• Title/Summary/Keyword: Plastic disk

Search Result 72, Processing Time 0.04 seconds

Mechanical Behavior Evaluation and Structural Analysis of 316 Stainless Steel at High Temperature (316 스테인리스강의 고온 물성 연구 및 구조 평가)

  • Rhim, Sung-Han;Lee, Kwang-Ju;Kim, Jin-Bae;Yang, In-Young
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.181-184
    • /
    • 2008
  • Austenitic stainless steel is used as high temperature components such as gas turbine blade and disk because of its good thermal resistance. In the present investigation, tensile and low cycle fatigue behavior of 316 stainless steel was studied at wide temperature range $20^{\circ}C{\sim}750^{\circ}C$. In the tensile tests, it was shown that elastic modulus, yield strength, ultimate tensile strength decreases when temperature increased. The effect on fatigue failure of the parameters such as plastic strain amplitude and plastic strain energy density was also investigated. With the experimental results, a structural analysis of turbine blades of 316 stainless steel were carried out.

  • PDF

Comparative Efficacy for Dressing Methods of Iodine on Infected Full Thickness Skin Wound in the Mouse (흰 쥐의 감염된 전층피부 결손에서 Iodine의 드레싱 방법에 따른 창상치유 효과의 비교)

  • Lee, Jong-Hoon;Kim, Yo-Han;Min, Kyung-Hee;Hong, Sung-Hee;Lee, Won-Mi;Chae, Jeong-Don;Jun, Jin-Hyun
    • Archives of Plastic Surgery
    • /
    • v.37 no.3
    • /
    • pp.213-219
    • /
    • 2010
  • Purpose: Iodine has been used for the prevention or management of wound infection as a topical agent. Although iodine was widely used mainly by Betadine$^{(R)}$ and cadexomer iodine, there was no comparative study on the efficacies of dressing methods of iodine. And also it's wound healing effect was not yet clear. The purpose of this study is to compare antibacterial effects and wound healing effects associated with various dressing methods of iodine on infected full thickness skin defect in the mouse. Methods: One full thickness skin defects in the mice (n=60) were developed on the back and left open for twenty-four hours. Sixty mice were divided into four groups : group S (dressing with Betadine$^{(R)}$ soaking, n=15), group T (dressing with Betadine$^{(R)}$ topping, n=15), group I (dressing with Iodosorb$^{(R)}$, n=15), group G (control group, dressing with dry gauze, n=15). The size of the wound defects and the grades of wound healing were evaluated in 4, 7, 10 days, and antibacterial effect was evaluated with restricted zone in Mueller Hinton agar by disk diffusion method. Results: After the wound was left open for twenty-four hours, many Staphylococcus aureus were cultured. The wound defect size was decreased in order of Betadine$^{(R)}$ soaking, Iodosorb$^{(R)}$, Betadine$^{(R)}$ topping and gauze dressing group in all days, but difference among experimental groups was not statistically significant. The grade score of wound healing was increased in order of Betadine$^{(R)}$ soaking, Iodosorb$^{(R)}$, Betadine$^{(R)}$ topping and gauze dressing group, and the difference was statistically significant. Antibacterial effect for S. aureus was increased in order of Iodosorb$^{(R)}$, Betadine$^{(R)}$ soaking, Betadine$^{(R)}$ topping and gauze dressing group, and the difference was statistically significant. Conclusion: Selection of the effective dressing method of iodine for infected wounds remains a controversial decision. According to this study, Iodosorb$^{(R)}$ may be most effective method for antibacterial effect and Betadine$^{(R)}$ soaking may be most effective method for infected wound healing. However, further study is necessary to evaluate the clinical efficacy of dressing methods of iodine and to search for the mechanisms that explain their effects.

Comparison of Antibacterial Ointments for Antibacterial and Wound Healing Effect on Infected Full Thickness Skin Defect in the Mouse (흰 쥐의 감염된 전층피부결손에 대한 항균연고들의 항균효과 및 창상치유 효과의 비교)

