• 제목/요약/키워드: Plasma test

검색결과 1,364건 처리시간 0.026초

백설기에 첨가된 Guar gum 수준이 혈장 포도당과 인슐린에 미치는 영향 (Effect of Guar gum levels in Backsulgies on Plasma Glucose and Insulin in Healthly Men)

  • 장유경
    • 대한가정학회지
    • /
    • 제32권3호
    • /
    • pp.207-216
    • /
    • 1994
  • Backsulgies containing various levels of guar gum(0g, 2.5g or 5g) were ingested by ten healthy male subjects after 12-h fast. Guar backsulgies was given a time in a week a time in a week for 3 weeks with 75g glucose. The Sensory qualities of backsulgies containing guar gum powder of different levels(0g, 2.5, 5g) were also evaluated using a hedonic scoring technique. On each test day 4ml samples of venous blood were taken from the fasted subjects. Further 4ml post-prandial blood samples were taken from the subjects 30, 60, 90 and 120min after guar backsulgies had commenced. Result were as follows: Plasma glucose and insulin levels were not sifnificantly reduced according to guar gum levels in backsulgies. But plasma glucose and insulin levels of the case which ingested 5g guar backsulgies tended to be lower than those of the case which ingested 0g or 2.5g guar backsulgies. Therefore it is recommended that 5g guar backsulgies is most effective snack of diabetics. KEY WORDS: guar backsulgies plasma glucose, plasma insulin, snack.

  • PDF

스팀처리된 소결강의 플리즈마 질화 및 연질화 특성 (Characteristics of Plasma Nitriding and Nitrocarburizing of Steam Treated Sintered Steels)

  • 박주승
    • 한국분말재료학회지
    • /
    • 제4권4호
    • /
    • pp.268-274
    • /
    • 1997
  • Characteristics of plasma nitriding and nitrocarburizing for steam treated sintered steels were studied. Fe-0.8%C powder containing Ni, Cu were sintered at 112$0^{\circ}C$ and steamed at 52$0^{\circ}C$. Temperature of plasma nitriding and nitrocarburizing was varied from 50$0^{\circ}C$ to $600^{\circ}C$. Gas mixture of nitriding was set at $N_2$ : $H_2$ =80:20 (vol.%), but $CH_4gas$ was added 1~2 vol.% for nitrocarburizing. Steam treatment for sintered steels brought not only the formation of oxide layer but also decarburizing near the surface. Decrease in hardness near the surface resulted from the formation of ferrite due to decarburizing. Thus, the low hardness was recovered not with plasma nitriding but with plasma nitrocarburixing. Wear resistance properties of steamed specimens and ni-trocarburized specimens were better than those of nitrided specimens according to the pin-on-disk wear test. On the other hand, the fatigue life of steamed specimen was shorter than that of nitrocaiburized specimen.

  • PDF

Study on the Adhesive Properties of Polyesters Reinforcing Materials

  • Krump, H.;Hudec, I.;Cernak, M.;Janypka, P.
    • Elastomers and Composites
    • /
    • 제37권3호
    • /
    • pp.192-194
    • /
    • 2002
  • Polyester cord yarns have been treated in an atmospheric-pressure nitrogen plasma reactor in order to enhance their adhesion to rubber. A thin layer or the plasma was generated in the close vicinity of the yam surface using various types or surface discharge. To assess the effect of the plasma treatment on fiber surface properties, the cord thread/rubber matrix adhesion values measured using the untreated and threads cord threads were compared. The static and dynamic adhesion of the cord thread to rubber was characterized by using the standard Henley test. The dynamic adhesion values for the reference and plasma treated fiber were $7,3{\pm}1,2\;N$ and $83,5{\pm}3,5\;N$. The surface properties were investigated by scanning electron microscopy, infrared spectroscopy and electron spin resonance spectroscopy. It is concluded that both polar group interactions and increased surface area of the fibers are responsible for the improved adhesive strength.

