• Title/Summary/Keyword: Plasma diagnosis

Search Result 345, Processing Time 0.034 seconds

Studies on the Rapid Plasma Reagin(RPR) Card Test for the Diagnosis of Syphilis (매독진단(梅毒診斷)을 위(爲)한 신속(迅速)한 혈장항체검사법(血漿抗體檢査法)에 관(關)한 연구(硏究))

  • Kim, Joo-Deuk;Lew, Joon;Kim, Hyun-Joo
    • The Journal of the Korean Society for Microbiology
    • /
    • v.3 no.1
    • /
    • pp.15-23
    • /
    • 1968
  • For the effective control of Syphilis, many investigators have developed a more rapid, simple and economical screening serological test which is adequately sensitive and specific. To fulfill the requirements of a more rapid serologic test for syphlis, a substitute for the conventional serum specimen was needed since considerable time and labor are involved in the processing of blood to serum. Burdon suggested the use of plasma in the serologic tests for syphilis as a substitute for serum. He noticed that plasma was more sensitive than serum in the Kline and Kahn tests, and attributed this to the presence of more antibody-like substance, "reagin" in plasma than in serum. However, to make plasma sufficiently sensitive, it was necessary to inactivate plasma by heating at a temperature of $56^{\circ}C$ for about 30 minutes. Heating of plasma resulted in the precipitation of fibrinogen which made centrifugation necessary to obtain dear plasma. Since the chief disadvantage to the use of unheated plasma(or serum) was a reduction in sensitivity of results-which probably was due to a labile factor such as complement-Portnoy et al began to consider rapid chemical methods of inactivation of plasma(or serum). They experienced that choline chloirde was shown to be anticomplementary which suggested its use as an inactivating agent for unheated plasma(or serum). In 1959 Portnoy et al reported the Rapid Plasma Reagin(RPR) Test for syphilis which is a more rapid, economical and simple. But still this test has many disadvantages as a rapid performing, field and office procedure, because it requires the usual laboratory equipments such as centrifuge, rotating machine, microscope etc. To substitute these disadvantages of the RPR test, in 1962, Portnoy et al developed the Rapid Plasma Reagin(RPR) card test for syphilis, which has the following advantages: a) Simplicity and rapidity of performance, b) Requires no laboratory equipments, c) Stable antigen suspension, d) Adequate sensitivity and specificity. This RPR card test can be used as a rapidly performing and screening test in field investigation, outpatient clinics, small laboratories and hospitals doing limited syphilis serology, and predonor in blood bank. Private clinic which has limited laboratory equipment and technic for syphilis serology can also use this RPR card test as a tool in the rapid diagnosis of syphilis. It was thought that this RPR card test is a useful tool in Korea for private physician and mass survey for syphilis diagnosis. But Portnoy patented the reagents needed for the performing the RPR card test. Therefore authors developed newly the reagents and according to Portnoy's method evaluated the newly developed. RPR card test compared with the VDRL, Kolmer CF, and RPCF tests. The RPR card and VDRL tests were performed plasma and serum from the total 1,132 cases. Among these 1,131 cases, 521 were syphilis suspected laboratory specimens, and 611 were syphilis unsuspected healthy young men. After screening with these two tests, the RPR card and VDRL tests, reactive specimens to the above one or both tests were retested by the Kolmer CF and RPCF tests.

  • PDF

PLASMA AND MILK PROGESTERONE CONCENTRATIONS AND EARLY PREGNANCY IN ZEBU COWS

  • Alam, M.G.S.;Ghosh, A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.7 no.1
    • /
    • pp.131-136
    • /
    • 1994
  • In an effort to confirm true oestrus and to detect early pregnancy in Zebu cows (Bos indicus), sequential blood and milk samples were collected at the day of imsemination (Day 0) and days 14, 20 and 24 after insemination. Progesterone was determined in skimmed milk and plasma by solid phase radioimmunoassay (RIA). Of the cows thought to be in oestrus plasma, (n = 46) and milk (n = 58) samples demonstrated low progesterone concentrations ($0.99{\pm}0.11$ and $2.02{\pm}0.14nmol/l$) in 42 (91%) and 52 (90%) cases respectively. Thirty two (76%) and 30 (71%) cows were thought to be pregnant by plasma progesterone RIA ($20.23{\pm}1.03$ and $20.48{\pm}1.01nmol/l$) at days 20 and 24 respectively. At the same period, 40 (77%) and 37 (71%) cows were thought to be pregnant by milk progesterone RIA ($27.82{\pm}1.28$and $28.02{\pm}1.27nmol/l$). Assuming 100% accuracy for rectal examination of pregnancy diagnosis between days 60-65 postservice, the RIA was found to be 84% and 90% accurate for plasma and 84% and 92% accurate for milk at day 20 and 24, respectively. All cows thought to be non pregnant by progesterone measurement were correctly diagnosed. Progesterone assay at 24 days after oestrus may therefore be accurate for early diagnosis of pregnancy in Zebu cows.

