• Title/Summary/Keyword: Plastic case

Search Result 2,709, Processing Time 0.034 seconds

A COMPARATIVE STUDY ON THE FIT IN PROSTHESIS USING PREMADE GOLD CYLINDER AND PLASTIC CYLINDER (정밀 연삭된 지대주와 합성수지 지대주를 이용한 보철물의 적합도에 대한 비교 연구)

  • Jung, Seon-Hee;Ma, Jang-Seon;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.6
    • /
    • pp.825-834
    • /
    • 1999
  • Recently, various implant cylinders were supplied. especially received gold cylinders, cast cylinders produced from premade gold and plastic cylinders and plastic cylinders. This study measured and compared precise fit produced when using conventional gold and plastic cylinders. The comparative fit of lapped and non-lapped castings made from plastic pattern was examined. The implant/abutment interface fit was evaluated by scanning electron microscopy(SEM) for each of four cylinders. The following results were obtained: 1. The case of plastic cylinder showed $9.67{\pm}1.50{\mu}m$ gap when Steri-Oss fixture was connected. 2. The case of lapped casting made from plastic cylinder showed $3.01{\pm}2.81{\mu}m$ gap when Steri-Oss fixture was connected. 3 The case of gold/plastic cylinder showed $9.80{\pm}1.68{\mu}m$ gap when Steri-Oss fixture was connected. 4. The case of gold cylinder showed ${5.47{\pm}2.43\mu}m$ gap when Steri-Oss fixture was connected. 5. In case of each cylinder which was connected with Steri-Oss fixture, the size of gap was showed less in the order of the case of gold/plastic cylinder, the case of plastic cylinder, the case of gold cylinder and the case of lapped casting made from plastic cylinder As results of this study, the use of premade gold cylinder offers an advantage over plastic pat-terns in precise fit. When plastic patterns are used, polishing of implant cylinder components should provide precise fit.

  • PDF

A Case Report of Madelung's Disease

  • Bo Hyun Lee;Young Mann Lee;Seong Oh Park;Lan Sook Chang;Youn Hawn Kim
    • Archives of Plastic Surgery
    • /
    • v.50 no.5
    • /
    • pp.463-467
    • /
    • 2023
  • Madelung's disease (MD) is a rare disease characterized by diffuse, nonencapsulated, multiple fat masses in different areas of the body. In this case report, we present a case of MD in Asia and its management. A 66-year-old man with a history of hypertension presented with massive growth of soft tissue around the neck, breasts, upper back, and lower abdomen. Preoperative magnetic resonance imaging revealed remarkably hypertrophic fat tissue around the neck and anterior chest was wall, which consistent with the diagnosis of MD. Multiple linear incisions were made on the neck and 763, 186, 635 g of posterior, right, and left fat tissues were excised, respectively. A single wide, transverse incision was done to excise 1,072 g of fat from the upper back. Masses of both breasts were excised, preserving the inferior pedicle, weighing 1,086 (right) and 1,164 g (left). The recovery was optimal and the patient was discharged without complications. In this case, we excised the adipose masses as much as possible and improved contour and symmetry. However, the fat infiltrations in the patient were diffusely distributed, making total fat excision difficult. This rare case report may help in managing patients with MD.

Development and Enforcement of Short Case Test Items for Evaluation in Undergraduate Course of Plastic Surgery: 3 Years Experience (학부 성형외과학 과목평가를 위한 짧은 사례문항의 개발과 시행: 3년간의 경험)

  • Hwang, Kun;Park, Jun Ho;Lee, Se Il
    • Archives of Plastic Surgery
    • /
    • v.33 no.2
    • /
    • pp.225-232
    • /
    • 2006
  • The aim of this study is to evaluate the clinical competence of medical student using short case test items. Development of short case test items with definition of an assessment of subject, choice of clinical stations sampling, identification of components of clinical competence to be evaluated, and assessment of practicability and results exploitation. For the last three years 28, 48 and 30 topics were developed annually. Among them 20, 23 and 23 topics were selected. About 50 students were examined annually. The mean score was 72.7, 57.1, 64.3 respectively. The mean preparation time of the students for the examination was 9.8 hours. About 60% of the students prepared the test in small group activity. Our experience suggests that short case test items be feasible for evaluation of student learning in Plastic Surgery. This method should be considered as a useful tool to assess medical student's competence or even an examination for board certification.

