• 제목/요약/키워드: Plate type electrode

검색결과 123건 처리시간 0.03초

침대 평판형 플라즈마장치의 코로나 방전 및 오존발생 특성에 미치는 원통형 3전극의 영향 (Effect of a Cylindrical Third Electrode of a Point-Plate Type Plasma Reactor on Corona Discharge and Ozone Generation Characteristics)

  • 문재덕;정호준;정재승
    • 전기학회논문지
    • /
    • 제56권5호
    • /
    • pp.933-937
    • /
    • 2007
  • A point plate type nonthermal plasma reactor, with a grounded cylindrical third electrode which closely- encompasses the needle point, have been investigated with an emphasis on the role of the third electrode. It was found that the point plate airgap, with the grounded third electrode, had a switching characteristic on its I V characteristics for negative and positive discharges, which is very different from that of a conventional point plate airgap without a third electrode. The corona discharge and ozone generation characteristics of the plasma reactor with the grounded cylindrical third electrode, such as the corona onset voltage. the breakdown voltage. the corona current. and the amount of output ozone, were influenced significantly by the height of the third electrode. and these characteristics can be controlled by adjusting the height of the third electrode.

CFD 모사 기법을 이용한 전해반응기 내부 흐름 특성 분석 (Flow Characteristics Analyses within the Electrolysis Reactor using the CFD Simulation Technique)

  • 정종식;이승재;이재복
    • 상하수도학회지
    • /
    • 제30권6호
    • /
    • pp.745-753
    • /
    • 2016
  • The objective of this study was to investigate design factors of the electrolysis reactor through the CFD(computational fluid dynamics) simulation technique. Analyses of velocity vector, streamline, chloride ion concentration distribution showed differences in flow characteristics between the plate type electrode and the porous plate type electrode. In case of the porous plate type electrode, chlorine gas bubbles generated from the anode made upward density flow with relatively constant velocity vectors. Electrolysis effect was more expected with the porous plate type electrode from the distribution of chloride ion concentration. The upper part of the electrolysis reactor with the porous plate type electrode had comparatively low chloride concentration because chloride was converted to the chlorine gas formation. Decreasing the size and increasing total area of rectifying holes in the upper part of cathodes, and widening the area of the rectifying holes in the lower part of cathodes could improve the circulation flow and the efficiency of electrolysis reactor.

선대 평판형 플라즈마장치의 코로나 방전 및 오존발생 특성에 미치는 바이어스된 3전극의 영향 (Effect of the Biased Third Electrode of a Wire-Plate Type Plasma Reactor on Corona Discharge and Ozone Generation Characteristics)

  • 정재승;문재덕
    • 전기학회논문지
    • /
    • 제57권4호
    • /
    • pp.648-652
    • /
    • 2008
  • Corona discharge and ozone generation characteristics of a wire-plate plasma reactor, with a biased third electrode, have been investigated with an emphasis on the role of the bias voltage and frequency applied on the third electrode. It was found that the wire-plate plasma reactor, with the biased third electrode, had a switching characteristic on its I-V characteristics for negative and positive discharges, which is very different from that of a conventional wire-plate plasma reactor without the third electrode. As a result, the corona discharge and ozone generation characteristics of the proposed plasma reactor could be controlled by adjusting the bias voltage and frequency of the third electrode. The corona onset and breakdown voltages, and ozone generation and yield, were increased compared with those of without the third electrode. These, however, reveal the effectiveness of the biased third electrode.

