• Title/Summary/Keyword: Plasma light

Search Result 726, Processing Time 0.033 seconds

Effects of light direction and exposure times of plasma arc light on shear bond strength of metal brackets (Plasma arc light를 이용한 금속 브라켓의 부착시 광조사 방향과 중합시간이 전단결합강도에 미치는 영향)

  • Roh, Sang-Jeong;Lee, Hyun-Jung;Jeon, Young-Mi;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.34 no.5 s.106
    • /
    • pp.429-438
    • /
    • 2004
  • The purpose of this study was to compare the effects of different light direction exposure times and setting times when using plasma arc light on shear bond strength of metal brackets. 240 extracted human premolars were randomly assigned to one of 16 groups Standardized brackets were bonded to enamel using different light curing units (Plasma arc light and Halogen light), exposure times (Plasma arc light 2. 4, 6 seconds and Halogen light 20 seconds). and light directions [Vertical direction [V] and Oblique direction [O]). 8 groups were tested after 5 minutes and the remaining 8 groups after 24 hours. The metal brackets were bonded with Transbond XT. Shear bond strength was measured by a universal testing machine. The results were as fellows: There were as differences between the shear bond strengths of the Vertical groups (V) and Oblique groups (O). regardless of exposure times and types of light curing units (p>0.05). The shear bond strength of the group with 2 seconds of plasma light were significantly lower than other exposure time groups (P<0.05). The shear bond strength tested after 5 minutes was lower than after 24 hours (p<0.05) The Adhesive Remment Index (ARI) score showed no statistically significant difference among the different groups. The results of this study suggested that the light direction of plasma arc light had no influence on the shear bond strength of metal brackets to enamel. and exposure times more than 4 seconds produced shear bond strengths similar to those Produced with a conventional halogen curing light.

A STUDY ON THE SHEAR BOND STRENGTH BY PLASMA ARC CURING SYSTEM FOR BRACKET BONDING (Plasma arc curing system을 이용한 브라켓의 접착에 관한 연구)

  • Kim, Jung-Yoon;Kim, Jong-Soo;Kwon, Soon-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.638-642
    • /
    • 2001
  • Recently, plasma arc curing system for curing resin composites has been introduced. This is characterized by a high output of light energy, which has the advantage of reducing the chair time and thereby making the treatment more comportable for the patients as well as for the dentist. The purpose of this study was to compare the shear bond strengths of light-cured orthodontic adhesive polymerized with conventional halogen light and plasma arc light. The 2 curing devices used were the XL3000 (3M, USA) conventional curing light and the Flipo (LOKKI, France) plasma arc light. The results from the present study can be summarized as fellows; 1. The mean shear bond strength for three groups were quite similar for 50 second conventional light group, 2 second plasma arc curing light group, 5 second plasma arc curing light group. 2. There was no statistically significant difference for three groups(p>0.05).

  • PDF

The shear bond strength and adhesive failure pattern in bracket bonding with different light-curing methods (브라켓 접착시 광중합방식에 따른 전단결합강도와 파절양상 비교)

  • Shin, Jai-Ho;Lim, Yong-Kyu;Lee, Dong-Yul
    • The korean journal of orthodontics
    • /
    • v.34 no.4 s.105
    • /
    • pp.333-342
    • /
    • 2004
  • The purpose of this study was to evaluate the clinical effectiveness of a plasma arc light and light emitting diode (LED), compared with shear bond strength and the failure pattern of brackets bonded with visible light in direct bonding. Brackets were bonded with Transbond XT to 60 human premolars embedded in the resin blocks according to different light-curing methods. Then, the shear bond strength of each group was measured using a universal testing machine (Instron) and the adhesive failure pattern after debonding was visually examined by light microscope. The results were as follows: 1. The shear bond strength showed no significant difference between the visible light and light emitting diode, but the plasma arc light exhibited a significantly lower shear bond strength compared with the visible light and light emitting diode. 2. In the visible light and light emitting diode, adhesive failure patterns were similar. Bond failure occurred more frequently at the enamel-adhesive interface. 3. The bonding failure of brackets bonded with plasma arc light occurred more frequently at the bracket-adhesive interface. The results of this study suggest that plasma arc light, light emitting diode and visible light are all clinically useful in the direct bonding of orthodontic brackets.