크롬/폴리이미드의 접착력에 미치는 폴리이미드 표면의 플라즈마 처리의 효과 (The effects of plasma treatment of polyimide surface on the adhesion of chromium/polyimide)

  • 정태경;김영호;유진
    • 한국표면공학회지
    • /
    • 제26권2호
    • /
    • pp.71-81
    • /
    • 1993
  • Thed effects of Ar or Oxygen RF plasma treatment on the adhesion behavior of Cr films to polyimide sub-strates have been investigated by using SEM, XRD, AES, and $90^{\circ}$peel test. By applying RF plasma treatment of the polyimide surface prior to metal deposition, the peel adhesion strength of Cu/Cr films sputtered onto the fully cured BPDA-PDA polyimide was highly increased from about 3g/mm to 90 ~ 100g/mm. Improved peel adhesion strength of Cr/polyimide interfaces due to RF plasma treatment was attributed to the contributions from surface cleaning, Cr-polyimide bonding at the interface, and force required for plastic deformation of the film. While the surface topology change of the polyimide caused by RF plasma treatment makes a little contri-bution to the improved adhesion.

  • PDF

반도전성 실리콘 고무의 플라즈마 표면처리에 따른 접착특성과 절연성능 (Adhesion and Electrical Performance by Plasma Treatment of Semiconductive Silicone Rubber)

  • 황선묵;이기택;홍주일;허창수
    • 한국전기전자재료학회논문지
    • /
    • 제18권5호
    • /
    • pp.450-456
    • /
    • 2005
  • In this paper, the effect of adhesion properties of semiconductive-insulating interface layer of silicone rubber on electrical properties was investigated. The modifications produced on the silicone surface by oxygen plasma were accessed using ATR-FTIR, contact angle and Surface Roughness Tester. Adhesion was obtained from T-peel tests of semiconductive layer haying different treatment durations. In addition, ac breakdown test was carried out for elucidating the change of electrical property with duration of plasma treatment. From the results, the treatment in the oxygen plasma produced a noticeable increase in surface energy, which can be mainly ascribed to the creation of O-H and C=O. It is observed that adhesion performance was determined by surface energy and roughness level of silicone surface. It is found that at dielectric strength was increased with improving the adhesion between the semiconductive and insulating interface.

$MoO_3$가 첨가된 $Cr_2$$O_3$ 플라스마 용사코팅의 마찰 마멸 특성 (Friction and wear properties of plasma-sprayed $Cr_2$$O_3$/$MoO_3$ composite coatings)

  • 여인웅;안효석;임대순
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2001년도 제33회 춘계학술대회 개최
    • /
    • pp.22-29
    • /
    • 2001
  • Plasma-sprayed coatings were prepared using by spray-dried Cr$_2$O$_3$ powder with and without MoO$_3$ addition. A reciprocal type tribe-tester was employed to examine friction and wear behavior of the specimens at room temperature. The worn surfaces of plasma spray coated specimens were observed by SEM. The results showed that friction coefficient of the MoO$_3$-added coatings were lower than those without MoO3 addition. However pure Cr$_2$O$_3$ coating showed the lowest wear loss at the self-mated test. The larger protecting layers were observed at the worn surface of plasma spray coated specimens with MoO$_3$ addition.

  • PDF

Modified Phillips-Tikhonov regularization for plasma image reconstruction with modified Laplacian matrix

  • 장시원;이승헌;최원호
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.472-472
    • /
    • 2010
  • The tomography has played a key role in tokamak plasma diagnostics for image reconstruction. The Phillips-Tikhonov (P-T) regularization method was attempted in this work to reconstruct cross-sectional phantom images of the plasma by minimizing the gradient between adjacent pixel data. Recent studies about the comparison of the several tomographic reconstruction methods showed that the P-T method produced more accurate results. We have studied existing Laplacian matrix used in Phillips-Tikhonov regularization method and developed modified Laplacian matrix (Modified L). The comparison of the reconstruction result by the modified L and existing L showed that modified L produced more accurate result. The difference was significantly pronounced when a portion of plasma was reconstructed. These results can be utilized in the Edge Plasma diagnostics; especially in divertor diagnostics on tokamak a large impact is expected. In addition, accurate reconstruction results from received data in only one direction were confirmed through phantom test by using P-T method with modified L. These results can be applied to the tangentially viewing pin-hole camera diagnostics on tokamak.