A Modified Free Thenar Flap with Constant Innervations and Its Clinical Application (일관된 신경 지배를 위한 유리 무지구피판의 수정과 그의 임상 적용)

  • Han, Seung-Kyu;Yang, Jae-Won;Kim, Jin-Soo;Lee, Dong-Chul;Ki, Sae-Hwi;Roh, Si-Young
    • Archives of Plastic Surgery
    • /
    • v.38 no.5
    • /
    • pp.663-668
    • /
    • 2011
  • Purpose: A modified free thenar flap was designed for coverage of volar finger defect with constant innervation using the palmar cutaneous branch of the median nerve. After clinical application of this flap, sensory results were evaluated in 6 cases. Methods: Patients were selected who have volar soft tissue defect with or without fingertip defect. The six cases of the innervated free thenar flap were performed since September 2009, and sensory outcomes were evaluated by the Semmes-Weinstein monofilament and two-point discriminator at four and half month after the surgery. Results: The Semmes-Weinstein Monofilament test revealed 3 cases showed 2.83, 1 case showed 3.61, 1 case showed 4.31 and 1 case showed 4.56. The static two-point discrimination test revealed 1 case showed 4 mm, 1 case showed 6 mm, 2 cases showed 9 mm, and 2 cases showed over 15 mm. The moving two-point discrimination test revealed 1 case showed 3 mm, 1 case showed 4 mm, 1 case showed 5 mm, 1 case showed 7 mm, and 2 cases showed over 15 mm. The donor sites showed no significant limitation of the thumb and neuroma formation. Conclusion: The innervated free thenar flap showed good sensory outcomes as a sensate free flap in a short time after surgery. It can be an option for coverage of volar finger defects that requires sensation.

Bilateral Type III Postaxial Polydactyly: A Case Report (양측성 축뒤손가락과다증의 치험례)

  • Jo, Yong Woo;Lim, So Young;Mun, Goo Hyun;Hyon, Won Sok;Bang, Sa Ik;Oh, Kap Sung
    • Archives of Plastic Surgery
    • /
    • v.32 no.6
    • /
    • pp.773-776
    • /
    • 2005
  • An unusual case is presented as bilateral, complete digital duplication of the hand in a 32-year-old man. Radiographic evaluation showed complete duplication of intact phalanges and metacarpal bones in both hands. Although polydactyly of the hand is reported to occur among approximately 1 in 1000 live births, most of these malformations are rudimentary skin tags. Complete postaxial polydactyly is uncommon; it occurs in approximately 0.014% of all live births. The main goal of the surgical treatment is to establish adequate function and appearance. This case reports the preoperative evaluation and management of bilateral postaxial type III duplication of the fingers.

A Study the Behavior of Plastic Deformation in Weld HAZ of Mild Steel (軟鋼 熔接熱影響部의 塑性變形擧動에 關한 硏究 II)

  • 박창언;정세희
    • Journal of Welding and Joining
    • /
    • v.10 no.1
    • /
    • pp.43-51
    • /
    • 1992
  • The plastic zone formed around a notch tip is important in analyzing the fracture toughness of structures and particularly weld cracks existed in the weld HAZ (heat affected zone) which produces local plastic deformation at the crack tip. Therefore, in order to analyze the fracture toughness in weld HAZ, it is necessary to investigate the new fracture toughness parameter $K_{c}$ $^{*}$ and critical plastic strain energy $W_{p}$ $^{c}$ according to the shape and size of the plastic zone. 1) If the temperature corresponding to $K_{c}$ $^{*}$=130kg-m $m^{-3}$ 2/ is determined, transition temperature $T_{tr}$ the magnitude of plastic zone size, and heat input change depending on the fracture toughness. The blunted amounts of the parent and weld HAZ show mild linear variation until .delta.=0.4mm and then increase very steeply there after. 2) The relation between the plastic strain energy( $W^{p}$ ) and transition temperature( $T_{*}$tr) in parent metal is more sensitive than that of weld HAZ. However, the plastic strain energy depends on the transition temperature, and thus the yield stress, .sigma.$_{ys}$ becomes an important parameter for plastic strain energy. 3) The critical plastic strain energy( $W_{p}$ $^{c}$ ) absorbed by the plastic zone at the notch tip indicated in case of parent metal: 60J/mm, in case of heat input(20KJ/cm): 75J/mm, in case of heat input(30KJ/cm); 50J/mmJ/mm.

