• Title/Summary/Keyword: Plate test

Search Result 3,129, Processing Time 0.025 seconds

Effect of a vertical guide plate on the wind loading of an inclined flat plate

  • Chung, Kung-Ming;Chou, Chin-Cheng;Chang, Keh-Chin;Chen, Yi-Jun
    • Wind and Structures
    • /
    • v.17 no.5
    • /
    • pp.537-552
    • /
    • 2013
  • Wind tunnel experiments were performed to study the wind loads on an inclined flat plate with and without a guide plate. Highly turbulent flow, which corresponded to free-stream turbulence intensity on the flat roof of low-rise buildings, was produced by a turbulence generation grid at the inlet of the test section. The test model could represent a typical solar collector panel of a solar water heater. There are up-stream movements of the separation bubble and side-edge vortices, more intense fluctuating pressure and a higher bending moment in the turbulent flow. A guide plate would result in higher lift coefficient, particularly with an increased projected area ratio of a guide plate to an inclined flat plate. The value of lift coefficient is considerably lower with increased free-stream turbulent intensity.

A Study on the Strength Comparison of Steel Pipe Support using the Structural Analysis Program (구조해석에 의한 파이프서포트의 내력비교에 관한 연구)

  • Paik, Shin-Won;Park, Jong-Keun
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.4
    • /
    • pp.67-71
    • /
    • 2008
  • Formwork is a temporary structure that supports its weight and that of fresh concrete as well as construction live loads. Slab formwork consists of sheathing, stringer, hanger and shore. In construction site, pipe supports are usually used as shores which are consisted of the slab formwork. In this study, compressive strength of 80 pipe supports was measured by knife edge test and plate test. Buckling load of pipe supports was analyzed by structural analysis program(MlDAS). Theoretical buckling load with/without initial deformation was got by theoretical analysis. According to these results, buckling load which was analyzed by structural analysis program(MlDAS) was larger than compressive strength of knife edge test and plate test. Theoretical buckling load without initial deformation was larger than compressive strength of knife edge test and plate test. But Theoretical buckling load with initial deformation was lower than compressive strength of knife edge test and plate test. Initial deformation equation for test method according to the pipe support length was suggested. Therefore, the present study results will be used to design the slab formwork safely.

Evaluation of Ground Characteristic Using the New Developed Screw Plate Load Test Device (새롭게 개발된 스크류재하시험장치를 이용한 지반특성 파악)

  • Lee, Nam-Woo;Hwang, Woong-Ki;Choi, Yong-Kyu;Kim, Tae-Hyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.3
    • /
    • pp.5-17
    • /
    • 2011
  • Sampling disturbance can often introduce considerable errors in the laboratory estimation of geotechnical properties of soils. Accordingly, it causes inappropriative results in analysing field behavior. Therefore, a screw plate load test, one of in-situ test technique, is developed in this study, because in-situ testing techniques have advantages for the estimation of reliable geotechnical parameters. The screw plate load test, which was modified from the plate load test, conducts an experiment underneath ground by inserting a spiral type of auger screw. In this study, the structure and characteristics of the screw plate load test device are introduced in detail and the reliability of the device is examined through the analysis of the laboratory test results.

Estimation on Bearing Capacity of Environmentally Sustainable Geotextile Gabion Using Oystershell (굴패각을 이용한 친환경적 지오텍스타일 게비언의 지지력 평가)

  • Shin, Eun-Chul;Park, Jeong-Jun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.10 no.6
    • /
    • pp.44-52
    • /
    • 2007
  • Recently, oystershell wastes cause serious environmental problem and the need for the researches on the recycling of oystershell have been increased and various methods are already in operation. Field plate bearing tests and numerical analysis were performed to investigate the bearing capacity of oystershell filled geotextile gabion which utilized the waste oystershell at the coastal oyster farm site. The waste oystershell mixed soil specimens were prepared for the laboratory test and field test in terms of varying blending ratio of granite soil and oystershell. Based on the cyclic plate load test results, the spring constant, subgrade modulus of ground, and the reinforcing parameters were determined. The field plate load test results indicate that the bearing capacity of the soil ground with the oystershell mixed ratio of 20% is greater than that of the original ground. Two-dimensional numerical analysis was evaluated the expected deformation in the given conditions. Analysis results show a similar characteristics on bearing capacity with the results of the field plate load test. These findings suggest that the oystershells are very promising construction materials for landfill and earth embankment in coastal area.

