• Title/Summary/Keyword: Polarization Curve

Search Result 220, Processing Time 0.022 seconds

Study of Voltage Loss on Polymer Electrolyte Membrane Fuel Cell Using Empirical Equation (Empirical Equation을 이용한 고분자전해질 연료전지의 전압 손실에 대한 연구)

  • Kim, Kiseok;Goo, Youngmo;Kim, Junbom
    • Applied Chemistry for Engineering
    • /
    • v.29 no.6
    • /
    • pp.789-798
    • /
    • 2018
  • The role of empirical equation to predict the performance of polymer electrolyte membrane fuel cell is important. The activation, ohmic and mass transfer losses were separated in a polarization curve, and the curve fitting according to each region was performed using Kim's model and Hao's model. Changes of each loss were compared according to operation variables of the temperature, pressure, oxygen concentration and membrane thickness. The existing model showed a good fitting convergence, but less fitting accuracy in the separated loss region. A new model using the convergence coefficient was suggested to improve the accuracy of performance prediction of fuel cells of which results were demonstrated.

정전위법에 의한 Alloy 600의 입계응력부식균열 거동 연구

  • 맹완영;강영환;일본명
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05c
    • /
    • pp.111-116
    • /
    • 1996
  • IGSCC(Intergranular stress corrosion cracking) behaviors of Alloy 600 were studied by the electrchemical ten methods of controlling specimens electrode potentials in the active-passive transition region of anodic polarization curve. Anodic polarization and static potential tests of stressed C-ring type MA Alloy 600 were carried out in 10% NaOH at 300 $^{\circ}C$ for 7days. It was confirmed that IGSCC of Alloy 600 was accellerated by maintaining the specimen potential in the susceptible active-passive transition region of anodic polarization curve. An intergranular crack was initiated on the surface area of C-ring specimens where protective oxide layer was broken down. And the depth of the crack growth was about 100 ${\mu}$m during the testing periods.

  • PDF

Potential Difference of Cyclic Polarization Curve of an Aircraft Al Alloy: ∆E (Esec,corr - Ecorr)

  • Sun, Qingqing;Chen, Kanghua
    • Journal of Electrochemical Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.140-147
    • /
    • 2020
  • This paper presents a hypothesis and its experimental validation that ∆E (Esec,corr - Ecorr) of cyclic polarization curve of an Al-Zn-Mg-Cu alloy decreases firstly and then increases with the increasing of corrosion rate or corroded fraction Fcorr of alloy surface. The minimum value of ∆E is obtained when Fcorr ≈ 50%. In addition, a proportional relationship between ∆E and |50% - Fcorr| was found. This non-monotonic relation between ∆E and extent of localized corrosion indicates that additional attention should be paid on using ∆E to assess localized corrosion behaviour of Al-Zn-Mg-Cu alloys.

The Study on the Behavior of Polarization curve of Reinforcement with Oxidation Layer (산화피막이 있는 철근의 분극곡선의 거동에 대한 연구)

  • 한정섭
    • Journal of Ocean Engineering and Technology
    • /
    • v.14 no.1
    • /
    • pp.60-66
    • /
    • 2000
  • In order to study for corrosion behavior of reinforcing steel with oxidation layer. Experiments were done with various NaCl concentrations and with immersion time in simulated concrete pore solution(SPS) the characteristics of corrosion behavior were measured by polarization resistance method and cyclic potentiodynamic method. reinforcements were coated by epoxy except corrosion without oxidation layer and it also showed two anodic-nose. by the result of potention dynamic test the potential curve shift to low with time and anodic-nose was appeared with 3% NaCl solution after 15 days. By result of cyclic Potentiodynamic test the type of corrosion was different accoding to concentration.

  • PDF

Corrosion Resistance of the Roll Formed Steel Bolts with the Various Types of Coating Methods (2) (다양한 코팅 방법에 따른 전조한 강 볼트의 내부식성 (2))

  • Mamatov, S.;Hamrakulov, B.;Son, Y.H.;Kim, I.
    • Transactions of Materials Processing
    • /
    • v.28 no.2
    • /
    • pp.77-82
    • /
    • 2019
  • Corrosion occurs well on surface of roll formed and Zn alloy subsequently electro-deposited on steel bolt under wet condition. In this study, variations in corrosion resistance were investigated through the measurement of polarization curves on steel bolts which were roll formed and subsequently coated with various types of coating methods. According to the measured polarization curve, Ni-P electroless deposits on roll formed steel increased the resistance to corrosion. The corrosion resistance of Zn alloy powder coated steel bolt was found to be better than that of Zn-Ni electro-deposited sample.