광폭 전기집진기의 집전특성에 관한 연구 - I. 집진판 간격과 방전극의 영향 -

  • 김용진;하병길;정상현;홍원석;여석준;유주식
    • 설비공학논문집
    • /
    • 제13권10호
    • /
    • pp.939-946
    • /
    • 2001
  • This study investigates the electrical and collection characteristics of a wide plate spacing electrostatic precipitator (ESP), using a pilot-scale one. Electrical operating characteristics and collection efficiency were measured for various shapes of discharge electrodes. The collection plate spacing ranged from 300 to 550 mm. Results of electrical characteristic and collection efficiency tests as a function of collection plate spacing, discharge electrode type, applied voltage, and particle diameter were obtained. Increasing the collection plate pitch and altering the corona electrode geometry was found to increase the collection efficiencies without increasing input power requirement. The best efficiency is achieved for the discharge electrode of twisted pin type.

  • PDF

수중 스트리머 방전용 플라즈마 반응기 구조에서 수소발생 특성 (The Characteristic of Hydrogen Generation on the Structure of Plasma Reactor Using the Streamer Discharge in the Water)

  • 박재윤;김종석
    • 조명전기설비학회논문지
    • /
    • 제20권4호
    • /
    • pp.37-42
    • /
    • 2006
  • 본 논문에서는$CO_2$를 발생시키지 않고 물로부터 직접 수소를 제조하기 위하여 비열플라즈마를 이용하였다. 다중침-평판형(Multineedle-plate electrode geometry reacto: MPER)과 단일침-평판형(Needle-plate electrode geometry reactor: NPER) 두종류의 수소제조 반응기를 설계 제작하여 수소 발생에 미치는 영향에 대하여 실험하였다. 수소발생을 높이기 위해서는 강한 아크성 스트리머 방전 발생과 효과적인 수표면 방전을 위한 수표면 조건을 고려해야만 된다.

역극성 전압인가와 적층법을 이용한 판형오존발생기의 특성개선 (Characteristics Improvement of Plate-Type Ozonizer using Inverse-Polarity Voltage and Accumulative Method)

  • 이상근;박용권;이동욱;전병준;송현직;이광식
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권12호
    • /
    • pp.614-621
    • /
    • 2001
  • In this Paper, the ozonizer is fabricated by piling plate-type electrodes up to minimize and reduce install space. Hereby ozone generation characteristics of piled plate-type ozonizer were investigated. Inverse-polarity voltage was generated by H.V neon transformer. And 2 H.V neon transformers were used to supply high voltage each 9 electrodes of plate-type ozonizer. According to the experiments, ozone concentration, generation and yield were proportionally increased tilth increasing the number of electrode. And the maximum increase effects of 246%, 245%, and 33% were obtained when the number of electrode were increased from 3 up to 9.

  • PDF

장벽 방전형 공기 펌프의 이온풍 발생에 미치는 방전전극 형상의 영향 (Effect of Discharge Electrode Shape of a Barrier Discharge Type Gas Pump on Ionic Wind Generation)

  • 황덕현;문재덕
    • 전기학회논문지
    • /
    • 제58권5호
    • /
    • pp.994-998
    • /
    • 2009
  • Existing cooling technologies no longer provide adequate heat dissipation due to excessive heat generation caused by the growing component density on electronic devices. An ionic gas pump can be used for the thermal management of micro-electronic devices, since the size of pump can be reduced to a micrometer scale. In addition, the gas pump allows for gas flow control and generation without moving parts. This ideal property of gas pump gives rise to a variety of applications. However, all these applications require maximizing the wind velocity of gas pump. In this study a barrier discharge type gas pump, with a needle-shaped corona electrode instead of a plate-shaped corona electrode, has been investigated by focusing on the corona electrode shape on the wind velocity and wind generation yield. As a result, the enhanced wind velocity and wind generation yield of 1.76 and 3.37 times were obtained with the needle-shaped corona electrode as compared with the plate-shaped corona electrode of the proposed barrier discharge type gas pump.