  • PDF

A Guide to Designing a Case Series in Plastic Surgery (성형외과 영역에서 임상증례군 보고 형식의 논문 작성 가이드)

  • Kim, Tae-Gon;Kim, Il-Kug
    • Archives of Craniofacial Surgery
    • /
    • v.13 no.1
    • /
    • pp.1-3
    • /
    • 2012
  • The case series is a descriptive study that follows a group of patients who have a similar diagnosis or who are undergoing the same procedure and is the most prevalent type of research in the field of plastic surgery. Results of case series can generate hypotheses that are useful in designing further studies, including randomized controlled trials or a prospective cohort study. However, no causal inferences should be made from case series regarding the efficacy of the investigated treatment. The authors provide a guide to the design and report on the case series.

A Study of Chaotic Responses of an Elastic-Plastic Beam Model to Periodic Impulsive Force (주기적인 충격력을 받는 탄소성 보의 케이오틱거동 연구)

  • 이재영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.5
    • /
    • pp.1158-1167
    • /
    • 1995
  • In this study, the dynamic instabilities of a beam, subjected to periodic short impulsive loading, are investigated using simple 2-DoF beam model. The behaviors of beam model whose axial motions are constrained are studied for the case of elastic and elastic-plastic behavior. In the case of elastic behavior, the chaotic responses due to the periodic pulse are identified, and the characteristics of the behavior are analysed by investigating the fractal attractors in the Poincare map. The short-term and long-term responses of the beam are unpredictable because of the extreme sensitivities to parameters, a hallmark of chaotic response. In the case of elastic-plastic behavior, the responses are governed by the plastic strains which occur continuously and irregularly as time increases. Thus the characteristics of the response behavior change continuously due to the plastic strain increments, and are unpredictable as well as the elastic case.

Effect of Bend Angle on Plastic Loads of Pipe Bends Under Internal Pressure and In-Plane Bending (내압과 굽힘하중을 받는 곡관의 소성 하중에 굽힘 각도가 미치는 영향)

  • Lee, Kuk-Hee;Oh, Chang-Sik;Yoo, Bong;Park, Chi-Yong;Kim, Yun-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.3 s.258
    • /
    • pp.322-330
    • /
    • 2007
  • This paper quantifies the effect of a bend angle of a pipe bend on plastic loads, via small strain and large strain FE limit analyses using elastic-perfectly plastic materials. To consider the effect of the attached straight pipe, two limiting cases are considered. One case corresponds to the pipe bend without the attached straight pipe, and the other to that with a sufficiently long attached straight pipe. For the former case, the FE results suggest that the limit load is not affected by the bend angle for both in-plane bending and internal pressure. For the latter case, however, the bend angle affects plastic loads. An interesting finding is that the plastic load smoothly changes from the limit load of the straight pipe when the bend angle approaches zero to the plastic load of the $90^{\circ}$ pipe bend when the bend angle approaches 90 degree. Based on such observations, closed-form plastic load solutions are proposed for the pipe bend with an arbitrary bend angle under in-plane bending and internal pressure.

Scalp metastasis from an adenocarcinoma of the lung mimicking a cystic mass: case report and literature review

  • Kim, Han Koo;Kang, Seung Hyun;Kim, Woo Seob;Kang, Shin Hyuk;Kim, Woo Ju;Kim, Hyeon Seok;Bae, Tae Hui
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.5
    • /
    • pp.237-240
    • /
    • 2022
  • A 67-year-old man visited our plastic surgery clinic complaining of a palpable protruding mass (2.0×2.5 cm) in the right occipital region. To establish an appropriate treatment plan for the cystic mass, brain magnetic resonance imaging was performed. A 2.2 cm nodular lesion with peripheral enhancement in the right occipital region of the scalp was confirmed. In addition, two rim-enhancing nodular lesions up to 9 mm with marked perilesional edema in the right frontal lobe were confirmed. The findings suggested metastasis from cancer. After further evaluations, a mass in the right lower lung field was identified as adenocarcinoma of the lung. Histological examination characterized the excised lesion as a cutaneous metastasis from lung adenocarcinoma. This case report shows that a cystic mass, which commonly occurs in the scalp, may indicate lung cancer. In particular, if a cystic mass of the scalp is identified in a person at high risk for lung cancer, appropriate evaluation and urgent treatment should be performed.