고무댐에 적용하기 위한 유리섬유보강 복합재료 클랩핑 플레이트의 내구 특성 (Durability Characteristics of Glass Fiber Reinforced Polymer Composite Clapping Plates for Application of Rubber Dam)

  • 이정우;박찬기;김종옥;이승기;김필식
    • 한국농공학회논문집
    • /
    • 제53권5호
    • /
    • pp.17-23
    • /
    • 2011
  • Steel clapping plate is used to connecting rubber body in rubber dam. However, once the steel clapping plate corrodes, it may cause faults, such as the same problems experienced by typical reinforcing steel. This study evaluated the applicability of glass fiber reinforced polymer composite(GFRP) clapping plate as a substitute for steel clapping plate. Absorption and load test were conducted to evaluate the decrease in durability of GFRP clapping plate exposed to deterioration environments. In the durability test results, the absorption rate of GFRP clapping plate was appeared as 0.6~1.0% in 50 day of immersion time. Also, the fracture load decreased with accelerated degradation environment exposure. Moreover, the absorption rate in GFRP clapping plate increased as degradation progressed, reducing the fracture load.

The patch tests and convergence for nonconforming Mindlin plate bending elements

  • Park, Yong-Myung;Choi, Chang-Koon
    • Structural Engineering and Mechanics
    • /
    • 제5권4호
    • /
    • pp.471-490
    • /
    • 1997
  • In this paper, the classical Irons' patch tests which have been generally accepted for the convergence proof of a finite element are performed for Mindlin plate bending elements with a special emphasis on the nonconforming elements. The elements considered are 4-node and 8-node quadrilateral isoparametric elements which have been dominantly used for the analyses of plate bending problems. It was recognized from the patch tests that some nonconforming Mindlin plate elements pass all the cases of patch tests even though nonconforming elements do not preserve conformity. Then, the clues for the Mindlin plate element to pass the Irons' patch tests are investigated. Also, the convergent characteristics of some nonconforming Mindlin plate elements that do not pass the Irons' patch tests are examined by weak patch tests. The convergence tests are performed on the benchmark numerical problems for both nonconforming elements which pass the patch tests and which do not. Some conclusions on the relationship between the patch test and convergence of nonconforming Mindlin plate elements are drawn.

GFRP 판을 전단보강재로 사용한 플랫 플레이트의 뚫림전단 성능 평가 (Evaluation of Punching Shear for Flat Plates Using GFRP Plate Shear Reinforcement)

  • 이영학;김민숙;황승연;최진웅;김희철
    • 한국전산구조공학회논문집
    • /
    • 제27권5호
    • /
    • pp.413-420
    • /
    • 2014
  • 본 논문에서는 유공형 형상의 GFRP 판으로 전단 보강된 플랫 플레이트의 전단거동을 실험을 통해 평가하였다. GFRP 판은 개구부가 있는 판의 형태로서 콘크리트와의 일체화 거동을 위하여 콘크리트에 매립하여 시공하였다. GFRP 판으로 전단 보강된 플랫 플레이트의 전단 성능 실험을 위하여 총 7개의 시험체에 대한 전단 실험을 수행하였다. 실험 변수로는 전단 보강량, 전단 보강 간격을 선정하였다. GFRP 판의 전단 보강량에 따른 비교결과, 전단 보강량이 증가할수록 전단강도도 증가하는 결과를 보여주었다. GFRP 전단 보강 간격에 따른 비교결과, 전단 보강 간격이 0.3d 일 때 가장 높은 전단강도를 확인하였다. 실험결과를 바탕으로 KCI에서 제시하고 있는 전단강도식을 수정하여 GFRP 판에 적용이 가능한지 평가하였다.

Cooler와 Heater를 이용한 반도체 시험용 Plate의 온도제어 (Temperature Control of a Test Plate for Semiconductor Using a Cooler and a Heater)

  • 이호준;전창완;심용재;심운용
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.320-320
    • /
    • 2000
  • In this paper, a temperature controller of a test plate for semiconductor is developed using LQG/LTR methodology. The liquid is heated or cooled in a tank by a heater of a cooler. The controller controls the flow of heated or cooled liquid in the plate by controling an electronic valve. The developed controller is applied to the plate designed for function test of a semiconductor under high or low temperature environment. As a result, control using the heater and the cooler together shows better control performance than using the heater or the cooler separately.

  • PDF

강판 휨보강된 철근 콘크리트보의 구조적 거동 (Structural Behavior of RC Beam Strengthened with Steel Plate)

  • 오병환;강동욱;조재열;채성태;이명규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.598-604
    • /
    • 1997
  • In recent years, strengthening by epoxy-bonded steel plates, carbon fiber sheets, aramid fiber sheets and so on, is spotlighted. Among them, the method using steel plates is most widely applied. Most studies have dealt with strengthening by epoxy-bonded steel plates. However the actual behavior of strengthened RC beams are not well established. Particularly, the studies on the separation load thar affects failure load of the beam are relatively insufficient. In this study, test parameters are the magnitude of pre-load, plate length, plate thickness, existence and spacing of anchor bolt, the number of plate layer and the height of side strengthening, 17reinforced concrete beams are strengthened by steel plates according to test parameters. Deflection, failure load, strains of reinforcing bar, concrete and plate are measured from tests(4 points loading). The failure mode, and separation load are analyzed from these measured data. The difference between Robert's theory and test results is discussed, and the prediction equation for separation load in the case of rip off is proposed.

