• Title/Summary/Keyword: Pohang ozone

Search Result 28, Processing Time 0.022 seconds

Numerical Study on the Ozone Formation Sensitivity of Precursors Using Adjoint Model around the South-eastern Area of the Korean Peninsula (수반모형을 이용한 한반도 남동지역의 오존 전구물질의 오존 생성 민감도에 관한 수치연구)

  • Park, Soon-Young;Lee, Soon-Hwan;Lee, Hwa Woon;Kim, Dong-Hyeok
    • Journal of the Korean earth science society
    • /
    • v.34 no.7
    • /
    • pp.669-680
    • /
    • 2013
  • Ozone sensitivity analysis with respect to $NO_x$ is conducted around the south-eastern area of the Korean Peninsula. WRF-CMAQ modeling system is used to simulate a local circulation and high ozone episode day. To analyze the sensitivity, the adjoint model for CMAQ is adopted in this study. The purpose of current study is to investigate the location that affects a day time ozone concentration of these receptors on the high ozone episode day. Adjoint sensitivity analysis for Daegu shows two areas of influence. One is the range from the neighboring location to Pohang and it affects mainly on the same day as receptor time. The other is the remote south-eastern area from Daegu. This remote influence area suggests that $NO_x$ emitted on the previous day can change the ozone concentration at receptor time. The influence area for Busan, on the other hand, is originated only from the emission on the previous day because the sea-breeze occurred on the episode day makes low influence of surrounding emission. The cross sectional analysis reveals that $NO_x$ advection is important not only near the surface of land but also around the height of boundary layer.

The Charecteristics of Superposed Discharge Type Ozonizing System Considering the Change of Temperature of. the Supplied Gas (원료가스의 온도변화를 고려한 중첩방전형 오존발생장치의 특성)

  • Lee, Sang-Keun;Song, Hyun-Jig;Chun, Byung-Joon;Kim, Yeong-Hun;Kim, Sang-Gu;Park, Won-Zoo;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1705-1707
    • /
    • 1998
  • In this paper, a superposed discharge type ozonizer was designed and manufactured. The ozonizer is equipped with three electrodes : central electrode, internal electrode and external electrode, and it consists of two gaps. The ozone is generated by superposing silent discharge, which are respectively generated betweens two gaps. This paper describes the following two characteristics : (1) 'the characteristics of discharge with variation with output voltage of AC High Voltage source, quantity of the supplied gas and discharge voltage (2) the characteristics of ozone discharge power, temperature of the supplied gas.

  • PDF

The Investigation and Comparison of Characteristics of Air Pollution for Cohort Study in Chungju with Industrial Cities (대조코호트 연구를 위한 충주의 대기오염현황 조사와 산단지역과의 비교)

  • Kim, Jae-Hoon;Wee, Seong-Seung;Nam, Sang-Hoon;An, Jung-Sun;Kim, Dae-Sun
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.1
    • /
    • pp.1-11
    • /
    • 2008
  • The purpose of this study was to investigate air quality in Chungju, Korea, using data obtained with a local air quality monitoring system. We have utilised cohort studies to investigate the relations between environmental pollution and the health of residents near large industrial complexes since 2004. This study analyzes the $O_3,\;NO_2,\;SO_2,\;CO\;and\;PM_{10}$ concentration in Chungju from 2002 to 2006. Air pollutants are closely related to the number of manufacturing facilities and cars, energy utilization and weather conditions. Generally, the diurnal concentration of air pollutants in Chungju reached the highest level in the morning (about$08:00{\sim}$) and early evening (about$19:00{\sim}$). On the other hand, the diurnal concentration of ozone as recorded gives the highest amount in late afternoon (about$16:00{\sim}$) and lowest in early morning (about$08:00{\sim}$). The concentration of air pollutants in Chungju was highest from winter to spring and lowest during the summer season. On the other hand, the monthly variation of ozone concentration was greatest in June and smallest in December. Also the, $PM_{10}$ concentration posted the highest record in April and the lowest during September. In general, this study analyzed air pollution changes in Chungju as well as in large scale industrial complex regions within Korea such as Ulsan, Pohang, Kwangyang, Sihwa Panwol and Gangneung in Korea. We compared the air quality of Chungju with those of these cites and found that air pollutants except for CO in Chungju was generally lower than large industrial complex regions.

