• 제목/요약/키워드: Platform Screen Door, PSD

검색결과 64건 처리시간 0.028초

지하철 승강장 열차풍 특성 분석 (Train Wind Analysis of Subway Platforms)

  • 배성준;황선호;신창헌;김신도;이경빈;박덕신
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.100-106
    • /
    • 2011
  • PSD(platform screen door) was completely installed at all of Seoul subway station(line 1~8) using 640million people per day by 2010. After installation of PSD, the influence of train induced wind at platform decreased, but is estimated to increase in subway tunnel. In this paper, train induced wind occurred by pass of subway at platform was measured and analyzed using numerical analysis by computational fluid dynamics.

  • PDF

승강장 스크린도어 설치에 따른 배연설비운영에 대한 연구 (A Study of Smoke Exhaust Facility Operation of Subway Platform with Installation of Platform Screen Door)

  • 이동호;고재웅;김하영
    • 한국안전학회지
    • /
    • 제21권1호
    • /
    • pp.35-40
    • /
    • 2006
  • A study on fire phenomena in a subway transit mass station has been carried out as a part of disaster prevention plan at the subway station. The ventilation facilities installed in both the platform and the trackway are designed to convert into a smoke exhaust system in emergency situation, creating such an environment as necessary for evacuation. 3 dimensional Numerical Simulations based on the CFD are carried out using a simulation tool, Fire Dynamic Simulator. Additionally, four different vent modes are made and performances are compared with the original design mode and each other to find better operation of vents at both the platform and the trackway in case of fire. From the result, an vent operational characteristics under the condition of installed PSD is clarified for the effective smoke and heat removal from the platform area compared with non installed PSD.

PSD 설치에 따른 도시철도차량의 Kinematic Envelope 영향 분석 (Kinematic Envelope Effect Analysis of the Urban Transit EMU According to PSD Installation)

  • 정종덕;편장식;조희제;홍용기
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1779-1784
    • /
    • 2010
  • Since PSD(Platform Screen Door) is set up at many subway stations, its design related to a safety becomes gradually important. Especially the intereference check with a running railway vehicle is the most important of performance indices. This study proposes a dynamic analysis models for the railway vehicle and rail. Some design parameters are considered in the models to find a correlation to the performance.

  • PDF

지하철 스크린도어 설치 시 화재 강도에 따른 승강장 열 환경 해석

  • 조정훈;이동호;권용일;김종원
    • 한국산업안전학회:학술대회논문집
    • /
    • 한국안전학회 2001년도 공동학술대회
    • /
    • pp.73-78
    • /
    • 2001
  • 현재 많은 나라에서 지하철 역사에 승강장 스크린 도어(Platform Screen Door)를 설치하여 열차진입에 따른 승강장부의 공조환경 개선 및 승객의 안전을 확보하고자 하고 있다. 한국에서도 서울 지하철 9호선을 비롯하여 각 도시에서 PSD를 지하철 승강장부에 설치하는 노력이 시도되고 있으나, 이에 대한 검증은 전무한 실정이다 한국에서의 지하철 이용 분담율은 30%정도이며, 향후 약 50%까지 이를 것으로 예상되며, 이에 따라 PSD설비는 증가할 것으로 전망된다. 따라서 PSD 설치에 대한 지하철역사 환기 및 화재시의 배연설비에 대한 연구의 필요성은 날로 논아지고 있는 실정이다.(중략)

  • PDF

수동 Mode에서 PSD System 최적화 연구 (A Study on PSD System optimization from manual mode)

  • 손영진;민경윤;이강원;방연근
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.162-167
    • /
    • 2004
  • The ascent and descent market screen door (PSD-Platform Screen Door) between the electromotive car which is in the process of operating from the subway ascent and descent market and the passenger it is an immediacy and crisis as the system which it intercepts currently the inside and outside of the country of course signal system automatic operation signal system (ATO) establishment is operated from the segment. Manual operation signal system (the ATS and the ATC) almost it is a condition which is wholly lacking from the segment. This year from second half of the year 2 line manual operation signal system (ATS). It established the shutting tightly elder brother and the railing elder brother in PSD system in segment 12 reverses and the death accident due to the passenger hurt accident which occurs from the subway. It prevented an energy curtailment in the same time when it raises air cooling efficiency, It gathered it restricted the underground space which is comfortable in the use citizen and and and service it did interface the electromotive car and PSD entrance and exit literature course from the manual operation segment to sleep technically optimizationt. It researched a minute dust diffusion.

