• Title/Summary/Keyword: Plate load test

Search Result 588, Processing Time 0.032 seconds

A Study on Experiment and Structural Analysis for High-Durability of Orthotropic Steel Deck Bridge (고내구성을 위한 강바닥판교의 실험 및 해석 연구)

  • Kong, Byung-Seung;Kim, Min-Ho
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.462-467
    • /
    • 2007
  • From the research which it sees verification of the whole interpretation and local interpretation of the durability steel deck bridge a static test and it produces the test body which it sells with character and it executes smallness pul lek detailed interpretation it leads and the appropriate characteristic of smallness pul lek detailed interpretation and to sleep a nominal stress price and it compares it judges it does. The stress quality from each structure region which it follows in load stock location it analyzes and from the hazard which evaluates, the objective region the length rib and the bottom grater weld zone, the length rib and width rib connection department and the width rib with the father it divided. It investigated the stress distribution of the test body from these objective location, FEM interpretation it led and the conduct against each structure state tax it analyzed. General conduct the load stock location the floor plate is located in the center with interpretation price together symmetry characteristic to seem, it cannot be like that it cannot there is one actual test price. Like this reason the length rib and width rib connection actually production even production characteristic security it is a day when it is impossible with the curvature junction department which it blows, it follows in examination body deferment condition and form feed with the fact that it is visible a big difference even with error of some it becomes. Consequently for a data and the research which are more accurate it is judged with the fact that the effort which is prudent will be necessary.

  • PDF

Axial Load Test of Prefabricated Composite Columns Using Bolt-connected Steel Angles (볼트접합 앵글을 사용한 합성기둥의 중심축 압축실험)

  • Kim, Hyeon Jin;Hwang, Hyeon Jong;Park, Hong Gun;Kim, Dong Kwan;Yang, Jong Min
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.2
    • /
    • pp.147-158
    • /
    • 2017
  • The present study focused on the structural performance of newly developed prefabricated composite columns (PSRC composite column) using bolt-connected steel angles. Concentric axial loading tests were performed for four 2/3 scaled PSRC column specimens and two conventional SRC column specimens. The test parameters were the spacing and sectional configurations of lateral reinforcement, and width-to-thickness ratio of steel angles. The test results showed that the axial load-carrying capacity and deformation capacity of the PSRC column specimens were comparable to those of the conventional SRC column specimens. Closely spaced steel plates and Z-shaped steel plates for lateral reinforcement increased the deformation capacity of the PSRC column specimens. The load-carrying capacity was greater than the prediction by current design codes. Numerical analysis was performed for the specimens. The results agreed well with the test results in terms of initial stiffness, load-carrying capacity, except for strength degradation due to cover concrete spalling.

An Experimental Study on the Flexural Behavior for the Slabs using the Suspending Deck plate (매닮 데크플레이트를 이용한 슬래브의 휨거동에 관한 연구)

  • Bae, Kyu Woong;Lee, Sang Sup;Park, Keum Sung
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.1
    • /
    • pp.25-34
    • /
    • 2013
  • The purpose of the this paper is experimentally to investigate flexural behavior of slabs with suspending the deck plate. The main experimental parameters are the depth and thickness of the deck plate, slab span, rebar and support conditions. Total number of six specimens were tested and manufactured in slabs under vertical load. Based on the results of the test, the flexural behavior for slabs is determined according to the vertical deformation of the slabs, regardless of the main experimental parameters. Bending rebar reinforcement in the rib cross-section specimens can be evaluated significantly higher initial stiffness, crack stiffness and flexural strength. Result of the comparison of the theory value appeared to be fairly well matched to average 1.05.

A Study on the Development of Force Limiting Devices of Folded Plate Type (절판형 응력제한 기구의 개발에 관한 연구)

  • Kim, Cheol Hwan;Chae, Won Tak
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.6
    • /
    • pp.571-579
    • /
    • 2014
  • The steel braces are used to control the lateral drift of high rise buildings. The braces are designed as tensile members since the braces consisted of slender member can not resist compressive loads by elastic buckling. To resolve this problem, a lot of research were performed to develop the non-buckling member. The force limiting device (FLD.) is one of them. The purpose of this study is the development of FLD. to prevent a elastic buckling for a slender member. The folded plate type is proposed to induce the yielding before occurring elastic buckling. In this study, member test and FEM analysis for proposed type were performed. Further, It is verified that the structure with FLD member is stable by high energy absorption. The proposed folded plate type FLD could be effective to preserve the compressive member from the elastic buckling.

