• 제목/요약/키워드: Plastic Fan

검색결과 61건 처리시간 0.025초

플라스택 팬 설계, 제조의 CIM 구축을 위한 연구 (A study on CIM construction for the plastic fan design manufacturing)

  • 최양호;이용성
    • 대한기계학회논문집A
    • /
    • 제21권9호
    • /
    • pp.1470-1479
    • /
    • 1997
  • In this study, the plastic fan with high efficiency and low noise was designed and the capacity of the wind and the wind pressure were analysed and verified by CAE. After designing the metallic mold using the metallic mold design data, and the the metallic mold design was reformed by analysing the process of the material stream and injection filling by CAE. Also the metallic mold cutting data were formed using the metallic mold design data. These cutting data was used to produce the fan electrode by a machining center and then this electrode were used to manufacture the metallic mold by cutting the fan cavity by an electrical spark machine. The purpose of this study is to find out the sub-optimal condition on the productivity and improvement in quality of the plastic fan by integrating a series of this process with a computer.

비대칭형 플라스틱 팬 제품 개발 (Development of Asymmetric Plastic Fan Product)

  • 연규현;김형국
    • 한국기계가공학회지
    • /
    • 제8권2호
    • /
    • pp.53-59
    • /
    • 2009
  • The analysis of injection molding process by CAE is widely used in development of plastic products. That comes from the fact that CAE analysis can reduce trial and error based on optimized design. On this study, by use of MOLDFLOW, the causes of product defects were found and solved by trade-off study. CAE analysis includes Flow-Cool-Warpage Analyses and finally a new mold-die design with better product quality was suggested. On injection molding of round-shaped plastic fan, new mold-die system with 4-tunnel gates located on the edge of a fan disc shows better quality rather than pin-point gate located on the center of a disc. That was effective in terms of flow mark removal and flatness improvement of the product.

  • PDF

휨 변경 최소화 근접 냉각 금형을 통한 고성능 고효율 플라스틱 축류팬 개발 (Development of high performance and efficiency plastic axial fan by proximity cooling mold to minimize warpage)

  • 신광호;김미애;채보혜;박상옥;김용대
    • Design & Manufacturing
    • /
    • 제13권1호
    • /
    • pp.61-67
    • /
    • 2019
  • The cooling unit of the industrial showcase consists of a compressor, a condenser and an evaporator. An axial fan is used to circulate the air to improve the efficiency of the heat exchanger. In the past, aluminum fans have been used, which have problems such as low performance, efficiency, high failure rate, and high noise. This study is to develop high performance, high efficiency plastic fan replacing aluminum fan. A major factor in determining the performance and noise of an axial fan is the angle and cross-sectional shape of the blade, which is suitable for raising the lift force, thereby controlling the vortex, which is the main cause of noise and performance degradation. In order to produce a high efficiency injection molded fan, it is necessary to develop a mold that minimizes the deformation of the injection process for the designed shape. In this study, we developed a high efficiency, low noise plastic injection fan with more than 11% performance improvement and noise reduction compared to conventional aluminum fan.

자동차용 냉각팬의 불량검출을 위한 팬 밸런서 시스템 개발 (Design of Fan Balancing System for Detecting Unbalance of Automobile Cooling Fan)

  • 육의수;김성호
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국지능시스템학회 2008년도 춘계학술대회 학술발표회 논문집
    • /
    • pp.273-275
    • /
    • 2008
  • 일반적으로 자동차용 냉각팬은 차량 냉각기의 온도를 낮추기 위해 사용되고 있다. 자동차용 냉각팬은 플라스틱 사출 공정에 의해 제작되며 사출시 사용되는 모재의 불균일성으로 인해 냉각팬 날개의 무게 중심이 중심에서 벗어나는 경우가 발생하게 된다. 이러한 불균형은 자동차 소음의 주된 원인이 되기 때문에 이에 대한 검사는 필수적으로 요구된다. 이에 본 연구에서는 로드셀을 이용한 냉각팬 회전날개에서 발생되는 불균형의 위치 및 크기를 효율적으로 검출할 수 있는 팬 밸런서를 개발하고자 한다.

  • PDF

라디에이터 팬의 재질에 따른 열 내구성 해석 (Thermal Durability Analysis Due to Material of Radiator Fan)

  • 한문식;조재웅
    • 한국생산제조학회지
    • /
    • 제22권5호
    • /
    • pp.789-794
    • /
    • 2013
  • In this study, the temperature, heat emission per unit time, and thermal stress or deformation of a radiator fan made of polyethylene or aluminum are analyzed for investigating its strength durability. Heat transfer in the case of the aluminum radiator fan is better than that in the case of the polyethylene radiator fan. Further, heat emission in the case of the aluminum fan is poorer than that in the case of the polyethylene fan. Moreover, because the thermal deformation of aluminum is much smaller than that of polyethylene, the thermal durability of the aluminum fan is better than that of the polyethylene fan. In an open space in front of the radiator and the closed space of the engine behind it, the thermal cooling effect of the polyethylene fan is better than that of the aluminum fan. Further, since polyethylene is lighter in weight than aluminum, polyethylene, as a nonmetallic plastic, is more suitable as a material of an automotive radiator. However, because of the higher strength durability of the aluminum fan, it is better than the polyethylene fan under high-temperature conditions or in the case of a complex pipe.

