• Title/Summary/Keyword: Plastic Ring

Search Result 146, Processing Time 0.024 seconds

Evaluation of Optimized Ring Specimen Shape for the Hoop Behavior Test of Nuclear Fuel Clad Tube (핵연료 피복관의 후우프 거동시험을 위한 시편의 최적형상 평가)

  • 서기석
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2000.04a
    • /
    • pp.171-178
    • /
    • 2000
  • In order to evaluate the tensile behaviors of hoop direction for the nuclear fuel cladding tubes the shapes of specimen and jig fixtures for the ring test are decided with various conditions under the elastic-large plastic deformations. The axial displacement of the jig cylinders is converted to the circumferential direction elongations of specimen. The stress distributions on specimen are depended on the radii and locations of specimen and jig size and central angle. Therefore we calculated the stress distributions and decided the optimum shapes to get the uniform stress in the area of specimen gage length. Form the analysis the stress distributions in gate area are reviewed with the radii and location of specimen notch and the central angle of jig cylinder,. The optimum shapes of specimen and jig are proposed to the clad tube having 10.62 mm in diameter and 0.63mm in thickness for 16x16 PWR nuclear fuel assembly.

  • PDF

Stress Analysis of the Prestressed Dies by Using FEM (유한요소법을 이용한 예압된 금형의 응력해석)

  • Yeo, Hong-Tae;Choi, Young;Hur, Kwan-Do
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.6
    • /
    • pp.114-122
    • /
    • 1999
  • By using the FEM, a method for the stress analysis of the presented dies has been proposed. In this method, FEM and Lame equation are used for the analysis of the die insert and the stress ring, respectively. The proposed method includes the calculation of the contact pressure between the die insert and the stress ring. To show the validity, the proposed method has been applied to the simple test problem. The results of the stress analysis have been compared with the results of ANSYS, a commercial FE-code. Cold extrusion has been simulated by using the rigid-plastic FEM and the results of the deformation analysis have been used as the input of the die structure analysis. The stress states of the prestressed extrusion die have been obtained. The stress analysis of the die insert with stress rings has also been performed during extrusion.

  • PDF

Entrapment Neuropathy of Median and Ulnar Nerve Due to Soft Tissue Chondroma: A Case Report (연부조직 연골종에 의한 정중, 척골포착신경병증: 증례보고)

  • Hong, Sung-Taek;Ahn, Duck-Sun
    • Archives of Plastic Surgery
    • /
    • v.37 no.6
    • /
    • pp.815-818
    • /
    • 2010
  • Purpose: Soft tissue chondroma is a rare benign tumor, found mainly on the palm and sole and grows slowly. Typically, mature hyaline cartilage is the dominant pathological feature. There are reports that assert soft tissue chondromas to be a cause of median nerve entrapment syndrome. However, this is the first case report showing soft tissue chondroma to be a cause of simultaneous median and ulnar neuropathy. Methods: A 62 year-old woman presented with chief complaints of numbness and hypoesthesia of her right palm for 4 to 5 years, and a palpable mass on her right palm that had been increasing in size slowly for 3 years. Physical examination revealed a firm, mobile, non-tender and about $3{\times}3\;cm^2$ sized mass in the center of the right palm. Electromyography showed entrapment neuropathy of the median and ulnar nerve. Ultrasonography showed an approximately $5.7\;cm^2$ mass below the flexor tendon of ring finger. Upon surgical excision, a $3{\times}3\;cm^2$ mass attached to the flexor digitorum profundus of ring finger and redness and hypertrophy of both the median and ulnar nerve were discovered. Mass excision was performed gently and the specimen was referred for histopathologic study. Mass excision resulted in median and ulnar nerve release. Results: The pathology report confirmed the mass to be a soft tissue chondroma with mature hyaline cartilage. The patient exhibited post-operative improvement of her symptoms and did not show any complications. Conclusion: This is the first case report showing soft tissue chondroma to be a cause of simultaneous median and ulnar neuropathy.

