Effect of Plating Condition and Surface on Electroless Co-Cu-P Alloy Plating Rate (무전해 Co-Cu-P 도금속도에 미치는 도금 조건과 표면상태의 영향)

  • Oh, L.S.
    • Journal of Power System Engineering
    • /
    • v.4 no.2
    • /
    • pp.31-39
    • /
    • 2000
  • Relationships between the plating condition and the plating rate of the deposition film for the electroless plating of Co-Cu-P alloy were discussed in this report. The result obtained from this experiment were summarized as follow ; The optimum bath composition was consisted of 0.8 ppm thiourea as a stabilizing agent. Composition of the deposit was found to be uniform after two hours of electroless plating. Plating rates of nickel-catalytic surface and zincate-catalytic surface were found to be very closely equal, but the plating time of nickel-catalytic surface took longer than that of the zincated-catalytic surface.

  • PDF

Effect of Plating Condition and Plating Rate on the Magnetic Properties of Electroless Ni-Cu-P Deposits (무전해 Ni-Cu-P 도금층의 자성에 미치는 도금조건과 도금속도의 영향)

  • Oh, I.S.;Lee, T.H.
    • Journal of Power System Engineering
    • /
    • v.10 no.3
    • /
    • pp.58-66
    • /
    • 2006
  • The effect of bath composition, plating condition and plating rate on the magnetic properties of electroless Ni-Cu-P deposits were investigated. With increasing $CuSO_4$ concentration in the bath, plating rate increased, while the Br value of deposits decreased Sharply. Plating rate increased up to 34% with the addition of 200ppm of NaF and 0.8ppm of Thiourea to the bath. Plating reaction had been ceased by the increase of pH above 11.3, bath temperature higher than $90^{\circ}C$ and under $70^{\circ}C$. The Br value of deposit was uniform with various concentration of complexing agent (Sodium citrate, Ethylenediamine) in the bath. The Br value of deposit was almost equal to that found by the addition of stabilizer(Thiourea) and accelerator(NaF). The Br value of deposit was uniform in plating time(120 min) and heat treatment temperature(below $200^{\circ}C$), and were confirmed to have adequate bath stability for practical use.

  • PDF

Selective Contact Hole Filling by electroless Ni Plating (무전해 Ni 도금에 의한 선택적 CONTACT HOLE 충전)

  • 우찬희;권용환;김영기;박종완;이원해
    • Journal of Surface Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.189-206
    • /
    • 1992
  • The effect of activation and electroless nickel plating conditions on contact properties was investi-gated for selective electroless nickel plating of Si wafers in order to obtain an optimum condition of con-tact hole filling. According to RCA prosess, p-type silicon (100) surface was cleaned out and activated. The effects of temperature, DMAB concentration, time, and strirring were investigated for activation of p-type Si(100) surface. The optimal activation condition was 0.2M HF, 1mM PdCl2, 2mM EDTA,$ 70^{\circ}C$, and 90sec under ultrasonic vibration. In electroless nickel plating, the effect of temperature, DMAB concentra-tion, pH, and plating time were studied. The optimal plating condition found was 0.10M NiSO4.H2O, 0.11M Citrate, pH 6.8, $60^{\circ}C$, 30minutes. The contact resistance of films was comparatively low. It took 30minutes to obtain 1$\mu\textrm{m}$ thick film with 8mM DMAB concentration. The film surface roughness was improved with decreasing temperature and decreasing pH of the plating solution. The best quality of the film was obtained at the condition of temperature $60^{\circ}C$ and pH 6.0. The micro-vickers hardness of film was about 800Hv. Plating rate of nickel on the hole pattern was slower than that of nickel on the line pattern.

  • PDF

Effect of Plating Condition and Plating Rate on the Magnetic Properties of Electroless Co-Cu-P Deposits (무전해 Co-Cu-P 도금층의 자성에 미치는 도금조건과 도금속도의 영향)

  • Oh, I.S.;Park, S.D.
    • Journal of Power System Engineering
    • /
    • v.8 no.3
    • /
    • pp.36-43
    • /
    • 2004
  • The effect of bath composition, plating condition and plating rate on the magnetic property of electroless Co-Cu-P deposits were investigated. With increasing $CuCl_2$ concentration in the bath, plating rate increased, while the Br value of deposit decreased sharply. Deposited surface were inferiority by the increase pH above 10.5, bath temperature higher than $80^{\circ}C$. Plating reaction had been ceased by the increase of pH above 11, bath temperature higher than $90^{\circ}C$ and under $40^{\circ}C$. The Br value of deposit was uniform with various concentration of complexing agent(sodium citrate) in the bath. The Br value of deposit was almost equal to that found by the addition of stabilizer (thiourea) and accelerator(NaF). The Br value of deposit was uniform in plating time(20min) and heat treatment temperature(below $200^{\circ}C$), and were confirmed to have adequate bath stability for practical use.

