• Title/Summary/Keyword: Plate Type

Search Result 2,749, Processing Time 0.043 seconds

Displacement and stress distribution of the maxillofacial complex during maxillary protraction using palatal plates: A three-dimensional finite element analysis

  • Eom, Jusuk;Bayome, Mohamed;Park, Jae Hyun;Lim, Hee Jin;Kook, Yoon-Ah;Han, Seong Ho
    • The korean journal of orthodontics
    • /
    • v.48 no.5
    • /
    • pp.304-315
    • /
    • 2018
  • Objective: The purpose of this study was to analyze initial displacement and stress distribution of the maxillofacial complex during dentoskeletal maxillary protraction with various appliance designs placed on the palatal region by using three-dimensional finite element analysis. Methods: Six models of maxillary protraction were developed: conventional facemask (Type A), facemask with dentoskeletal hybrid anchorage (Type B), facemask with a palatal plate (Type C), intraoral traction using a Class III palatal plate (Type D), facemask with a palatal plate combined with rapid maxillary expansion (RME; Type E), and Class III palatal plate intraoral traction with RME (Type F). In Types A, B, C, and D, maxillary protraction alone was performed, whereas in Types E and F, transverse expansion was performed simultaneously with maxillary protraction. Results: Type C displayed the greatest amount of anterior dentoskeletal displacement in the sagittal plane. Types A and B resulted in similar amounts of anterior displacement of all the maxillofacial landmarks. Type D showed little movement, but Type E with expansion and the palatal plate displayed a larger range of movement of the maxillofacial landmarks in all directions. Conclusions: The palatal plate served as an effective skeletal anchor for use with the facemask in maxillary protraction. In contrast, the intraoral use of Class III palatal plates showed minimal skeletal and dental effects in maxillary protraction. In addition, palatal expansion with the protraction force showed minimal effect on the forward movement of the maxillary complex.

Sturdy for the development of Bridge plate of SEPTA Sliver Line V (미국 전동차 Manual bridge plate 에 대한 고찰)

  • Choi, Se-Jung;Yeom, Gyung-An
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.451-457
    • /
    • 2008
  • The aim of the sturdy is for the development of Bridge plate installing on floor for SETPA Sliver line V. SEPTA train have pocket sliding door which is similar with domestic trains. typically In the USA railway market, Portable type and standing type bridge plate used, easily hiding the bridge plate in stowed position and convenience operation, Bridge plate installed on floor is designed. relative regulation Like CFR APTA, and EN, UIC is reviewed and compared.

  • PDF

A COMPUTER ANALYSIS ON THE KOREAN CONSONANT SOUND DISTORTION IN RELATION TO THE PALATAL PLATE THICKNESS -Dentoalveolar and hard palatal consonant- (구개상의 두께에 따른 한국어 자음의 발음 변화에 관한 컴퓨터 분석 - 치조음, 경구개음-)

  • Woo, Yi-Hyung;Choi, Dae-Kyun;Choi, Boo-Byung;Park, Nam-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.25 no.1
    • /
    • pp.71-94
    • /
    • 1987
  • This study was carried out to investigate the sound distortion following the alternation of the palatal plate thickness. For this study, 2 healthy male subjects (24-year-old) were selected. Born in Seoul, they both spoke Seoul dialect. First, their sounds of /na(나)/, /da(다)/, /1a(라)/, /ja(자)/, /cha(차)/, /ta(타)/, without inserting plates were recorded, and then the sounds with palatal plates of different thickness were recorded, successively. The plate was fabricated in 3 types, each palatal thickness being 1.0mm, 2.5mm, dentoalveolar portion 2.5mm, other residual portion was 1.0mm, successively. Each type plates named B, C, D-type, in succession. Series of analysis were administered through Computer(16 bit) to analyze the sound distortions. These experiments were analyzed by the LPC (without weighting, pre-weighting, post-weighting) of the consonants, vowels portion, formant frequency of the vowels and word duration of the consonants. The findings led to the following conclusions: 1. There was no correlation of the distortion rate on the 2 informants. 2. Generally, vowels were not affected by the palatal plate thickness in the formant analysis, however, more distortion was detected in the LPC analysis, especially C, D-type plates. 3. Consonants distortion was more evident in the C, D-type plate. 4. The second formant was most disturbed and reduced in the all consonants with insertion of the palatal plate, especially C, D-type plate. 5. Word duration was shortened in the plate inserted(except /ja/, /cha/), especially C, D-type. 6. It was found that dentoalveolar, hard palatal sounds were severely distorted in plate inserted, and they were mainly affected by the dentoalveolar portion thickness. 7. There was correlation between palatal thickness and consonants quality.

