• 제목/요약/키워드: Point Resolved Spectroscopy

검색결과 29건 처리시간 0.026초

Characterization of a LSCF/GDC Cathode Composite in Solid Oxide Fuel Cells Using Impedance Spectroscopy

  • Hwang, Jin-Ha;Lee, Byung-Kook
    • 한국세라믹학회지
    • /
    • 제42권12호
    • /
    • pp.793-799
    • /
    • 2005
  • A composite cathode of LSCF$(La_{0.6}Sr_{0.4}Co_{0.2}Fe_{0.8}O_3)\;and\;GDC\; (Gd_2O_3-doped\;CeO_2:Ce_{0.9}Gd_{0.1}O_{1.95_})$ was characterized in terms of an electrode response, using a point contact in an Yttria-Stabilized Zirconia (YSZ) electrolyte incorporated into AC two-point impedance spectroscopy. The point-contacted configuration amplifies the responses occurring near the YSZ/cathode interface through the aligned point contact on the planar LSCF/GDC electrode. The point contact interface increases the bulk resistance allowing the estimation of the point contact geometry and resolving the electrode-related responses. The resultant impedance spectra are analyzed through an equivalent circuit model constructed by resistors and constant phase elements. The bulk responses can be resolved from the electrode-related portions in terms of spreading resistance. The electrode-related polarizations are measured in terms of temperature and oxygen partial pressure. The modified impedance spectroscopy is discussed in terms of methodology and analytical aspects, toward resolving the electrode-polarization issues in solid oxide fuel cells.

각도분해 광전자 분광법을 이용한 2차원 전이금속 칼코겐 화합물의 전자구조 연구 (Investigation on 2D Transition Metal Chalcogenide Using Angular-Resolved Photoelectron Spectroscopy)

  • 박수형
    • 세라미스트
    • /
    • 제22권4호
    • /
    • pp.350-356
    • /
    • 2019
  • Recently, transition metal dichalcogenide (TMDC) monolayers have been the subject of research exploring the physical phenomenon generated by low dimensionality and high symmetry. One of the keys to understanding new physical observations is the electronic band structure of 2D TMDCs. Angle-resolved photoelectron spectroscopy (ARPES) is, to this point, the best technique for obtaining information on the electronic structure of 2D TMDCs. However, through ARPES research, obtaining the long-range well-ordered single crystal samples always proves a challenging and obstacle presenting issue, which has been limiting towards measuring the electronic band structures of samples. This is particularly true in general 2D TMDCs cases. Here, we introduce the approach, with a mathematical framework, to overcome such ARPES limitations by employing the high level of symmetry of 2D TMDCs. Their high symmetry enables measurement of the clear and sharp electronic band dispersion, which is dominated by the band dispersion of single-crystal TMDCs along the two high symmetry directions Γ-K and Γ-M. In addition, we present two important studies and observations for the direct measuring of the exciton binding energy and charge transfer of 2D TMDCs, both being established by the above novel approach.

Relative Comparison of Cathode Polarizations in Solid Oxide Fuel Cells Using the Spreading Concept in AC 2 Point Impedance Spectroscopy

  • Lee, Byung-Kook;Kim, Eui-Hyun;Hwang, Jin-Ha
    • 한국세라믹학회지
    • /
    • 제50권2호
    • /
    • pp.163-167
    • /
    • 2013
  • A modified two-point impedance spectroscopy technique exploits the geometric constriction between an electrolyte and a cathode with an emphasis on semispherical-shaped electrolytes. The spatial limitation in the electrolyte/electrode interface leads to local amplification of the electrochemical reaction occurring in the corresponding electrolyte/electrode region. The modified impedance spectroscopy was applied to electrical monitoring of a YSZ ($Y_2O_3$-stabilized $ZrO_2$)/SSC ($Sm_{0.5}Sr_{0.5}CoO_3$) system. The resolved bulk and interfacial component was numerically analyzed in combination with an equivalent circuit model. The effectiveness of the "spreading resistance" concept is validated by analysis of the electrode polarization in the cathode materials of solid oxide fuel cells.

시간분해 광반사 분광기술을 이용한 LT-GaAs 반도체 운반자의 초고속 거동 연구 (Ultrafast carrier dynamics study of LT-GaAs semiconductors by using time-resolved photoreflectance spectroscopy)

  • 서정철;이주인;임재영
    • 한국광학회지
    • /
    • 제10권6호
    • /
    • pp.482-486
    • /
    • 1999
  • 시간분해 광반사율 측정장치를 구성하여 저온에서 성장된 GaAs 시료에서의 초고속 운반자 거동을 연구하였다. LT-GaAs 반도체에서 운반자에 의하여 발생된 시간분해 광반사율은 결정 구조의 왜곡으로 레이저 파장에 강하게 의존한다. LT-GaAs 반도체에 존재하는 깊은 포획상태로 운반자가 빠르게 포획되기 때문에 시간분해 광반사율은 1 ps 이하의 빠른 소멸 특성을 갖게 되며, 깊게 포획된 운반자에 의하여 느린 소멸 특성을 갖는 광반사율이 유도된다.