  • PDF

The Surface Improvement by Supercritical Nano Plating (슈퍼크리티컬 나노 플레이팅에 의한 표면개질)

  • Kim, Yun-Hae;Bae, Chang-Won;Kim, Do-Wan;Moon, Kyung-Man;Kim, Dong-Hun;Jo, Young-Dae;Kang, Byung-Yoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.9
    • /
    • pp.913-921
    • /
    • 2009
  • In this study, supercritical nano plating was performed to observe its effect on materials. Using supercritical carbon dioxide as a solvent, we observed how different pressures and temperatures of the supercritical fluid affected the process and its outcome. The plating current increases as pressure increases from 8 MPa to 16 MPa, but it decreases after that. Similarly, the plating current increases as temperature is increased from $35^{\circ}C$ to $45^{\circ}C$, but the current decreases after that. Also, the thickness of the wet electrolyte plating is about $35\sim50{\mu}m$, while the thickness of the plating done using supercritical fluid is about $20\sim25{\mu}m$. At the results, It to it is considered that supercritical nano plating enable to form more thin and stable plating than wet electroplating methods. Also both of the electroplating methods could be affected plating quality by surface condition, and the supercritical nano plating has been confirmed to product more uniform plating surface than wet electroplating.

The Supplement of Sn/Cu, Plating Solution Affects in Plating Skim Quality of the Plating Product (Sn/Cu 도금액의 보충이 도금제품의 도금피막특성에 미치는 영향)

  • Jeon, Taeg-Jong;Ko, Jun-Bin;Lee, Dong-Ju
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.7
    • /
    • pp.112-119
    • /
    • 2009
  • The purpose of this study is to evaluate the evaluation of process yield performed by using Sn & Cu treatment on the surface to optimize process condition for Lead-free solder application. The materials which are used for the New Surface Treatment study are Semi-Dulling plating for high speed Sn/Cu alloy of Soft Alloy GTC-33 Pb free known as "UEMURA Method" and plating substrate is alloy 42.Especially in lead-free plating process, it is important to control plating thickness and Copper composition than Sn/Pb plating. Evaluated and controlled plating thickness $12{\pm}3um$, Copper composition $2{\pm}1%$, plating particle and visual inspection. The optimization of these parameters and condition makes it makes possible to apply Sn/Cu Lead-free solder from Sn/Pb alloy.

A Study on Working Condition of the Pb Free Plating Process Using the Plating Soluction of Sn/Cu (Sn/Cu 도금액을 이용한 무연 도금공정의 작업조건에 관한 연구)

  • Jeon, Taeg-Jong;Ko, Jun-Bin;Lee, Dong-Ju
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.18 no.2
    • /
    • pp.234-240
    • /
    • 2009
  • In this study, we found that it is important to have a specific management of standards which are the $12{\pm}3{\mu}m$ of plating thickness and $2{\pm}1%$ of tuning. To verify these standards, we checked the plating thickness and density of tuning through marginal valuation of each and checked size of a plating particle, adhesion of solder and condition of reflow after a section chief.