Estimation of dose rate using radiative transfer equations (복사전달방정식을 이용한 조사율 추정)

  • 문윤섭;김유근;이영미
    • Journal of Environmental Science International
    • /
    • v.11 no.12
    • /
    • pp.1195-1204
    • /
    • 2002
  • We calculated dose rate using radiative transfer equations to consider radiative processes distinctly. The dose rate at Pohang(36°02'N, 129°23'E) was calculated using measured ozone and meteorological data and two-stream approximations(quadrature, Eddington, delta Eddington, PIFM(practical improved flux method), discrete ordinate, delta discrete ordinate) are used in solving equation. The purpose of this study is to determine the most compatible radiative transfer approximation for simulating the radiative and photochemical processes of atmosphere through comparision between calculated and measured values. Dose rate of the biologically effective irradiance in the region 0.28-0.32 U m showed the highest value when quadrature and Eddington was used and lower value on condition that delta scaling was applied. Correlation coefficient between dose rate at surface using radiation transfer equation and measured UV-B at Pohang was 0.78, 0.79 and 0.81 when delta Eddington, PIFM and delta discrete ordinate were used. Also, in case of above approximations were used, MBE(Mean Bias Error) was within -0.3MED/30min and RMBE(Relative Mean Bias Error) was below 10% between 1200 LST and 1400 LST Approximations which are compatible in estimating radiative process are delta Eddington, PIFM and delta discrete ordinate. Especially, in case that radiative process is considered more detail, delta discrete ordinate increased the number of stream is proper.

Intercomparisons of ADEOS/IMG Measurements with the Sonde Observations over Korea (한반도 상공의 ADEOS/IMG 관측 자료와 존데 자료의 비교 분석)

  • 조하만;김주공;오성남
    • Korean Journal of Remote Sensing
    • /
    • v.15 no.3
    • /
    • pp.253-266
    • /
    • 1999
  • ADEOS(Advanced Earth Observing Satellite)/IMG(Interferometric Monitor for Greenhouse Gases) measurements - temperature, water vapor($H_2O$), ozone($O_3$) have been compared with the radio sonde and ozone sonde observations at Osan and Pohang stations for the 4 cases on 10 Jan.(a), 28 Jan.(b), 2 Apr.(c), and 19 Jun.(d) 1997 to detect the error ranges of the IMG data. It showed that the IMG data of the cases (b), (d) when the ADEOS passed over the central part of Korea were quite stable with the good agreement with the sonde observations, however, that of (a),(c) when the ADEOS passed over south- east coastal area were unstable with the larger differences from the sonde-observations. The RMSE and bias analyses of temperature for the stable cases (b),(d) showed that the differences between the IMG data and the sonde observations were about 1~4 K at the 700~300 hPa level and about 4~5 K or more at the higher level, and the IMG measurements tended to be larger than the sonde observations at the higher level above 200 hPa, while no typical bias was seen at the lower level. The RMSE and bias analysis for the version of level 2 5_6_4_4 of ozone showed that the RMSE of ozone were quite small, in general, except at the higher level above 50~60 hPa in the all 4 cases, however the bias was generally big with the positive value in the troposphere and the negative in the stratosphere. An example of vertical profile of trace gases such as $CO_2, N_2O, CH_4, HNO_3$, CO measured by IMG was also presented and it showed that the IMG data had large differences between the 5 different observation points.

