• Title/Summary/Keyword: Plug-Sliding Door

Search Result 9, Processing Time 0.04 seconds

Development of a Sliding-Plug Entrance Door System for Urban Electric Transit Unit to Reduce Inside Noise Level (전동차 소음저감을 위한 슬라이딩플러그 출입문 개발)

  • 서승일;임영호;신동국
    • Journal of the Korean Society for Railway
    • /
    • v.5 no.2
    • /
    • pp.112-117
    • /
    • 2002
  • Reduction of noise level in the cabin of urban transit unit is an important issue to enhance the comfortability of passengers. It is made clear that a cause of increased noise level in cabin is the imperfect airtightness of entrance doors. In this study, the sliding-plug door system is developed to reduce the noise level of cabins by securing the airtightness of entrance door. The sliding-plug door system is composed of air-driven engine, swing arms, guide rails, guide rollers and locking devices. It is economical owing to using the previous door engine system. It is also adequate for the platform system of our subway station. It was tested to prove the reliability of system and was applied to standard urban transit unit. The effectiveness of noise reduction in cabin resulting form the sliding-plug door system was confirmed by test results.

Development for pneumatic plug door system (공기식 플러그도어 시스템 개발)

  • 홍재성;김연수;이호용;김원경;양우봉;신진호
    • Proceedings of the KSR Conference
    • /
    • 2001.05a
    • /
    • pp.162-169
    • /
    • 2001
  • There are many EMU lines in korea. But only one type has been applied to passenger side door. This type is so called "Pocket sliding type". This type has some week points. To begin with, it is not good for decreasing the noisy form the outside of carbody. And the second time, if some obstacles are put between sliding door, only driver can operate re-open door switch manually ill driver's cab. This type is so dangerous for passengers. So many people want to the new door type that have no defect. KRRI joined forces with ANT corporation for pneumatic plug door system. This type will be good for decreasing the noisy, passenger′s safe. The project was started at the last year on November and will be finished on June, this year In this paper, we will deal with the role of cylinder, planetary gear, door control unit, dynamic mechanism, and the report of FEM, type test. This paper will contribute to tile electric motor control plug door system.

  • PDF

A Study on Position Control Method of Electric Door of EMU (전기식 도어 위치제어방식 연구)

  • Joung, Eui-Jin;Won, Jong-Un;Kim, Gil-Dong;Lee, Han-Min;Lee, Chang-Mu;Hong, Jai-Sung
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.3086-3091
    • /
    • 2011
  • Many types of door system are used in the Electric Multiple Unit (EMU). The door system is categorized to the two types of door system, sliding door and plug door. The sliding door is widely used in the EMU but has weak point for the noise problem. The plug door has advantages for the noise reduction characteristic. Nowaday electric door system is widely used and motor is a main part of driving system in the door system. We have to know the exact driving position of door system to control proper operation of the door. Actually encoder or tachometer is used for the position controlling, but it makes price increase and failure increase. In this paper, we study and describe motor current calculation method to contol and know exact driving position of door system.

  • PDF

Functional Analysis of Subsystem for Electric Plug Door (전기식 플러그 도어 하부시스템 기능 분석)

  • Joung, Eui-Jin;Hong, Jai-Sung;Won, Jong-Un;Lee, Jang-Mu;Lee, Han-Min;Kim, Gil-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2198-2199
    • /
    • 2011
  • The sliding door and plug door are the main types of door system in the EMU(Electric Multiple Unit). The sliding door is widely used in Korea but has weak point in the noise problem. In the low operation speed, the noise coming from outer side of the EMU is not an important factor. As the speed is higher than before, noise is increased and make an issue. The main cause of noise is the imperfect air tightness in the EMU. The plug door system has advantages for the noise reduction characteristic in the high speed area. Actually the noise level is an important factor for the passenger comfort. In this paper, we will describe the characteristic of electric plug door and functions of sub component.

