• Title/Summary/Keyword: Polarization of water

Search Result 356, Processing Time 0.036 seconds

A Study on Characteristics of the Electrochemical Corrosion of Weld Zone for Refrigerating and Heating Systems Pipe (냉난방용 배관 용접부의 전기화학적 부식특성에 관한 연구)

  • Lim, Uh-Joh;Yun, Byoung-Du;Kim, Hwan-Sik
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.19 no.1
    • /
    • pp.84-90
    • /
    • 2007
  • This paper was studied on the electrochemical corrosion characteristics of weld zone for refrigerating and heating systems pipe. Austenitic stainless steel is widely applied to various fields of industry, because it is good to corrosion resistance and mechanical properties. But STS 304 is reliable to sensitization by heat cycle on welding. Therefore, in this study, electrochemical polarization test of STS 304 steel pipe manufactured by arc welding in tap water was carried out. And then polarization resistance behavior, uniform and local corrosion behaviors of base metal(BM), weld metal(WM) and heat affected zone(HAZ) for STS 304 pipe were investigated. The corrosion current density of STS 304 steel pipe is high in order of BM(153nA/cm2) < WM(614nA/cm2) < HAZ ($1.675{\mu}A/cm2$). The pitting potential of HAZ(238mV/SCE) for STS 304 is lower than BM(1206mV/SCE) and WM(369mV/SCE). Therefore, the local corrosion like pitting corrosion, galvanic corrosion and crevice corrosion of HAZ for STS 304 is more sensitive than BM and WM.

The Development of Water-Soluble Black Coloring Agent and Its Application (수용성 흑색 착색제의 개발과 이의 응용)

  • Kim, M.G.;Jung, B.H.;Moon, M.J.;Kim, S.S.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.15 no.5
    • /
    • pp.213-218
    • /
    • 2002
  • In order to develop the economic and environmental water-soluble black coloring agent, some adequate chemical mixtures were mixed and this solution was applied to coat quenched and tempered 51B20 steel bolt. Some basic properties of the solution and characteristics of the coated film in addition to the corrosion resistance were investigated. The developed 100 kg of water-soluble black coloring agent solution was a chemical mixture consisted of 10 kg of aqueous coloring agent, 40 kg of surface active agent, 0.3 kg of anti-foam agent and $50{\ell}$ of water. The coated film of the bolt was composed of hard layer of about $2{\mu}m$ and the disbondable soft layer of about $4{\mu}m$ above the hard layer. Many surface active agents peaks and a few hydrophilic peaks were observed in the coated film. Surface roughness value of the coated bolt was lower than that of the non-coated bolt. Corrosion resistance of the coated bolt considerably improved and also relatively showed a good polarization resistance at test condition of $40^{\circ}C$ colorizing temperature and 5% the solution concentration in 3% NaCl anodic polarization test. Initial appearance time of the surface rust was greatly retarded owing to the coated film in salt spray test.

Variation of Dielectric Constant of Sand due to Water Content and Measuring Frequency (수분함량과 측정주파수에 따른 사질토 지반의 유전상수 변화)

  • 이주형;오명학;박준범;김형석
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.6
    • /
    • pp.129-139
    • /
    • 2002
  • Dielectric constant measurement has drawn much attention in the investigation of the properties and contaminations of subsurface. In this study, by varying the frequency from 75 kHz to 12 MHz, dielectric constant was measured for the weathered granite soil and Jumunjin sand having different water contents and dry density. The dielectric constant of sand showed the dispersive behavior indicating that dielectric constant decreased with frequency of an electric field. And the dielectric constant of soil increased as water content and/or dry density increased due to the decrease of air portion and/or the increase of amount of water molecules which could contribute to the development of orientation polarization. The dielectric constant of sand showed a linear relationship with the moisture density, considering both water content and dry density. At low frequency, the dielectric constants calculated by Maxwell's, Topp's and CRIM equation deviated from measured values. It could be explained by the fact that those equations did not consider dispersive behavior of dielectric constant with the frequency.