An Experimental Study for the Evaluation of the Structural Behavior Eco Deck Plate (Eco Deck Plate의 구조적 거동 평가를 위한 실험적 연구)

  • Lee, Jin-Eung;Lee, Yong-Jae;Lee, Soo-Kueon;Jung, Byung-Joo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.5
    • /
    • pp.40-48
    • /
    • 2013
  • Eco deck plate system is a construction method that deconstruction of galvanized steel sheets is possible by integrating steel-wire-integrated girders and the galvanized steel sheets with bolts. Therefore, compared with previous steel-wire-integrated deck plates which were joined by welding, the system is acknowledged as the construction method possible management and repair. This study conducted an experimental research by manufacturing total 24 full size specimens in a same condition for 12-shape specimens by two parts to evaluate structural behaviors of the eco deck plates. In the results after the test, permissible deflection for the construction load action was shown to be values under design values and satisfactory. The processing of lattice steel wires was presented to be structurally advantageous in being manufactured by cutting downward. Also, in case of a specimen that D13 as a steel wire was used, destruction occurred at the welding part of the bottom steel wire and the lattice steel wire, so improvement measures for the welding in factory manufacture are necessary.

An Evaluation on Punching Shear Capacity of R/C Flat Plate Slab (RC 플랫 플레이트 슬래브의 뚫림전단성능평가)

  • Kim, Jong-Keun;Shin, Sung-Woo;Yang, Ji-Soo;Lee, Li-Hyung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.3
    • /
    • pp.205-213
    • /
    • 2003
  • The primary purpose of this study is to investigate punching shear capacity of flat plate slab using high strength concrete in column. It may be much contributed to economy efficiency and structural advantages that High Strength Concrete(HSC) used for vertical member and Normal Strength Concrete(NSC) for horizontal member. Therefore, six plate flat slab specimens with HSC column and NSC slab had been made and tested with real scale. The major variables were compressive strength of concrete(fck=285, $460kgf/cm^2$), extended length of HSC from column face and amount of shear reinforcements. As the result of this test, the maximum load and punching shear capacity of specimens is affected by extended length and shear reinforcements.

The Strain Evaluation of the Notch tip Area for the CFRP/GFRP Hybrid Laminate Plate using the SENT Specimen (SENT시험편을 이용한 CFRP/GFRP 하이브리드 적층재의 노치선단부 변형률 평가)

  • Kang, Ji Woong
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.5
    • /
    • pp.15-21
    • /
    • 2014
  • The aim of this work is conduct the study on light weight and structural performance improvement of the composite wind power blade. GFRP (Glass Fiber Reinforced Plastic) pre-empted by CFRP(Carbon Fiber Reinforced Plastic), the major material of wind power blade, was identified the superiority of mechanical performance through the tensile and fatigue test. SENT(Single Edge Notched Tension) specimen fracture test was conducted on the specimen that laminated together 2 ply CFRP with 4 ply GFRP through DIC(Digital Image Correlation) analysis. The SENT specimen thickness and $a_0/W$ ratio is 1.45 mm and 0.2, respectively. The fracture test accomplished with displacement control with 0.1 mm/min at the room temperature. The experimental apparatus used for the fracture test consisted of a 50kN universal dynamic tester and CCD camera connected to a personal computer (PC), which was used to record images of the specimen surface. Following data acquisition, the images and load-displacements were transferred to the PC, on which the DIC software was implement. The experiment and DIC analysis results show that CFRP/GFRP laminated composite exhibits improvement of the strength, compared with that of the existing blade material. This study shows the result that the strength of CFRP rotor blade of wind turbine satisfies through the experimental and DIC method.

