• Title/Summary/Keyword: Plasma-UV Process

Search Result 66, Processing Time 0.033 seconds

A Study on the Ralstonia Solanacearum Inactivation using Improved Plasma Process (개선된 플라즈마 공정을 이용한 Ralstonia Solanacearum 불활성화에 관한 연구)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.23 no.3
    • /
    • pp.369-378
    • /
    • 2014
  • Effect of improvement of the dielectric barrier discharge (DBD) plasma system on the inactivation performance of bacteria were investigated. The improvement of plasma reactor was performed by combination with the basic plasma reactor and UV process or combination with the basic plasma reactor and circulation system which was equipped with gas-liquid mixer. Experimental results showed that tailing effect was appeared after the exponential decrease in basic plasma reactor. There was no enhancement effect on the Ralstonia Solanacearum inactivation with combination of basic plasma process and UV process. The application of gas-liquid mixing device on the basic plasma reactor reduced inactivation time and led to complete sterilization. The effect existence of gas-liquid mixing device, voltage, air flow rate (1 ~ 5 L/min), water circulation rate (2.8 ~ 9.4 L/min) in gas-liquid mixing plasma, plasma voltage and UV power of gas-liquid mixing plasma+UV process were evaluated. The optimum air flow rate, water circulation rate, voltage of gas-liquid mixing system were 3 L/min, 3.5 L/min and 60 V, respectively. There was no enhancement effect on the Ralstonia Solanacearum inactivation with combination of gas-liquid mixing plasma and UV process.

E. coli Disinfection Using a Multi Plasma Reactor (멀티 플라즈마 반응기를 이용한 E. coli 소독)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.2
    • /
    • pp.187-195
    • /
    • 2013
  • Objectives: For the practical application of the dielectric barrier discharge plasma reactor, a plasma reactor able to manage large volumes of water is needed. This study investigated the possibility of the practical application of a multi-plasma reactor which is a scaled-up version of a single plasma reactor. Methods: The multi-plasma reactor consists of several high-voltage transformers and plasma modules (discharge, ground electrodes and quartz dielectric tubes). The effects of water characteristics such as voltage (30-120 V), air flow rate (1-5 l/min), number of high-voltage transformers and plasma modules, and water quality on Escherichia coli (E. coli) disinfection and decrease of COD and $UV_{254}$ absorbance were investigated. Results: The experimental results showed that at a voltage of over 80 V, most of the E. coli were disinfected within 90 seconds. E. coli inactivation was not affected by the air flow rate. E. coli disinfection in the multiplasma process showed the traditional log-linear form of the disinfection curve. E. coli inactivation performance by transformer 3-Reactor 5 and transformer 3-Reactor 3 were similar. The disinfection performance of the UV process was affected by artificial sewage water. However, the plasma process was less affected by the artificial sewage within the standards for effluent water quality. Conclusions: Disinfection performance with several low voltages and plasma modules of three to five in number applied to the plasma process was higher than that concentrating a small amount of high voltage through a single plasma reactor. Removal of COD, $UV_{254}$ absorbance, and E. coli disinfection with the plasma process were better than with the UV process.

Performance Improvement of Dielectric Barrier Plasma Reactor for Advanced Oxidation Process (고급산화공정용 유전체 장벽 플라즈마 반응기의 성능 개선)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.7
    • /
    • pp.459-466
    • /
    • 2012
  • In order to improved treatment performance of dielectric barrier discharge (DBD) plasma, plasm + UV process and gas-liquid mixing method has been investigated. This study investigated the degradation of N, N-Dimethyl-4-nitrosoaniline (RNO, indicator of the generation of OH radical). The basic DBD plasma reactor of this study consisted of a plasma reactor (consist of quartz dielectric tube, titanium discharge (inner) and ground (outer) electrode), air and power supply system. Improvement of plasma reactor was done by the combined basic plasma reactor with the UV process, adapt of gas-liquid mixer. The effect of UV power of plasma + UV process (0~10 W), gas-liquid mixing existence and type of mixer, air flow rate (1~6 L/min), range of diffuser pore size (16~$160{\mu}m$), water circulation rate (2.8~9.4 L/min) and UV power of improved plasma + UV process (0~10 W) were evaluated. The experimental results showed that RNO degradation of optimum plasma + UV process was 7.36% higher than that of the basic plasma reactor. It was observed that the RNO decomposition of gas-liquid mixing method was higher than that of the plasma + UV process. Performance for RNO degradation with gas-liquid mixing method lie in: gas-liquid mixing type > pump type > basic reactor. RNO degradation of improved reactor which is adapted gas-liquid mixer of diffuser type showed increase of 17.42% removal efficiency. The optimum air flow rate, range of diffuser pore size and water circulation rate for the RNO degradation at improved reactor system were 4 L/min, 40~$100{\mu}m$ and 6.9 L/min, respectively. Synergistic effect of gas-liquid mixing plasma + UV process was found to be insignificant.