Complex Dielectric Constant of Soil Contaminated by Landfill Leachate with Measured Frequency (매립지 침출수로 오염된 토양의 측정주파수에 따른 유전특성 변화)

  • Oh Myoung-Hak;Bang Sun-Young;Park Jun-Boum;Lee Ju-Hyung;Lee Seock-Heon;Ahn Kyu-Hong
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.3
    • /
    • pp.1-11
    • /
    • 2004
  • To evaluate the applicability of dielectric constant measurement method on the geoenvironmental investigation of subsurface contaminated by landfill leachate, the analysis on dielectric characteristics of sand containing contaminated pore water by landfill leachate was performed. The separate real and imaginary parts of dielectric constant were investigated in the frequency range of 75kHz to 12MHz. The real part of dielectric constant increased at the lower frequency wherea the real part of dielectric constant decreased at the higher frequency as the concentration of leachate increased. These results can be explained by the frequency dependence of space charge polarization and orientation polarization. The imaginary part of dielectric constant on the contaminated sand with leachate increased with their concentration for whole frequency range. These results are caused by the increase of energy loss due to the enhancement of conduction in soil with leachate concentration. The results in this study indicate that the dielectric constant measurement method has potential in evaluating the contaminated soil and pore water by landfill leachate.

Anodic Oxidation of Silicon in EPW Solution (EPW 용액에서의 실리콘 양극 산화막 형성에 관한 연구)

  • Bu, Jong-Uk;Kim, Seon-Mi;Kim, Seung-Hui;Kim, Seong-Tae;Gwon, Suk-In
    • Journal of the Korean Vacuum Society
    • /
    • v.2 no.2
    • /
    • pp.181-187
    • /
    • 1993
  • We have studied the anodic oxidation of silicon in the anisotropic etchant of EPW(Ethylenediamine, Pyrocatechol and Water) solution using the cyclic polarization technique. The samples have been characterized by means of X-ray photoelectron spectroscopy(XPS) and secondary ion mass spectrometry (SIMS). The results of cyclic polarization experiments show that the anodic oxides formed on p- and n-type silicon wafers break down at the same potential while breakdown does not occur up to open circuit potential in the case of $p^+$-Si. Strong etch-resistance of $p^+$-XPS. SIMS depth profiles suggest that the critical concentration of boron for etch-stop to occur appears to be much higher than what is widely believed.

  • PDF

Cinnamon Plant Extract as Corrosion Inhibitor for Steel Used in Waste Water Treatment Plants and Its Biological Effect on Escherichia coli

  • Fouda, Abd El-Aziz S.;Nazeer, Ahmed Abdel;El-Khateeb, Ayman Y.;Fakih, Mohamed
    • Journal of the Korean Chemical Society
    • /
    • v.58 no.4
    • /
    • pp.359-365
    • /
    • 2014
  • The inhibition effect of cinnamon plant extract as a green corrosion inhibitor for steel in sulfide polluted salt water was studied by potentiodynamic polarization, electrochemical impedance spectroscopy (EIS), and electrochemical frequency modulation (EFM). The results showed that cinnamon plant extract in sulfide polluted salt water is a good corrosion inhibitor with inhibition efficiency reached to 80% at 250 ppm of the plant extract. The adsorption of cinnamon obeys Temkin adsorption isotherm, and acts as a mixed-type of inhibitor but dominantly as a cathodic inhibitor in sulfide polluted salt water.

Effect of Curing Solution and Pre-Rust Process on Rebar Corrosion in the Cement Composite (시멘트 복합체 내부 철근 부식에 양생 용액과 철근 사전 부식이 미치는 영향)

  • Du, Rujun;Jang, Indong;Lee, Hyerin;Yi, Chongku
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.2
    • /
    • pp.1-8
    • /
    • 2022
  • The corrosion of reinforcement is the main reason for the performance degradation of concrete structures. The pre-rusted parts of rebar in concrete structures are vulnerable to the corrosion, especially if the structure is exposed to wet or chlorinated environments. In this study, effects of different curing solution on corrosion behavior of the pre-rusted rebars in the cement composites were investigated. HCl(3%) and CaCl2(10%) solution were utilized to accelerate the pre-rust of the rebar, and each pre-rust condition rebar including reference (RE) were placed in mortar cylinder. Three kinds of samples then were cured in CaCl2 (3%) solution and tap water respectively for 120 days. Electrochemical polarization and half-cell potential measurement were used to monitor the influence of curing water on the corrosion behavior of pre-rusted steel bar in cement composite. The surface morphology and composition of corroded steel bar were analyzed by scanning electron microscope and energy dispersive X-ray diffraction. The results show that the corrosion rates of pre-rusted samples in both curing water are higher than that of non-pre-rusted samples. The corrosion rates of RE, CaCl2 and HCl pre-rusted samples in salt water were 8.14, 4.48, 13.81 times higher than those in tap water respectively, on the 120th day.