The Effect of Barrel Vibration Intensity to the Plating Thickness Distribution

  • Lee, Jun-Ho;Roselle D. Llido
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1999.10a
    • /
    • pp.15-15
    • /
    • 1999
  • In chip plating, several parameters must be taken into consideration. Current density, solution concentration, pH, solution temperature, components volume, chip and media ratio, barrel geometrical shape were most likely found to have an effect to the process yields. The 3 types of barrels utilized in chip plating industry are the conventional rotating barrel. vibrational barrel (vibarrel), and the centrifugal type. Conventional rotating barrel is a close type and is commonly used. The components inside the barrel are circulated by the barrel's rotation at a horizontal axis. Process yield has known to have higher thickness deviation. The vibrational barrel is an open type which offers a wide exposure to electrolyte resulting to a stable thickness deviation. It rotates in a vertical axis coupled with multi-vibration action to facilitate mixed up and easy transportation of components, The centrifugal barrel has its plated work centrifugally compacted against the cathode ring for superior electrical contact with simultaneous rotary motion. This experiment has determined the effect of barrel vibration intensity to the plating thickness distribution. The procedures carried out in the experiment involved the overall plating process., cleaning, rinse, Nickel plating, Tin-Lead plating. Plating time was adjusted to meet the required specification. All other parameters were maintained constant. Two trials were performed to confirm the consistency of the result. The thickness data of the experiment conducted showed that the average mean value obtained from higher vibrational intensity is nearer to the standard mean. The distribution curve shown has a narrower specification limits and it has a reduced variation around the target value, Generally, intensity control in vi-barrel facilitates mixed up and easy transportation of components, However, it is desirable to maintain an optimum vibration intensity to prevent solution intrusion into the chips' internal electrode. A cathodic reaction can occur in the interface of the external and internal electrode. $2HD{\;}+{\;}e{\;}{\rightarrow}20H{\;}+{\;}H_2$ Hydrogen can penetrate into the body and create pressure which can cause cracks. At high intensity, the chip's motion becomes stronger, its contact between each other is delayed and so plating action is being controlled. However, the strong impact created by its collision can damage the external electrode's structure thereby resulting to bad plating condition. 1 lot of chip was divided into two equal partion. Each portion was loaded to the same barrel one after the other. Nickel plating and tin-lead plating was performed in the same station. Portion A maintained the normal barrel vibration intensity and portion B vibration intensity was increased two steps higher. All other parameters, current, solution condition were maintained constant. Generally, plating method find procedures were carried out in a best way to maintained the best plating condition. After plating, samples were taken out from each portion. molded and polished. Plating thickness was investigated for both. To check consistency of results. 2nd trial was done now using different lot of another characteristics.

  • PDF

COMPARISON OF THE FRICTIONAL RESISTANCE BETWEEN NON-ION PLATED AND TiN ION PLATED TO THE ORTHODONTIC APPLIANCE (TiN피막 처리된 교정 장치물의 마찰 저항력에 관한 비교연구)

  • Jang, Si-Ho;Kwon, Oh-Won;Kim, Kyo-Han
    • The korean journal of orthodontics
    • /
    • v.23 no.4 s.43
    • /
    • pp.671-691
    • /
    • 1993
  • To estimate the possibility in the application of TiN ion-plating to the orthodontic appliance, this study investigated frictional force and frictional coefficient between non-ionplated and TiN ion-plated to the orthodontic appliance. The obtained results were as follows : 1. For each group, the frictional force between metal bracket and arch wire in the wet condition was exhibited lower than that in the dry condition. 2. In the dry condition, the frictional force was lowest with fourth group, and it increased in the order of the 3rd, 1st, and 2nd group. Same situation happened in the wet condition. 3. Experimental results using ceramic & plastic bracket showed that group B was lower than group A, and group D was similar to group C. 4. The surface texture after experiment showed that the scratch due to a friction with bracket was observed in an arch wire of dry contition. Also the surface of bracket was rougher than before. 5. We observed that a specimen surface processed with the TiN ion plating was smoother than that of without the TiN ion plating. 6. The surface texture of a metal bracket and an arch wire in the wet condition was observed smoother than that in the dry condition. 7. In the dry condition, the friction coefficient of each specimen was very similar to each other, but in the wet condition, the friction coefficient of specimen processed with the TiN ion plating showed lower values.

  • PDF

Corrosion Behavior of Nickel-Plated Alloy 600 in High Temperature Water

  • Kim, Ji Hyun;Hwang, Il Soon
    • Corrosion Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.61-67
    • /
    • 2008
  • In this paper, electrochemical and microstructural characteristics of nickel-plated Alloy 600 were investigated in order to identify the performance of electroless Ni-plating on Alloy 600 in high-temperature aqueous condition with the comparison of electrolytic nickel-plating. For high temperature corrosion test of nickel-plated Alloy 600, specimens were exposed for 770 hours to typical PWR primary water condition. During the test, open circuit potentials (OCP's) of all specimens were measured using a reference electrode. Also, resistance to flow accelerated corrosion (FAC) test was examined in order to check the durability of plated layers in high-velocity flow environment at high temperature. After exposures to high flow rate aqueous condition, the integrity of surfaces was confirmed by using both scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS). For the field application, a remote process for electroless nickel-plating was demonstrated using a plate specimen with narrow gap on a laboratory scale. Finally, a practical seal design was suggested for more convenient application.