Inactivation of Microorganisms in Sewage Using a Pilot Plasma Reactor (Pilot 플라즈마 반응기를 이용한 하수 중 미생물의 불활성화)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.3
    • /
    • pp.289-299
    • /
    • 2013
  • Objectives: For the field application of the dielectric barrier discharge plasma reactor, scale-up of the plasma reactor is needed. This study investigated the possibility of inactivation of microorganisms in sewage using pilot multi-plasma reactor. We also considered the possibility of degradation of total organic carbon (TOC) and nonbiodegradable matter ($UV_{254}$) in sewage. Methods: The pilot plasma reactor consists of plasma reactor with three plasma modules (discharge electrode and quartz dielectric tube), liquid-gas mixer, high voltage transformers, gas supply equipment and a liquid circulation system. In order to determine the operating conditions of the pilot plasma reactor, we performed experiments on the operation parameters such as gas and liquid flow rate and electric discharge voltage. Results: The experimental results showed that optimum operation conditions for the pilot plasma reactor in batch experiments were 1 L/min air flow rate), 4 L/min liquid circulation rate, and 13 kV electric discharge voltage, respectively. The main operation factor of the pilot plasma process was the high voltage. In continuous operation of the air plasma process, residual microorganisms, $UV_{254}$ absorbance and TOC removal rate at optimal condition of 13 kV were $10^{2.24}$ CFU/mL, 56.5% and 8.6%, respectively, while in oxygen plasma process at 10 kV, residual microorganisms, $UV_{254}$ absorbance and TOC removal rate at optimal conditions were $10^{1.0}$ CFU/mL, 73.3% and 24.4%, respectively. Electric power was increased exponentially with the increase in high voltage ($R^2$ = 0.9964). Electric power = $0.0492{\times}\exp^{(0.6027{\times}lectric\;discharge\;voltage)}$ Conclusions: Inactivation of microorganisms in sewage effluent using the pilot plasma process was done. The performance of oxygen plasma process was superior to air plasma process. The power consumption of oxygen plasma process was less than that of air plasma process. However, it was considered that the final evaluation of air and oxygen plasma must be evaluated by considering low power consumption, high process performance, operating costs and facility expenses of an oxygen generator.

The Optical Property of Plasma-treated ZnO Nanorods (플라즈마 처리한 ZnO 나노막대의 광학적 특성)

  • Cho, Hyun-Min;Yu, Se-Gi;Cho, Jae-Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.3
    • /
    • pp.230-234
    • /
    • 2009
  • Hydrogen and Oxygen plasma treatments have been done on sonochemical grow ZnO nanorods by varying treatment temperature and time, The changes(position and intensity) in ultraviolet(UV) peaks and green peaks of photoluminescence(PL) spectroscopy have been measured, Experimental results showed; i) in the case of hydrogen plasma treatment, the blue shift of UV peak and the increase of PL intensity of the UV peak were observed as the increase of the process time and temperature, ii) in the case of oxygen plasma treatment, the red shift of green peak was observed and the ratio of $I_{Green}/I_{UV}$ was also increased, as the increase of the process time and the temperature.

Comparison of PCB Surface Treatment Effect Using UV Equipment and Atmospheric Pressure Plasma Equipment (UV 장비 및 대기압 플라즈마 장비를 이용한 PCB 표면 처리 효과 비교)

  • Ryu, Sun-Joong
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.16 no.3
    • /
    • pp.53-59
    • /
    • 2009
  • Low pressure mercury lamp type UV equipments have been widely used for cleaning and modification of PCB surfaces. To enhance the productivity of the process, we newly developed remote DBD type atmospheric pressure plasma equipment. The productivity of both equipments could be compared by measuring surface contact angle for various transferring speed. By the result of the measurement, we could verify that the productivity of the atmospheric pressure plasma be superior to the productivity of the UV equipment. XPS experiments confirmed that the surface effect of the UV and atmospheric pressure plasma processing are similar for each other. Organic contamination level was reduced after the processing and some surface elements were oxidized for both cases. Finally, the atmospheric pressure plasma equipment was adapted to flip chip BGA's flux printing process and it was concluded that the printing uniformity be enhanced by the atmospheric pressure plasma surface treatment.

  • PDF

Degradation of Pesticides in Wastewater Using Plasma Process Coupled with Photocatalyst (광촉매를 병합한 플라즈마 공정을 이용한 폐수에 함유된 살충제 분해)

  • Jang, Doo Il;Kim, Kil-Seong;Hyun, Young Jin
    • Applied Chemistry for Engineering
    • /
    • v.24 no.1
    • /
    • pp.87-92
    • /
    • 2013
  • Nonthermal plasma hybridized with photocatalysts is proven to be an effective tool to degrade toxic organics in wastewater. In this study, a specially designed dielectric barrier discharge (DBD) plasma system combined with photocatalysts was applied to decompose pestiticides such as dichlorovos, carbofuran and methidathon, which are frequently used in the golf courses and the orange plantations. The degradations of the pesticides in single and coupled systems were evaluated. The single system was used with ozone plasma which consisted of electrons, radicals, ions produced by oxygen gas and air, with and without ultra-violet (UV) irradiation, respectively. The coupled systems utilized the air-derived ozone plasma combined with zinc oxide, titanium dioxide and graphite oxide photocatalyst activated by UV. The graphite oxide was synthesized by a modified Hummer's method and characterized using FTIR spectrometer. It was elucidated that the plasma reaction with graphite oxide (0.01 g/L) brought about almost 100% of degradation degrees for dichlorovos and carbofuran in 60 min, as compared with the performances showed by no catalyst condition. The photocatalyst-hybridized plasma in the presence of UV irradiation was proven to be an effective alternative for degrading pesticides.