Changes of plasma melatonin level and testis weight in the seasonal light-period

  • Han, Sang-Zin
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2003.05a
    • /
    • pp.160-160
    • /
    • 2003
  • Plasma melatonin in the seasonal light-period is circadian rhythmically secreted. Maximal secretion showed at 14 o'clock in summer- and winter-like period, but minimal secretion showed at 5 o'clock in summer-like period and at 8 in winter-like period. These times of minimal secretions were at the beginning of light period. Plasma melatonin in the light period is secreted 62.5% more than in the dark period in summer-like period and 45.9% more in winter-like period. Total plasma melatonin in winter-like period is secreted 56.5% more than in summer-like period. The weights of testis(-20.8%) and body(-7.1%) were reduced in the winter-like period. By the increase of plasma melatonin in mice, body- and testis-weights are decreased, on the contrary by the decrease of plasma melatonin in mice, body and testis weights are increased. In view of the results so far achieved melatonin changes on the body weight and reproductive organ in mice. It is presumed that melatonin effects on the metabolism and sex hormone.

  • PDF

Changes of Plasma Melatonin Level and Testis Weight in Mice in the Seasonal Light-period (인위적인 계절적 광주기에서 쥐에 나타나는 멜라토닌 분비양상과 정소크기변화 조사)

  • 한상진
    • Environmental Analysis Health and Toxicology
    • /
    • v.18 no.1
    • /
    • pp.57-61
    • /
    • 2003
  • Plasma melatonin in the seasonal light-period is circadian rhythmically secreted. Maximal secretion showed at 14 o'clock in summer- and winter-like period, but minimal secretion showed at 5 o'clock in summer-like period and at 8 in winter-like period. These times of minimal secretions were at the beginning of light period. Plasma melatonin in the light period is secreted 62.5% more than in the dark period in summer- like period and 45.9% more in winter- like period. Total plasma melatonin in winter-like period is secreted 56.5% more than in summer-like period. The weights of testis (-20.8%) and body (-7.1%) were reduced in the winter-like period. By the increase of plasma melatonin in mice, body - and testis -weights are decreased, on the contrary by the decrease of plasma melatonin in mice, body and testis weights are increased. In view of the results so far achieved melatonin changes on the body weight and reproductive organ in mice. It is presumed that melatonin effects on the metabolism and sex hormone.

Study on the Nonlinear Interaction of Laser with Plasma -Detection of Second Harmonic Light and Brillouin Scattering Light by Means of Spectroscopic Technique- (레이저와 프라즈마와의 비선형상오작용에 관한 연구 -분광법에 의한 제 2고주파와 Brillouin 산람광의 검출-)

  • Kang, Hyung-Boo
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.5
    • /
    • pp.173-180
    • /
    • 1984
  • The spectra of scattering light fromlaser-produced plasma near its fundamental and second harmonic wavelength were observed respectively by means of spectroscopic technique. The experimental results and the generation mechanism of nonlinear effects such as the second garmonics and the brillouin scattering were analysed theoretically. The spectra of reflected laser light became wider than that of incident laser light. And the peak of spectrum of reflected light shifted to red-side from that of incident light. The second harmonic light is generated from the nonlinear interaction of the incident laser light and the electron plasma wave excited in resonance region by the oblique incidence of laser light to the plasma. The Brillouin backscattering from laser-produced plasmas of hydrogen and deuterium has shown an isotope effect in the red-side region of the generated second harmonic light. This isotope shift is explained by the parametric instability at the cutoff (resonance) region using frequency-and phase-matching conditions of the waves.

  • PDF

Shear bond strength and adhesive failure pattern in bracket bonding with plasma arc light (Plasma arc light를 이용한 bracket 부착시의 전단결합강도와 파절양상의 유형)

  • Yoo, Hyung-Seok;Oh, Young-Geun;Lee, Seung-Yeon;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.31 no.2 s.85
    • /
    • pp.261-270
    • /
    • 2001
  • The purpose of this study was to evaluate the clinical usefulness of plasma arc light which can reduce the curing time dramatically compared by shear bond strengths and failure patterns of the brackets bonded with visible light in direct bracket bonding. Some kinds of brackets were bonded with the Transbond$^{\circledR}$ to the human premolars which were embedded in the resin blocks according to the various conditions. After bonding, the shear bond strength was tested by Instron universal testing machine and in addition , the amount of residual adhesive remaining on the tooth after debonding was measured by the stereoscope and assessed with adhesive remnant index(ARI). The results were as follows : 1. When plasma arc light was used for bonding the brackets, the shear bond strength was clinically sufficient in both metal and ceramic brackets, but resin brackets showed significantly lower bond strength but which was clinically useful. 2. When metal brackets were bonded using visible light, there was no significant difference in shear bond strength due to the light-curing time and the bond strength was clinically sufficient. 3. When the adhesive failure patterns of brackets bonded with plasma arc light were observed by using the adhesive remnant index, the bond failure of the metal and resin bracket occurred more frequently at bracket-adhesive interface but the failure of the ceramic bracket occurred more frequently at enamel-adhesive interface. 4. There was no statistically significant difference of the shear bond strength and adhesive failure pattern between metal bracket bonded for 2 seconds by curing with plasma arc light and 10 seconds by curing with visible light. 6. When metal brackets were bonded using plasma arc light, the shear bond strength decreased as the distance from the light source increased. The above results suggest that plasma arc light can be clinically useful for bonding the brackets without fear of the decrease of the shear bond strength.

