• Title/Summary/Keyword: Poly(D

Search Result 1,084, Processing Time 0.03 seconds

Self-heating Induced Linear Kink Effect in Poly-Si TFTs

  • Lee, Seok-Woo;Kang, Ho-Chul;Oh, Kum-Mi;Kim, Eu-Gene;Park, Soo-Jeong;Lim, Kyoung-Moon;Kim, Chang-Dong;Chung, In-Jae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1038-1040
    • /
    • 2005
  • Linear kink effect (LKE) induced mainly by selfheating on the reliability of divided channel poly-Si TFTs has been studied. The LKE was enhanced for compact designed structure to achieve narrow bezel, which was explained by the difference in heat dissipation capability, thus self-heating immunity in TFT.

  • PDF

Using Microwave Irradiation to Prepare New Poly(amide-imide)s Containing Tetrahydropyrimidinone, Tetrahydro-2-thioxopyrimidine, and Trimellitic Rings in Their Main Chains: Synthesis and Characterization

  • Faghihi Khalil;Hagibeygi Mohsen
    • Macromolecular Research
    • /
    • v.13 no.1
    • /
    • pp.14-18
    • /
    • 2005
  • Under irradiation in a microwave oven, six novel poly(amide-imide)s containing tetrahydropyrimidinone, tetrahydro-2-thioxopyrimidine moieties and trimellitic rings in their main chains were synthesized through the polycondensation reaction of N,N'-(4,4'-diphenylether)bis(trimellitimide) diacid chloride with six different derivatives of tetrahydropyrimidinone and tetrahydro-2-thioxopyrimidine in the presence of a small amount of a polar organic medium, such as o-cresol. The polycondensation proceeded rapidly and completed within 7-9 min, producing a series of new poly(amide-imide)s in high yield that showed inherent viscosities in the range 0.33-0.52 dL/g. These poly(amide-imide)s were characterized by elemental analysis, viscosity measurement, thermal gravimetric analysis, solubility test, and FT-IR spectroscopy. All of the polymers were soluble at room temperature in polar solvents such as N,N-dimethylacetamide, N,N-dimethylformamide, dimethylsulfoxide, tetrahydrofuran, and N-methyl-2-pyrrolidone.

A study and development of a VR·PC-based adventure game applying low-poly graphics. (Low-Poly 그래픽을 적용한 VR·PC 기반 어드벤처 게임 연구 및 개발)

  • Kwon, Hye-Young;Kim, Soo-Ah;Kim, Ji-Soo;Kim, Hyun-Ji
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2021.11a
    • /
    • pp.1079-1081
    • /
    • 2021
  • Low-Poly는 비교적 적은 수의 Polygon을 가진 3D Computer Graphics의 Polygon Mesh이다. 본 논문의 VR·PC 기반 어드벤처 게임 '하늘섬의 비밀'에 이러한 Low-Poly 그래픽이 적용되어 비현실적이고 감성적인 스토리의 신비로운 분위기를 극대화 하는 효과를 발생시킨다. 또한 Low-Poly 그래픽은 VR 게임에서 현실과 가상세계를 구분하지 못해 생기는 괴리감과 이로 인해 오는 어지러움을 줄이고 사용자의 몰입도를 높여준다.

Transfer Characteristics of Poly-Si TFTs with Laser Energy Change

  • You, Jae-Sung;Kim, Young-Joo;Jung, Yun-Ho;Seo, Hyun-Sik;Kang, Ho-Chul;Lim, Kyong-Moon;Kim, Chang-Dong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.401-404
    • /
    • 2004
  • Transfer characteristics of poly-Si TFTs within process window of laser energy are investigated. In terms of surface morphology and transfer characteristics, process window of laser crystallization is evaluated. While maximum mobility exists in lower edge of process window in n-channel TFTs, maximum mobility exists in higher edge of process window in p-channel TFTs.

  • PDF

Methods for Coating the Killed Whole Cell Antigens of Salmonella typhi in Enzyme-linked Immunosorbent Assay (효소면역측정법을 위한 장티푸스 균체항원의 부착방법)

