• Title/Summary/Keyword: Polarization Maintenance

Search Result 27, Processing Time 0.025 seconds

A Servicism Model of the New Financial System (서비스주의 금융시스템 연구)

  • Hyunsoo Kim
    • Journal of Service Research and Studies
    • /
    • v.12 no.1
    • /
    • pp.49-68
    • /
    • 2022
  • This study was conducted to design a financial system for the sustainable life of mankind. Human society faces a constant crisis and leads a life while overcoming it. The polarization is intensifying in the process of overcoming the economic crisis or crisis caused by the virus. In a society adopting the capitalist economic system, it is a common phenomenon that polarization intensifies with the passage of time, but since the intensification of polarization can destroy human society as a community, active countermeasures are required. The purpose of this study was to prevent the deepening of polarization by redesigning important financial-related systems from the perspective of human life and maintenance of human society. Through the history of mankind, monetary and financial systems related to sustainable society have been analyzed, and a financial system model that is ideal for the modern and future society and is sustainable in the long term has been derived. The conditions for a long-term sustainable financial system should be a model that can solve the problems of the current system, such as deepening polarization, and a model that is faithful to the characteristics of the modern economic society and the essence of sustainable life. And it can be sustainable only if it is based on the common principles of human society. It should be a model that guarantees core values such as growth and equality that human society demands. After analyzing the problems of the current economic system and analyzing the conditions required for the new system, the basic axioms that the new financial system should be based on were presented, and a desirable model was derived based on this. The structure of the derived model and the specific operation model were presented. In the future, follow-up studies are needed to concrete this model.

Development and Application of Anti-Corrosive Steel Using Electro-Deposition of Sea Water (1) -Development of Electro-Deposition System Using Sea Water (해수전착 코팅을 이용한 내부식성 철근의 개발 및 적용성에 대한 연구 (1) -해수전착 코팅 시스템 개발)

  • Kwon, Seung Jun;Lee, Myeong Hoon;Park, Sang Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.5
    • /
    • pp.78-87
    • /
    • 2012
  • This study is for developing a system for electro-deposition utilizing sea water containing various ions like calcium and magnesium. This is the first step research for the final goal which is a development of anti-corrosive steel for RC structure, so that this paper is mainly focused on the development for electro-deposition system. Optimum conditions for steel coating is obtained through various tests considering anode type, temperature, duration time, and current density. The composition of electro-deposition is analyzed through SEM, EDS, and XRD and it is evaluated to be $CaCO_3$ and $Mg(OH)_2$. Through measuring polarization potential and current density in the coated steel, the coating layer from the developed system is evaluated to have high resistance to steel corrosion. Additional tests and discussions on durability and structural performance in the coated steel from this work will be performed for the second step research.

An Experimental Study of the Corrosion Behavior Evaluation of Rebar in Concrete by Using Electrochemical Impedance Spectroscopy (EIS) Method (EIS를 이용한 콘크리트 내부 철근의 부식거동평가에 관한 실험적 연구)

  • Park, Jang-Hyun;Lee, Han-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.1
    • /
    • pp.83-90
    • /
    • 2017
  • The corrosion behavior of a rebar in concrete according to the amount of NaCl and $LiNO_2$ was observed by using Electrochemical Impedance Spectroscopy. The corrosion was accelerated in a short time by using dry/wet cycles method, which is one of the corrosion acceleration methods, and though the value of measured impedance, equivalent circuit can be introduced. It was confirmed that the passive film of a embedded rebar in concrete with NaCl was broken quickly, and when $0.6M\;LiNO_2$ was added, the velocity of ongoing corrosion was declined considerably compared to the amount of NaCl. However, when $1.2M\;LiNO_2$ was added, it was confirmed that the passive film was not broken and its performance remained, compared to the amount of NaCl.

Review of Basics Reverse Osmosis Process Modeling: A New Combined Fouling Index Proposed (역삼투 공정을 위한 모델링 총설 및 새로운 복합적 막오염도의 제안)

  • Kim, Albert S.
    • Membrane Journal
    • /
    • v.27 no.4
    • /
    • pp.291-312
    • /
    • 2017
  • Seawater desalination is currently considered to be one of the primary technologies to resolve the global water scarcity problem. A basic understanding of membrane filtration phenomena is significant not only for further technological development but also for integrated design, optimal control, and long-term maintenance. In this vein, the present work reviews the major transport and filtration models, specifically related to reverse osmosis phenomena, provides theoretical insights based on statistical mechanics, and discusses model-based physical meanings as related to their practical implications.

