• Title/Summary/Keyword: Polishing time

Search Result 299, Processing Time 0.029 seconds

Reel-to-reel electropolishing of Ni alloy tapes for IBAD template (IBAD template용 니켈 합금의 연속 전해연마)

  • Ha H. S;Kim H. K;Ko R. K;Kim H. S;Song K. J;Park C;Yoo S. I;Joo J. H;Moon S. H
    • Progress in Superconductivity
    • /
    • v.6 no.1
    • /
    • pp.69-73
    • /
    • 2004
  • Ni alloy tape is electropolished to be used as a metal substrate for fabrication of IBAD (ion-Beam Assisted Deposition)-MgO texture template fur HTS coated conductor. Electropolishing is needed to obtain a very smooth surface of Ni alloy tape because the in-plane texture of templates is sensitive to the roughness of metal substrate. The critical current of YBCO coated conductor depends on the texture of YBCO that depends on the texture of the IBAD MgO layer. And so the smoothness of the metal substrate is directly related to the superconducting properties of the coated conductor. In this study, we have prepared a reel-to-reel electropolishing apparatus to polish the Ni alloy tapes for IBAD. Various electropolishing conditions were investigated to improve the surface roughness. Hastelloy tape is continuously electropolished with high polishing current density (0.5 ∼ 2 A/$\textrm{cm}^2$) and fast processing time (1 ∼ 3 min). Polished hastelloy tapes have surface roughness(RMS) of below 1 nm on a 5 ${\times}$ 5 $\mu\m^2$ from AFM and SEM.

  • PDF

Performance Evaluation of Tertiary Post-denitrification Processes for the Reuse of Secondary Effluent from Wastewater Treatment Plant (하수2차처리수의 재이용을 위한 후탈질공정의 평가)

  • Lee, Chanho;Yun, Zuwhan;Yi, Yun Seok;Lee, Han Saem;Ahn, Dong Keun
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.5
    • /
    • pp.642-649
    • /
    • 2007
  • The effectiveness of add-on tertiary treatment processes for the polishing of the effluent of a biological nutrient removal (BNR) system from a modified $A^2/O$ process has been examined under the field condition with pilot-scale plants. The add-on treatment processes of 1) combined biofilm anoxic reactor and sand filtration, and 2) two-stage denitrification filter had been operated with various operating conditions. The experimental results indicated that two-stage denitrification filter could produced a better polished tertiary effluent. Filtration rate of $150m^3/m^2{\cdot}d$ for the 2-stage denitrifying filter could decrease the nitrate removal probably due to shorter detention time that caused insufficient reaction for denitrification. Two stage denitrification filter operated with M/N ratio of 3.0 and filtration rate of $100m^3/m^2{\cdot}d$ produced the tertiary effluent with nitrate and SS concentraitons of 2.8 mg/L and 2.3 mg/L, respectively. When the operating temperature reduced $30^{\circ}C$ to $18^{\circ}C$, $NO_3{^-}-N$ removal efficiency decreased from 73% to 68%.

Study of Inhibition Characteristics of Slurry Additives in Copper CMP using Force Spectroscopy

  • Lee, Hyo-Sang;Philipossian Ara;Babu Suryadevara V.;Patri Udaya B.;Hong, Young-Ki;Economikos Laertis;Goldstein Michael
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.1
    • /
    • pp.5-10
    • /
    • 2007
  • Using a reference slurry, ammonium dodecyl sulfate (ADS), an anionic and environmentally friendly surfactant, was investigated as an alternative to BTA for its inhibition and lubrication characteristics. Results demonstrated that the inhibition efficiency of ADS was superior to that of BTA. Coefficient of friction (COF) was the lowest when the slurry contained ADS. This suggested that adsorbed ADS on the surface provided lubricating action thereby reducing the wear between the contacting surfaces. Temperature results were consistent with the COF and removal rate data. ADS showed the lowest temperature rise again confirming the softening effect of the adsorbed surfactant layer and less energy dissipation due to friction. Spectral analysis of shear force showed that increasing the pad-wafer sliding velocity at constant wafer pressure shifted the high frequency spectral peaks to lower frequencies while increasing the variance of the frictional force. Addition of ADS reduced the fluctuating component of the shear force and the extent of the pre-existing stick-slip phenomena caused by the kinematics of the process and collision event between pad asperities with the wafer. By contrast, in the case of BTA, there were no such observed benefits but instead undesirable effects were seen at some polishing conditions. This work underscored the importance of real-time force spectroscopy in elucidating the adsorption, lubrication and inhibition of additives in slurries in CMP.