  • Kim, Youn-Won;Hwang, Eung-Soo;Kook, Yoon-Hoh;Choi, Kang-Won;Kim, Ik-Sang;Cha, Chang-Yong;Lee, Seung-Hoon
    • The Journal of the Korean Society for Microbiology
    • /
    • v.20 no.1
    • /
    • pp.91-102
    • /
    • 1985
  • The advantages of enzyme-linked immunosorbent assay(ELISA) are its senstivity and simplicity in detecting IgG, IgM and IgA antibody. To apply ELISA to diagnosis of typhoid fever, antigen such as lipopolysaccharide of Salmonella typhi or killed whole cell must be coated on solid phase. It is easy to coat lipopolysaccharide on ELISA plate but troublesome to purify it. As it is easy to obtain the killed whole cells, the development of the appropriate method by which those antigens of S. typhi are optimally coated on solid phase is needed. To establish the appropriate method, carbonate buffer, methanol or poly-L-lysine was applied as binding substance on polystyrene or polyvinylchloride plate as solid phase when the killed whole cell antigens of S. typhi varided as follows: $10^6$, $10^7$, $10^8$ and $10^9\;cell/ml$. The criteria of the optimal method were determined as follows: 1. The optical density of positive sera is above 1.0(0.6 in IgM) at 1:10 serum dilution and is 0.3(0.2 in IgM) higher than that of negative sera: 2. The O.D. of sera is flat or lowering according to serum dilution: 3. It must be that the O.D. of negative sera is lower than 0.2 at the point of serum dilution where the O.D. of positive sera is higher than 1.0(0.5 in IgM). The results obtained were summarized as follows: 1. The methods which fitted the above criteria were to use poly-L-lysine as binding substance, polyvinylchloride plate as solid phase and $10^7\;cell/ml$ as antigen concentration of S. typhi(poly-L-lysine/polyvinylchloride/$10^7$) and poly-L-lysine/polyvinylchloride/$10^8$ in detecting IgG antibody, methanol/polystyrene/$10^9$, poly-L-lysine/polyvinylchloride/$10^8$ and poly-L-lysine/polyvinylchloride/$10^9$ in IgM and carbonate buffer/polystyrene/$10^8$, carbonate buffer/polystyrene/$10^9$, methanol/polystyrene/$10^8$, methanol/polyvinylchloride/$10^8$, methanol/polyvinylchloride/$10^9$, poly-L-lysine/polyvinylchloride/$10^8$ and poly-L-lysine/polyvinylchloride/$10^9$ in IgA. 2. The coaling method using poly-L-lysine, polyvinylchloride plate and $10^8\;cell/ml$ was best to assay IgG, IgM and IgA antibody all in one. By this method, to assay the each immunoglobulin calss with an appropriate fixed serum dilution, 1:320 dilution was best.

  • PDF

Preparation and Evaluation of Poly(methylmethacrylate-co-trimethoxysilylpropylmethacrylate) Spheres Containing Whitening and Anti-wrinkle Agents (미백 및 주름개선 성분을 함유하는 Poly(methylmethacrylate-co-trimethoxysilylpropylmethacrylate) 구의 제조와 평가)

  • Jung, Taek-Kyu;Lim, Mi-Sun;Kim, Young-Back;Yoon, Kyung-Sup
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.32 no.1 s.55
    • /
    • pp.35-44
    • /
    • 2006
  • Recently, encapsulation studies have been tarried out to protect active agents using shell materials such as polymers, lipids, inorganic materials and the other protective materials. We have prepared copolymers of methylmethacrylate (MMA) and trimethoxysilylpropylmethacrylate (TMPMA), and the copolymers as shell materials were used for encapsulating active agents. Poly(MMA-co-TMPMA) spheres were very efficient for encapsulating active agents such as vitamin derivatives (such as retinol, retinyl palmitate, tocopheryl acetate and ascorbyl tetraisopalmitate) and oil soluble licorice extract etc. Mean diameters of poly(MMA-co-TMPMA) core-shell spheres containing active agents varied between about 0.1 to $10{\mu}m$ according to the experimental conditions. The loading amount of encapsulating active agents was 15 to 25% (w/w) and the loading yield was above 90%. The stability of active agents in poly(MMA-co-TMPMA) core-shell spheres prepared with an UV absorbing precursor increased by 25% compared with that of active agents in spheres prepared without an UV absorbing precursor.

Effect of Biodegradable Polymer Coating on the Corrosion Rates and Mechanical Properties of Biliary Magnesium Alloy Stents (생분해성 고분자 코팅이 담관용 마그네슘 합금 스텐트의 분해 속도와 기계적 물성에 미치는 영향)

  • Kim, Hyun Wook;Lee, Woo-Yiel;Song, Ki Chang
    • Korean Chemical Engineering Research
    • /
    • v.58 no.1
    • /
    • pp.36-43
    • /
    • 2020
  • A biliant stent was fabricated using a magnesium alloy wire, a biodegradable metal. In order to control the fast decomposition and corrosion of magnesium alloys in vivo, magnesium alloy wires were coated with biodegradable polymers such as polycaprolactone (PCL), poly(propylene carbonate) (PPC), poly (L-lactic acid) (PLLA), and poly (D, L-lactide-co-glycolide) (PLGA). In the case of PPC, which is a surface erosion polymer, there is no crack or peeling compared to other polymers (PCL, PLLA, and PLGA) that exhibit bulk erosion behavior. Also, the effect of biodegradable polymer coating on the axial force, which is the mechanical property of magnesium alloy stents, was investigated. Stents coated with most biodegradable polymers (PCL, PLLA, PLGA) increased axial forces compared to the uncoated stent, reducing the flexibility of the stent. However, the stent coated with PPC showed the axial force similar to uncoated stent, which did not reduce the flexibility. From the above results, PPC is considered to be the most efficient biodegradable polymer.