3전극이 부설된 틈새 장벽방전형 플라즈마장치의 코로나 방전 및 오존발생 특성 (Corona Discharge and Ozone Generation Characteristics of a Slit Dielectric Barrier Discharge Type Plasma Reactor with a Third Electrode)

  • 문재덕;정재승
    • 전기학회논문지
    • /
    • 제56권3호
    • /
    • pp.583-587
    • /
    • 2007
  • Corona discharge and ozone generation characteristics of a slit dielectric barrier discharge type wire-plate plasma reactor with a third electrode have been investigated. When a third electrode is installed on a slit of the slit barrier, where an intense corona discharge occurs, it is found that a significantly increased ozone output could be obtained. This, however, indicates that the third electrode can activate the corona discharges both of the discharge wire and the slit of the slit barrier in the plasma reactor. As a result, a thin stainless wire, used as the third electrode has a strong effect to influence the corona discharge of the slit and corona wire, especially to the negative corona discharge. Higher amounts of the output ozone and ozone yield, about 1.27 and 1.29 times for the negative corona discharge, can be obtained with the third electrode, which reveals the effectiveness of the third electrode.

수중 방전과 공간전하제어에 의한 효과적인 산화성물질 발생특성 (Effective Oxidant Generation and Ion Precipitation Characteristics of Electrolyzing Cell by Discharge and Space Charge Control)

  • 김진규;이대희;문재덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.9-12
    • /
    • 2000
  • A new type electrolyzing cell with slits on parallel plate electrodes and wire-to-cylinder type electrode system has been proposed instead of the conventional parallel plate type. An investigation was carried out on the effect of the number and size of slits on ion precipitation and oxidant generation characteristics, evidenced by eliminated space charge limiting action and by elevated electric fields in active interelectrode spacing. And it is also studied on the effect of the diameter of wire electrode to ion precipitation and oxidant generation characteristics. With electrode with 48 slits, very oxidants generation water of 3.1 [ppmm] and 19.0 [ppmm] in positive electrode side were obtained with tap water and 0.1 [wt%] NaCl dissolved tap waterfed. In addition, with wire-to-cylinder type electrode system, it is found that oxidant contained water of 0.48 [ppmm] and 5.46 [ppmm] in positive electrode side were obtained with tap water and 0.1 [wt%] NaCl dissolved tap water fed for the case of discharge electrode diameter of 0.5 [$mm{\phi}$]. Consequently, very high ion precipitation and dense oxidant generation characteristics can be realized by having slits on the electrodes of conventional cell as these slits increase the electric fields and decrease the space charge limiting actions in interelectrode spacing.

  • PDF

도시철도 지하터널용 전기집진기 개발을 위한 집진극 형상에 대한 기초연구 (A Study on Collecting Electrode Design for Developing Electrostatic Precipitator(ESP) of Urban Railway Underground Tunnels)

  • 구태용;김용민;홍정희;황정호
    • 한국입자에어로졸학회지
    • /
    • 제9권2호
    • /
    • pp.79-87
    • /
    • 2013
  • In this study, the characteristics of turbulent flow and collection efficiency for an one-stage electrostatic precipitator(ESP) with slit type collecting electrode for urban railway underground tunnels were obtained using computational fluid dynamics(CFD) commercial code FLUENT 6.3 and lab-scale experiments. The electrostatic precipitator was operated under high gas velocity(3~12m/s). Five different designs of collecting electrode, flat plate-type and a slit-type of 3mm, 5mm, 7mm and 10mm slit width and four various gas velocity(3, 6, 9, and 12m/s) were used and applied. A standard k-${\varepsilon}$ model in CFD commercial code FLUENT 6.3 was used for flow simulation. The flow simulation results showed that the turbulent intensity of flat plate-type was higher than slit-type under all gas velocity conditions and also the turbulent intensity of flat plate-type was increased continuously, but in case of slit-type was maintained at constant range. And, the turbulent intensity was decreased according to increasing of slit width. The experimental results showed that the collection efficiency of slit-type was higher than flat plate-type under all gas velocity conditions. And, over 6m/s gas velocity condition, the collection efficiency of 5mm and 7mm was highest, when compared to 3mm and 10mm.