Corrosion Damage Behavior of STS 304 and STS 415 for Reactor Coolant Pump during Ultrasonic-Chemical Decontamination Process (원자로 냉각재 펌프용 STS 304와 STS 415의 초음파-화학제염 공정 시 부식 손상 거동)

  • Hyeon, Gwang-Ryong;Park, Jae-Cheol;Han, Min-Su;Kim, Seong-Jong
    • Journal of the Korean institute of surface engineering
    • /
    • v.51 no.4
    • /
    • pp.218-223
    • /
    • 2018
  • In this study, we proposed a new ultrasonic-chemical decontamination process for decontaminating radioactive corrosion products during the maintenance of reactor coolant pump (RCP). The actual decontamination process was reproduced in the laboratory. And the corrosion characteristics of stainless steel (STS), constituting the RCP interior parts, were examined. The weight-loss measurment and polarization experiment were carried out in order to determine the corrosion characteristics of STS 304 and STS 415 by repeated decontamination processes. The STS 304 presented a little corrosion damage, which was almost indistinguishable from visual observation. The weight-loss rate of STS 304 was also significantly lower. On the other hand, STS 415 showed severe corrosion damage on its surface, greater weight-loss rate and higher corrosion current density than STS 304.

Effect of the Amplitude in Ultrasonic Nano-crystalline Surface Modification on the Corrosion Properties of Alloy 600

  • Kim, Ki Tae;Kim, Young Sik
    • Corrosion Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.196-205
    • /
    • 2019
  • Surface modification techniques are known to improve SCC by adding large compressive residual stresses to metal surfaces. This surface modification technology is attracting attention because it is an economical and practical technology compared to the maintenance method of existing nuclear power plants. Surface modification techniques include laser, water jet and ultrasonic peening, pinning and ultrasonic Nano-crystal surface modification (UNSM). The focus of this study was on the effect of ultrasonic amplitude in UNSM treatment on the corrosion properties of Alloy 600. A microstructure analysis was conducted using an optical microscope (OM), scanning electron microscope (SEM) and electron backscattering diffraction (EBSD). A cyclic polarization test and AC-impedance measurement were both used to analyze the corrosion properties. UNSM treatment influences the corrosion resistance of Alloy 600 depending on its amplitude. Below the critical amplitude value, the pitting corrosion properties are improved by grain refinement and compressive residual stress, but above the critical amplitude value, crevices are formed by the formation of overlapped waves. These crevices act as corrosion initiators, reducing pitting corrosion resistance.

Corrosion Behavior of Bimetal Materials (Fe-Ni / Fe-Ni-Mo) for Electromagnetic Switches (전자 개폐기용 바이메탈 소재(Fe-Ni / Fe-Ni-Mo)의 부식거동)

  • Yu-Jeong An;Eun-Hye Hwang;Jae-Yeol Jeon;Sung Jin Kim
    • Corrosion Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.478-483
    • /
    • 2023
  • This study examined the corrosion behavior of bimetal materials composed of Fe-Ni alloy and Fe-Ni-Mo alloy, both suitable for use in electromagnetic switches. Electrochemical polarization and weight loss measurements revealed that, in contrast to Fe-Ni alloy, which exhibited pseudo-passivity behavior, Fe-Ni-Mo alloy had higher anodic current density, displaying only active dissolution and greater weight loss. This indicated a lower corrosion resistance in the Fe-Ni-Mo alloy. Equilibrium calculations for the phase fraction of precipitates suggested that the addition of 1 wt% Mo may lead to the formation of second-phase precipitates, such as Laves and M6C, in the γ matrix. These precipitates might degrade the homogeneity of the passive film formed on the surface, leading to localized attacks during the corrosion process. Therefore, considering the differences in corrosion kinetics between these bimetal materials, the early degradation caused by galvanic corrosion should be prevented by designing a new alloy, optimizing heat treatment, or implementing periodic in-service maintenance.