  • PDF

2.4GHz 무선 통신을 이용한 PSD 인터페이스 개선에 관한 연구 (A Study on Improvement of PSD Interface Using 2.4GHz Wireless Communication,)

  • 김재필;현용섭;장경송
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1408-1415
    • /
    • 2007
  • To operate Platform Screen Door (PSD) automatically, the operational data of PSD and the train must be interfaced properly. PSD and train are operated together by the signaling system in Automatic Train Operation (ATO) signaling system zone where interfaces are provided between PSD and train. However, the additional PSD interface system with train is required in train operating zone without the interface between PSD and train. For the PSD interface, the wireless communication system or the train status (train correct stop status / train door status) detection system has been used. Seoul Metro line No.2. has the PSD wireless communication system using 447MHz band RF. For the safety of PSD operation, it is required to prevent RF interference in the subway environment where many frequencies exist. In this paper, the PSD wireless communication system is developed using 2.4GHz band RF to prevent the interference of the wireless communication and increase the traffic of the PSD interface. Furthermore, the improved system can store, manage and display the PSD and train operational data using Human Machine Interface (HMI) in the train's driver cab.

  • PDF

대심도 지하역사에서의 화재시 플랫폼 스크린 도어에 의한 열, 연기 거동 영향 분석 (The Analysis of the effects of the platform screen door on the fire driven flow in The Deeply Underground Subway Station)

  • 장용준;김학범;이창현;정우성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.1984-1989
    • /
    • 2008
  • In this study, fire simulations were performed to analyze the characteristics of the fire driven flow and the effects of the platform screen door on the smoke flow in the station, when the fire occurred in the center of the platform. Soongsil Univ. station (line number 7, 47m in depth underground) was chosen which was the one of the deepest underground subway stations in the Seoul metro, SMRT. The parallel computational method was employed to compute the heat and mass transfer eqn's with 6 CPUs of the linux clustering machine. The fire driven flow was simulated with using FDS code in which LES method was applied. The Heat release rate was 10MW and The Ultrafast model was applied for the growing model of the fire source. The 10,000,000 structured grids were used.

  • PDF

무인운전 차량의 도어 및 PSD 제어 신호에 대한 연구 (Research for Signal Interfaces between DOORS of DRIVERLESS TRAIN and PSD Control)

  • 이희창;김동일;전상훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.857-865
    • /
    • 2010
  • Recently the demand of the driverless rolling stock is increasing with advancement of the stable communication technique and control technique. The automatic train operating system has advantages which takes low operating cost and is able to dispose elastically in demand. Beside it provides high safety and effectiveness because it will be able to control power, signal and communication system from Operation Control Center and the safety and effectiveness are high. The establishment of PSD, Platform Screen Door, is advanced in the goal which is passenger safety, fire protection, noise and dust reduction etc. When but, two advanced systems also have risks of operation delay and accident when two systems are not controlled smoothly. Thus, I'll introduce control method between onboard controller, door control unit in rolling stock and PSD controller to help system design.

  • PDF

열차 운행에 따른 상대식 승강장에서 지하철 승강장 스크린 도어 풍압해석 (THE PRESSURE-TRANSIENT ANALYSIS ON THE PLATFORM SCREEN DOORS OF THE SIDE PLATFORMS IN A SUBWAY STATION WITH VARIOUS OPERATING CONDITIONS)

  • 이명성;안혁진;원찬식;허남건
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 학술대회
    • /
    • pp.283-289
    • /
    • 2008
  • The pressure-transient on platform screen doors in side platforms caused by passing trains with various operating conditions have been investigated numerically. The transient compressible three-dimensional flow simulations are performed with actual operating conditions of two trains by adopting moving mesh technique. To achieve more realistic results, the detailed shape of train and the subway station including tunnels connecting the adjacent stations are represented in the computational domain. Numerical analyses are carried out for cases considering arriving/passing/departing train with or without train stopped on the opposite track, and both trains on the move in opposite direction. From the numerical results, the maximum pressure on the platform screen doors, which is predicted in the case of two passing trains, satisfied the design standards for similar stations.

  • PDF