• Title/Summary/Keyword: Pneumatic Test

Search Result 206, Processing Time 0.029 seconds

Life Prediction of Elastomeric U Seals in Hydraulic/Pneumatic Actuators Using NSWC Handbook (NSWC를 활용한 유공압 액추에이터 U 형 씰의 수명예측)

  • Shin, Jung Hun;Chang, Mu Seong;Kim, Sung Hyun;Jung, Dong Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.12
    • /
    • pp.1379-1385
    • /
    • 2014
  • Even the rough prediction of the product test time before the lifetime test of mechanical component begins would be of use in estimating cost and deciding how to keep up with the test. The reliability predictions of mechanical components are difficult because failure or degradation mechanisms are complicated, and few plausible databases are available for lifetime prediction. Therefore, this study conducted lifetime predictions of elastomeric U seals that were respectively installed in a hydraulic actuator and a pneumatic actuator using lifetime models and a field database based on failure physics and an actual test database obtained from the NSWC handbook. To validate the results, the predicted failure rates were compared with the actual lifetime test results acquired in the lab durability tests. Finally, this study discussed an engineering procedure to determine the coefficients in the failure rate models and analyzed the sensitivity of each influential parameter on the seal lifetime.

Development of Ankle Power Assistive Robot using Pneumatic Muscle (공압근육을 사용한 발목근력보조로봇의 개발)

  • Kim, Chang-Soon;Kim, Jung-Yup
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.8
    • /
    • pp.771-782
    • /
    • 2017
  • This paper describes the development of a wearable robot to assist ankle power for the elderly. Previously developed wearable robots have generally used motors and gears to assist muscle power during walking. However, the combination of motor and reduction gear is heavy and has limitations on the simultaneous control of stiffness and torque due to the friction of the gear reducer unlike human muscles. Therefore, in this study, Mckibben pneumatic muscle, which is lighter, safer, and more powerful than an electric motor with gear, was used to assist ankle joint. Antagonistic actuation using a pair of pneumatic muscles assisted the power of the soleus muscles and tibialis anterior muscles used for the pitching motion of the ankle joint, and the model parameters of the antagonistic actuator were experimentally derived using a muscle test platform. To recognize the wearer's walking intention, foot load and ankle torque were calculated by measuring the pressure and the center of pressure of the foot using force and linear displacement sensors, and the stiffness and the torque of the pneumatic muscle joint were then controlled by the calculated ankle torque and foot load. Finally, the performance of the developed ankle power assistive robot was experimentally verified by measuring EMG signals during walking experiments on a treadmill.

Development of ABS ECU for a Bus using Hardware In-the-Loop Simulation

  • Lee, K.C.;Jeon, J.W.;Nam, T.K.;Hwang, D.H.;Kim, Y.J.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1714-1719
    • /
    • 2003
  • Antilock Brake System (ABS) is indispensable safety equipment for vehicles today. In order to develop new ABS ECU suitable for pneumatic brake system of a bus, a Hardware In-the-Loop Simulation (HILS) System was developed. In this HILS, the pneumatic brake system of a bus and antilock brake component were used as hardware. For the computer simulation, the 14-Degree of Freedom (DOF) bus dynamic model was constructed using the Matlab/Simulink software package. This model was compiled and downloaded in the simulation board, where the Power PC processor was used for real-time simulation. Additional commercial package, the ControlDesk was used to monitor the dynamic simulation results and physical signal values. This paper will focus on the procedure and results of evaluating the ECU in the HILS simulation. Two representative cases, wet basalt road and $split-{\mu}$ road, were used to simulate real road conditions. At each simulated road, the vehicle was driven and stopped under the help of the developed ECU. In each simulation, the dynamical behavior of the vehicle was monitored. After enough tests in the laboratory using HILS, the parameter-tuned ECU was equipped in a real bus, which was driven and stopped in the real test field in Korea. And finally, the experiment results of ABS equipped vehicle's dynamic behavior both in HILS test and in test fields were compared.

  • PDF

Analysis of pneumatic braking component effects and characteristics of a diesel electric locomotive (디젤전기기관차의 공압제동 영향인자 및 특성 분석)

  • Choi, Don Bum;Kim, Min-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.541-549
    • /
    • 2018
  • This paper deals with the braking dynamic behavior of diesel electric locomotive pulling domestic cargo and passenger vehicles. Friction coefficient, pneumatic pressure, and running resistance affecting the braking system were tested. For the friction coefficient, the Dynamo test was performed with reference to UIC 541-4. The results are analyzed by multivariate regression and the relationship between braking force and ititial velocity is presented. The pneumatic pressure were classified into service braking and emergency braking. In order to reflect the characteristics of the brake valve and piping, the pressure rising over time was measured in the vehicle. In order to reflect the external force acting on the vehicle, we carried out the test of EN 14067-4 and presented the second order polynomial formula on a running resistance. The running resistance test results were compared with other countries. The dynamic behavior of a diesel electric locomotive running on a straight flat track based on vehicle resources, friction coefficient, braking pressure, and running resistance is simulated using the time integration presented in EN 14531-1. The simulation results were compared and verified with the vehicle braking test results. The results of this study can be used to analyze the dynamic braking behavior of a train. Also, it is expected that various parameters affecting braking in vehicle design can be analyzed and used as basic data for braking performance improvement.