A Tunable Digital Tourniquet Using Nelaton Catheter (고무 도뇨관을 이용한 간단한 수지 지혈대)

  • Kim, Sang Wha;Yim, Young Min;Jung, Sung No;Kwon, Ho
    • Archives of Plastic Surgery
    • /
    • v.35 no.6
    • /
    • pp.759-761
    • /
    • 2008
  • Purpose: Surgery on digit requires a clear, bloodless field and it can be achieved by using a tourniquet. Several type of tourniquet have been used including Penrose drains and sterile glove with hemostat. We present a simple digital tourniquet using nelaton catheter, which is easily available, inexpensive, easy-to-apply, and effective for digital surgery. Methods: We made a small incision on the opposite side of an opening at the tip of nelaton catheter. Then the other tip of nelaton catheter is passed through the incision to form a ring. Nelaton catheter is placed aournd the base of the injured finger, making a tight circle to desired pressure. Results: A simple tourniquet using nelaton catheter effectively achieves a bloodless field and allows fine control of the pressure for digital surgery. Conclusion: We present a sismple digital tourniquet using nelaton catheter, which is easily available, inexpensive, tunable, and available for more than one finger.

A Study on the Development of Plat-Ring Restrained Test Method for Evaluating Early Age Shrinkage Crack of Concrete (콘크리트의 초기수축균열 평가를 위한 판상-링형 구속시험방법 개발에 관한 연구)

  • Nam, Jeong-Soo;Park, Yoon-Mi;Kim, Young-Sun;Kim, Young-Duck;Kim, Gyu-Yong;Kim, Moo-Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.821-824
    • /
    • 2008
  • In this study, it is willing to present that fundamental data for proposing quantitatively shrinkage cracking evaluation method such as plat-ring type restrained test method. It is possible to decide that specimen diameter is s 150mm with evaluating restrained shrinkage crack properties of concrete according to change of ring diameter in specimen. Also, effectiveness of test method according to mixing of PVA fiber is evaluated as part of a repeatability verification experiment of plat-ring type restrained test method using ring which diameter is 150mm. As a result, it is possible to measure the crack due to the plastic shrinkage which was occurred within 48hours at early age with plat-ring type restrained test method. Hereafter, it is considered that the study concerning environmental condition and mixing factor in plat-ring type restrained test method is need.

  • PDF

Energy absorption of the ring stiffened tubes and the application in blast wall design

  • Liao, JinJing;Ma, Guowei
    • Structural Engineering and Mechanics
    • /
    • v.66 no.6
    • /
    • pp.713-727
    • /
    • 2018
  • Thin-walled mental tubes under lateral crushing are desirable and reliable energy absorbers against impact or blast loads. However, the early formations of plastic hinges in the thin cylindrical wall limit the energy absorption performance. This study investigates the energy absorption performance of a simple, light and efficient energy absorber called the ring stiffened tube. Due to the increase of section modulus of tube wall and the restraining effect of the T-stiffener flange, key energy absorption parameters (peak crushing force, energy absorption and specific energy absorption) have been significantly improved against the empty tube. Its potential application in the offshore blast wall design has also been investigated. It is proposed to replace the blast wall endplates at the supports with the energy absorption devices that are made up of the ring stiffened tubes and springs. An analytical model based on beam vibration theory and virtual work theory, in which the boundary conditions at each support are simplified as a translational spring and a rotational spring, has been developed to evaluate the blast mitigation effect of the proposed design scheme. Finite element method has been applied to validate the analytical model. Comparisons of key design criterions such as panel deflection and energy absorption against the traditional design demonstrate the effectiveness of the proposed design in blast alleviation.

Determination of Constant Friction Factor and Forming Characteristics of Sintered Porous Metal (소결금속 의 성형 특성 및 마찰 상수 결정 에 관한 연구)

  • 오흥국;문재호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.2
    • /
    • pp.111-118
    • /
    • 1984
  • On the basis of plasticity theory for porous metal, an analysis of ring compression is carried out, employing the upper bound approach. The plastic flowability and the neutral radius of porous metal ring are calculated and deformation characteristics of power forging are obtained from this result. The experiments on ring compression are carried out for sintered iron porous metal with various relative densities under various friction conditions. A good agreement is observed between the shapes of the calculated curves and the experimental results from the ring compression test. The friction factor for powder metal forming can be determined not only from the relationship between reduction in height and reduction in internal diameter but independently from the relationship between reduction in height and relative density, if the initial relative density is known.

