, Na-Young;Yoon, Hae-Jung;Kwak, In-Shin;Jeon, Dae-Hoon;Choi, Hyun-Chul;Eum, Mi-Ok;Kim, Hyung-Il;Sung, Jun-Hyun;Kim, So-Hee;Lee, Young-Ja
    • 한국포장학회지
    • /
    • 제15권3호
    • /
    • pp.93-98
    • /
    • 2009
  • Migration levels of plasticizers, di-n-butyl phthalate (DBP), benzyl-butyl phthalate (BBP), di-n-octyl phthalate(DNOP), di-iso-decyl phthalate (DIDP) and di-iso-nonyl phthalate (DINP), di-(2-ethylhexyl) adipate (DEHA), from 46 poly(vinyl chloride) (PVC) wrap films and 54 PVC gaskets into food simulants were determined using gas chromatography/mass spectrometry (GC/MS). The method was validated with limit of detection (LOD) of $0.01{\sim}0.02\;{\mu}g/mL$ for DBP, BBP, DNOP and DEHA, and $2\;{\mu}g/mL$ for DIDP and DINP. The linearity were found to be > 0.99 for all the compounds in concentration range of $0.1{\sim}81.4\;{\mu}g/mL$, and overall recoveries were ranged from 90.4 ~ 99.6%. DBP, BBP, DNOP, DEHA, DIDP and DINP were not detected in food simulants, except 1 wrap sample from which 0.28 and $0.99\;{\mu}g/mL$ of DEHA were detected respectively when tested with 20% ethanol and n-heptane as food simulants. These values were below the regulatory limitation in European Union (EU).

  • PDF