Differences in view of dental hygienist and patient's scaling actual condition and disputes (치과위생사와 환자의 치석제거 실태와 분쟁에 대한 견해 차이)

  • Seong, Mi-Gyung;Kang, Hyun-Kyung;Kim, Yu-Rin
    • Journal of Korean society of Dental Hygiene
    • /
    • v.20 no.5
    • /
    • pp.623-633
    • /
    • 2020
  • Objectives: Since scaling has been covered by insurance, the number of patients undergoing scaling has increased. Simultaneously, legal disputes around scaling have increased. Therefore, this study was aimed at comparing the differences between the perceptions of dental hygienists and patients regarding the scaling procedure and providing dental hygienists with basic data to find ways to reduce disputes arising from these differences. Methods: A survey was conducted on 119 dental hygienists working in Busan and the South Gyeongsang Province and 110 patients who visited hospitals for scaling. Frequency analyses were performed for dental hygienists' scaling behavior and patient discomfort during scaling. The independent t-test and chi-square test were performed to compare the perceptions of dental hygienists and patients regarding the scaling procedure. Results: Polishing after scaling was performed according to 70.1% of dental hygienists but only 29.9% of patients. Oral health education was provided according to 20.4% of dental hygienists, while 79.6% of patients said that they received oral health education at the Dentiform. The scaling time was reported to be shorter by patients than by dental hygienists. Both dental hygienists and patients said that legal action was required if problems occurred during scaling, and the refund standard was that patients needed it more than dental hygienists. Conclusions: There are differences between the perceptions of dental hygienists and patients regarding scaling. Dental hygienists should identify these differences and try to prevent conflicts or disputes with patients around scaling.

A Study on Predicting Ship Resistance Performance due to Surface Roughness Using CFD (CFD를 이용한 표면 거칠기에 따른 선박의 저항 성능 추정에 관한 연구)

  • Seok, Jun;Park, Jong-Chun;Shin, Myung-Soo;Kim, Sung-Yong
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.53 no.5
    • /
    • pp.400-409
    • /
    • 2016
  • In recent, shipping companies have made an enormous effort to improve the operation of vessel in various approaches, due to recession of shipping market and increasing competition among shipping companies. One of important parameters for improving the efficiency of vessel is the resistance performance that consist of friction and residual resistance. Especially, it is recognized that the friction resistance tends to be affected by conditions of vessel’s surface and occupies approximately 70~90% of the total resistance for slow speed ships. In general, the surface of vessel is covered with various type of paint to reduce fouling and corrosion. As time goes by, however, it is so hull roughness would be increased by fouling over the wetted surface that anti-fouling paints, such as CDP(Controlled Depletion Paint), Tin-Free SPC(Self Polishing Co-polymer) or Foul Release, are applied evenly on the hull surface. Nevertheless, these anti-fouling paints could not prevent fouling absolutely. A fundamental study on evaluating ship resistance performance variation due to hull roughness has been performed using a commercial software, Star-CCM+, which solves the continuity and Navier-Stokes equations for incompressible and viscous flow. The results of present simulation for plate are compared with some experimental data available and the effect of surface roughness to ship resistance performance is discussed.

A STUDY ON MARGINAL ADAPTATION OF READY-MADE STAINLESS STEEL CROWN TO THE PRIMARY MOLAR (기성금관수복 유구치의 변연 적합도에 관한 연구)

  • Lee, Sun-Kyung;Lee, Gwang-Su;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.23 no.2
    • /
    • pp.389-400
    • /
    • 1996
  • In Class II amalgam restoration in deciduous molar, failure rate and incidence of recurrent caries are high as children become older. In order to preserve deciduous molars till the physiologic exfoliation time, stainless steel crown is a choice of the treatment. As a result of a careless treatment, such as overhanging margin, poor marginal adaptation, poor proximal contour and inadequate mesiodistal width give rise to interfering eruption of the adjacent teeth, recurrent caries and chronic gingival irritation and insufficient arch length respectively. In this study, 252 s.s. crowned teeth extracted due to physiologic exfoliation or periapical lesion. The purpose of this study is to analyze the marginal adaptation of stainless steel crown to the deciduous molar in order to obtain better clinical result. The results were as follows : 1. Between the length of s.s. crown and the marginal gap of crown, positive correlations were shown. 2. Largest amount of marginal gap was shown at buccal side in upper deciduous molars and lower first deciduous molar, lingual side in lower second deciduous molar. But no significant diffrence were found statistically compared to second most largest one. 3. Incidence of exposed restoration and recurrent caries were higher in proximal surface than buccal/lingual surface. And extension of restoration below the margin of s.s. crown gives rise to higher rate of recurrent caries. 4. Defect of contour was found in 34%, frequently found in lower 1st deciduous molar and upper 1st deciduous molar. 5. Marginal polishing defects were found in 23%. 6. Ledge was formed in 10% especially in lower 1st deciduous molar and lower 2nd deciduous molar. 7. 16% of the teeth had wear facet due to traumatic occlusion, 7% of them had occlusal perforation.

