• 제목/요약/키워드: Plug-flow system

검색결과 63건 처리시간 0.022초

효과적 공간활용을 위한 Side Stream Plug-Flow Reactor를 이용한 하수 고도처리 공정 적용에 관한 연구 (A study on Applicable to Advanced treatment of using Side Stream Plug-Flow Reactor)

  • 김삼주;현인환;독고석
    • 상하수도학회지
    • /
    • 제22권3호
    • /
    • pp.367-372
    • /
    • 2008
  • This study configured the conventional $A^2O$ (Anaerobic-Anoxic-Aerobic bioreactor) system which the fixed media immersed into the anoxic reactor(Named PFR system : Plug Flow Reactor) for evaluating the removal efficiency of nitrogen in the wastewater. The experimental equipment was a cylinder which was consist of 4 pleated PE Pipes(Length 330M, Diameter 100mm) including 2 rope shape media. As a result, the average effluent T-N removal efficiency of the conventional $A^2O$ system was 17.9, 40.3, 50.6, 44.6% in each mode, but the average effluent T-N removal efficiency of the PFR system could achieve 38.8, 57.1, 71.8, 65.4% in each mode. It indicated that the PFR system caused to the increasing of C/N ratio that effected to the increasing of the denitrification efficiency. Not only the effective T-N removal efficiency but also the controllable install space will give advantages for retrofitting of the wastewater treatment plant with the conventional treatment system to the PFR system.

기체상-생물막 여과 공법의 BTX 제거 공정 해석을 위한 1차원 동적 수치모델 개발 (Development of an 1-Dimensional Dynamic Numerical Model for BTX Removal Process Analysis by Gaseous-Biofilm Filtration)

  • 김영관;최성찬;김석구;이용석
    • 대한환경공학회지
    • /
    • 제37권12호
    • /
    • pp.689-695
    • /
    • 2015
  • 부착성 미생물을 이용하여 기체상 오염물질을 여과 방식으로 처리하는 생물 공정은 기체상의 흐름 특성과 공정 인자간 관련성이 매우 복잡하게 작용하는 특징을 가진다. 본 연구는 기체상 공정의 특성으로 미세한 변화에도 반응이 급변하는 현상과 물질간 반응관계의 중요성을 고려하여 일반화된 plug flow계 반응조의 공정 분석 도구로 활용 가능한 1차원 동적 수치해석 모델을 개발하였다. 개발 모델은 물질수지 원리를 기초하여 확산을 단순화하고 물질간 경쟁, 상승, 억제 반응 등 상호 반응관계를 반영하여 구성이 용이하도록 하였다. 개발 모델의 적용성 평가는 저속과 고속으로 구분된 BTX 제거 실험에 대하여 보정과 검정 절차로 수행되었다. 개발 모델은 고속 조건의 toluene을 제외하고 모든 조건과 항목에서 상관계수($R^2$) 0.79 이상에서 실험 결과를 재현하였다. 개발 모델은 연속흐름(plug flow)계로써 기체상-생물막의 일반화된 공정에 적용할 수 있는 것으로 평가되었으며 복잡하고 다양한 공정 실험에서 설계 인자 분석 및 효율 평가에 유용한 도구로 사용될 수 있다.

저심도 도로터널에서 터널과 수직환기구의 단면적 비와 열방출률이 Plug-holing 현상에 미치는 영향에 관한 실험연구 (Experimental Study on the Effect of the Area Ratio between Shaft and Tunnel and Heat Release Rate on the Plug-holing Phenomena in Shallow Underground Tunnels)

  • 홍기배;나준영;유홍선
    • 한국산학기술학회논문지
    • /
    • 제20권4호
    • /
    • pp.619-625
    • /
    • 2019
  • 저심도 터널에서는 온도차에 의한 부력을 이용한 자연배기시스템이 많이 사용되고 있지만 이는 연기배출을 인위적으로 조절할 수 없다. 그러므로 자연배기시스템에서는 수직환기구에서 연기 배출량이 설계된 연기 배출량보다 적어지는 Plug-holing 현상을 고려한 설계가 필수적이다. Plug-holing 현상은 터널과 수직환기구의 형상 위치, 화원의 위치와 발열량 등에 영향을 받는다. 본 연구에서는 터널과 자연 환기구의 단면적 비와 화원의 열방출률이 자연배기시스템에서 발생하는 Plug-holing 현상에 미치는 영향에 대하여 실험적으로 분석하였다. 1/20 크기로 축소시킨 실험모델에서 터널과 수직환기구의 종횡비는 고정시키고 터널과 수직환기구의 단면적 비를 달리하여 Plug-holing 현상에 미치는 영향을 확인하였다. 화원의 열방출율은 0.55 kW, 0.98 kW, 1.67 kW로 고정시켰다. 실험결과, 연기 경계층온도와 수직환기구 내의 온도와의 비교를 통한 Plug-holing 발생을 판단하였고, 터널과 수직환기구의 단면적 비가 증가함에 따라서 수직환기구 하부의 유동과 온도분포 특성이 변함을 확인하였다. 터널 화재 시 Plug-holing 현상은 터널과 수직환기구의 단면적 비에 영향을 받으며 단면적 비가 클수록 Plug-holing 발생 가능성이 증가하였다.