PLASMA DIAGNOSIS OF FANING TARGETS SPUTTERING SYSTEM FOR DEPOSITION OF BA FERRITE FILMS IN Ar, Xe AND $O_2$ GAS MIXTURE

  • Matsushita, Nobuhiro;Noma, Kenji;Nakagawa, Shigeki;Naoe, Masahiko
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.6
    • /
    • pp.834-838
    • /
    • 1996
  • The diagnosis of the plasma in the facing targets sputtering system was performed in mixture gas of Ar 0.18-0.0 Pa, Xe 0.0-0.18 Pa and $O_2$ 0.02 Pa by using Langmiur's probe and the effect of plasma-damage to surface smoothness and magnetic characteristics of Ba ferrite films was clarified. The electron density $N_e$ and the electron temperature $T_e$ were evaluated at the center of the plasma and at the neighborhood of the anode ring. $T_e$ decreased and $N_e$ increased with increase of $P_{Xe}$ at the center of plasma. For the measurement at the neighborhood of the anode ring, $T_e$ was almost constant and $N_e$ took the minimum value at $P_{Xe}$ of 0.1 Pa, where Ba ferrite films with excellent c-axis orientation and magnetic characteristics were obtained. It was suggested that the restriction of the bombardment of recoiled particles as well as the suppress of plasma-damage were effective for obtaining good surface smoothness and excellent magnetic characteristics and it was useful for decreasing the crystallization temperature of Ba ferrite films.

  • PDF

The Characteristics of Glow Discharge Plasma Diagnosis (글로우 방전 플라즈마 진단 특성)

  • Woo, Sung-Hun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.372-375
    • /
    • 2009
  • We have studied on plasma diagnosis, characteristics of the glow discharge at the several different conditions of pressure, discharge current and such. The discharge onset voltage and onset current decreased as pressure increase, the general trend was nearly in agreement with the left regions of Paschen's curve. As normal glow discharge, discharge voltage was constant according to discharge current.

  • PDF

A Rapid, Simple Determination of Sulfur-containing Compounds and Methylmalonic Acid on Plasma using GC-MS-SIM for the Diagnosis of Homocysteinemia (혈장 중 황함유 화합물과 메틸말론산의 신속 간편한 분석법 개발; GC-MS-SIM을 이용한 호모시스테인혈증의 진단)

  • Yoon, Hye-Ran;Thapa, Maheshwor
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.15 no.3
    • /
    • pp.138-146
    • /
    • 2015
  • Purpose: If early diagnosis is not made, patients with metabolic disorders as homocystinemia rapidly progress to physical defect or mental retardation resulted in storage of the toxic material into the brain. Therefore, it is necessary to develop an analytical method for a rapid screening and/or correct confirmation diagnosis. Methods: The standard solution of sulfur amino acids spiked plasma was subjected to protein precipitation with methanol, and then consecutively derivatized with trimethylsilyl (TMS) and trifluoroacyl (TFA) and determined by GC-MS. The formation of TMS derivative of the hydroxyl and TFA derivative of amino functional group was performed by BSTFA and MBTFA, respectively. Selective ion monitoring (SIM) mode was used for quantification with selected specific ions. Results: A calibration curve on standard spiked pooled plasma showed a linear relationship with correlation coefficient of 0.9936-0.9992 for all compounds over the range of 0.1-300 ng. The precision and accuracy were within S.D. of 1-15% and RSD of 1-15% for intra-day assay at 2 ng/mL, 15 ng/mL and 30 ng/mL. LOD and LOQ was 0.4 ng/mL and 4 ng/mL respectively. Conclusion: A rapid analytical method was developed to quantify sulfur amino acids and methyl malonic acid, after two-step derivatization procedure with good sensitivity and specificity on human plasma. Advantages of a new method are simplicity and rapidity. The method could be useful for routine analysis, diagnosis of homocysteinemia.

Modular Backpropagation Network to Diagnosing Plasma Processing Equipment

  • Kim, Byungwhan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.32.5-32
    • /
    • 2002
  • Processing plasmas are playing a crucial role in either depositing thin films or etching fine patterns. Any variability in process factors (such as radio frequency power or pressure) can cause a significant shift in plasma state. When this shift becomes large enough to change operating condition beyond an acceptable level, overall product quality can greatly be jeopardized. Thus, timely and accurate diagnosis of plasma malfunction is crucial to maintaining device yield and throughput. Many diagnostic systems have been developed, including HIPOCRATES [1] and PIES [2]. Plasma equipment was also diagnosed by combining neural network and expert system called Dempster-Schafer Theory [3]. A fact c...