Adaptation and Effects of the Evidence-based IPC Nursing Protocol on Prevention of Postoperative Venous Thromboembolism (외과적 수술 후 정맥혈전색전증 예방을 위한 근거기반 IPC(Intermittent Pneumatic Compression) 간호프로토콜의 수용개작 및 효과)

  • Kim, Nam Yong;Kim, Eun A;Sim, Jae Yeun;Jung, Soon Hee;Kim, Hye Young;Jang, Eun Hee;Shin, Jee Hye
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.23 no.1
    • /
    • pp.63-75
    • /
    • 2017
  • Purpose: This study was conducted to adapt the standardized evidence-based nursing protocol using the IPC (intermittent pneumatic compression) intervention to prevent venous thromboembolism in surgical patients. Further, an investigation was done to measure knowledge on prevention of venous thromboembolism, surrogate incidence of venous thromboembolism and to assess IPC compliance in the study patients compared with those in surgical patients who underwent IPC intervention due to previous clinical experience. Methods: An analysis was done of the nine modules suggested by National Evidence-based Healthcare Collaborating Agency (NECA) in the adaptation manual of the clinical practice guideline for protocol adaptation. A nonequivalent control group post test design as a quasi-experiment was used to verify the effect of the IPC protocol. Results: There was a significant difference in knowledge of prevention of venous thromboembolism, IPC application time after intervention and the number of IPC applications between the experimental group (n=50) using the IPC nursing protocol and the control group (n=49). However, the symptoms of deep vein thrombosis and pulmonary thromboembolism were not observed in either the experimental group or the control group after the intervention. Conclusion: Results confirm that the standardized IPC nursing protocol provides effective intervention to prevent venous thromboembolism in surgical patients.

CHARACTERISTICS OF THE PNEUMATIC TRANSFER SYSTEM AND THE IRRADIATION HOLE AT THE HANARO RESEARCH REACTOR

  • Chung, Yong-Sam;Kim, Sun-Ha;Moon, Jong-Hwa;Kim, Hark-Rho;Kim, Young-Jin
    • Nuclear Engineering and Technology
    • /
    • v.38 no.6
    • /
    • pp.585-590
    • /
    • 2006
  • This paper describes the results of an irradiation test and the specifications of the pneumatic transfer system (PTS) in the NAA #3 irradiation hole at the HANARO research reactor, which was reinstalled after some modifications of the operation mode at the end of 2004. The outer and inner diameters of the PE transfer tube are 34.1 and 27.5 mm, respectively. PE rabbit was used for sample irradiation. The $N_2$ gas pressure of the PTS lines was adjusted to 0.75 bar. The average sending time to the reactor was $8.5{\pm}0.3$ s and the average receiving time back to the receiver was $3.2{\pm}0.2$ s. The internal and external temperature of the irradiation tube was measured in a range of 50 to $80^{\circ}C$ for a 40 s to 80 s irradiation time, respectively. The optimum irradiation time was estimated to be less than 80 s. The thermal, epithermal and fast neutron flux at 30 MW thermal power were $1.42{\pm}0.01{\times}10^{14},\;1.51{\pm}0.04{\times}10^{13}$ and $9.48{\pm}0.69{\times}10^{11} n{\cdot}cm^{-2}{\codt}s^{1-}$, respectively. The cadmium ratio was approximately 9.40. The data obtained will be applied to supplement user information and for reactor management.

Development of Knee Ankle Foot Orthosis for Gait Rehabilitation Training using Plantaflexion and Knee Extension Torque (족저굴곡과 무릎 신전 토크를 이용한 보행 재활 훈련용 장하지 보조기 개발)

  • Kim, Kyung;Kim, Jae-Jun;Heo, Min;Jeong, Gu-Young;Ko, Myoung-Hwan;Kwon, Tae-Kyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.10
    • /
    • pp.948-956
    • /
    • 2010
  • The purpose of this study was to test the effectiveness of a prototype KAFO (Knee-Ankle-Foot Orthosis) powered by two artificial pneumatic muscles during walking. We had previously built powered AFO (Ankle-Foot Orthosis) and KO (Knee Orthosis) and used it effectively in studies on assistance of plantaflexion and knee extension motion. Extending the previous study to a KAFO presented additional challenges related to the assistance of gait motion for rehabilitation training. Five healthy males were performed gait motion on treadmill wearing KAFO equipped with artificial pneumatic muscles to power ankle plantaflexion and knee extension. Subjects walked on treadmill at 1.5 km/h under four conditions without extensive practice: 1) without wearing KAFO, 2) wearing KAFO with artificial muscles turned off, 3) wearing KAFO powered only in plantaflexion under feedforward control, and 4) wearing KAFO powered both in plantaflexion and knee extension under feedforward control. We collected surface electromyography, foot pressure and kinematics of ankle and knee joint. The experimental result showed that a muscular strength of wearing KAFO powered plnatarfexion and knee extension under feedforward control was measured to be lower due to pneumatic assistance and foot pressure of wearing KAFO powered plnatarfexion and knee extension under feedforward control was measured to be greater due to power assistance. In the result of motion analysis, the ankle angle of powered KAFO in terminal stance phase was found a peak value toward plantaflexion and there were difference of maximum knee flexion range among condition 2, 3 and 4 in mid-swing phase. The current orthosis design provided plantaflexion torque of ankle jonit in terminal stance phase and knee extension torque of knee joint in mid-swing phase.