EIS monitoring on corroded reinforcing steel in cement mortar after calcium electro-deposition treatment (칼슘 전착처리 후, 시멘트 모르타르 속 철근의 부식속도에 대한 EIS 모니터링)

  • Kim, Je-Kyoung;Kee, Seong-Hoon;Yee, Jurng-Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.1-8
    • /
    • 2019
  • The primary purposes of this study are to understand a fundamental effects of electro-deposition on reinforcing steel in saturated Ca(OH)2 electrolyte, and evaluate the corrosion rates of rebars under cyclic 3wt.%NaCl immersion and dry corrosion environment. The three cement mortar specimens with cover thickness 5, 10 and 30mm, were prepared in the experiment. To monitor the corrosion rates of rebars in mortar, the three cement mortar specimens were exposed to 110 wet-drying cycles(8-hour-immersion in 3wt.%NaCl and 16-hour-drying in a room temperature) in the laboratory. During the wet-dry cycles, the polarization resistance, Rp, and solution resistance, Rs, were continuously measured. The instantaneous corrosion rates of rebars on the effect of electro-depositing with sat. Ca(OH)2 electrolyte were estimated from obtained R-1p and degrees of wetness were estimated from Rs values. From the experimental results, the corrosion rates of rebars were greatly accelerated by wet/dry cycles. During the mortars exposed to drying condition, the large increases in the corrosion rates were showed at all rebar surfaces in three mortar specimen, attributed from the accelerated reduction rates of dissolved oxygen in drying process. However, the corrosion rates on rebar surface electrochemically deposited with sat. Ca(OH)2 electrolyte showed the clear decreases, caused by calcium deposits in the porous rust layer.

Electrochemical Studies on the Corrosion Performance of Steel Embeded in Activated Fly Ash Blended Concrete (활성화된 플라이애쉬 혼입콘크리트의 철근부식거동에 관한 전기화학적 연구)

  • Song, Ha-Won;Lee, Chang-Hong;Lee, Kewn Chu;Velu, Saraswathy
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.6
    • /
    • pp.97-108
    • /
    • 2008
  • The use of fly ash to replace a portion of cement has resulted significant savings in the cost of cement production. Fly ash blended cement concretes require a longer curing time and their early strength is low when compared to ordinary Portland cement(OPC) concrete. By adopting various activation techniques such as physical, thermal and chemical method, hydration of fly ash blended cement concrete was accelerated and thereby improved the corrosion-resistance of concrete. Concrete specimens prepared with 10-40% of activated fly ash replacement were evaluated for their open circuit potential measurements, weight loss measurements, impedance measurements, linear polarization measurements, water absorption test, rapid chloride ion penetration test and scanning electron microscopy (SEM) test and the results were compared with those for OPC concrete without fly ash. All the studies confirmed that up to a critical level of 20-30% replacement; activated fly ash cement improved the corrosion-resistance properties of concrete. It was also confirmed that the chemical activation of fly ash better results than the other methods of activation investigated in this study.

Evaluation of Ozone Resistance and Anti-Corrosion Performance of Water Treatment Concrete according to Types of Metal Spray Coating (수처리시설용 콘크리트의 금속용사 피막 종류에 따른 내오존성 및 전기화학적 방식 성능 평가)

  • Park, Jin-Ho;Choi, Hyun-Jun;Lee, Han-Seung;Kim, Sang-yeol;Jang, Hyun-O
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.61-68
    • /
    • 2019
  • As the pollution of water resources deteriorates due to industrialization and urbanization, it is difficult to supply clean water through a water treatment method using chlorine. Therefore, the introduction of advanced water treatment facilities using ozone is on the increase. However, epoxy which is used as waterproofing and anticorrosives and stainless steel used in conventional waterproofing and anti-corrosive methods have deteriorated because of the strong oxidizing power of ozone, causing problems such as leaking. Moreover, it even causes the durability degradation of a concrete. Therefore, in this study, metal spraying system was used as the means of constructing a metal panel with excellent ozone resistance and chemical resistance which is an easier method than an existing construction method. Ozone resistance was evaluated in accordance with the type of metal sprayed coatings to develop a finishing method which can prevent the concrete structure of water treatment facilities from deterioration. Furthermore, electrochemical stability in actual sewage treatment plant environment was evaluated. Experimental results showed that Ti has superior ozone resistance after spraying and the electrochemical stability in the sewage treatment plant environment showed that Ti has the highest polarization resistance of $403.83k{\cdot}{\Omega}{\cdot}cm^2$, which ensures high levels of durability.