Finite Element Analysis of Glass Fiber Reinforced Plastic Pipes Under Internal Pressure (내압을 받는 복합 적층 파이프(GFRP) 구조의 유한요소 해석)

  • 조병완
    • Computational Structural Engineering
    • /
    • v.7 no.2
    • /
    • pp.101-109
    • /
    • 1994
  • A degenerated cylindrical shell element for modeling glass fiber reinforced plastic pipes is developed and its performance for static structural analysis under internal uniform pressure is evaluated. The element is a nine node degenerated solid shell element with reduced integration technique, addition of nonconforming displacement modes, and assumed strain method to improve convergence of analysis. Several numerical examples are solved and compared with analytical solutions and other F.E.M programs, The results show that the increment of fiber orientation in the GFRP pipes with reference to the longitudinal axis cause less radial displacements and much stiffness in the pipes. This is reasonable since the internal pressure will primarily cause hoop stresses in the ring and 90-angle ply GFRP ring carry these efficiently in pure tension.

  • PDF

An Anatomic Study of the Extensor Tendons of the Human Hand (수배부의 신전건에 대한 해부학적 연구)

  • Kang, Moon-Seok;Jung, Sung-Gyun;Nam, Seoung-Min;Shin, Ho-Seong;Kim, Yong-Bae
    • Archives of Plastic Surgery
    • /
    • v.38 no.6
    • /
    • pp.836-844
    • /
    • 2011
  • Purpose: Hands are the chief organs for physically manipulating the environment, using anywhere from the roughest motor skills to the finest, and since the fingertips contain some of the densest areas of nerve endings on the human body, they are continuously used organ with complex functions, and therefore, often gets injured. To prevent any functional loss, a detailed anatomical knowledge is required to have a perfect surgical treatment. Also it is necessary to have a thorough understanding of arrangements of the human extensor tendons and intertendinous connections when tenoplasty or tendon transfer is required. We performed a study of the arrangements of the human extensor tendons and the configuration of the intertendinous connections over the dorsum of the wrist and hand. Methods: A total of 58 hands from Korean cadavers were dissected. The arrangements of extensor indicis proprius, extensor digitorum communis, and extensor digiti minimi tendons and intertendinous connections were studied. Results: The most common distribution patterns of the extensor tendons of the fingers were as follows: a single extensor indicis proprius (EIP) tendon which inserted ulnar to the extensor digitorum-index (EDC-index); a single EDC-index; a single EDC-middle; a double EDC-ring; an absent EDC-little; a double extensor digiti minimi (EDM), a single EDC-index (98.3%), a single EDC-middle (62%), a double EDC-ring (50%), and an absent (65.5%) or a single (32.8%) EDC-little. A double (70.6%) EDM tendons were seen. Intertendinous connections were classified into 3 types: type 1 with thin filamentous type, type 2 with a thick filamentous type, and type 3 with a tendinous type subdivided to r shaped 3r type and y shaped 3y type. The most common patterns were type 1 in the 2nd intermetacarpal space, type 2 in the 3rd intermetacarpal space, and type 3r in the 4th intermetacarpal space. And in the present study, we observed one case of the extensor digitorum brevis manus (EDBM) on the boht side. Conclusion: A knowledge of both the usual and possible variations of the extensor tendon and the intertendinous connection is useful in the identification and repair of these structures.

An Evaluation of Plastic and Early Dry Shrinkage of Fiber Reinforced Concrete Using Recycled Aggregate (순환잔골재를 활용한 섬유 보강 콘크리트의 소성 및 초기 건조수축평가)

  • Park, Yun-Mi;Kim, Young-Duck;Kim, Young-Sun;Kim, Ho-Dong;Kim, Gyu-Yong;Kim, Moo-Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.937-940
    • /
    • 2008
  • Recently, the recycling and reusing of construction and demolition waste concrete is urgently required because generation quantity of construction and demolition waste concrete is greatly increased according to the rapid increasing of urban redevelopment project. On the other hand, the problem solution for demand and supply unbalance of fine aggregate is urgently required because of the restriction of collecting sea fine aggregate by intensification of environment influence evaluation and the shortage of river fine aggregate. but a quality of aggregate as building structure is not demonstrated. Therefore it is the objective of this study to estimate plastic and early dry shrink crack of fiber reinforced concrete using a recycled aggregate by plat-ring test and mock-up test of exposure to the air. as a result, in case of plat- ring test, developing crack is wider using recycled aggregate concrete than natural aggregate concrete, is wider using fiber reinforced concrete than non fiber. in case of mock-up test of exposure to the air, it is similar to plat-ring test.

  • PDF