  • PDF

Plasma Monitoring by Multivariate Analysis Techniques (다변량 분석기법을 통한 플라즈마 공정 모니터링 기술)

  • Jang, Haegyu;Koh, Kyongbeom;Lee, Honyoung;Chae, Heeyeop
    • Vacuum Magazine
    • /
    • v.2 no.4
    • /
    • pp.27-32
    • /
    • 2015
  • Plasma diagnosis and multivariate analysis techniques for plasma processes are reviewed. The principles and applications of optical emission spectroscopy (OES) and VI probe are discussed briefly. The research results of principal component analysis (PCA), one of the widely used multivariate analysis techniques for plasma process monitoring is discussed in this article.

Electrical Characteristic and Optical Diagnosis for Atmospheric Direct Plasma Jet

  • Hong, Seong In;Ghimire, B.;Hong, Young Jun;Choi, Eun Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.155.1-155.1
    • /
    • 2015
  • Nowadays, Plasma has been used in biological, medical such as wound healing, plant grow, killing cancer. When plasma generated, UV light and ROS(Reactive oxygen species), RNS(Reactive nitrogen species) can generated and those things effect to biological material. So we made simple plasma device using needle type of electrode and generated plasma. We used three kinds of gas and measured applied voltage and current. Also we observed optical emission spectrum. Using deuterium ramp, we can observed absorption spectrum and calculated radical density by lambert-beer's law. It is around ~1016cm3. And we can see the time-resolved absorption spectrum from monochromator, PMT(photo multiply tube), IV-converter, oscilloscope.

  • PDF

Chamber Monitoring with Residual Gas Analysis with Self-Plasma Optical Emission Spectroscopy

  • Jang, Hae-Gyu;Lee, Hak-Seung;Park, Jeong-Geon;Chae, Hui-Yeop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.262.2-262.2
    • /
    • 2014
  • Plasma processing is an essential process for pattern etching and thin film deposition in nanoscale semiconductor device fabrication. It is necessary to maintain plasma chamber in steady-state in production. In this study, we determined plasma chamber state with residual gas analysis with self-plasma optical emission spectroscopy. Residual gas monitoring of fluorocarbon plasma etching chamber was performed with self-plasma optical emission spectroscopy (SPOES) and various chemical elements was identified with a SPOES system which is composed of small inductive coupled plasma chamber for glow discharge and optical emission spectroscopy monitoring system for measuring optical emission. This work demonstrates that chamber state can be monitored with SPOES and this technique can potentially help maintenance in production lines.

  • PDF

Inflammatory Cytokine Level in Patients with Obstructive Sleep Apnea and Treatment Outcome of Oral Appliance Therapy

  • Oh, Jae-Tak;Chung, Jin-Woo
    • Journal of Oral Medicine and Pain
    • /
    • v.41 no.3
    • /
    • pp.126-132
    • /
    • 2016
  • Purpose: The aims of this study were to analyze the association between inflammatory cytokine and obstructive sleep apnea (OSA), and to evaluate treatment outcome and changes of plasma inflammatory cytokine levels after oral appliance therapy. Methods: Twenty-seven subjects who visited Department of Oral Medicine in Seoul National University Dental Hospital were performed nocturnal polysomnography and analyzed plasma C-reactive protein (CRP), interleukin (IL)-$1{\beta}$, IL-6, IL-10, and tumor necrosis factor (TNF)-${\alpha}$ levels. Each subject was evaluated with Pittsburgh Sleep Quality Index (PSQI) and Epworth Sleepiness Scale (ESS). The subjects were classified into 12 OSA patients (apnea-hypopnea index [AHI] >5) and 15 control (AHI ${\leq}5$) groups. The OSA group was treated with mandibular advancement device (MAD) for 3 months and re-evaluated nocturnal polysomnography and plasma inflammatory cytokine levels. Results: Plasma TNF-${\alpha}$, IL-10, and IL-6 levels were significantly higher in OSA patients compared to controls. Total AHI showed significant positive correlations with plasma IL-6 and TNF-${\alpha}$ levels. Percentage time of $SpO_2$ <90 and lowest $SpO_2$ were significantly correlated with plasma TNF-${\alpha}$ level. ESS showed significant positive correlation with plasma IL-10 level. Total AHI, percentage time of $SpO_2$ <90, lowest $SpO_2$, and mean $SpO_2$ were significantly improved after the MAD therapy. Plasma TNF-${\alpha}$ level was significantly decreased after MAD therapy. Conclusions: We suggest that MAD therapy is an effective treatment modality for patients with OSA and can decrease plasma cytokine level.