• 제목/요약/키워드: Point Source Bypass

검색결과 6건 처리시간 0.019초

3상 전압변동발생기의 직렬변압기 바이패스용 SCR의 스위칭 특성해석 (Switching Characteristics Analysis of Bypass SCR for Series Transformer in 3-phase Voltage Disturbance Generator)

  • 송웅협;박해영;노의철;김인동;김흥근;전태원
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.71-72
    • /
    • 2010
  • This paper deals with the SCR thyristor switching characteristics of a 3-phase voltage disturbance generator. The series transformers of the generator require bypass SCR thyristors to provide the source voltage to the output terminal in normal operating mode. The SCR thyristor switching characteristics is quite different according to the connection point to the series transformer. The switching characteristics is analysed and verified through simulation results.

  • PDF

3상 전압변동발생기의 직렬변압기 바이패스용 SCR의 스위칭 특성해석 (Switching Characteristics Analysis of Bypass SCR for Series Transformer in 3-phase Voltage Disturbance Generator)

  • 송웅협;박해영;노의철;김인동;김흥근;전태원
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.532-533
    • /
    • 2010
  • This paper deals with the SCR thyristor switching characteristics of a 3-phase voltage disturbance generator. The series transformers of the generator require bypass SCR thyristors to provide the source voltage to the output terminal in normal operating mode. The SCR thyristor switching characteristics is quite different according to the connection point to the series transformer. The switching characteristics is analysed and verified through simulation results.

  • PDF

낙동강 유역 내 하수처리구역의 비점 배출 부하량 분석 (Analysis on Load of Non-point Source from Sewage Treatment Districts in Nakdong River)

  • 신현석;김미은;김재문;장종경
    • 한국수자원학회논문집
    • /
    • 제48권9호
    • /
    • pp.695-709
    • /
    • 2015
  • 지속적인 개발과 도시화로 인하여 하천으로 유입되는 비점오염원의 비율 역시 점차 증가하는 추세이며 비점오염원이 수질악화에 미치는 영향은 점점 더 커지고 있다. 하천의 수질오염을 발생시키는 비점오염원 해결방안을 모색하고 있지만 도시화에 따른 수문현상변동 및 자연현상과 관련된 문제라 연구에 어려움이 많다. 본 연구에서는 기존의 총량원단위법과 달리 유역의강우 및 도시화 특성과 처리장 운영자료를 활용하여 차별화된 비점오염원 산정 방법을 제시하였다. 하수처리장의 배수구역 내 관거시스템을 합류식으로 가정하여 강우 시 하수처리장의 배수구역별 비점 발생형태는 하수처리장 강우유 입량, 하수처리장 우회유량(bypass) 및 하천토구의 CSO의 3가지로 크게 구분하여 적용함으로써 오염부하량을 산정함으로써 오염총량 단위유역 및 하수처리구역의 관리를 위한 비교자료로 활용 가능할 것으로 판단된다.

지능형 SQL Query 분석을 통한 Application Layer 역추적 연구 (A Study of Application Layer Traceback Through Intelligent SQL Query Analysis)

  • 백종일;박대우
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2010년도 춘계학술대회
    • /
    • pp.265-268
    • /
    • 2010
  • 현재의 IP 위주의 역추적은 Proxy와 우회기법의 발달로 인하여 Real IP 역추적에 어려움이 있다. 또한 IP역추적 후에도 실제 Source IP인지 확인이 어렵다. 따라서 본 논문에서는 지능형 SQL Query에 대한 field, column, table 등의 요소값과 매칭되는 key값을 분석하고 여기에서 사용되는 Data값의 hit point를 분석하여 최초 사용자에 대한 Application Layer를 분석함으로써 IP 역추적에 대한 포렌식 증거로 삼는다. 본 연구는 포렌식과 DB보안 등 전자거래 발전에 기여할 것이다.

  • PDF

저온수열원이용 열펌프시스템의 전처리 및 성능분석 (Performance Analysis and Prior-Treatment of Heat Pump System with Low-Temperature Water Heat Source)

  • 박성룡;장기창;이상남;라호상;박준택
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.258-263
    • /
    • 2000
  • River water is higher in temperature than the surrounding environment during the winter. It is highly suitable a heat source for heat pump system. Despite its suitability, however, it is not widely used, due to its fouling and corrosive nature in heat exchanger tubes of evaporator. It is designed prior-treatment system which come into direct contact with the river water, such as auto-seamer, ozone generator for bactericidal test and auto-cleaning system. And it is analyzed treatment effects for its operation. It is designed two-stage compression heat pump system using R-134a with heating load 35.16kW, ad analyzed its performance. As a result it is obtained 3.08 COP when mid-point pressure is 1,200kPa, and bypass ratio of flowing refreigerant to high-stage compressor is 25.1%

  • PDF

농업용 저수지의 점오염원 바이패스 효과 평가를 위한 EFDC 모델의 적용 (Application of EFDC Model to an Agricultural Reservoir for Assessing the Effect of Point Source Bypassing)

  • 김동민;박형석;정세웅
    • 한국농공학회논문집
    • /
    • 제58권6호
    • /
    • pp.9-21
    • /
    • 2016
  • Agricultural reservoirs in Korea have been recognized as an emerging resource for recreational and cultural activities for residents. However, most of the reservoirs are eutrophic and showing high level of contamination with nuisance algal bloom and offensive odor during the summer. For better management and restoration of the reservoirs' water quality, scientific modeling approaches could be used to diagnose the problems and evaluate the efficacy of alternative control measures. The objectives of this study were to validate the performance of a three-dimensional (3D) hydrodynamic and water quality model (Environmental Fluid Dynamics Code, EFDC) for a eutrophic agricultural reservoir and assess the effect of bypassing of the effluent from a wastewater treatment plant on the reservoir water quality. The 3D model successfully simulated the temporal variations of water temperature, DO, TOC, nitrogen and phosphorus species and Chl-a observed in 2014 and also captured their spatial heterogeneity in the reservoir. The simulation results indicated that the point source bypassing may reduce the T-N and T-P concentrations of the reservoir by 6.6 ~ 8.2 %, and 1.7 ~ 16.8 %, respectively. The bypassing, however, showed a marginal effect on the control of TOC due to the increased algal biomass associated with the increased water retention time after bypassing as well as the lower TOC level of the effluent compared to the ambient reservoir water.