• 제목/요약/키워드: Plate Fins

Search Result 84, Processing Time 0.021 seconds

Design of Variable Power Distributor and Waveguide Connecting Structure for Wireless Microwave Power Transmission in a Building (실내 마이크로파 배전 전송계를 위한 가변전력분배기와 도파관의 결합구조 설계)

  • Choi, Young-Kyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1477-1482
    • /
    • 2012
  • This paper deals with a new variable microwave power distributor and a connector between a deck plate and a input power waveguide for indoor microwave wireless power transmission. We design a new type connector built in the 3-stage coaxial line structure, and calculate the return loss of the connector at 2.45GHz. Newly designed connector shows the excellent return loss performance less than -30dB at the operating frequency of 2.45GHz. And we show a power distributor in which the dividing ratio of the power is controlled mechanically by three rotary fins. The distributor can control the dividing power from 4.5% to 58% with the variance of 5% output power. The experimentally tested results of the distributor are good agreement with the simulation within the return loss of 1%.

Computer Simulation on the Performance of Air-Cooled Condenser for an Absorption Heat Pump (흡수식 열펌프용 공냉식 응축기의 성능특성에 관한 시뮬레이션)

  • 박윤철;민만기
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.8
    • /
    • pp.1999-2011
    • /
    • 1995
  • Computer simulation was conducted to study performance characteristics of air-cooled condenser of a double effect absorption heat pump with variations of saturation pressures and mass flow rates of the refrigerant ; volume flow rates, relative humidities and temperatures of the air The vertically installed condenser had the staggered tube array with continuous plate fins of wavy type. When the saturation pressure of the condenser was decreased from 760 torr to 20 torr, heat transfer rates and condensing rates of refrigerant were decreased. If excess refrigerant flows in the condenser, the pressure and saturation temperature of the condenser were increased which makes the refrigerating capacity of an absorption heat pump reduced.

Analysis for Air-Side Convective Heat Transfer Characteristics in Compact Heat Exchangers (밀집형 열교환기 내 공기 측 대류열전달특성)

  • Moh, Jeong-Hah;Lee, Sang-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1443-1448
    • /
    • 2009
  • Numerical analysis has been carried out to investigate air-side convective heat transfer characteristics in compact heat exchangers with continuous plate fins. Simulation results such as air flow and temperature distributions are presented, and heat transfer characteristics are compared for various inlet conditions. Results from various turbulence models are also compared for applicability. There is large difference between the local heat transfer coefficient distributions along the cylinder wall for circular tubes. Colburn j factors from the calculated results of circular and flat tubes in the heat exchangers are compared for various Reynolds number. The predicted results in this study can be applied to the optimal design of air conditioning system. with compact heat exchanger.

  • PDF

Heat Transfer Enhancement by the Combined Effect of Louver Angle and Angle of Attack of Vertex Generator (와류발생기의 충돌각과 루버각의 상호작용에 의한 열전달촉진)

  • 박병규;정재동;이준식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.6
    • /
    • pp.477-484
    • /
    • 2002
  • A numerical investigation of the performance of the plate heat exchanger with rectangular winglet is conducted to examine the combined effect of vortex generator and louver fins. Velocity and temperature fields and spanwise averaged Nu and friction factor are presented. Enhancement of heat transfer and flow loss penalty is evident. A Parametric study of three factors (Re, angle of attack and louver angle) with levels of 5 (Re= 300, 500, 700, 900, 1100), 4($\alpha=15^{\circ}, 30^{\circ}, 45^{\circ}, 90^{\circ},$), and 4($\beta=0^{\circ}, 15^{\circ}, 30^{\circ}, 45^{\circ}$), respectively, indicates the performance defined by the ratio of heat transfer enhancement to flow loss penalty shows monotonic behavior for each parameter alone but the interactions between parameters is found to be considerable effect on the performance of heat exchanger and should be considered in design. The effect of stamping is also examined.

Desktop PC CPU Cooling System Design and Analysis

  • Choi, Jee-Hoon;Yoo, Jung-Hyun;Seo, Min-Whan;Kang, Shin-Jae;Kim, Chul-Ju
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.601-604
    • /
    • 2008
  • Desktop PC CPUs have been significantly required to be the necessity of thermal management while they have satisfied the extensive data and graphic processing requirements. So the cooling systems assembled with heat pipes embedded in a metal cooling plate, and fins are widely used in the desktop PC markets. Due to a number of demands such as the confined space of desktop PCs, higher heat density of CPUs, and acoustic noise, however, there is the main drive to improve continuously cooling systems. This paper presents the flow and thermal behavior of the cooling system by using the computational fluid dynamics(CFD) code.