Microbial Decontamination of Black Pepper Powder Using a Commercial-scale Intervention System Combining Ultraviolet-C and Plasma Treatments (Ultraviolet-C와 플라즈마를 병합 처리하는 양산형 살균 시스템을 이용한 후춧가루 미생물 저해)

  • Bang, In Hee;Lee, Seung Young;Han, Kyoon Sik;Min, Sea C.
    • Food Engineering Progress
    • /
    • v.22 no.4
    • /
    • pp.386-391
    • /
    • 2018
  • Effects of a commercial scale intervention system combining ultraviolet (UV)-C and plasma treatments on the microbial decontamination of black pepper powder were investigated. The process parameters include treatment time, time for plasma accumulation before treatment, and water activity of black pepper powder. A significant reduction in the number of indigenous aerobic mesophilic bacteria in black pepper powder was observed after treatments lasted for ${\geq}20min$ (p<0.05) and the reduction was differed by powder manufacturer. The microbial reduction rates obtained by individual UV-C treatment, individual plasma treatment, and UV-C/plasma-combined treatment were 0.2, 0.5, and 1.0 log CFU/g, respectively, suggesting that the efficacy of the microbial inactivation was enhanced by treatment combination. Nonetheless, neither plasma accumulation time nor powder water activity affected the microbial inactivation efficacy of the combined treatment. The UV-C/plasma-combined treatment, however, decreased lightness of black pepper powder, and the decrease generally increased as operation time increased. The plasma accumulation time of 20 min resulted in significant reduction in both lightness and brown color. The results indicate that the commercial-scale intervention system combining treatments of UV-C and plasma has the potential to be applied in the food industry for decontaminating black pepper powder.

Dry cleaning for metallic contaminants removal after the chemical mechanical polishing (CMP) process (Chemical Mechnical Polishing(CMP) 공정후의 금속오염의 제거를 위한 건식세정)

  • 전부용;이종무
    • Journal of the Korean Vacuum Society
    • /
    • v.9 no.2
    • /
    • pp.102-109
    • /
    • 2000
  • It is difficult to meet the cleanliness requirement of $10^{10}/\textrm{cm}^2$ for the giga level device fabrication with mechanical cleaning techniques like scrubbing which is widely used to remove the particles generated during Chemical Mechanical Polishing (CMP) processes. Therefore, the second cleaning process is needed to remove metallic contaminants which were not completely removed during the mechanical cleaning process. In this paper the experimental results for the removal of the metallic contaminants existing on the wafer surface using remote plasma $H_2$ cleaning and UV/$O_3$ cleaning techniques are reported. In the remote plasma $H_2$ cleaning the efficiency of contaminants removal increases with decreasing the plasma exposure time and increasing the rf-power. Also the optimum process conditions for the removal of K, Fe and Cu impurities which are easily found on the wafer surface after CMP processes are the plasma exposure time of 1min and the rf-power of 100 W. The surface roughness decreased by 30-50 % after remote plasma $H_2$ cleaning. On the other hand, the highest efficiency of K, Fe and Cu impurities removal was achieved for the UV exposure time of 30 sec. The removal mechanism of the metallic contaminants like K, Fe and Cu in the remote plasma $H_2$ and the UV/$O_3$ cleaning processes is as follows: the metal atoms are lifted off by $SiO^*$ when the $SiO^*$is evaporated after the chemical $SiO_2$ formed under the metal atoms reacts with $H^+ \; and\; e^-$ to form $SiO^*$.

  • PDF

Comparison of Phenol Removal between Electrochemical Reaction and Plasma Reaction

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.25 no.7
    • /
    • pp.905-916
    • /
    • 2016
  • The characteristics of phenol removal and $UV_{254}$ matters variance were investigated and compared by the variation of operating factors (NaCl concentration, air flow rate, initial phenol concentration) in electrochemical reaction (ER) and dielectric barrier discharge plasma reaction (DBDPR), respectively. The phenol removal rate was shown as $1^{st}$ order both in ER and DBDPR. Also, the absorbance of $UV_{254}$ matters which means aromatic intermediates was analyzed to investigate the complete phenol degradation process. In ER, the phenol degradation and aromatic intermediates production rates increased by the increase of NaCl concentration. However, in DBDPR, the variation of NaCl concentration had no effect on the degradation of phenol and $UV_{254}$ matters. Air flow rate had a little effect on the removal of phenol and the variation of $UV_{254}$ matters in ER. The phenol removal rate in ER was a little higher than that in DBDPR. The produced $H_2O_2$ and $O_3$ amounts in ER were 2 times and 10 times higher than those in DBDPR. The chlorine intermediates ($ClO_2$ and free chlorine) were produced in ER, however, they were not produced in DBDPR.