Mechanical properties and 3D CAD Images of the Appearance of Cotton/Polyester Composite Yarn Knitted Fabric by Different Yarn Twisting Methods (연사방법에 따른 면/폴리에스테르 복합사 편성물의 역학적 특성 및 3D CAD System에 의한 외관특성)

  • Kim So-Jin;Jeon Dong-Won;Park Young-Hwan
    • Textile Coloration and Finishing
    • /
    • v.18 no.3 s.88
    • /
    • pp.49-58
    • /
    • 2006
  • The purpose of this study was to examine the effect of covering yarn's twist on mechanical properties of knitted fabrics of composite yarns with single covering process. Four yarns that were used in this study: two different composite yarns made from the four kinds of cotton and functional polyester-(Poly-A) with the ratio of 52:48, and the rest two yarns are the original cotton 100% yarn and the poly-A 100% yarn. The two kinds of composite yarns, CP1 and CP2, were processed on the single covering process. CP1 was applied on the single covering process with S-800 tpm, where Poly-A was used as covering yarn and cotton was used as core yarn. CP2 was applied on the same process as CP1 except that Poly-A had been applied on the two-for-one twisting process with S-400 tpm on the previous step. Sixteen mechanical properties of all the four knifed fabrics knitted under the same knitting conditions were measured by KES-FB system with the outer knit condition. And 3D CAD dressmaking simulations, which were driven by some of the mechanical properties, were presented. The results were as follows: CP2 had high RT values with twisting of covering yarn. CP2 also had high B, 2HB values because of higher linear density. SMD was affected rather by twisting of covering yarn than by fine hair of the cotton surface. Twisting of covering yarn made it decreasing T value and increasing W value. Dressmaking 3D CAD simulations showed that there are buckling effects on CP2 because of high bending rigidity and shear rigidity.

Stabilization of Enzyme in "Solvophobically" Controlled Polymer Microcapsules ("솔보포빅"한 고분자 마이크로 캡슐을 이용한 효소 안정화에 관한 연구)

  • Kim, Yong-Jin;Kim, Jin-Woong;Kim, Jin-Oh;Kim, Jin-Woo;Chang, Ih-Seop
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.32 no.1 s.55
    • /
    • pp.29-33
    • /
    • 2006
  • This article describes an enzyme stabilization method that allows the use of enzymes irrespective of environmental factors, especially heat, while maintaining their activity for a long time. We have designed enzyme microcapsules that consist of papain enzyme cores, poly(propylene glycol) interlayers, and poly(${\epsilon}-caprolactone$) walls. By confocal laser scanning microscopy measurements and the thermal stability of papain-loaded microcapsules, it is demonstrated that the papain is surrounded by a hydrophobic polyol layer and stabilized by the exclusive volume effect. In our study, improved thermal stability can be obtained by using more hydrophobic long-chained polyols, which is understood to be attributed to the effective formation of a hydrophobic polyol layer between the papain and the polymer wall by means of conformational anchoring in the interface.

Accuracy of three-dimensional printing for manufacturing replica teeth

  • Lee, Keun-Young;Cho, Jin-Woo;Chang, Na-Young;Chae, Jong-Moon;Kang, Kyung-Hwa;Kim, Sang-Cheol;Cho, Jin-Hyoung
    • The korean journal of orthodontics
    • /
    • v.45 no.5
    • /
    • pp.217-225
    • /
    • 2015
  • Objective: Three-dimensional (3D) printing is a recent technological development that may play a significant role in orthodontic diagnosis and treatment. It can be used to fabricate skull models or study models, as well as to make replica teeth in autotransplantation or tooth impaction cases. The aim of this study was to evaluate the accuracy of fabrication of replica teeth made by two types of 3D printing technologies. Methods: Fifty extracted molar teeth were selected as samples. They were scanned to generate high-resolution 3D surface model stereolithography files. These files were converted into physical models using two types of 3D printing technologies: Fused deposition modeling (FDM) and PolyJet technology. All replica teeth were scanned and 3D images generated. Computer software compared the replica teeth to the original teeth with linear measurements, volumetric measurements, and mean deviation measurements with best-fit alignment. Paired t-tests were used to statistically analyze the measurements. Results: Most measurements of teeth formed using FDM tended to be slightly smaller, while those of the PolyJet replicas tended to be slightly larger, than those of the extracted teeth. Mean deviation measurements with best-fit alignment of FDM and PolyJet group were 0.047 mm and 0.038 mm, respectively. Although there were statistically significant differences, they were regarded as clinically insignificant. Conclusions: This study confirms that FDM and PolyJet technologies are accurate enough to be usable in orthodontic diagnosis and treatment.