  • Jeon, So-Yeon;Lee, Jong-Hoon;Min, Kyung-Hee;Hong, Sung-Hee;Lee, Won-Mi;Chae, Jeong-Don;Jun, Jin-Hyun
    • Archives of Plastic Surgery
    • /
    • v.37 no.2
    • /
    • pp.115-121
    • /
    • 2010
  • Purpose: Many topical agents had been used for contaminated wound treatment. Although antimicrobial ointments were widely used as topical agents, their comparative antibacterial and wound healing effects were largely unreported. The purpose of this study was to compare antibacterial effects and wound healing effects of common topical ointments on infected full thickness skin defect in the mouse. Methods: One full thickness skin defects in the mice (n=60) were developed on the back and left open for twenty-four hours. Sixty mice were divided into four groups: group B (dressing with Bactroban$^{(R)}$, n=15), group I (dressing with Iodosorb$^{(R)}$, n=15), group T (dressing with Terramycin$^{(R)}$, n=15), group G (control group, dressing with dry gauze, n=15). The size of wound defects and the grades of wound healing were evaluated at 4, 7, 10 days, and antibacterial effect was evaluated with restricted zone in Mueller Hinton agar by disk diffusion method. After the wound was left open for twenty-four hours, many Staphylococcus aureus was cultured. The wound defect size was decreased in order of Bactroban$^{(R)}$ (B), Iodosorb$^{(R)}$ (I), Terramycin$^{(R)}$ and gauze dressing group in all days, but difference among experimental groups was not statistically significant. The grade score of wound healing was increased in order of Bactroban$^{(R)}$, Iodosorb$^{(R)}$, Terramycin$^{(R)}$ and gauze dressing group, and the difference was statistically significant. Antibacterial effect for was increased in order of Bactroban$^{(R)}$, Iodosorb$^{(R)}$, Terramycin$^{(R)}$ and gauze dressing group, and the difference was statistically significant. Conclusion: Topical antimicrobial ointments application was effective against wound infections by S. aureus. Bactroban$^{(R)}$ may be an optimal topical treatment for infected wounds according to this study. However, further study is necessary to evaluate the clinical efficacy of antimicrobial ointments and to search for the mechanisms that explain their effects.

Assessment of Natural Radiation Exposure by Means of Gamma-Ray Spectrometry and Thermoluminescence Dosimetry (감마선분광분석(線分光分析) 및 열형광검출법(熱螢光檢出法)에 의한 자연방사선(自然放射線)의 선량측정연구(線量測定硏究))

  • Jun, Jae-Shik;Oh, Hi-Peel;Choi, Chul-Kyu;Oh, Heon-Jin;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.10 no.2
    • /
    • pp.96-108
    • /
    • 1985
  • A study for the assessment of natural environmental radiation exposure at a flat and open field of about $10,000m^2$ in area in CNU Daeduk campus has been carried out by means of gamma-ray scintillation spectrometry and thermoluminescence dosimetry for one year period of time from October 1984. The detectors used were 3'${\phi}{\times}$3' NaI(T1) and two different types of LiF TLD, namely, chip sealed in plastic sheet which tightly pressed on two open holes of a metal plate and Teflon disk. Three 24-hour cycles of in-situ spectrometry, and two 3-month and one 1-month cycles of field TL dosimetry were performed. All the spectra measured were converted into exposure rate by means of G(E) opertaion, and therefrom exposure rate due to terrestrial component of environmental radiation was figured out. Exposure rate determined by the spectrometry was, on average, $(10.54{\pm}2.96){\mu}R/hr$, and the rates of $(12.0{\pm}3.4){\mu}R/hr$ and $(11.0{\pm}3.6){\mu}R/hr$ were obtained from chip and disk TLD, respectively. Fluctuations in diurnal variation of the exposure rate measured by the spectrometry were noticeable sometime even in a single cycle of 24 hours. It is concluded that appropriately combined use of TLD with iu-sitn gamma-ray spectrometry system can give more accurate and precise measure of environmental radiation exposure, and further study for more adequate and sensitive TLD for environmental dosimetry, including improvement and elevation of accuracy in data assessment through inter-laboratory or international intercomparison is necessary.

