• Title/Summary/Keyword: Pole

Search Result 2,684, Processing Time 0.028 seconds

Pole-pole array electrical resistivity survey and an effective interpretational scheme of its data (2극법 전기비저항 탐사 자료의 효율적인 해석방법)

  • Cho Dong-Heng;Lee Chang Yourl;Jee Sang-Keun
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2000.09a
    • /
    • pp.112-131
    • /
    • 2000
  • In spite of its many strong points, pole-pole electrode configuration is not often used for ground electrical resistivity survey except for bore hole survey as normal logging and for archaeological investigation. Above all, poor spatial resolution of pole-pole survey may be responsible for this. But recent experiences so far gained by the present authers lead them to think that pole-pole survey can be at least a viable means of reconnaissance survey in near-surface conductive environment and an effective interpretational scheme may augment its resolution. As well known, a response of any other electrode configuration is a linear combination of pole-pole responses. Based on this principle of linear superposition and the principle of reciprocity, the other 'responses' can be derived with simple additions and subtractions of pole-pole responses. Though such responses are not always correct due to the adverse effects of noises, combined with the potential decay curves, they can be helpful to interprete better pole-pole survey data especially in connection of the resolution. This can be comparable to the use of the first or second derivatives of gravity and magnetic intensity surveys.

  • PDF

Research of Stresses Distribution and Loading Weight on Concrete Electric Pole Considering Field Condition (설치조건을 고려한 배전용 콘크리트전주의 응력분포 및 하중에 관한 연구)

  • Kim, Dong-Myung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.183-188
    • /
    • 2004
  • A method of double-pole construction is developing to strengthen the mechanical intensity of the electric poles. Therefore the mechanical properties of the double-pole were researched in this paper. First, considering field special quality electric poles were established. In the next tensile force was applied and stress distribution and fatigue load were examined. When a base of the pole is concrete, mechanical intensity of the double-pole increased about 1.7 times compared a single pole. In the case of general soil base, the concrete base should be needed to expect the reinforcement effect of the double-pole.

Reliability Upgrading Technologies of Distribution Transformers (주상 변압기 신뢰성 향상기술)

  • Song, I.K.;Lee, B.S.;Jung, J.W.;Kim, D.M.;Kim, J.Y.;Lee, J.B.;Kwon, T.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.212-215
    • /
    • 2003
  • In this paper, a model pole transformer was designed to improve the reliability of pole transformers and its short circuit withstand strength was tested. The failure causes of the pole transformers which had been operated in the field were analyzed and several patterns of the causes were determined. A novel countermeasure was devised to prevent the failures of the pole transformers in advance. A model pole transformer was designed and made in accordance with the given specifications to strengthen the short circuit withstand capability and its characteristic was tested. As a result, the advanced performance of the model pole transformer was confirmed and novel techniques in manufacturing process was suggested. It is considered that all the methods employed in the developing process will be helpful to design and manufacture the pole transformers thus the reliability of pole transformers in distribution lines will be improved.

  • PDF

Experience and Analysis of Pole Interaction for Jeju HVDC No. 2: Practical Solution for Non-Interruptible Power Transfer (제주 HVDC No. 2의 극간 상호작용 경험과 분석: 무정전 전력 송전을 위한 실용적 해결방안)

  • Kim, Hee-Jin;Kim, Chan-Ki;Park, Chang-Hwan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.6
    • /
    • pp.459-468
    • /
    • 2020
  • The pole interaction of the line-commutated converter high-voltage direct current (HVDC) is analyzed, and a practical solution that uses a surge arrester is proposed. Jeju HVDC No. 2 is a double-monopole HVDC link that has a rated power capacity of 2 × 200 MW and was commissioned in 2012. During normal operation, Jeju HVDC No. 2 is operated in the bipolar mode to minimize the loss caused by the dedicated metallic return. However, when one pole of the inverter valve is bypassed, a commutation failure can occur in the other pole. This phenomenon is called pole interaction in this work. This pole interaction interrupts the HVDC power transfer for almost 2 s and may affect the stability of the power system. This research proposes the installation of a surge arrester at the inverter neutral, which can be an effective and practical solution for pole interaction. The HVDC system is analyzed, and the residual voltage of the surge arrester is determined. Detailed simulation using PSCAD/EMTDC demonstrates that the proposed method eliminates the pole interaction of the bipolar-operated HVDC.

The Study on the design of Claw Pole Stepping Motor considering Axial flux (축 방향 자속을 고려한 Claw pole 스테핑 모터 설계에 관한 연구)

  • Jung, Dae-Sung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.9
    • /
    • pp.28-34
    • /
    • 2014
  • A claw pole stepping motor is widely used in various fields such as a compact optical disk drive, computer peripherals, digital cameras, office automation(OA), handheld mobile devices, because it has the suitable structure for compact motor. However 3D analysis is essential for design of Claw pole stepping motor because of axial flux path. Thus, in general, it takes a lot of time in the design of Claw pole motor. In this paper, magnetic equivalent circuit considering axial flux was proposed to reduce design time of Claw pole motor and we has designed by using the magnetic equivalent circuit. In addition, in oder to verify the study, design model was verified by 3D FEM simulation and experiment.