  • PDF

Effect of Waste Marble Powder on the Fundamental Properties of High Fluidity Concrete (폐 대리석 분말을 혼입한 고유동 콘크리트의 기초적 특성에 대한 실험적 연구)

  • Lee, Yong-Moo;Shin, Sang-Yeop;Kim, Young-Su
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.2
    • /
    • pp.153-160
    • /
    • 2015
  • The marble powder is a by-product that can be freely collected during the manufacturing process of marble, such as sawing, shaping, and polishing. Disposal of this waste powder is one of the environmental problems worldwide today. Therefore, this study investigated to solve this problem by consuming the waste marble powder in high fluidity concrete, as a pore filler. For this purpose, the waste marble powder was used as a binder replacing 5%, 10%, 15%, and 20% of cement in high fluidity concrete. After mixing, slump flow test, time-to-reach the slump flow of 500mm test, O-lot test and U-box test were conducted with fresh concrete. For the hardened concrete, compressive strength was determined at the age of 28 days. According to the test results, the workability of high fluidity concrete increased with the powder of 15% replacement, and the compressive strength of high fluidity concrete also increased with the same amount of powder.

Ceramic materials for chair side CAD/CAM (체어사이드 CAD/CAM에서 사용하는 세라믹 소재)

  • Kim, Heechul
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.23 no.1
    • /
    • pp.16-26
    • /
    • 2014
  • Materials that can be use in CAD/CAM are composite, ceramic, hybrid and metal. Among the available materials, monolithic ceramic technique which is the manufacturing technique using one type of the materials is mainly used in a dental office. It is the technique where final tooth-shaped prostheses are made from the material block and used after polishing or applying heat and that does not require traditional ceramic build-up process. Although shot of esthetic quality, because manufactured within 1 hour the monolithic ceramic technique has advantages such as that treatment can be completed in one day and in one time visit, that stability of the material is high because there are low possibility of distort by not melting and phase transformation, and that it can be easily worked in the office with computer assisted devices. We classified the materials that can be used in this technique based on their generations from clinical stand point.

Localization Technology Development of 16oz Popper Kettle through Existing Kettle Analysis and Heating System Study (기존 케틀 분석 및 가열 시스템 연구를 통한 16oz 팝퍼 케틀 국산화 기술 개발)

  • Lee, Jung-Hun;Kim, Kyoung-Chul;Oh, Young-Sub;Ryuh, Beom-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7773-7780
    • /
    • 2015
  • Analysis of existing kettle and its heating system has been the topic for localization technology development. Test pieces are made, polished and etched for existing kettle analysis. Surface of test pieces is observed using SEM, the kettle is verified to be made by deep drawing process from Ferrite-Perlite material. The kettle is also identified to be plated $16{\sim}49{\mu}m$ of thickness with Nickel(16%). Also heat transfer characteristics based on hot wire arrangement is investigated and optimal hot wire system is developed. Developed control system detects overheating and stops the whole system on the long operating time. Developed kettle takes the performance evaluation test for volume expansion and satisfied for standard 'KS G3602'.

Utilizing Advanced Pad Conditioning and Pad Motion in WCMP

  • Kim, Sang-Yong;Chung, Hun-Sang;Park, Min-Woo;Kim, Chang-Il;Chang, Eui-Goo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.171-175
    • /
    • 2001
  • Chemical mechanical polishing(CMP) process has been widely used to planarize dielectrics and metal, which can apply to employed in integrated circuits for sub-micron technology. Despite the increased use of CMP process, it is difficult to accomplish the global planarization of free-defects in inter level dielectrics and metal. Especially, defects like (micro-scratch) lead to severe circuit failure, and affects yield. Current conditioning method - bladder type, orbital pad motion - usually provides unsuitable pad profile during ex-situ conditioning near the end of pad life. Since much of the pad wear occurs by the mechanism of bladder tripe conditioning and its orbital motion without rotation, we need to implement new ex-situ conditioner which can prevent abnormal regional force on pad caused by bladder-type and also need to rotate the pad during conditioning. Another important study of ADPC is related to the orbital scratch of which source is assumed as diamond grit dropped from the strip during ex-situ conditioning. Scratch from diamond grit damaged wafer severely so usual1y scraped. Figure 1 shows the typical shape of scratch damaged from diamond. We suspected that intensive forces to the edge area of bladder type stripper accelerated the drop of Diamond grit during conditioning, so new designed Flat stripper was introduced.

  • PDF