  • PDF

HISTOPATHOLOGICAL STUDY ON CARDIOMYOPATHY IN EXPERIMENTALLY INDUCED DIABETIC RATS (실험적으로 유도된 당뇨백서의 심근병증에 관한 조직병리학적 연구)

  • Ahn, Jin-Su;Lee, Jae-Hun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.3
    • /
    • pp.488-499
    • /
    • 1996
  • Diabetes mellitus revealed a chronic disorder of lipid, carbohydrate and protein metabolism characterized by insulin deficiency, and a striking tendency toward development of atherosclerosis, microangiopathy, nephropathy, neuropathy and recently cardiomyopathy etc. The mechanism of heart failure in patients with diabetic cardiomyopathy is not clear but diabetic cardiomyopathy usually occurs in persons with long standing diabetes. After diabetes induced in made Sprague- Dawley strain rats by injection of streptozotocin(60mg/kg), cardiac tissue with hematoxylin-eosin and Masson's trichrome stain was examined at 3 days, 1, 2, 4, 6 weeks later under light microscope. The results were obtained as follows : 1. In H&E stain of control group, myocardiac cells were shorter than skeletal muscle cell, which was branched out and connected each other at terminal with striation, intercalated disk and nucleus at center of cell. 2. In MT stain of control group, a few of collagen fibrile were seen at periva scular interstium, but wasn't seen between skeletal muscle fiber, and cardiac muscle was seen in various size. 3. In MT stain of experimental group, increased collagen fiber deposition at perivascular interstiums were seen periodically. 4. In MT stain of experimental group, increased collagen fiber deposition at interstitial matrix between perimyocardiac cells were seen at 3 day, 4 weeks and 6 weeks after DM induction. 5. In H&E stain of experimental group, partial degeneration of myocardiac cells was seen after 4 weeks of DM induction. From above results, streptozotocin induced diabetes mellitus increased collagen around perivascular and between intercellular matrix in heart.

  • PDF

ANTIMICROBIAL SUSCEPTIBILITY TEST ON STREPTOCOCCUS VIRIDANS IN CHILDREN'S ORAL CAVITY (소아의 구강내에서 검출된 Streptococcus viridans에 대한 항균제 감수성 연구)

  • Shin, Sang-Hun;Song, Jung-Ho
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.22 no.3
    • /
    • pp.330-336
    • /
    • 2000
  • A large number of streptococci that do not fit readily into any of the established classification schemes have been relegated to a large heterogeneous group called the Streptococcus viridans, which are members of the normal flora of the mucous membranes of the body, including the oral cavity, the nasopharynx, and genitourinary tract. This group includes S. mitis, S. oralis, S. sanguis, S. salivarius, S. milleri, etc. Surveying on the literature, it has been reported that infective endocarditis, meningitis, rhabdomyolysis, cholangitis, appendicitis caused by Streptococcus viridans, which were the most important pathogen in children with malignant hematologic disease. Various antibiotics has been chosen for treatment or prophylaxis for these infections, but were generally lower antimicrobial susceptibilities because of an abuse of antibiotics and advent of resistant group. Therefore, surveillant culture must be performed to evaluate personal antimicrobial susceptibilities of intraoral microbes for proper antimicrobial choice for dental procedures. This study examined sampling from subgingival plaque of 60 chidren's microbes. The cultured bacterial isolates, Streptococcus viridans were examined 10 antimicrobial drugs with the Kirby-Bauer agar disk diffusion method. The used drugs were Penicillin, Ampicillin, Oxacillin, Cephalothin, Imipenem, Gentamicin, Erythromycin, Vancomycin, Ciprofloxacin, Clindamycin. The results were as follows : 1. Sampling Streptococcus viridans were S. mitis(65%), S. oralis(22%), S. sanguis(5%), S. intermedius(3%), S. salivarius(2%), S acidominimus(2%), Unidentified streptococcus(2%). 2. The antimicrobial susceptibility of total Streptococcus viridans : Oxacillin< Erythromycin< Pencillin=Ciprofloxacin< Cephalothin< Ampicillin< Clindamycin< Gentamicin< Imipenem=Vancomycin. 3. The antimicrobial susceptibility of S. mitis : Oxacillin=Erythromycin< Ciprofloxacin< Cephalothin< Penicillin=Ampicillin< Gentamicin< Clidamycin< Imipenem=Vancomycin. 4. The antimicrobial susceptibility of S. oralis : Oxacillin< Erythromycin< Penicillin=Ciprofloxacin=Clindamycin< Cephalothin=Gentamicin< Ampicillin< Imipenem=Vancomycin. 5. There was no significant difference in the antimicrobial susceptibility among each Streptococcus viridans group.