  • PDF

Application of plasma lighting for growth and flowering of tomato plants

  • Park, Kyoung Sub;Kim, Sung Kyeom;Lee, Sang Gyu;Lee, Hee Ju;Kwon, Joon Kook
    • Horticulture, Environment, and Biotechnology : HEB
    • /
    • v.59 no.6
    • /
    • pp.827-833
    • /
    • 2018
  • Plasma lighting systems have been engineered to simulate sunlight. The objective of this study was to determine the effects of plasma lighting on tomato plant growth, photosynthetic characteristics, flowering rate, and physiological disorders. Tomato plants were grown in growth chambers at air temperatures of $25/23^{\circ}C$ (light/dark period), in a $16h\;day^{-1}$ light period provided by four different light sources: 1 kW and 700 W sulfur plasma lights (1 SPL and 0.7 SPL), 1 kW indium bromide plasma light, and 700 W high pressure sodium lamp (0.7 HPS) as a control. The totaldry weight and leaf area at 0.7 SPL were approximately 1.2 and 1.3 times greater, respectively, than that of 0.7 HPS at the 62 days after sowing (DAS). The maximum light assimilation rate was observed at 1 SPL at the 73 DAS. In addition, the light compensation and saturation points of the plants treated with plasma lighting were 98.5% higher compared with HPS. Those differences appeared to be related to more efficient light interception, provided by the SPL spectrum. The percentage of flowering at 0.7 SPL was 30.5%, which was higher than that at 0.7 HPS; however, there were some instances of severe blossom end rot. Results indicate that plasma lighting promotes tomato growth, flowering, and photosynthesis. Therefore, a plasma lighting system may be a valuable supplemental light source in a greenhouse or plant factory.

A Study of Non-thermal Plasma Generation on a Photocatalytic Reactor Using a Ceramic Honeycomb Monolith Substrate (세라믹 벌집형 담체를 사용한 광촉매 반응기의 플라즈마 생성에 관한 연구)

  • 손건석;윤승원;고성혁;김대중;송재원;이귀영
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.2
    • /
    • pp.48-54
    • /
    • 2002
  • Since photocatalysts are activated by lights of UV wavelengths, plasma is alternatively used as a light source for a photocatalytic reactor. Light intensity generated by plasma is proportional to the surface area of catalytic material, and this, in many practical applications, is prescribed by the geometry of a plasma generator. Thus, it is crucial to increase the surface area far sufficient light intensity for photocatalytic reaction. For example, in a pack-bed type reactor, multitudes of beads are used as a substrate in order to increase the surface area. Honeycomb monolith type substrate, which has very good surface area to volume ratio, has been difficult to apply plasma as a light source due to the fact that light penetration depth through the honeycomb monolith was too short to cover sufficient area, thus resulting in poor intensity for photocatalytic reaction. In this study, nonthermal plasma generation through a photocatalytic reactor of honeycomb monolith substrate is investigated to lengthen this short penetration depth. The ceramic honeycomb monolith substrate used in this study has the same length as a three way catalyst used fur automotive applications, and it is shown that sufficient light intensity for photocatalytic reaction can also be obtained with honeycomb monolith type reactor.

In-Line Hologram for Plasma Diagnostics

  • Kim, Byungwhan;Jung, Jin-Su
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.4
    • /
    • pp.524-529
    • /
    • 2016
  • Diagnostic sensors are demanded during plasma processes. Holograms of plasma taken with laser light without a reference beam were used to monitor behaviors of charged particles produced in nitrogen plasma as a function of electrode temperature ranging between 50 and 300℃. Holograms were characterized as a function of the pixel sum and grayscale value. Pixel sum calculated in identified grayscale ranges strongly correlated with ion density and emitted light intensity measured with a langmuir probe and optical emission spectroscopy, respectively. The performance was further evaluated with data acquired as a function of N2 and NH3 flow rates and improved correlations were observed in the new grayscale range. The confirmed correlations indicate that a hologram is a viable means to diagnose behaviors of plasma particles such as ions. Underlying principles are discussed in view of particle and charge composing vacuum and light.