Life Prediction of Elastomeric U Seals in Hydraulic/Pneumatic Actuators Using NSWC Handbook |
Shin, Jung Hun
(Medical Device Development Center, Daegu-Gyeongbuk Medical Innovation Foundation)
Chang, Mu Seong (Reliability Assessment Center, Korea Institute of Machinery & Materials) Kim, Sung Hyun (Reliability Assessment Center, Korea Institute of Machinery & Materials) Jung, Dong Soo (Reliability Assessment Center, Korea Institute of Machinery & Materials) |
1 | MIL-HDBK-217F, 1995, Reliability Prediction of Electronic Equipment, Department of Defense. |
2 | EPRD-97, 1997, Electronic Parts Reliability Data-97, Reliability Information Analysis Center, Utica. |
3 | NPRD-2011, 2011, Non-Electronic Parts Reliability Data-2011, Reliability Information Analysis Center, Utica. |
4 | OREDA-2009, 2009, Offshore Reliability Data Handbook, Det Norske Veritas, Hovik. |
5 | NSWC-2011, 2011, Handbook of Reliability Prediction Procedures for Mechanical Equipment, Naval Surface Warfare Center Carderock Division, Maryland. |
6 | RS B 0099, 2009, Hydraulic Cylinder for Excavator, Korean Agency for Technology and Standards. |
7 | Jeong, D. U., Yun, H. S., Kwon, D. S., and Lee, S. H., 2011, "A Study on Method of Predicting Failure Rates of Fastening Parts," Journal of Applied Reliability, Vol. 11, No. 3, pp. 305-318. 과학기술학회마을 |
8 | ISO 19973-3, 2007, Pneumatic Fluid Power-Assessment of Component Reliability by Testing Part 3: Cylinders with Piston Rod, International Standard Organization. |
9 | JIS B 8367, 1999, Hydraulic Cylinder, Japanese Standards Association. |
10 | Kang, B. S. and Lee, Y. B., 2010, "Reliability Evaluation Technology for Pneumatic Cylinder," Journal of The Korean Society for Fluid Power & Construction Equipments, Vol. 7, No. 1, pp. 27-32. 과학기술학회마을 |