Detection of Sulfa-Drugs and Antibiotics Residues in Raw Milk (원유중의 잔류항생물질 및 썰파제 조사)

  • 박병옥;백미순;권기호;우기방;장기윤
    • Korean Journal of Veterinary Service
    • /
    • v.14 no.1
    • /
    • pp.63-69
    • /
    • 1991
  • Antibiotic residues of raw milks collected in Anyang area were tested by TTC-reduction test, EEC-4plate method and TLC(SOS-kit ) method to improve and monitor the quality of milk. Antibiotic substances were not detected from 100 raw milk samples, but sulfamethazine was detected from only one sample(1.3PPM) by SOS test. Unclassified anti-microbic substances were detected from 22 samples by EEC-4 plate method. EEC-4 plate test was useful to categorize the species of antibacterial substances and SOS test was useful to detect the sulfamethazine field screening test.

  • PDF

A Study on the Antenna Front Plate Design for the Improvement of DF Accuracy (방향탐지 정확도 개선을 위한 안테나 전면판 설계에 관한 연구)

  • Kim, In-Seon;Shin, Im-Seob
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.669-675
    • /
    • 2011
  • In this paper, we present the AFP(antenna front plate)s which were designed to reduce the reflection for the sake of the improvement of DF(direction finding) accuracy. The AFP consists of front plate, absorber and radome. The AFPs were optimized respectively by real test and we performed the DF test using our AFPs in laboratory. The DF test shows that the DF accuracy is about 2 times better than the requirement capability. Then, the DF field test was executed using the AFPs, which were installed in helicopter in consideration of the reflection by platform. The result of the DF field test is superior to the requirement capability also, which shows the validity of our design method.

A new experimental technique on the tubular joints of spatial grid structures

  • Chen, Zhi-Hua;Sun, Guo-Jun;Luo, Zhi-Shan
    • Structural Engineering and Mechanics
    • /
    • v.40 no.6
    • /
    • pp.801-811
    • /
    • 2011
  • A new experimental technique was developed on the plate-inserted welded tubular joints of spatial grid structures. In the experimental technique, a microcomputer controlling instrument of moire intervention (MCIMI) was adopted. A test was designed on the plate-inserted welded tubular joints of spatial grid structures to show the effectiveness of the MCIMI technique. Both traditional electrical measuring technique and MCIMI technique were employed in the test. The test results showed that the MCIMI technique was feasible in the case of the complicated tests on steel structures. The MCIMI technique not only implemented the limitation of traditional electrical measuring technique, but also improved the accuracy of the test. According to the test results, we further examined the plate-inserted welded tubular joints in the cable-stayed spatial grids of the Binhai International Convention & Exhibition in Tianjin, China. The analysis showed the joints are safely designed with adequate conservatism. The research provided a new application of MCIMI in the field of large-scale structure engineering.

Evaluate of bearing capacity by dynamic load in base (동하중에 의한 노상의 지지력 평가)

  • 김종렬;박달수;박정훈
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.279-286
    • /
    • 2002
  • Present all sorts of failure or no failure test methods are done for evaluate structural ability of pavement. It are Plane Plate Test, CBR Test, Benkelman Beam Test, FWD, Dynaflect, etc. but, each method of test not expect compatibility because the result very different by each method of test. Now among pavement's method of evaluation, no failure test gradually use because It quickly and simply obtain pavement's elastic modulus of each layer. But, It accompany expensiveness equipment, and It's degree of trust is lower against expensiveness equipment. Therefore this research practice comparative trustworthy Plane Plate Test, comparative low cost and quick Small FWD Test. And analyzed relation of Plane Plate Test with Small FWD Test.

  • PDF

Characteristics of Bearing Capacity and Settlement According to the Difference of Loading Plate Sizes (재하판의 크기에 따른 지지력 및 침하특성)

  • 정형식;김도열
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.4
    • /
    • pp.179-188
    • /
    • 2002
  • The scale effect should be considered to determine the bearing capacity and settlement of footings from plate-load test, because of the size difference between a footing and a loading plate. To analyze characteristics of bearing capacity and settlement according to the difference of loading plate sizes, model tests were performed with four different sizes of square plate, which are B=10, 15, 20, and 25cm respectively, on five different kinds of subsoils. Test results showed that the ultimate bearing capacity of a footing on the sand did not increase proportional to the traditional formula and the bearing capacity on the clay also increased a little with increasing the size of loading plate. The settlement of test plate on the sand did not increase as the traditional formula of Terzaghi and Peck (1967), and the settlement on the clay also did not increase proportional to the traditional formula.