회전식 화학증착 장치 내부의 유동해석을 통한 최적 유량 평가 (COMPUTATIONAL ASSESSEMENT OF OPTIMAL FLOW RATE FOR STABLE FLOW IN A VERTICAL ROTATING DISk CHEMICAL VAPOR DEPOSITION REACTOR)

  • 곽호상
    • 한국전산유체공학회지
    • /
    • 제17권1호
    • /
    • pp.86-93
    • /
    • 2012
  • A numerical investigation is conducted to search for the optimal flow rate for a rotating-disk chemical vapor decomposition reactor operating at a high temperature and a low pressure. The flow of a gas mixture supplied into the reactor is modeled by a laminar flow of an ideal gas obeying the kinetic theory. The axisymmetric two-dimensional flow in the reactor is simulated by employing a CFD package FLUENT. With operating pressure and temperature fixed, numerical computations are performed by varying rotation rate and flow rate. Examination of the structures of flow and thermal fields leads to a flow regime diagram illustrating that there are a stable plug-like flow regime and a few unfavorable flow regimes induced by mass unbalance or buoyancy. The criterion for sustaining a plug-like flow regime is discussed based on a theoretical scaling argument. Interpretation of the flow regime map suggests that a favorable flow is attainable with a minimum flow rate at the smallest rotation rate guaranteeing the dominance of rotation effects over buoyancy.

압축성 유체용 글로브 밸브의 유량특성 향상에 관한 연구 (A Study on the Improvement of Flow Characteristics of the Glove Valve for Compressible Fluid)

  • 배지원;정우영;장지성
    • 드라이브 ㆍ 컨트롤
    • /
    • 제16권4호
    • /
    • pp.32-37
    • /
    • 2019
  • Glove valves are used for various purposes in the process control field because such valves enable easy control of temperature and pressure. However, such valves are associated with significant loss of pressure and also have the disadvantage of complicating the shape of the cage or plug to facilitate linear flow rate change. In this paper, the shape of the plug, one of the valve flow control elements, was designed to improve the flow characteristics of the glove valve, and then CFD analysis was performed using compressible fluid. The numerical analysis results of the glove valve were analyzed according to the opening ratio and the pressure ratio of the valve. From these results, it was found that the proper notch on the side of the plug contributed to reducing the energy loss of the fluid through the valve and improving the linearity of the valve.

결빙 관막음시 배관내 유체 결빙현상의 실험적 연구 (An Experimental Study for the Liquid Freezing Phenomena in a Pipe During Ice Plugging)

  • 박영돈;조현철;최병익;김귀순
    • 대한기계학회논문집B
    • /
    • 제25권3호
    • /
    • pp.366-372
    • /
    • 2001
  • The ice plugging process consists of placing liquid nitrogen around a pipe and removing heat until the water in the pipe freezes and provides a solid plug or seal against fluid movement. This technique enables us to repair or inspect a pipe system without shutdown of entire system. A set of test apparatus for investigation of the liquid freezing phenomena during ice plugging is prepared. This study shows the characteristics of the liquid freezing and the heat transfer with various pipe and freezing jacket conditions. And in case there is flow of the fluid inside the pipe, the flow rate which can be able to form the ice plug is identified with the effect of the pipe diameter and freezing jacket length on the plug formation. The permissible maximum flow rate for the complete plug formation is approximately proportional to the freezing jacket length at the same pipe diameter condition.

공동현상 가시화 실험을 통한 절환밸브 바텀플러그 형상 최적화 (Cavitation Visualization Test for Shape Optimization of Bottom Plug in Reversing Valve)