자동차용 냉각팬의 불량검출을 위한 팬 밸런서 시스템 개발 (Development of Fan Balancer System for Detecting Unbalance of Automobile Cooling Fan)

  • 김성호;육의수
    • 한국지능시스템학회논문지
    • /
    • 제19권1호
    • /
    • pp.83-89
    • /
    • 2009
  • 일반적으로 자동차용 냉각팬은 차랑 냉각기의 온도를 낮추기 위해 사용되고 있다. 자동차용 냉각팬은 플라스틱 사출 공정에 의해 제작되며 사출시 사용되는 모재의 불균일성으로 인해 냉각팬 날개의 무게 중심이 중심에서 벗어나는 경우가 발생하게 된다. 이러한 불균형은 자동차 소음의 주된 원인이 되기 때문에 이에 대한 검사는 필수적으로 요구된다. 이에 본 연구에서는 로드셀을 이용한 냉각팬 회전날개에서 발생되는 불균형의 위치 및 크기를 효율적으로 검출할 수 있는 팬 밸런서 시스템을 제안하고 제안된 시스템의 불평형 검출 성능 확인을 위해 실제 적용 실험을 수행하였다.

환기조절 및 약제적기살포에 의한 비닐하우스재배 오이에 발생하는 노균병 방제 (Control of downey mildew occurred on cucumber cultivated under plastic film house condition by optimal application of chemical and installation of ventilation fan)

  • 김용기;류재당;류재기;이상엽;심홍식
    • 농약과학회지
    • /
    • 제7권3호
    • /
    • pp.223-227
    • /
    • 2003
  • 경기도 수원의 농업과학기술원 시험포장내 비닐하우스에서 오이에 발생하는 병을 조사한 결과 잘록병, 노균병, 흰가루병, 덩굴쪼김병이 발생하였으며, 그 중 오이 노균병이 가장 심하게 발생하였고 피해도 매우 큰 것으로 나타났다. 오이 노균병을 효과적으로 방제하기 위하여 환기팬 설치 효과 및 방제적기 구명을 위한 연구를 수행하였다. 오이노균병 방제를 위하여 비닐하우스의 전면과 후면에 2개의 환기팬을 설치한 다음 하우스 내의 공중습도와 노균병 발생을 조사한 결과, 환기팬무설치하우스에 비해 공중습도가 6.4% 가량 낮아졌으며 노균병 발생을 현저히 억제하는 것으로 나타났다. 환기팬을 설치한 실험구는 환기팬을 설치하지 않고 약제를 3회 처리한 것과 대등한 효과를 보였다. 한편 노균병의 방제적기를 구명하기 위하여 발병 3 일전, 발병직후 및 발병 2일 후부터 각각 3회 디메쏘모르프 염기성염화동수화제를 7일 간격으로 3회 처리한 결과, 발병 3일전부터 예방위주로 약제를 처리하였을 때에는 72.9%의 방제효과를 나타냈으나, 발병직후부터 처리하였을 때에는 61.8%, 발병 2일 후부터 처리하였을 때에는 23.7%의 방제효과를 보여 노균병을 효과적으로 방제하기 위하여는 예방위주의 방제가 필요한 것으로 판단되었다.

박과작물 재배 단동 비닐하우스의 천장 환기시스템 설치 실태조사 (A field survey on roof ventilation system of single-span plastic greenhouse in cucurbitaceae vegetable cultivation)

  • 여경환;유인호;이한철;정재완;최경이
    • 농업과학연구
    • /
    • 제40권4호
    • /
    • pp.317-323
    • /
    • 2013
  • This research was conducted to obtain the basic information for establishment of standard guidelines in the design and installation of roof ventilation system in single-span plastic greenhouse. To achieve this, the greenhouse structure & characteristics, cultivation status, and ventilation system were investigated for single-span greenhouse with roof ventilation system cultivating the Cucurbitaceae vegetables, watermelon, cucumber, and oriental melon. Most of single-span watermelon greenhouse in Haman and Buyeo area were a hoop-style and the ventilation system in those greenhouses mostly consisted of two different types of 'roof vent (circular or chimney type) + side vent (hole) + fan' and 'roof vent (circular type) + side vent (hole or roll-up type)'. The diameter of circular and chimney-type vent was mostly 60cm and the average number of vents was 10.5 per a bay with vent spacing of average 6.75m. The ratio of roof vent area to floor area and side vent area in the single-span watermelon greenhouse with ventilation fan were 0.46% and 7.6%, respectively. The single-span cucumber greenhouse in Haman and Changnyeong area were a gable roof type, such as even span, half span, three quarter and the 70.6% of total investigated single-span greenhouses was equipped with a roof ventilation fan while 58.8% had a circulation fan inside the greenhouse. The ratios of roof vent area to floor area in the single-span cucumber greenhouse ranged from 0.61 to 0.96% and in the case of the square roof vent, were higher than that of the circular type vent. On average, the roof ventilation fan in single-span cucumber greenhouse was equipped with the power input of 210W and maximum air volume of $85.0m^3/min$, and the number of fans was 9.75 per a bay. The number of roof vent of single-span oriental melon greenhouse with only roll-up type side vent ranged from 8 to 21 (average 14.8), which was higher than that of other Cucurbitaceae vegetables while the vent number of the greenhouse with a roof ventilation fan was average 7 per a bay.