  • PDF

Development of an Anti-Seasickness Bed used in Vessel

  • Kim, Young-Bok;Jeong, Ji-Hyun
    • Journal of Power System Engineering
    • /
    • v.18 no.4
    • /
    • pp.112-116
    • /
    • 2014
  • Roll and pitching motions of a vessel can seriously degrade the performance of mechanical systems and the effectiveness of personnel. Many studies on roll stabilization and trimming control system design have focused on stabilizing the vessel through the use of fins, tanks, rudders and flaps. However the ultimate objective of such approaches must be to improve boarding sensitivity. This paper presents an anti-seasickness bed that consists of a rotator and bearing system that does not make use of electric power. The advantages of this system are its simple construction, usefulness, and safe operation. In this study, the rotation angles of the upper plate of a bed according to change weight of the rotator have been calculated to determine the stability. As a result, it can be concluded that proposed stabilizing bed can be of practical use in the field.

Performance Comparison of 7mm Fin-Tube Heat Exchangers for Various Design Conditions (설계 조건에 따른 7mm 직경 핀-관 열교환기의 성능비교)

  • Chang, Keun-Sun;Kim, Hyuk;Hong, Seok-Ryul;Kim, Young-Jae
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.633-638
    • /
    • 2006
  • This study presents the air side heat transfer and friction characteristics of fin-tube heat exchangers with various fin types. A total of 8 samples of heat exchangers are tested. Fin patterns tested are slit, louver and plate fins. Each fin type has three cases of number of tube rows(N=1, 2, 3) and two different fin pitches. The results are plotted in terms of Colburn j-factor and friction factor f with respect to Reynolds number in the range of 200 to 510.

  • PDF

Thermal Analysis of the Heat Sink Performance using FEM (유한 요소법을 이용한 히트싱크의 성능평가를 위한 열해석 연구)

  • Lee, Bong-Gu;Lee, Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.9
    • /
    • pp.5467-5473
    • /
    • 2014
  • This study examined the numerical analysis results with respect to the thermal behavior of a natural convection cooled pin-fin heat sink. The heat sink consisted of pin fins integrated with plate fins. The heat sinks were designed with two different types to fit the limited internal space. The two types of heat sinks designed were analyzed using the ANSYS software package, and the numerical analysis results were compared with the cooling performance of the two types of heat sinks. The results of the simulation were analyzed according to the temperature distribution and air flow characteristics, heat flux etc. This study examined the correlation of the cooling performance with the heat sink internal structure and fin shape. FEM (Finite Element Method) confirmed the cooling performance of heat sink type A under natural convection conditions as the best results. The results of the numerical simulation showed that the heat sink type A shape showed an approximately 70 percent better heat transfer rate with natural convection than that of type B.

Experimental Study of a Recuperator with Offset Strip Fins (오프셋 스트립 휜을 가지는 리큐퍼레이터에 대한 실험적 연구)

  • Kim, Taehoon;Do, Kyu Hyung;Han, Yong-Shik;Choi, Byung-Il;Kim, Myungbae
    • Journal of Energy Engineering
    • /
    • v.24 no.2
    • /
    • pp.72-78
    • /
    • 2015
  • In the present study, a recuperator to improve the thermal efficiency of a micro gas turbine is considered. The counter flow plate-fin heat exchanger with offset strip fins is chosen as the type of the recuperator. From the optimization study as varying design parameters of the recuperator determined from the ideal cycle analysis, the internal structure of the recuperator is determined. The recuperator is made from stainless steel 304. In order to evaluate performance of the recuperator, experimental investigation is performed. The effects of inlet temperature of hot-side of the recuperator on the thermal performance of the recuperator are investigated. As a result, effectiveness of the recuperator obtained from the experiments is well consistent with that obtained from the correlations.

Computational study of orientation effects on thermal performance of natural convection cooled lightweight high performance hollow hybrid fin heat sinks (자연대류 냉각되는 경량고성능 할로우 하이브리드 휜 히트싱크의 열성능에 대한 방향 영향의 전산연구)

  • Effendi, Nico Setiawan;Kim, Kyoung-Joon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.9
    • /
    • pp.786-790
    • /
    • 2016
  • This paper discusses numerically explored orientation effects on the thermal performance of hollow hybrid fin heat sinks (HHFHSs) under natural convection. A HHFHS consists of an array of hollow pin fins concatenated with plate fins and having perforations near the fin bases. Orientation effects on the footprint-based and mass-based thermal performance of the HHFHS were numerically studied for orientation angles ranging from $0^{\circ}$ to $180^{\circ}$. The performance of the HHFHS was compared with that of a pin fin heat sink (PFHS) having similar physical parameters. The results show that the thermal resistance of the HHFHS did not vary considerably from $0^{\circ}$ to $45^{\circ}$. The thermal resistance increased from $45^{\circ}$ to $90^{\circ}$, reached its maximum at $90^{\circ}$, and decreased consistently from $90^{\circ}$ to $180^{\circ}$. Dissimilar behaviors of the thermal resistance of the HHFHS vs. the PFHS resulted mainly from the effect of heat pumping induced by the internal flows of the hollow fins. Despite various orientations, the mass-based thermal resistance of the HHFHS was found to be nearly 30% smaller than that of the PFHS. This result shows the feasibility of the HHFHS for the lightweight thermal management of electronics under natural convection.