• Title/Summary/Keyword: Plating technique

Search Result 152, Processing Time 0.022 seconds

Fabrication of MDOF IPMC Actuators to Generate Undulatory Motion (파동형 움직임이 가능한 다자유 IPMC 구동기 제작)

  • Jeon, Jin-Han;Oh, Il-Kwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.119-123
    • /
    • 2006
  • The ionic-polymer-metal-composite actuators have the best merit for bio-mimetic locomotion because of their large bending performance. Especially, they have the advantage for mimicking a fish-like motion because IPMCs are useful to be actuated in water. So we have developed IPMC actuators with multiple electrodes for realization of biomimetic motion. Generally, the IPMC actuator has been fabricated in electroless plating technique, while it needs very long fabrication time and shows poor repeatability in the actuation performance owing to the variables in chemical fabrication process. Therefore, the novel fabrication methods were investigated by combining electroless plating and electroplating techniques capable of patterning precisely. On the whole, two different methods were compared and analyzed with similar thickness level of Platinum electrodes. Present results show that mixing chemical reduction and electroplating can be a promising candidate for electrode patterning.

  • PDF

Influence of Nickel Electroplating on Hydrogen Chloride Removal of Activated Carbon Fibers

  • Park, Soo-Jin;Jin, Sung-Yeol;Ryu, Seung-Kon
    • Carbon letters
    • /
    • v.5 no.4
    • /
    • pp.186-190
    • /
    • 2004
  • In this work, a nickel metal (Ni) electroplating on the activated carbon fiber (Ni/ACFs) surfaces was carried out to remove the toxic hydrogen chloride (HCl) gas. The surface properties of the treated ACFs were determined by using nitrogen adsorption isotherms at 77 K, SEM, and X-ray diffraction (XRD) measurements. HCl removal efficiency was confirmed by a gas-detecting tube technique. As a result, the nickel metal contents on the ACF surfaces were increased with increasing the plating time. And, it was found that the specific surface area or the micropore volume of the ACFs studied was slightly decreased as increasing the plating time. Whereas, it was revealed that the HCl removal efficiency containing nickel metal showed higher efficiency values than that of untreated ACFs. These results indicated that the presence of nickel metal on the ACF surfaces played an important role in improving the HCl removal over the Ni/ACFs, due to the catalytic reactions between nickel and chlorine.

  • PDF

Development and Tool Life Assessment of TiYN Coated High Speed Steel Tools (TiYN코팅 고속도강 공구의 개발 및 공구수명 평가)

  • 이영문;강태봉;최수준;송태성
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.8
    • /
    • pp.33-38
    • /
    • 1998
  • TiYN coated high speed steel tools have been developed and their tool lifes were assessed. First yttrium alloyed titanium target was manufactured, then using the arc ion plating(AIP) technique TiYN coating was deposited onto high speed steel substrate. Three kinds of varying thickness of TiYN coated tools were prepared. Cutting tests were carried out with theses tools and for comparison with the commercially available uncoated, TiN, TiCN and TiAlN coated tools. During the cutting tests flank wear width vs. cutting time was measured. It has been revealed that the newly developed TiYN coated tools show superior tool life characteristics to others.

  • PDF

Effect of Electrodeposition Condition on GMR Co/Cu Multilayers

  • Rheem, Young-Woo;Yoo, Bong-Young
    • Journal of Magnetics
    • /
    • v.12 no.3
    • /
    • pp.124-128
    • /
    • 2007
  • Co/Cu GMR multilayers were electrodeposited from various electrolytes using the dual bath technique to achieve high sensitive GMR multilayers. GMR ratio and sensitivity were strongly influenced by solution compositions and electrodeposition parameters where GMR and sensitivity of 12% and 0.052%/Oe were achieved from pyrophosphate baths. The effect of plating conditions on properties of Co/Cu multilayers may be attributed to crystallinity and grain size of deposits, and the ability of plating solutions to deposit contiguous films at lower nano thicknesses.

Microwave transmission characteristics of CPW traveling-wave electrode for light intensity modulator (광변조기용 CPW 진행파형 전극 마이크로파 전송특성)

  • 김성구;윤형도;윤대원;유용택
    • Electrical & Electronic Materials
    • /
    • v.9 no.1
    • /
    • pp.51-58
    • /
    • 1996
  • This report describes thick traveling-wave electrode formation and microwave transmission characteristics of the fabricated electrodes. Effective refractive indices of the microwave in the 5 micron CPW type traveling-wave electrodes is around 2.45 according to the results of time domain S parameter measurements. The bandwidth of the electrodes is about 10 GHz and could be extended to 15 GHz through optimization of the process. The developed process technique that enables plating of micropatterns upto 20 micron can be applied to broadband optical intensity modulators.

