• Title/Summary/Keyword: Plate Test

Search Result 3,140, Processing Time 0.037 seconds

Flutter suppression of long-span suspension bridge with truss girder

  • Wang, Kai;Liao, Haili;Li, Mingshui
    • Wind and Structures
    • /
    • v.23 no.5
    • /
    • pp.405-420
    • /
    • 2016
  • Section model wind tunnel test is currently the main technique to investigate the flutter performance of long-span bridges. Further study about applying the wind tunnel test results to the aerodynamic optimization is still needed. Systematical parameters and test principle of the bridge section model are determined by using three long-span steel truss suspension bridges. The flutter critical wind at different attack angles is obtained through section model flutter test. Under the most unfavorable working condition, tests to investigate the effects that upper central stabilized plate, lower central stabilized plate and horizontal stabilized plate have on the flutter performance of the main beam were conducted. According to the test results, the optimal aerodynamic measure was chosen to meet the requirements of the bridge wind resistance in consideration of safety, economy and aesthetics. At last the credibility of the results is confirmed by full bridge aerodynamic elastic model test. That the flutter reduced wind speed of long-span steel truss suspension bridges stays approximately between 4 to 5 is concluded as a reference for the investigation of the flutter performance of future similar steel truss girder suspension bridges.

A serological survey on large outbreak of bovine brucellosis in dairy farm (부루셀라병 다두이환 목장의 혈청항체가 조사)

  • 김상윤;김정화;김대원
    • Korean Journal of Veterinary Service
    • /
    • v.22 no.2
    • /
    • pp.159-167
    • /
    • 1999
  • This survey was conducted for the serological confirmation on large outbreak of bovine brucellosis in two dairy farms. Serological tests were performed by the plate agglutination test, tube agglutination test, enzyme linked immunosorbent assay(ELISA), complement fixation, ,test(CFT) and rose bengal plate test(RBPT). Total 200 heads(134 heads in farm A and 66 heads in farm B) were tested. The primigravida and positive group have been raised separately in the farm A and both group have been raised together in the farm B.. The result were summarized as follows ; 1. Positive ratios in positive herds of farms by the tube agglutination test were 68.3% in farm A and 53.2% in farm B. 2. Seroconversion to brucella was observed in the primigravidas group in farm B, but was not observed in the primigravidas group in farm A. 3. All calves born in positive herd were serologically negative at time of test. 4. Positive ratio of ELISA in farm A was higher than that of tube agglutination test. 5. Number of positive reactors by the CFT, RBPT in farm A were equal to those of tube agglutination test.

  • PDF

A Study on Characteristic Analysis of C-Plate Cover and Examination of Weak Parts (C-Plate 커버의 구조해석 및 취약부 규명)

  • 김옥구;송준엽;강재훈;박화영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.373-377
    • /
    • 2003
  • Recently, advanced manufacturing systems with high speed and intelligence have been developed for the betterment of machining ability. In this case, reliability prediction work with motion characteristic evaluation of sliding cover(C-plate, Bellows, etc) has also important role from design procedure to manufacturing and assembly process. Accordingly in this study, H/W test-bed system for reliability evaluation of sliding cover has been developed to obtain proper reference data for design of new model, prevention trouble (failure mode), and improvement of quality and lift cycle extremely for advanced mother machinery.

  • PDF

Development of a Plate-Fin Type Gas Turbine Recuperator

  • Kwak Jae-Su;Yang In-Young
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.7
    • /
    • pp.1068-1076
    • /
    • 2006
  • A plate-fin type recuperator for a gas turbine/fuel cell hybrid power generation system was designed, manufactured, and tested. Performance analysis shows that the performance of the system is directly affected by the performance of the recuperator. Therefore, the recuperator should be designed and manufactured carefully, and its performance should be tested and verified before it is integrated into the system. In this paper, the developing procedure including designing, manufacturing, and testing of a cross flow plate-fin type recuperator was presented. Performance test results showed that the design requirements of the recuperator were almost satisfied. Based on the test results, improved design to reduce the size of the recuperator was suggested.

Stress intensity factors for an interface crack between an epoxy and aluminium composite plate

  • Itou, S.
    • Structural Engineering and Mechanics
    • /
    • v.26 no.1
    • /
    • pp.99-109
    • /
    • 2007
  • A cracked composite specimen, comprised of an epoxy and an aluminium plate, was fractured under a tensile load. In this paper, two crack configurations were investigated. The first was an artificial center crack positioned in the epoxy plate parallel to the material interface. The other was for two edge cracks in the epoxy plate, again, parallel to the interface. A tensile test was carried out by gradually increasing the applied load and it was verified that the cracks always moved suddenly in an outward direction from the interface. The d/a ratio was gradually reduced to zero, and it was confirmed that the maximum stress intensity factor value for the artificial center crack, $K_{{\theta}{\theta}}^{max}$, approached that of an artificial interface crack,$K_{{\theta}{\theta}}^{ifc\;max}$ (where: 2a is the crack length and d is the offset between the crack and interface). The same phenomenon was also verified for the edge cracks. Specifically, when the offset, d, was reduced to zero, the maximum stress intensity factor value, $K_{{\theta}{\theta}}^{max}$, approached that of an artificial interface edge crack.