Analysis of PVDF Coating Properties with Addition of Hydrophobically Modified Fumed Silica

  • Lee, Nam Kyu;Kim, Young Hoon;Im, Tae Gyu;Lee, Dong Uk;Shon, MinYoung;Moon, Myung Jun
    • Corrosion Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.232-242
    • /
    • 2019
  • In this study, hydrophobically modified fumed silica was added to the PVDF coating to improve corrosion protection performance. Two types of silane modifiers, trimethylchlorosilane (TMCS) and hexamethyldisilazane (HMDZ), were used for hydrophobic modification of the fumed silica. The composition of modified fumed silica was analyzed by Fourier transform infrared, X-ray photoelectron spectroscopy, and elemental analysis. The dispersion of modified fumed silica in the PVDF coating was observed by the transmission electron microscopy, and the hydrophobicity of PVDF coating was analyzed by the water contact angle. Surface properties were examined by the field emission scanning electron microscopy and scanning probe microscopy. Potentiodynamic polarization was conducted to confirm corrosion protection performance of PVDF coating in terms of hydrophobically-modified fumed silica contents. As a result, the average surface roughness and the water contact angle of the PVDF coating increased with modifier contents. The results of the potentiodynamic polarization test showed an increase of the Ecorr values with increase of the hydrophobicity of PVDF coating. Thus, it clearly indicates that the corrosion protection performance of PVDF coating improved with the addition of the hydrophobic-modified fumed silica that prevents the penetration of moisture into the PVDF coating.

Electrochemical Evaluation of Si-Incorporated Diamond-Like Carbon (DLC) Coatings Deposited on STS 316L and Ti Alloy for Biomedical Applications

  • Kim, Jung-Gu;Lee, Kwang-Ryeol;Kim, Young-Sik;Hwang, Woon-Suk
    • Corrosion Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.18-23
    • /
    • 2007
  • DLC coatings have been deposited onto substrate of STS 316L and Ti alloy using r.f. PACVD (plasma-assisted chemical vapor deposition) with a mixture of $C_{6}H_{6}$ and $SiH_{4}$ as the process gases. Corrosion performance of DLC coatings was investigated by electrochemical techniques (potentiodynamic polarization test and electrochemical impedance spectroscopy) and surface analysis (scanning electron microscopy). The electrolyte used in this test was a 0.89% NaCl solution of pH 7.4 at temperature $37^{\circ}C$. The porosity and protective efficiency of DLC coatings were obtained using potentiodynamic polarization test. Moreover, the delamination area and volume fraction of water uptake of DLC coatings as a function of immersion time were calculated using electrochemical impedance spectroscopy. This study provides the reliable and quantitative data for assessment of the effect of substrate on corrosion performance of Si-DLC coatings. The results showed that Si-DLC coating on Ti alloy could improve corrosion resistance more than that on STS 316L in the simulated body fluid environment. This could be attributed to the formation of a dense and low-porosity coating, which impedes the penetration of water and ions.

Backscattering Features of Oyster Sea Farming in AIRSAR Image and Laboratory Experiment

  • Lee Seung-Kuk;Hong Sang-Hoon;Won Joong-Sun
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.582-585
    • /
    • 2004
  • Oyster fanning structures in tidal flats are well detected by SAR system. Each frame of these artificial structures is composed of two vertical and one horizontal wooden pole. We investigate characteristics of polarimetric features in the target structures. In this paper, the results of AIRSAR L-band POLSAR data and experiments in laboratory are discussed. The ratio of single bounce to double bounce scattering depends of vertical pole height, direction of horizontal pole to radar look direction, and incidence angle as well as sea surface condition. We have conducted laboratory experiments. According to target scale, Ku-band and targets downsized by scale of 10 are used. The results of the experiments are summarized as: i) total power of the backscattering is more affected by vertical poles than a horizontal pole; ii) and backscattering from a horizontal pole is sensitive to the relative radar look direction to target array. We conclude that water level can be effectively measured by using interferometric phase and backscattering intensity if vertical poles in the water are observed by L-band HH- or VV-polarization. Measurement of tide height can be further improved if double bounced components are separated from fully polarized SAR data.

  • PDF