  • PDF

Development of an image processing algorithm for the recognition of car types and number plates (차종, 번호판 위치 및 자동차 번호판 인식을 위한 영상처리 알고리즘개발)

  • 김희식;이평원;김영재
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1718-1721
    • /
    • 1997
  • An image processing algorithm is developed in order to recognize the type of cars, the position of a number plate and the characters on the plate. to recognize the type of cars, comparison of two images is used. One has a car image, the other is just a background image without car. After that recognition, a vertical line filter is used to find the location of the plate. Finally the simularity mehod is used to recognize the numbers on plates.

  • PDF

도로영상에서 차량 특성 곡선을 이용한 차종 구분 알고리즘 개발

  • 김희식;이호재;이평원
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.423-426
    • /
    • 1995
  • An image processing algorithm is developed in order to recognize the type of cars, the position of a number plate and the characters on the plate. To recognize the type af cars, comparison of two images is used. One has a car image, the other is just a background image without car. After that recognition, a vertical line filter is used to find the location of the plate. Finally the similarity method is used to recognize the numbers on the plates.

  • PDF

Heat Transfer Performance of Evaporator Used in a Domestic Refrigerator/Freezer Under Frosting Condition (착상을 고려한 가정용 냉동/냉장고 증발기의 열전달 성능)

  • Lee Jang-Seok;Lee Kwan-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.1
    • /
    • pp.62-70
    • /
    • 2005
  • In this study, the air-side heat transfer coefficients of several types of evaporators in the household freezer/refrigerators are investigated. The types considered in this work are: discrete flat plate fin-and-tube type(in-lined tube array), continuous flat plate fin-and-tube type(staggered tube array), and spine fin-and-tube type(in-lined tube array). The heat transfer correlations obtained from this study for each heat exchangers could expect heat transfer coefficients less than $5\%$ of errors. The result indicates that the air-side heat transfer performance of spine fin-and-tube type evaporator shows the highest value under dry conditions, but discrete flat plate fin-and-tube type evaporator shows the highest value among these three evaporators under frosting conditions.

A comparison of fixation methods using three-dimensional finite element analysis following anterior segmental osteotomy

  • Yun, Kyoung In;Park, Min-Kyu;Park, Myung-Kyun;Park, Je Uk
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.38 no.6
    • /
    • pp.332-336
    • /
    • 2012
  • Objectives: This study sought to evaluate fixation methods and determine the best method for the postoperative stabilization of maxillary osteotomy. For our analysis we performed a three-dimensional finite element analysis of stress distribution on the plate, screw, and surrounding bone, as well as displacement onto the plate. Materials and Methods: We generated a model using synthetic skull scan data; an initital surface model was changed to a solid model using software. Modified anterior segmental osteotomy (using Park's method) was made using the program, and four different types of fixation methods were used. An anterior load of 100 N was applied on the palatal surface of two central incisors. Results: The Type 1 (L-shaped) fixation method gave stresses of 187.8 MPa at the plate, 45.8 MPa at the screw, and 15.4 MPa at the bone around the plate. The Type 2 (I-shaped) fixation method gave stresses of 186.6 MPa at the plate, 75.7 MPa at the screw, and 13.8 MPa at the bone around the plate. The Type 3 (inverted L-shaped) fixation method gave stresses of 28.6 MPa at the plate, 29.9 MPa at the screw, and 15.3 MPa at the bone around the plate. The Type 4 (I-shaped) fixation method gave stresses of 34.8 MPa at the plate, 36.9 MPa at the screw, and 14.9 MPa at the bone around the plate. The deflection of the plates for the four fixation methods was 0.014 mm, 0.022 mm, 0.017 mm, and 0.018 mm, respectively. Conclusion: The Type 3 (inverted L-shaped) fixation method offers more stability than the other fixation methods. We therefore recommend this method for the postoperative stabilization of maxillary osteotomy.