  • PDF

Development for Sliding Step for Next Generation Train (차세대 전동차를 위한 슬라이딩 스텝 개발)

  • Ha, Dong-Ki;Seo, Soo-Ho;Park, Hung-Soo;Yoo, Hyeun-Bae;Park, Sung-Hyuk;Son, In-Suk
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1584-1589
    • /
    • 2007
  • Plug-in type door is installed in recently designed tube. It is world wide trend to fulfill the customer's demand. But, plug-in door need widely gap between doorway and platform and it is raise an serious accident. Therefore, newly designed train must have safety device like a sliding step to prevent incident. This paper present about development process for sliding step. Trend of sliding step, development plan, course, technical description, and etc. will be included in this paper.

  • PDF

Complex Planetary Gear Train for a Plug type Passenger Door (복합유성기어장치를 적용한 플러그 방식 출입문의 변속장치)

  • 김연수;홍재성;박성혁;백남욱;이병송
    • Proceedings of the KSR Conference
    • /
    • 2001.05a
    • /
    • pp.170-177
    • /
    • 2001
  • Since plug type passenger door has two motion modes, power transmission unit must be capable of plug-in or plug-out, and sliding mode. Complex planetary gear train is proposed, which is composed of two 2K-H, I type planetary gear units. For the proposed complex planetary gear train, ranges of addendum modification coefficients which would not lead to interferences is analyzed, and optimal addendum modification coefficients among these ranges which generate the maximum efficiency are presented. Based on the interference, efficiency and torque ratio analysis results, complex planetary new train is designed and manufactured.

  • PDF

Development on a Transmission Unit for a Plug Type Passenger Door (플러그 방식 승객용 출입문의 변속장치 개발)

  • 김연수;홍재성;박성혁;이관섭;백영남
    • Journal of the Korean Society for Railway
    • /
    • v.4 no.2
    • /
    • pp.55-61
    • /
    • 2001
  • Since the plug type passenger door has two modes of motion, a power transmission unit must be capable of plug-in or plug-out mode, and sliding mode. Complex planetary gear train is proposed, which is composed of two 2K-H, I type planetary gear units. For the proposed complex planetary gear train, ranges of addendum modification coefficients which would not lead to interferences are analyzed, and optimal addendum modification coefficients among these ranges which generate the maximum efficiency are presented. Based on the results of analysis on interferences, efficiencies and torque ratios, the specifications for the complex planetary gear train were determined. It has been shown by tests of the complex planetary gear train manufactured that the gear train worked well with good agreements of analysis.

  • PDF

Development of Door Control Unit for the Electric Plug-in Door of Subway Train (전동차 전기식 플러그도어 출입문 제어 장치 개발)

  • Joung, Eui-Jin
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.4
    • /
    • pp.47-53
    • /
    • 2011
  • The Electric Multiple Unit (EMU) has many types of door system such as sliding door, plug door etc.al. according to customer's requirements. The sliding door is widely used in Korea but has weak point in the noise problem. In the low operation speed, the noise coming from outer side of the EMU is not an important factor. As the speed is higher than before, noise is increased and make a problem. The main cause of noise is the imperfect air tightness in the EMU. The plug door system has advantages for the noise reduction characteristic in the high speed area. We have been developing electric plug-in door. The door is controlled by Door Control Unit(DCU) following the order of Automatic Train Protection (ATP) that is a kind of train signalling system. DCU has to simultaneously open and close the doors and the operation of it is related to the passengers safety. So DCU is a safety device that is important to reliability and safety. DCU is composed of several devices of control, motor driving, Input/Output, communication and power. In this paper, we will describe the functions, characteristic, requirement, subsystem and test results of DCU used for the electric plug-in door.

Development of the Standardized Aluminum Electric Motor Car (표준화된 알루미늄 전동차의 개발)

  • 서승일;최성호;임영호;이정수
    • Journal of the Korean Society for Railway
    • /
    • v.2 no.3
    • /
    • pp.54-60
    • /
    • 1999
  • In this paper, design and construction process for the standardized electric motor car according to standard specification is described. Aluminum extrusion profiles and power and control system made domestically are used in the electric motor car. Also, plug-sliding door system for noise reduction and automatic train control system are developed and applied. Through the development of the electric motor car, most electric and control systems can be substituted by domestic standard systems, and safety and reliability of electric motor cars can be secured.

  • PDF