Intermittent Strip Stock Advancing Accuracy Analysis of a Prototype Pneumatic Cylinder Driven Roll Feeder (공압실린더를 활용한 롤 피더의 간헐적 스트립 스톡 진행 정밀도 분석)

  • So, Jung-Duck;Kwon, Soon-Hong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.3
    • /
    • pp.353-358
    • /
    • 2010
  • This research introduces a new and improved design for a pneumatic cylinder driven roll feeder wherein each of the principal rotating feeder parts is configured so as to have feeding accuracy and to be low manufacturing cost. The feed pitch accuracy of the proposed roll feeder was evaluated by measuring lengths of cut offs of the strip stock with a shear attached to an air press. The air press was designed, manufactured, and mounted on the same table of the proposed roll feeder such that the strip stock maintained horizontal plane until the strip stock entered into the shear. The proposed roll feeder and the air press were designed to be operated automatically by a PLC employed controller. The feed pitch accuracy of the proposed roll feeder was analyzed by setting the pitch as 10, 12.5, and 15mm. At each predetermined feed pitch, the proposed roll feeder was tested 300 times as one test set and replicated three times. The average lengths of the cut offs of the strip stock ranged from 9.98 to 10.13mm, from 12.42 to 12.57mm, and from 14.96 to 15.06mm at the predetermined 10, 12.5, and 15mm feed pitch, respectively, among the total of 900 samples of each feed pitch. Main cause of variation of the length of the cut off of the strip stock fed by the proposed roll feeder was considered to be fluctuation of the air press during recompressing period of the air compressor to pressurize the air in the air tank. The largest difference between the maximum and the minimum length of the cut off was appeared while the air compressor recompressing the air. The air compressor used for this study restricted the air delivered to the proposed roll feeder while it was still running. Thus, this air delivery restriction problem should be improved by stabilizing the air press while the proposed roll feeder is running.

Sensory Evaluation of Friction and Viscosity Rendering with a Wearable 4 Degrees of Freedom Force Feedback Device Composed of Pneumatic Artificial Muscles and Magnetorheological Fluid Clutches

  • Okui, Manabu;Tanaka, Toshinari;Onozuka, Yuki;Nakamura, Taro
    • Journal of Drive and Control
    • /
    • v.18 no.4
    • /
    • pp.77-83
    • /
    • 2021
  • With the progress in virtual reality technology, various virtual objects can be displayed using head-mounted displays (HMD). However, force feedback sensations such as pushing against a virtual object are not possible with an HMD only. Focusing on force feedback, desktop-type devices are generally used, but the user cannot move in a virtual space because such devices are fixed on a desk. With a wearable force feedback device, users can move around while experiencing force feedback. Therefore, the authors have developed a wearable force feedback device using a magnetorheological fluid clutch and pneumatic rubber artificial muscle, aiming at presenting the elasticity, friction, and viscosity of an object. To date, we have developed a wearable four-degree-of-freedom (4-DOF) force feedback device and have quantitatively evaluated that it can present commanded elastic, frictional, and viscous forces to the end effector. However, sensory evaluation with a human has not been performed. In this paper, therefore, we conduct a sensory evaluation of the proposed method. In the experiment, frictional and viscous forces are rendered in a virtual space using a 4-DOF force feedback device. Subjects are asked to answer questions on a 1- to 7-point scale, from 1 (not at all) to 4 (neither) to 7 (strongly). The Wilcoxon signed rank test was used for all data, and answer 4 (neither) was used as compared standard data. The experimental results confirmed that the user could feel the presence or absence of viscous and frictional forces. However, the magnitude of those forces was not sensed correctly.

Development of Friction Welding Process of Zr-based Bulk Metallic Glasses (Zr-기 벌크 금속 유리의 마찰 접합 공정 개발)

  • Shin, Hyung-Seop;Jeong, Young-Jin;Kim, Ki-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.337-341
    • /
    • 2004
  • Bulk metallic glasses(BMG) with good mechanical properties have problems that engineering application fields have been limited because of limitation of the alloy size. In order to solving this problem, the friction welding of BMG has been tried using the superplastic-like deformation behavior under the supercooled liquid region. The apparatus for friction welding test was designed and constructed using pneumatic cylinder and gripper based on a conventional lathe. Friction welding have been tried to combination of same BMG alloy and crystalline alloys. The results of welding test were evaluated by X-ray diffraction, measurement of hardness and mechanical properties test. In order to obtain the optimized welding test conditions the temperature of friction interface was measured using Infrared thermal imager.

  • PDF