  • PDF

폐암의 생체 수소자기공명분광법의 실행가능성 (Feasibility of $In$ $vivo$ Proton Magnetic Resonance Spectroscopy for Lung Cancer)

  • 윤순호;박창민;이창현;송인찬;이현주;구진모
    • Investigative Magnetic Resonance Imaging
    • /
    • 제16권1호
    • /
    • pp.40-46
    • /
    • 2012
  • 목적: 폐암의 생체 수소자기공명분광법의 실행가능성을 탐색하고자 하였다. 대상과 방법: 이 전향적 연구는 해당병원의 임상시험심사위원회로 승인을 받았고 모든 환자로부터 사전동의를 받았다. 병리적으로 폐암으로 확인된 (평균 직경, 56.8 mm; 범위, 44-77 mm) 10명의 환자들에서 (남자 7명, 여자 3명; 평균나이, 64.4세) 단일 복셀 수소자기공명분광기법으로 호흡 유발 PRESS (point-resolved spectroscopic sequence)를 사용하여 1.5 T 수소자기공명 분광법을 시행하였다. 스펙트럼 습득의 기술적 성공률을 평가하고 실패한 증례들의 이유를 고찰하였다. 결과: 10개의 폐암 중 8개 폐암에서 분석 가능한 수소자기공명 분광 스펙트럼을 획득했다 (기술적 성공률, 80%). 두 개의 수소자기공명 분광 데이터는 심각한 기준치 왜곡으로 분석할 수 없었다. 대표적인 대사물질로 choline과 lipid들이 관찰되었다. 결론: 비록 제한적 수의 환자에서의 결과이지만 폐암에서 얻어진 생체 수소 자기공명 분광 스펙트럼이 분석가능하고 높은 성공률로 획득하였기 때문에 폐암 환자에서 호흡 유발 PRESS 방법을 사용한 생체 수소자기공명분광법이 실행가능하다고 판단된다.

Determination of Optimal Scan Time for the Measurement of Downstream Metabolites in Hyperpolarized 13C MRSI

  • Lee, Hansol;Lee, Joonsung;Joe, Eunhae;Yang, Seungwook;Choi, Young-suk;Wang, Eunkyung;Song, Ho-Taek;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • 제19권4호
    • /
    • pp.212-217
    • /
    • 2015
  • Purpose: For a single time-point hyperpolarized $^{13}C$ magnetic resonance spectroscopy imaging (MRSI) of animal models, scan-time window after injecting substrates is critical in terms of signal-to-noise ratio (SNR) of downstream metabolites. Pre-scans of time-resolved magnetic resonance spectroscopy (MRS) can be performed to determine the scan-time window. In this study, based on two-site exchange model, protocol-specific simulation approaches were developed for $^{13}C$ MRSI and the optimal scan-time window was determined to maximize the SNR of downstream metabolites. Materials and Methods: The arterial input function and conversion rate constant from injected substrates (pyruvate) to downstream metabolite (lactate) were precalibrated, based on pre-scans of time-resolved MRS. MRSI was simulated using two-site exchange model with considerations of scan parameters of MRSI. Optimal scan-time window for mapping lactate was chosen from simulated lactate intensity maps. The performance was validated by multiple in vivo experiments of BALB/C nude mice with MDA-MB-231 breast tumor cells. As a comparison, MRSI were performed with other scan-time windows simply chosen from the lactate signal intensities of pre-scan time-resolved MRS. Results: The optimal scan timing for our animal models was determined by simulation, and was found to be 15 s after injection of the pyruvate. Compared to the simple approach, we observed that the lactate peak signal to noise ratio (PSNR) was increased by 230%. Conclusion: Optimal scan timing to measure downstream metabolites using hyperpolarized $^{13}C$ MRSI can be determined by the proposed protocol-specific simulation approaches.

java Based Magnetic Resonance User Interface의 Advanced Method for Accurate, Robust, and Efficient Spectral Fitting 분석방법의 관찰자 변동 요소 (Observer Variation Factor on Advanced Method for Accurate, Robust, and Efficient Spectral Fitting of java Based Magnetic Resonance User Interface for MRS data analysis)

  • 이석준;유승만
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권2호
    • /
    • pp.143-148
    • /
    • 2016
  • 본 연구에서는 MRS 정량적 분석 중 jMRUI AMARES방법의 관찰자의 의존적 원인 요소를 숙련자와 비숙련자의 측정을 통하여 파악하고 하였다. 실험용 10주령 수컷 쥐의 간 부분을 3T MRI 장치를 활용하여 point resolved spectroscopy 펄스시퀀스를 이용하여 자기공명분광 데이터를 획득하였다. 획득된 데이터는 기준 값으로 사용하기 위해서 LCModel software 이용하여 1.3 ppm의 메틸렌 양성자와 4.7 ppm의 물 분자 양성자의 정량 비를 계산하였다. 7명의 비숙련 관찰자는 jMRUI AMARES 방법으로 총 지질을 1, 2주 간격으로 측정한 후 측정된 값을 SPSS를 이용하여 interclass correlation coefficient를 시행하였다. 관찰자 사이 간 측정치의 일관성의 신뢰도 분석을 표현한 크논바 알파 계수는 0.1 미만으로 나타났다. 1주차 데이터 값과 2주차 데이터 값의 평균값은 $0.096{\pm}0.038$로 LCModel의 분석 값보다 0.048로 50% 높게 관찰되었다. jMRUI AMARES분석 방법이 LCModel과 동일한 결과를 얻기 위해서는 정확한 대사물질의 개요를 숙지하고 획득된 그래프의 형태를 잘 파악하여 잔존 대사물질를 최소화 하여야 한다.