Effect of arbitrarily manipulated gap-graded granular particles on reinforcing foundation soil

  • Xin, Zhen H.;Moon, Jun H.;Kim, Li S.;Kim, Kab B.;Kim, Young U.
    • Geomechanics and Engineering
    • /
    • v.17 no.5
    • /
    • pp.439-444
    • /
    • 2019
  • It is generally known that high strength soil is indicative of well-graded particle size distribution. However, there are some special cases of firm ground despite poor grade distribution, especially a specific gap-graded soil. Based on these discoveries, this study investigated the development of an additive of gap-graded soils designed to increase soil strength. This theoretical concept was used to calculate the mixed ratio required for optimal soil strength of the ground sample. The gap-graded aggregate was added according to Plato's polyhedral theory and subsequently calculated ratio and soil strength characteristics were then compared to characteristics of the original soil sample through various test results. In addition, the underground stress transfer rate was measured according to the test conditions. The test results showed that the ground settlement and stress limit thickness were reduced with the incorporation of gap-graded soil. Further field tests would confirm the reproducibility and reliability of the technology by using gap-graded soil to reinforce soft ground of a new construction site. Gap-graded soil has the potential to reduce the construction cost and time of construction compared to other reinforcing methods.

Discrete element numerical analysis for simulating trapdoor tests to assess loosening earth pressure on tunnel linings

  • Chaemin Hwang;Junhyuk Choi;Jee-Hee Jung;Hangseok Choi
    • Geomechanics and Engineering
    • /
    • v.38 no.6
    • /
    • pp.571-581
    • /
    • 2024
  • Concrete linings in tunnels constructed by drilling and blasting such as NATM serve as a secondary support structure. However, these linings can face unexpected earth pressures if the primary support deteriorates or if ground conditions become unfavorable. It is crucial to determine the loosening earth pressure that allows the lining to maintain its structural integrity and prevent damage caused by this pressure. This study proposes a numerical model for simulating the trapdoor test and developing a method for calculating the loosening earth pressure. The discrete element method (DEM) was employed to describe the soil characteristics around the tunnel. Using this numerical model, a sequence of experimental trapdoor steps was simulated, and the loosening earth pressure was analyzed. Contact parameters were calibrated based on an analysis of a triaxial compression test. The reliability of the developed model was confirmed through a comparison between simulation results and laboratory test findings. The model was used to calculate the contact force applied to the trapdoor plate and to assess the settlement of soil particles. Furthermore, the model accounted for the soil-arching effect, which effectively redistributes the load to the surrounding areas. The proposed model can be applied to analyze the tunnel's cross-sectional dimensions and design stability under various ground conditions.

STRAIN ON THE LABIAL PLATES AROUND ABUTMENTS SUPPORTING REMOVABLE PARTIAL DENTURES WITH VARIOUS PROSTHETIC DESIGNS: AN IN VITRO STUDY

  • Kim, Seong-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.322-330
    • /
    • 2005
  • Statement of problem. In distal extension removable partial denture, the preservation of health of abutment teeth is very important, but abutment teeth are subjected to unfavorable stress. Purpose. The purpose of this study was to investigate the biomechanical effects of mandibular removable partial dentures with various prosthetic designs using strain gauge analysis. Material and methods. Artificial teeth of both canines were anchored bilaterally in a mandibular edentulous model made of resin. Bilateral distal extension removable partial dentures with splinted and unsplinted abutments were fabricated. Group 1 : Clasp-retained mandibular removable partial denture with unsplinted abuhnents Group 2 : Clasp-retained mandibular removable partial denture with splinted abutments by 6-unit bridge Group 3 : Bar-retained mandibular removable partial denture Strain gauges were bonded on the labial plate of the mandibular resin model, approximately 2 mm close to the abutments. Two vertical experimental loadings (100N and 200N) were applied subsequently via two miniature load cells that were placed at mandibular first molar regions. Strain measurements were performed and simultaneously monitored from a computer connected to data acquisition system. For within-group evaluations, t-test was used to compare the strain values and for between-group comparisons, a one-way analysis of variance (ANOVA) was used and Duncan test was used as post hoc comparisons. Results. Strain values increased as the applied load increased from 100N to 200N for all groups (p<.05). The strain values of group 1 and 2 were tensile under loadings. In contrast, strain values of group 3 were compressive in nature. Under 100N loading, group 1 showed higher strain values than group 3 in absolute quantity (p<.05). Under 200N loading, group 3 showed higher strain values than group 1 and 2 in absolute quantity (p<.05). Group 1 showed higher strain values than group 2 (p<.05). Conclusion. Splinting of two isolated abutments by bridge reduced the peri-abutment strain in comparison with unsplinted abutments. Strain of bar-retained removable partial denture increased much more as applied load increased, but was compressive in nature.