  • 김태안;이명곤;한승호
    • 대한기계학회논문집A
    • /
    • 제40권11호
    • /
    • pp.913-918
    • /
    • 2016
  • 자동차 엔진과 변속기 블록 등의 가공과정에서 잔류하는 기름때를 제거하기 위한 부품 세척장비는 정교한 제어장치 없이도 정확한 수류방향 절환이 원활히 이루지는 3 방향 절환밸브를 사용한다. 그러나, 밸브의 복잡한 유로 및 바텀플러그 형상으로 인해 유속변화가 심하게 발생하여 공동현상이 나타날 수 있다. 본 연구에서는 3 방향 절환밸브 내의 유동특성을 해석적으로 평가하였으며, 바텀플러그 하부에서 나타나는 공동현상을 공동화지표와 POC(Percent of cavitation)를 도입하여 정량화하였다. 공동현상의 저감을 위해 바텀플러그 형상을 매개변수화하고, 해석의 수렴성 개선과 해석시간을 단축시킬 수 있는 단순 유한요소모델을 이용하여 유동해석을 통한 형상최적설계를 실시하였다. 또한, 연구팀에서 보유하고 있는 유동시험설비와 ISA-RP75.23 규격에 맞게 제작된 시편을 이용하여 공동현상 가시화 실험을 실시하여 해석결과를 검증하였다.

Numerical Analysis of Plume Characteristics and Liquid Circulation in Gas Injection Through a Porous Plug

  • Choi, Choeng-Ryul;Kim, Chang-Nyung
    • Journal of Mechanical Science and Technology
    • /
    • 제14권12호
    • /
    • pp.1365-1375
    • /
    • 2000
  • Two phase flows have been numerically calculated to analyze plume characteristics and liquid circulation in gas injection through a porous plug. The Eulerian approach has been for formulation of both the continuous and dispersed phases. The turbulence in the liquid phase has been modeled using the standard $textsc{k}$-$\varepsilon$ turbulence model. The interphase friction coefficient has been calculated using correlations available in the literature. The turbulent dispersion of the phase has been modeled by the "dispersion Prand시 number". The predicted mean flows is compared well with the experimental data. The plume region area and the axial velocities are increased with the gas flow rate and with the decrease in the inlet area. The turbulent intensity also shows the same trend. Also, the space-averaged turbulent kinetic energy for various gas flow rates and inlet areas has been obtained. The results are of interest in the design and operation of a wide variety of materials and chemical processing operations.

  • PDF

플러그묘 개체군의 순광합성속도 측정 (Measurement of Net Photosynthetic Rate in the Plug Stand)

  • 김용현;고재풍수
    • Journal of Biosystems Engineering
    • /
    • 제22권3호
    • /
    • pp.311-316
    • /
    • 1997
  • Two methods were used to detrermine the net photosynthetic rate(NPR) in the plug stand using a wind tunnel for plug seedlings Production. One is called as the integration method in which NPR calculated by the use of air current speed and $CO^2$ concentration measured at any heights above the medium surface in a wind tunnel were summed. It was assumed that the air flow at any layer did not mix with the lower or upper air layer. The other is called as the diffusion method in which eddy diffusivities above the plug stand were used to determine the NPR in the plug stand. In this method, $CO^2$ above or inside the plug stand was assumed to be absorbed vertically. NPR determined by the diffusion method was 28~45% of the NPR calculated by the integration method. Considering the magnitude of NPR and the effects of the air current speed on NPR, the integration method would be adequate for the calculation of NPR in the plug stand. Maximum NPR determined using the integration method appeared at the air current speed of 0.7m $s^{-1}$. It was ascribed to the decreased diffusion resistances of $CO^2$ with the increasing air current speed. NPR at the rear region in plug stand was 20~34% lower than that at the front region. NPR sharply decreased with the increase of an elapsed time after the beginning of photoperiod. Therefore $CO^2$ enrichment would be effective to force the growth of plug seedlings in a semi-closed ecological system under artificial lighting.

  • PDF

정적 연소실에서 성층화된 혼합기 조건하의 점화 전극사이 당량비 측정과 연소 특성에 미치는 영향 (Measurements of Equivalence Ratio in the Spark Plug Gap and Its-Effects on Combustion Under Stratified Mixture Conditions in a Constant Volume Chamber)

  • 배상수;이기철;민경덕
    • 대한기계학회논문집B
    • /
    • 제25권10호
    • /
    • pp.1311-1317
    • /
    • 2001
  • To investigate only the effects of the stratified mixture distribution on initial flame propagation and combustion characteristics, the instantaneous equivalence ratio in the spark plug gap and combustion pressure were measured simultaneously In a constant volume chamber, To induce the stratified propane-air mixture distribution near the spark plug, counter-flow typed mixture injection system was used under the constant mean equivalence ratio $\Phi$$\_$mean/= 1.0 The instantaneous equivalence ratio was measured by a single-shot Raman scattering with narrow-band KrF excimer laser. The measuring error was within the limit of $\pm$ 3.5% provided that the proposed method was applied to the measured Raman signals. Judging from mass fraction burned derived from the measured pressure, the optimum combustion characteristics were shown under the condition that the local equivalence ratio in the spark plug was near 1.28$\pm$0.04, and these characteristics were more remarkable at the initial stage of combustion.