APPLICATION OF TIME-OF-FLIGHT NEAR INFRARED SPECTROSCOPY TO WOOD

  • Tsuchikawa, Satoru;Tsutsumi, Shigeaki
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1182-1182
    • /
    • 2001
  • In this study, the newly constructed optical measurement system, which was mainly composed of a parametric tunable laser and a near infrared photoelectric multiplier, was introduced to clarify the optical characteristics of wood as discontinuous body with anisotropic cellular structure from the viewpoint of the time-of-flight near infrared spectroscopy (TOF-NIRS). The combined effects of the cellular structure of wood sample, the wavelength of the laser beam λ, and the detection position of transmitted light on the time resolved profiles were investigated in detail. The variation of the attenuance of peak maxima At, the time delay of peak maxima Δt and the variation of full width at half maximum Δw were strongly dependent on the feature of cellular structure of a sample and the wavelength of the laser beam. The substantial optical path length became about 30 to 35 times as long as sample thickness except the absorption band of water. Δt ${\times}$ Δw representing the light scattering condition increased exponentially with the sample thickness or the distance between the irradiation point and the end of sample. Around the λ=900-950 nm, there may be considerable light scattering in the lumen of tracheid, which is multiple specular reflection and easy to propagate along the length of wood fiber. Such tendency was remarkable for soft wood with the aggregate of thin layers of cell walls. When we apply TOF-NIRS to the cellular structural materials like wood, it is very important to give attention to the difference in the light scattering within cell wall and the multiple specular-like reflections between cell walls. We tried to express the characteristics of the time resolved profile on the basis of the optical parameters for light propagation determined by the previous studies, which were absorption coefficient K and scattering coefficient S from Kubelka-Munk theory and n from nth power cosine model of radiant intensity. The wavelength dependency of the product of K/S and n, which expressed the light-absorbing and -scattering condition and the degree of anisotropy, respectively, was similar to that of the time delay of peak maxima Δt. The variation of the time resolved profile is governed by the combination of these parameters. So, we can easily find the set of parameters for light propagation synthetically from Δt.

  • PDF

Magnetic Resonance Findings in Two Episodes of Repeated Cerebral Fat Embolisms in a Patient with Autologous Fat Injection into the Face

  • Lee, Kyung-Mi;Kim, Eui-Jong;Jahng, Geon-Ho;Chang, Dae-Il
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권5호
    • /
    • pp.312-315
    • /
    • 2012
  • We report magnetic resonance image (MRI) and magnetic resonance spectroscopy (MRS) findings in a patient of cerebral fat embolism (CFE) occurred in a 26-year-old woman after an autologous fat injection into the face. After initial neurologic symptom onset, MRI and MRS data were obtained two times to investigate repeated CFE. We obtained the MRS data in the two different time intervals and two different echo times to compare the lesions with normal brain parenchyma. The results of MRS data showed that a decrease in N-acetyl-aspartate, an increase in lactate and a very high early peak of free lipids between 0.9 and 1.4 ppm were obtained at the acute infarcted lesion as compared with normal brain parenchyma. In addition, these findings were more clearly detected on short echo time spectrum rather than long spectrum. A close relationship between the clinical manifestations and MRI and MRS findings of the brain can helpful to distinguish CFE with other conditions and to evaluate the cause materials of infarctions rather than conventional MRI or diffusion-weighted imaging.

High Crystalline Epitaxial Bi2Se3 Film on Metal and Semiconductor Substrates

  • 전정흠;장원준;윤종건;강세종
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제41회 하계 정기 학술대회 초록집
    • /
    • pp.302-302
    • /
    • 2011
  • The binary chalcogenide semiconductor Bi2Se3 is at the center of intensive research on a new state of matter known as topological insulators. It has Dirac point in their band structures with robust surface states that are protected against external perturbations by strong spin-orbit coupling with broken inversion symmetry. Such unique band configurations were confirmed by recent angle-resolved photoelectron emission spectroscopy experiments with an unwanted n-type doping effect, showing a Fermi level shift of about 0.3 eV caused by atomic defects such as Se vacancies. Since the number of defects can be reduced using the molecular beam epitaxy (MBE) method. We have prepared the Bi2Se3 film on noble metal Au(111) and semiconductor Si(111) substrates by MBE method. To characterize the film, we have introduced several surface sensitive techniques including x-ray photoemission electron spectroscopy (XPS) and micro Raman spectroscopy. Also, crystallinity of the film has been confirmed by x-ray diffraction (XRD). Using home-built scanning tunneling microscope, we observed the atomic structure of quintuple layered Bi2Se3 film on Au(111).

  • PDF