  • PDF

Finite Element Analysis and Experimental Confirmation of Warm Hydroforming Process (온간 하이드로포밍에 관한 유한요소해석 및 실험적 검증)

  • Kim, B.J.;Park, K.S.;Choi, K.H.;Moon, Y.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2006.05a
    • /
    • pp.277-280
    • /
    • 2006
  • The hydroformability of aluminum alloy sheets at elevated temperatures have been investigated in this study. It is necessary to analyze the variations of the mechanical properties that depend on the forming temperature and the heat conduction during warm hydroforming. Therefore, in this study a coupled simulation of plastic deformation and temperature distribution in the warm hydroforming process is performed and compared with experimental data. The multi-purpose code DEFORM-2D can handle this type of calculations but it takes high computation time if contact heat transfer between die, tube and pressure medium occurs. Experiments were conducted by high temperature tribometer(pin-on-disk) allowing measuring the friction coefficients of the aluminum alloys at several temperatures and these results are applied to the coupled simulation by which the optimal process parameters such as internal pressure and preset temperature on hydroformability can be determined. The comparison of the FE analysis with the experimental results has shown that hydroformability given by bulge height, and temperature distribution of the tube specimen make a little difference with the FE results but the trend predicted by simulation agrees well with experiments.

  • PDF

Wear Mechanism of CrN Coating on Aluminum Alloys Deposited by AIP Method

  • Kim, Seock-Sam;Suh, Chang-Min;Murakami, Ri-ichi
    • KSTLE International Journal
    • /
    • v.3 no.1
    • /
    • pp.43-48
    • /
    • 2002
  • Dry sliding wear and friction test of CrN coaling on two types of aluminum alloy substrates,6061 Al and 7075 Al deposited by arc ion plating, was peformed with a ball-on-disk tribometer. The effects of normal Bead and the mechanical properties of substrate on the friction coefficient and wear-resistance of CrN coating were investigated. The worn surfaces were observed by SEM. The results show that surface micro-hardness of CrN- coated 7075 Al is higher than that of CrN-coated 6061 Al. With an increase in normal lead, wear volume increases, while the friction coefficient decreases. The friction coefficient of CrN-coated 6061 Al is higher than that of CrN-coated 7075 Al, while the wear-resistance of CrN-coated 6061 Al is lower than the CrN-coated 7075 Al's, which indicates that the substrate mechanical properties have strong inf1uences on the friction coefficient and wear of CrN coating. The main wear mechanism was fragments of CrN coating, which were caused by apparent plastic deformation of substrate during wear test.

AN EXPERIMENTAL STUDY ON HARDNESS IN VISIBLE LIGHT-CURED COMPOSITE RESIN AT VARYING DEPTH (가시광선(可視光線) 복합(復合)레진의 심부경도(深部硬度) 측정(測定)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Myoung, Jae-Keun;Lee, Myoung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.11 no.1
    • /
    • pp.43-52
    • /
    • 1985
  • The purpose of this study was to measure the Micro-Knoop Hardness of three commercial visible light-cured composite resins (Plurafil-super, He1iosit and Durafi) according to the difference of depth and shade. Specimens of the resin were prepapared in plastic tubes 5mm in diameter with height of 5mm, and the tubes were put into the columned holes in stone molds. The molds were exposed to the visible light through the hole 5mm in diameter in metal plate. Specimens were sectioned (longitudinally) with disk. Knoop Hardness measurements were made at the depth of surface, 0.5, 1.0, 1.5, 2.0, 2.5 and 3.0mm from the surface to the deep portion. Knoop Hardness numbers were taken on each depth under 20gm load for 10 seconds with Shimadzu Tester. The following results were: 1. The highest hardness value was measured at 0.5mm depth. Then the deeper the depth, the lesser the hardness was observed. 2. The value of hardness was directly propotional to the time of exposure to the light. 3. The hardness of light shade resin was higher than the that of the dark shade. 4. The pattern of hardness change at varying depth is similar to all the experimental materials with no relation to the shade nor exposure time.

  • PDF

A Parametric Study on Rupture Disc with Radial Slit of Pulse Separation Device (원주방향 슬릿을 가진 파열판의 매개변수 연구)

  • Han, Houk-Seop;Cho, Won-Man;Lee, Won-Bok;Koo, Song-Hoe;Lee, Bang-Eop
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.261-264
    • /
    • 2010
  • Dual Pulse Rocket Motor is a solid rocket motor with two grains separated by a bulkhead and rupture disc. The elasto-plastic explicit dynamic analysis of rupture disc was conducted by the finite element method. The effect of the slit geometry of rupture disc with radial slit was parametrically analyzed in terms of rupture time and shape. The results can be used to control the rupture pressure by changing the slit geometry of rupture disc.

  • PDF