Temporal and Spatial Pollution Characteristics of Ambient Criteria Pollutants in Metropolitan and Industrial Cities of Daegu-Gyeongbuk Area (대구-경북지역 광역대도시와 산업도시 환경기준 대기오염물질의 시간적 및 공간적 오염도 특성)

  • Lee, Hyun-Cheol;Jo, Wan-Kuen;Kim, Jong-Tae
    • Environmental Analysis Health and Toxicology
    • /
    • v.22 no.4
    • /
    • pp.329-337
    • /
    • 2007
  • This study considers the characteristics of nitrogen dioxide ($NO_2$), ozone ($NO_3$) and sulfur dioxide ($SO_2$) in three cities of Daegu-Gyeongbuk Area (Daegu, Pohang, and Gumi), which have different city or industrial characteristics, over a time period of 2 years. The diurnal, weekly, monthly and seasonal concentration variations of criteria air pollutants were attributed to compounds or city types. However, the seasonal variations of $O_3$ concentrations were dependent on compounds, but not on city types. Lower $O_3$ concentrations were observed in July when comparing with other summer months. For $SO_2$ and $NO_2$, the concentrations were higher in Daegu when compared to Pohang and Gumi, while the concentrations of $O_3$ were higher in Pohang and Gumi. $SO_2$ exhibited higher levels in the morning hours, while $O_3\;and\;NO_2$ exhibited higher levels in the afternoon hours for all cities. For $O_3$, the concentrations observed during Sunday were higher than those of other week or weekend days. Furthermore, the monthly and seasonal concentration variations of air pollutants depended on compounds or city types. It if noteworthy that the current monthly and seasonal variations were consistent with several prey ious studies.

The Characteristics of Showering Discharge Type Ozonizer (Showering Discharge형 오존발생장치의 특성)

  • Kim, Keum-Yeung;Mun, Kyung-Su;Song, Hyun-Jig;Lee, Kwang-Sik;Lee, Dong-In;Jeon, Young-Ju
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2248-2250
    • /
    • 1999
  • In this paper, showering discharge type ozonizer has been designed and manufactured. The ozonizer is equipped with three electrodes(central electrode of screw shape, internal electrode and external electrode) of cylinder shape. This paper describes the following two characteristics: (1) The characteristics of discharge with variation of output voltage of AC H.V source, flux of oxygen supplied gas and discharge voltage. (2) The characteristics of ozone generation by varying flux and discharge power.

  • PDF

Quality Characteristics of Sliced Raw-fish Washed by Different Methods during Storage (세척방법에 따른 생선회의 저장 중 품질특성)

  • Oh, Seung-Hee;Jung, Yoo-Kyung;Kim, Su-Hyun;Kim, Soon-Dong
    • Food Science and Preservation
    • /
    • v.14 no.6
    • /
    • pp.571-577
    • /
    • 2007
  • Storage characteristics of fresh and thawed sliced raw fish (flounder and rockfish) washed in different solutions (tap water, A; jade water, B; 0.2% chitosan-ascorbate (CA), C; 0.03 ppm ozone water, D; 1.5% vinegar containing jade water, E; 1.5% vinegar and 0.2% CA containing jade water, F) at $10^{\circ}C$ were investigated. Changes in pH and acidity of thawed sliced raw fish (TS) during storage were lower than for fresh sliced raw fish (DS). The total microbial content (log cfu/g) of A stored for 3 days in DS was 6.7 (which represented an increase of 1 log cycle compared with day zero), but was 5.50 in B, 3.23 in C, 4.90 in D, 2.40 in E and 1.77 in F, the latter similar to counts at day zero. The degree of microbial contamination of DS and TS followed the order F > E > D > C > B > A in flounder, and F > E > C > D > B > A in rockfish. In general the hardness and chewiness of TS was less than for DS. While the effect of CA on TS texture was not significant in flounder, the effect showed in rockfish. For DS, the appearance in B, C and D was relatively good, as was freshness. Fishiness of flavor was in the order A > B > F > E > D > C. Overall acceptability of flounder and rockfish treated with C was better than treatment with the other washing agents. For TS the appearance of flounder and rockfish were good in B and C. The freshness of flounder and rockfish were in the order of D > C > B > A > E > F and D > C > B > A > E > F, respectively. Fishiness of the flavor of sliced raw fish was lowest in D, which also provided the best overall acceptability.