  • PDF

On the material properties of shell plate formed by line heating

  • Lim, Hyung Kyun;Lee, Joo-Sung
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제9권1호
    • /
    • pp.66-76
    • /
    • 2017
  • This paper is concerned with investigating the plastic material properties of steel plate formed by line heating method, and is aimed at implementing more rational design considering the accidental limit states such as collision or grounding. For the present study, line heating test for marine grade steel plate has been carried out with varying plate thickness and heating speed, and then microscopic examination and tensile test have been carried out. From the microscopic, it is found that the grain refined zones like ferrite and pearlite are formed all around the heat affected zone. From the tensile test results, it is seen that yield strength, tensile strength, fracture strain, hardening exponent and strength coefficient vary with plate thickness and heat input quantity. The formulae relating the material properties and heat input parameter should be, therefore, derived for the design purpose considering the accidental impact loading. This paper ends with describing the extension of the present study.

도축돈의 혈청, 뇨 및 근육에서 sulfamethazine 잔류 조사 (Detection of residual sulfamethazine in serum, urine and muscle of slaughtered pigs)

  • 추금숙;오언평;최인열;송희종;채효석
    • 한국동물위생학회지
    • /
    • 제20권2호
    • /
    • pp.161-168
    • /
    • 1997
  • This study was undertaken to determined the sulfamethazine residues In urine, serum and muscle of slaughtered pigs(n: 230) by the method of TLC, EEC-4-plate and HPLC. 1. Inhibition diameter characteristics of reference bacterial substance by EEC-4-plate method and antibacterial inhibition zone was appeared sulfonamides in BS pH 7.2 2. Residual sulfamethazine was detceted from 7 serum(3.04%) and 10 urine(4.35%) by TLC test and concentration of residues was higher In urine than serum. 3. Residual sulfamethazine was detected from 9 muscle(3.91%) by EEC-4-plate method. 4. Positive samples by TLC test and EEC-4-plate method were exceed 0.1ppm quantitative analysis from 7 muscle(3.04%).

  • PDF

CFT기둥-RC 무량판 접합부의 펀칭전단강도 및 거동 (Punching Shear Strength and Behavior of CFT Column to RC Flat Plate connections)

  • 이철호;김진원;이승동;안재권
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.168-179
    • /
    • 2006
  • This paper summarizes full-scale test results on CFT column-to-flat plate connections subjected to gravity loading. CFT construction has gained wide acceptance in a relatively short time in domestic building construction practice due to its various structural and construction advantages. However, efficient details for CFT column to flat plate connections have not been proposed yet. Based on the strategies that maximize economical field construction, several connecting schemes were proposed and tested. Test results showed that the proposed connections can exhibit punching shear strength and connection stiffness exceeding those of R/C flat plate counterparts. A semi-analytical procedure is presented to model the behavior of CFT column-to-flat plate connections. The five parameters to model elastic to post-punching catenary action range are calibrated based on the limited test data of this study. The application of the proposed modeling procedure to progressive collapse prevention design is also illustrated.

  • PDF

Deformation Behaviour of Metamorphic Tuff from Plate Loading Test

  • Lee, Young-Nam;Suh, Young-Ho;Kim, Dae-Young
    • 한국지반공학회지:지반
    • /
    • 제13권3호
    • /
    • pp.87-100
    • /
    • 1997
  • 본 논문에서는 건설 중인 국내의 한 지하 원유비축기지의 기반암인 변성응회암의 변형특성을 파악하고 변형계수를 결정하기 위하여 평판재하시험 및 불연속체 수치해석을 수행하였다. 평판 재하시험에서는 직경 1m의 flat jack을 이용하여 최대 14MPa의 하중을 기반암에 가하고 이에 대한 반력장치로서 록 앵커 시스템을 이용하였다. 본 시험으로부터 얻어진 변형계수 결과치는 실내시험, 이축압축시험, 공내재하시험 등에서 구한 값들과 비교되었다. 그 결과, 평판재하시험에서 구한 변형계수는 신선한 암편 탄성계수의 약 50%정도인 것으로 나타났으며, 현지 기반암의 변형계수는 암반에 분포하는 절리들로 인하여 25-350pa의 범위에 속하는 것으로 판정되었다. 또한 시험 부지내에 분포하는 여러 불연속면들을 고려한 불연속체 해석을 실시하여 평판재 하시험을 모사하고 절리들이 암반의 변형특성에 미치는 영향을 분석하였다.

  • PDF

탄성 의치상 이장재의 접착력에 관한 연구 (A STUDY ON THE BONDING STRENGTH OF RESILIENT DENTURE LINERS)

  • 이상훈;정재헌
    • 대한치과보철학회지
    • /
    • 제30권3호
    • /
    • pp.411-436
    • /
    • 1992
  • The purpose of this study was to assess the adhesion of resilient denture liners (such as, heat-cured silicone molloplast B,cold- cured silicone Mollosil) to polymethyl metacrylate (K-33) and metal (Megalloy) in the laboratory by peel test. The resilient denture lines were processed according to manufactures instruction, onto prepared specimens(original resin base plate, rough resin base plate, stippled metal plate, mesh metal plate ) 75mm long and 25m wide. And then, the peel test was performed by instron. The results were as follows : 1. The bonding strength of Mollosil was stronger than that of Molloplast B except the specimen of stippled metal plate. 2. The tensile strength of Mollosil was weaker than that of Molloplast Bas tearing of Mollosil was occured in the peel test. 3. Mesh metal plate had the highest bonding strength in the case of Molloplast B and Mollosil. But stippled metal plate have high bonding strength in the case of Molloplast B and have the lowest bonding strength in the case of Mollosil. 4. The bonding strength of rough resin base plate was stronger than that of original resin base plate in the case of Molloplast B and Mollosil. 5. The bonding strength of metal plates was stronger than that of resin base plates in the case of Molloplast B and Mollosil except the case of bonding strength between the stippled metal plate and Mollosil. 6. It seems that the Increase of surface and retention form of metal plate and resin base plate produces higher physical bonding strength.

  • PDF