  • PDF

알루미늄 압출용 금형의 플라즈마 표면처리 (Plasma Surface Treatment of Aluminum Extrusion Die)

  • 최인규;이수영;김상호
    • 한국표면공학회지
    • /
    • 제47권6호
    • /
    • pp.282-286
    • /
    • 2014
  • Wear characteristic of the nitrided SKD61 which is a typical mold material using for the extrusion of Al6061 alloy was investigated. The surface of SKD61 was nitrided by salt bath and plasma processes. The thickness of surface nitride layer was about $8.9{\mu}m{\sim}21.3{\mu}m$. Reciprocating friction wear test conducted using pin on disk type indicated the plasma treatment followed salt bath has a lower friction coefficient and a smaller adhesive wear with Al6061 alloy. That was identified by the $Fe_4N$ which has a better wear resistance than FeN mainly formed by plasma nitriding.

Assay of Midazolam in Human Plasma by Gas-Liquid Chromatography with Nitrogen-Phosphorus Detection

  • 신호상;홍춘표;Yun-Suk Oh-Shin;강보경;이경옥;이규범
    • Bulletin of the Korean Chemical Society
    • /
    • 제19권5호
    • /
    • pp.524-526
    • /
    • 1998
  • A sensitive and specific method is described for the determination of midazolam in human plasma. The drug was extracted from 1 mL of carbonate buffered plasma (pH 9.6) with 8 mL of diethyl ether. Famprofazone was used as internal standard. The organic phase was evaporated to dryness. The residue was dissolved in methanol for the direct analysis by gas chromatograph-nitrogen phosphorus detector system. In the concentration range of 1-5000 ng/mL, the calibration curve was linear. The coefficients of variation from the precision test were <6% at the range of the concentration of 0.10-2.00 μg/mL and the detection limit for midazolam in 1 mL of plasma was o.5 ng. This assay is more sensitive, selective, simple and rapid than earlier methods. Plasma midazolam concentrations were determined by this method after administration of midazolam.

구자를 장기간(長期間) 투여(投與) 했을 때 생쥐의 근피로(筋疲勞)와 근력(筋力)에 미치는 영향(影響) (Long Term Effect of Allii tuberosi semen on Muscle Fatigue and Muscular Strength)

  • 조정훈;장준복;이경섭;이창훈
    • 대한한방부인과학회지
    • /
    • 제20권3호
    • /
    • pp.81-90
    • /
    • 2007
  • Purpose: This study was conducted to investigate the muscle anti-fatigue effects of Allii tuberosi semen after long term administration. Materials and Methods: 4-6 weeks old ICR mice were used in this study and we administered the water soluble extracts of Allii tuberosi semen in the concentration of 1, 10 and 100mg/0.3ml to each 5 mice (ATS group) and same volume of normal saline was administered to 5 mice (control group) once a day for 90 or 120 days. After the administration we performed the swimming exercise test and the grip strength test. And we measured the concentration of glucose and the activity of lactate dehydrogenase in plasma regarded as biochemical indicator related with the muscular fatigue. Results: In swimming exercise test, all ATS groups showed increased time compared with relative control group after 90 days administration. But after 120 days adminstration 10 and 100mg/0.3ml ATS groups showed increased results. In grip strength test, all ATS group increased grip strength after 90 days administration and 10mg/0.3ml ATS group showed increased result after 120 days administration. All the results of plasma glucose didn't showed statistically significant difference after 90 and 120 days administration. In the plasma concentration of activity level of lactate dehydrogenase, 1mg/0.3ml and 10mg/0.3ml ATS groups showed decreased concentration compared with relative control group after 90 days administration. But after 120 days adminstration 1mg/0.3ml ATS groups showed decreased results. Conclusion: From this study we could find the anti-fatigue effect of Allii tuberosi semen in the muscle strength related test.

  • PDF