A Study on the Heat Transfer from a Flat Plate and the Heat Transfer Enhancement by the Vortex Generator (평판에서의 열전달 및 와류발생기에 의한 열전달 촉진에 관한 연구)

  • Yoo, Seong-Yeon;Song, Si-Young;Park, Jong-Hark
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1447-1452
    • /
    • 2003
  • Vortex is very interesting flow phenomena on the heat transfer enhancement. In the present study, naphthalene sublimation technique is used to determine the average and local mass transfer coefficients on the flat plate with vortex generator. A parametric study with Reynolds number and angle of attack is carried out to investigate the heat transfer enhancement. The heat transfer coefficients on the flat plate with rectangular type and delta type vortex generator are compared with those of the flat plate without the vortex generator. Comparing heat transfer coefficients between rectangular type and delta type vortex generator, rectangular type vortex generator has much higher value than delta type vortex generator at the same condition.

  • PDF

Heat Transfer Performance of Plate Type Absorber with Surfactant

  • Yoon, Jung-In;M. M. A. Sarker;Moon, Choon-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.243-251
    • /
    • 2004
  • Absorption chiller/heater can utilize the unused energy of the daily life waste heat, the industry waste heat. the solar energy and the earth energy. These can contribute to energy savings. But the absorption chiller/heater has a demerit that the size of absorption chiller/heater is larger than that of the vapor compression type based on same capacity. In this study. the experimental apparatus of an absorber is manufactured as a plate. which is newly applied in an absorber. The experimental apparatus is composed of a plate type absorber. which can increase the heat exchange area per unit volume and thus facilitating to deeply investigate more detail features instead of that done by the existing type. i.e.. horizontal tube bundle type. The characteristics of heat transfer and refrigeration capacity are studied experimentally. The absorption enhancement by using surfactant is closely examined through the experiment and comparative figures are presented in quantitative and qualitative analysis.

Comparative Study for the Fixation Method in the Danis-Weber Type B Lateral Malleolar Fractures: An Antiglide Plate Fixation versus A Lateral Plate Fixation (Danis-Weber B형 족관절 외과 골절의 고정방법 비교연구 : Antiglide 금속판 고정술 대 외측 금속판 고정술)

  • Shin, Hun-Kyu;Choi, Jae-Yeol;Kang, Dong-Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.10 no.2
    • /
    • pp.201-206
    • /
    • 2006
  • Purpose: To evaluate the advantages of the antiglide plate fixation procedure for Danis-Weber type B lateral malleolar fractures of ankle compared to other methods of lateral plate fixation. Materials and Methods: We reviewed 70 cases that antiglide plate fixation and lateral plate fixation procedures were performed from Mar. 2001 through Mar. 2006. Of the total 70 cases, they were divided into two groups ; 22 cases were treated with the antiglide plate procedure (Group I) and 48 cases were treated with the lateral plate procedure (Group II). The results of the two groups were analyzed both radiographically and clinically using Ankle-Hindfoot scale of the American Orthopedic Foot and Ankle Society (AOFAS). Results: All fractures were healed at average of 8 weeks both radiographically and clinically. According to the Ankle-Hindfoot scale, all cases of Group I and 48 cases of Group II were above 80 points. 2 cases (9%) in Group I complained of peroneal tendinitis, while 19 cases (39%) in Group II showed skin irritation resulting from the screw or the plate. A total of 6 cases (27%) in Group I and 27 cases (55%) in Group II complained cosmetic problems. Conclusion: we concluded that the antiglide plate fixation for Danis-Weber type B lateral malleolar fractures is one of the good methods. But, further analysis will be need to find a solution for the peroneal tendinitis.

  • PDF