  • PDF

Gilt-bronze Standing Avalokiteshvara from Gyuam-ri, Buyeo: The Structure and Production Technique (부여 규암리 출토 금동관음보살 입상의 형상과 제작기법)

  • Shin, Yongbi;Kim, Jiho
    • Conservation Science in Museum
    • /
    • v.23
    • /
    • pp.1-16
    • /
    • 2020
  • In this paper, Gilt-bronze Standing Avaolkiteshvara (National Treasure No. 293, M355) excavated at Gyuam-ri in Buyeo was observed with a microscope to identify the production technique applied to it. It was also analyzed with XRF and hard X-ray to identify the composition and the surface treatment techniques and casting method applied. In this statue, Avalokiteshvara is standing upright on a lotus pedestal. The lotus designs on the pedestal and those on the shawl flowing down on both sides of the statue are characteristic of Buddhist statues from the seventh century or later. The use of supports to affix the outer and inner molds and traces of injected cast were observed in the interior of the pedestal. The blisters on the arms and pedestal created during the bronze casting indicate the use of lost-wax casting, which was popularly employed for the production of mid- or small-sized gilt-bronze Buddhist statues in ancient times. The composition analysis identified a copper-tin-lead ternary alloy in the interior of the statue that was conventional used in the sixth and seventh centuries. It is likely that this simple alloy was used to facilitate casting and produce clearer expressions of designs and ornaments on the statue. Mercury (Hg) was detected on the surface of the statue, indicating the use of amalgam-plating with gold (Au) dissolved in mercury. This plating method is a common surface treatment technique used for small gilt-bronze statutes in ancient Korea.

Influence of processing parameters for adhesion strength of TiN films prepared by AIP technique

  • Fang, W.;Ju, Yun-Gon;Jo, Dong-Yul;Yun, Jae-Hong;Song, Gi-O;Zhang, S.H.
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.140-141
    • /
    • 2007
  • The arc ion plating (AIP) technique has been used widely for thin coating in the area of surface engineering. The TiN coating is important in the field of dies, cutting tools and other mechanical parts. When forming the TiN films by AIP technique, the processing parameters such as arc power, bias voltage, working pressure, temperature of substrate and pre-treatment affected the adhesion respectively. The results of scratch test revealed that the adhesion strength was influenced by arc power most strongly. And a sequence of the importance of each parameters has been obtained. The crystal structure and cross-section of TiN films are also be investigated.

  • PDF

Effects of Hot Rolling on Microstructures and Magnetic Properties

  • Hong, Byung-Deug;Kim, Jae-Kwan;Cho, Kyung-Mox
    • Journal of Magnetics
    • /
    • v.11 no.3
    • /
    • pp.111-114
    • /
    • 2006
  • We electroplated copper-cobalt thin films on a silicon substrate, which had 150 nm thick copper seed layer. The adhesion between the two metallic layers could be increased by utilizing a proper organic additive, pulse plating technique, and high temperature annealing. The thin films exhibited columnar growth of the deposits and enhanced adhesion. This is attributed to the grain growth mechanism introduced by the additive and annealing.

Outcome Analysis of the Patients with and without Anterior Plating in Multi-Level Degenerative Cervical Diseases (다분절 퇴행성 경추질환에서의 전방 금속판 사용 유무에 따른 환자의 예후분석)

  • Kim, Sang Woo;Kim, Sung Min;Shin, Dong Ik;Cho, Yong Jun;Shim, Young Bo;Choi, Sun Kil
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.12
    • /
    • pp.1369-1374
    • /
    • 2001
  • Objectives : The rates of pseudarthrosis for two- and three level fusion have been reported to be 17-63 and 50% without anterior cervical plating. The purpose of this study is to assess the effects of anterior cervical plating in the treatment of multilevel degenerative cervical disease such mostly the additional risks associated with hardware implants and its benefits, fusion rate and radiographic results, and clinical outcomes. Methods : Forty-seven patients who underwent operations between 1993 and 1997 were retrospectively reviewed. The technique for operation was same for both groups(Smith Robinson with autologous iliac bone graft). Group I consisted of 35 consecutive patients treated with anterior cervical decompression and fusion with anterior cervical plate fixation. Group II consisted of 12 consecutive patients treated without plate fixation. We compared clinical outcomes by Prolo score, radiographic results in the rate of fusion, cervical lordosis by Gore angle, disc height by Farfan method, and surgical complications between two groups. Results : The favorable clinical outcomes(excellent and good) by Prolo score were observed with the use of anterior cervical plate fixation(89% vs 75%). The successful fusion rate of multilevel cervical fusion was as seen with anterior cervical plate fixation(97% vs 75%). The overall graft complication rate in multilevel fusions was decreased, with anterior cervical plate fixation, and the hardware related complications were relatively minimal without serious consequences. Conclusion : Anterior cervical plate fixation in the treatment of multilevel cervical disorders is an effective stabilizing method which provides increased bony fusion rate, decreased graft complications, maintained cervical lordosis, early mobilization of the these patients without serious hardware related complications.

  • PDF

Electroless plating of buried contact solar cell (전극함몰형 태양전지의 무전해도금)

  • Dong Seop Kim;Eun Chel Cho;Soo Hong Lee
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.6 no.1
    • /
    • pp.88-97
    • /
    • 1996
  • The metallization is the key to determining cell costs, cell performance, and system reliability. Screen printing technology suffers from several limitations affecting mainly the front grid. The buried contact solar cell (BCSC) was specifically desinged to be compatible with low cost, mass production techniques and avoid the conventional metallization problem. By using electroless plating technique, we performed this metallization inexpensively and reliably. This paper presents the details of the optimization procedure of metallization schemes on laser grooved cell surfaces. Commercially available Ni, Cu and Ag plating solutions were applied for the cell metallization. The application of those solutions on the buried contact front metallization has resulted in an cell efficiency of 18.8%. The cell parameters are an open circuit voltage of 651 mV, short circuit current density of 37.1 mA/$\textrm{cm}^2$, and fill factor of 77.8 %. The efficiency of over 18 % was achieved in the above 90% of the batch.

  • PDF