A Study on the Electrochemical Characteristics of Al-Si Casting Alloys in NaCl Solution (NaCl 수용액에서 Al-Si계 주조용 합금의 전기화학적 특성 연구)

  • Woo, Sang-Hyun;Son, Young-Jin;Lee, Byung-Woo
    • Journal of Power System Engineering
    • /
    • v.18 no.6
    • /
    • pp.29-33
    • /
    • 2014
  • The electrochemical characteristics of Al-Si casting alloys (Al-10%Si, Al-9%Si, Al-7%Si) in 3.5% NaCl solution at room temperature was studied using potentiodynamic techniques. The electrochemical values of corrosion potential($E_c$), corrosion current density($I_c$) and corrosion rate(mpy) were examined. The Al-Si alloys had several compounds such as $Mg_2Si$, ${\pi}$-$Al_8Si_6Mg_2Fe$ and $Al_2CuMg$ which could affect corrosion resistance significantly. The potentiodynamic polarization curve exhibited typical active behavior in anodic polarization curve. The major corrosion mechansim for the Al-Si alloys were pitting and grain boundary corrosion. As increasing Si and Cu contents, their corrosion resistance was decreased.

Evaluation on Design Factors of Electrolytic Flotation Reactor by Measuring Polarization Curve (분극곡선 측정을 통한 전해부상조의 설계인자 평가)

  • Lim, Bong-Su;Jin, Jing-Zhu;Choi, Chan-Soo
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.2
    • /
    • pp.244-250
    • /
    • 2007
  • This study was carried out to obtain the optimum design factors for an eletrolytric flotation reactor. When the effluent of the leachate treatment facility was treated under the condition of 10 volts, 30 minutes, at the Al-Al electrode system; COD removal efficiency was 45%, and total phosphorus removal efficiency was 98%. The high removal efficiency was caused by the fact that phosphate was removed by leaching $Al^{3+}$ from two electrodes. The leachate containing high ammonium nitrogen concentration was treated by a batch test under the condition of 60 minutes reaction time and added chloride ion; ammonium nitrogen removal efficiency was 89%. This high efficiency was affected by added chloride ion to wastewater. To find the optimum current density and voltage of the leachate containing chloride ion (ratio of $Cl^-/NH_4-N$ is 11) a electrochemical polarization curve was used. These values were found to be $4.5mA/cm^2$ and about 2.1 V, respectively. When C-Al electrode system was used at a batch test, the total nitrogen removal efficiency was increased by 1.8 to 3.3 times, compared to Al-Al electrode system due to high $Cl_2$ gas production.

Effects of organic additives in cyanide zinc electroplating Bath(Part 2) (시안화아연 도금욕에 있어서 유기화합물 첨가제의 영향 (제 2 보))

  • Lee, Ju-Seong;Park, Jung-Il
    • Journal of the Korean institute of surface engineering
    • /
    • v.12 no.3
    • /
    • pp.174-179
    • /
    • 1979
  • The effects of brightness, electrochemical behaviour on the organic additives, such as aldehydes, polymers, amines and condensed product obtained from epichlorohydrin and nicotinamide, in cyanide zinc electrolplating bath have been studied by controlled potential electrolyser. The results were summerized as follows: (1) It was found that the addition of only one compound of these organic compounds in the bath was unsuitable but mixture of anisaldehyde or monoethanolamine and condensed product as suitable as brightener. (2) The cathodic polarization curve of polymers or aldehydes in cyanide zinc electroplating bath was almost the same but the cathodic polarization curve of condensed product remarkable shifted to noble potential more than non-additive curve.

  • PDF

Corrosion Characteristics with Polarization Curve of Polymers

  • Park, Chil-Nam;Jung, Oh-Jin
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.10 no.S_4
    • /
    • pp.181-187
    • /
    • 2001
  • This study was carried out to measure the variations of potential and current density with polymers. The results were particularly examined to identify the influences on potential and rate of various factors including temperature and pH. The Tafel slope for anodic dissolution was determined by the polarization effect depending on these conditions. The optimum conditions were established for each case. The second anodic current density peak and maximum current density were designated as the relative polarization sensitivity$(I_r/I_f)$. The mass transfer coefficient value$(\alpha)$ was determined with the Tafel slope for anodic dissolution based on the polarization effect with optimum conditions.

  • PDF

An Electrochemical Evaluation on the Corrosion Resistance of Heavy Anticorrosive Paint (중방식도료의 내식성에 관한 전기화학적 평가)

  • Sung Ho-Jin;Kim Jin-Kyung;Lee Myung-Hoon;Kim Ki-Joon;Moon Kyung-Man
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.5
    • /
    • pp.519-525
    • /
    • 2005
  • An electrochemical evaluation on the corrosion resistance for heavy anticorrosive paint(DFT:25um) was carried out for 5 kinds of heavy anticorrosive paints such as high solid epoxy(HE), solvent free epoxy(SE). tar epoxy(TE), phenol epoxy(PE). and ceramic epoxy(CE). Corrosion current densities obtained by Tafel extrapolation method from anodic and cathodic polarization curves didn't correspond with the values obtained by AC impedance measurement, however, the values of polarization resistance obtained from the cyclic voltammogram showed a good tendency corresponding well with the values of AC impedance measurement. Futhermore there was a good correlation against the corrosion resistance evaluation between passivity current density of the anodic polarization curve and diffusion limiting current density of the cathodic polarization curve. And corrosion resistance increased with corrosion potential shifting to noble direction. From the results discussed above. HE and CE had a relatively good corrosion resistance than other heavy anticorrosive paints.