Initial Pole Position Estimation of Surface PM-LSM

  • Kim, Tae-Woong;Junichi Watanabe;Sumitoshi Sonoda;Junji Hirai
    • Journal of Power Electronics
    • /
    • v.1 no.1
    • /
    • pp.1-8
    • /
    • 2001
  • The elimination of a pole sensor is desirable due to the low-cost requirement, the compactness, and the applied drives. This paper proposes the algorithm for the initial pole-position estimation of a surface permanent magnet linear synchronous motor (PM-LSM), which is carried out under the closed loop control without a pole sensor and is insensitive to the motor parameters. This algorithm is based on the principle that the initial pole position (IPP) is estimated by the trigonometric function of the two reference currents. The effectiveness of the proposed algorithm is confirmed by testing a surface PM-LSM with large disturbance, which result shows that IPP is well estimated within a satisfied moving-distance and a shorter estimation taken-time even if large disturbance such as cogging and friction is existed.

  • PDF

Application to a Multimachine Power System of Power System Stabilizer using Revised Pole Shift Adaptive Control Algorithm (개선된 극점이동 적응제어 알고리즘을 이용한 전력계통 안정화장치의 다기계통 적용)

  • Lee, Sang-Keun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.10
    • /
    • pp.486-493
    • /
    • 2000
  • This paper presents an application to a multimachine power system of power system stabilizer using revised pole shift adaptive algorithm. Controller parameters are determined by using adaptive control theory in order to maintain optimal operation of generator under the various operating conditions. To determine the optimal parameters of controller and overcome the problem of pole placement algorithm, this paper presents pole shift algorithm revised pole shift factor. Also, the difference between the speed deviation with weighted factor and voltage deviation is used as the input signal of adaptive controller, which provides good damping characteristics. The results tested on a multimachine power system verify that the proposed controller has better dynamic and transient performance than conventional controller.

  • PDF

Stress Analysis Acting on Electric Pole using Strain Gauge from Full Scale Pull-Out Test (실물인장실험시 변형률계를 이용한 전주에 작용하는 응력분석)

  • Ahn, Tae-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.49-55
    • /
    • 2010
  • Many electric poles in the softground have been collapsed due to external load. In this study, 10 types of tests were performed with variation of location, numbers and depths of anchor blocks as well as depth of poles to find stresses acting on concrete electric poles. The stresses of concrete poles are relaxed at 600~700[kg] of tensile load, and stresses are concentrated at top of pole, and spread to lower part of pole. In the concrete pole collapse test, tensile load at failure was approximately 1,400[kg], which is twice of design load. As passive zone in the soil increases, the stresses acting on concrete pole are concentrated at lower part of pole based on moment arm earth pressure distribution.

A Design and Driving Characteristics of Novel Hybrid Pole Bearingless SRM (새로운 하이브리드 극 구조의 베어링리스 SRM 설계 및 운전특성)

  • Lee, Dong-Hee;Wang, Hui-Jun;An, Young-Joo;Ahn, Jin-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2202-2207
    • /
    • 2008
  • Bearingless SRM(Switched Reluctance Motor) is researched for high speed or special applications which can not use mechanical bearing such as bio pump. In this paper, a novel hybrid pole bearingless SRM is presented. The proposed hybrid pole bearingless SRM has salient poles for torque and suspending force production. Motor torque is controlled by the phase currents in torque pole windings, and the suspending force is controlled by suspending currents in four suspending windings for radial direction suspension. Because the proposed bearingless SRM has divided pole structure, mutual effects between torque current and suspending current are very lower than the conventional one's. From this structure, the number of power devices for power converter can be reduced for bearingless SRM driving. The proposed hybrid pole bearing less SRM is verified by the FEM analysis and experimental results.

The Fundamental Design Consideration of Salient Pole Rotor Type Single Phase SRM

  • Oh, Young-Woong;Lee, Eun-Woong;Kim, Jun-Ho
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.11B no.2
    • /
    • pp.22-27
    • /
    • 2001
  • Salient pole rotor type single phase switched reluctance motor is of simple and rigid structure, short shaft and simple driving circuit. Especially, the output power per unit volume of salient pole rotor structure is comparatively high because the magnetic fluxes of axial and radial direction are simultaneously used. Therefore, this motor will be used at small space and difficult maintenance situations. In this paper, the selecting method of proper pole arc, stator, and rotor dimension of salient pole rotor type single phase SRM is proposed.