A Numerical Study on the Shock Resistance Test of Aluminium 2519 Plate (알루미늄 2519 판재의 충격저항성 평가에 대한 수치 해석적 연구)

  • Koo Man-Hoi;Woo Ho-Gil
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.7 no.3 s.18
    • /
    • pp.11-20
    • /
    • 2004
  • In this paper, the acceptance criteria(Striking Velocities) for the A12519 weldments have been developed. Dynamic impact simulation of A12519 plate was achieved by using LS-DYNA, and predict the projectile velocity and the crack length. Also, Ballistic impact tests of A12519 plate have been performed, and compared with analysis results. Critical velocities of A12519 plate were acquired respectively, and striking velocities of A12519 weldments were calculated. Present work data will be used by basic data in ballistic impact test for A12519 weldments.

Structural Performance of Super-Deck Plate Slab System with Truss Type Bar (트러스근을 사용한 슈퍼데크 플레이트의 구조성능평가)

  • Kim, Seong-Soo;Kim, Sang-Shik;Lee, Woo-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.2
    • /
    • pp.193-199
    • /
    • 2003
  • This paper presents the results of an experimental research project on 7 Super Deck Plates with continuous or simple beam types. The test parameters included the distance of truss, depth of deck plate and the type of beam. The test results are as follows ; When thickness of deck plate was increased, maximum strength was improved When the distance of truss bar was reduced from 20cm to 15cm, the mean value of maximum load was increased to 1.21 times. Continuous beam shown superior to simple beam, such as 5.03 times high strength, low deflection at yield point.

The Experimental Study of Radiant Cooling Test System under Different Covers (복사냉각 시스템에서 커버의 영향)

  • Byun, Ki-Hong;Smith, Theodore F.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.11
    • /
    • pp.797-802
    • /
    • 2007
  • The effects of window cover on the performance of the plate type radiant cooling test system are studied. The cover materials tested are 2mm, 1mm, 0.7mm glass, Cokin 007 filter, and PVC film. The measurements are performed during the September nights of 2005 at the rooftop of the building in Seoul. The equivalent height of the building is about a building with twelve floors. The radiant cooling performance of the black painted and aluminum film coated plate are compared under no cover condition. Also the results are compared when the system has cover over the plate. In general, the covers reduce the radiant cooling temperature differences during the nighttime. Among these covers, the PVC film cover shows the best performance. In some cases, the plate with PVC film cover shows lower temperatures than the system without cover.

A Study on Fatigue Behavior near the Cover Plate Weldments in the Plate Girder (강판의 덮개판 용접부에서의 피로거동에 관한 연구)

  • Jung, Young-Hwa;Kim, Ik-Gyeom;Kim, Yon-Kyung
    • Journal of Industrial Technology
    • /
    • v.18
    • /
    • pp.461-468
    • /
    • 1998
  • Service life of steel bridges depends on fatigue and corrosion. Fatigue damage result from stress concentration and initial defects in the joint of secondary member such as weldments. The objective of this study is to estimate fatigue strength of the cover plate weldments in the plate girder. For this study, fatigue tests, static tests and finete element method has been performed respectively from these results. It was found that our test results were well agreed with other test results and satisfied with the fatigue criterion of AASHTO, JSSC and EUROCODE specifications.

  • PDF

Development of Metallic Bipolar Plate Material with W-addition in Austenitic Stainless Steel for PEMFC Environment

  • Kim, Kwang Min;Koh, Sung Ung;Kim, Kyoo Young
    • Corrosion Science and Technology
    • /
    • v.5 no.5
    • /
    • pp.153-159
    • /
    • 2006
  • Austenitic stainless steels with addition of various amounts of Mo and W were evaluated in terms of corrosion and contact resistance to determine optimum alloy composition of metallic bipolar plate for PEMFC. The corrosion property was evaluated by both acid fume exposure test at $130^{\circ}C$ and by electrochemical polarization tests in $H_3PO_4$ solution at $80^{\circ}C$. Austenitic stainless steel with proper amount of Mo and W demonstrated not only good corrosion resistance but also low contact resistance. Analyses on the passive film show that partial substitution of Mo by W enhances passive film stability and repassivation property. Test results suggest that austenitic stainless steel with 2 wt%Mo and 4 wt%W has optimum composition for metallic bipolar plate used in PEMFC.