• Title/Summary/Keyword: Plasma Irradiation

Search Result 149, Processing Time 0.039 seconds

Effect of Gamma-Irradiation on the Molecular Properties of Blood Plasma Proteins

  • Song, Kyung-Bin;Lee, Seunghwan;Lee, Seunghyun
    • Preventive Nutrition and Food Science
    • /
    • v.7 no.2
    • /
    • pp.184-187
    • /
    • 2002
  • Blood products from slaughterhouses that are not hygienically prepared for disposal or food consumption pose a human health hazard. Gamma irradiation is an effective method for sterilization of blood products, but may introduce changes in the molecular characteristics of proteins. This study evaluated the effects of irradiation on animal plasma proteins. Bovine and porcine blood was obtained from a slaughterhouse and the plasma proteins purified and lyophilized. The secondary structure and molecular weight distribution of the plasma protein solutions and powders were examined after ${\gamma}$-irradiation at 1, 5, 7 and 10 kGy. Gamma-irradiation affected the molecular properties of the protein solutions, but not the protein powders. Circular dichroism and sodium dodecyl sulfate-polyacrylamide gel electrophoresis studies showed that increased doses of ${\gamma}$-irradiation decrease the ordered structure of plasma proteins in solution, and cause initial fragmentation of the polypeptide chains and subsequent aggregation.

Hydrophilic Modification of Polypropylene Hollow Fiber Membrane by Dip Coating, UV Irradiation and Plasma Treatment

  • Kim Hyun-Il;Kim Jin Ho;Kim Sung Soo
    • Korean Membrane Journal
    • /
    • v.7 no.1
    • /
    • pp.19-27
    • /
    • 2005
  • PP hollow fiber membrane was hydrophilized by EVOH dip coating followed by low temperature plasma treatment and UV irradiation. EVOH coating attained high water flux without any prewetting but its stability did not guaranteed at high water permeation rate. At high water permeation rate, water flux declined gradually due to swelling and delamination of the EVOH coating layer causing pore blocking effect. However, plasma treatment reduces the swelling, which suppress delamination of the EVOH coating layer from PP support result in relieving the flux decline. Also, UV irradiation helped the crosslinking of the EVOH coating layer to enhance the performance at low water permeation rate. FT-IR and ESCA analyses reveal that EVOH dip coating performed homogeneously through not only membrane surface but also matrix. Thermogram of EVOH film modified plasma treatment and W irradiation show that crosslinking density of EVOH layer increased. Chemical modification by plasma treatment and UV irradiation stabilized the hydrophilic coating layer to increase the critical flux of the submerged membrane.

Deuterium ion irradiation impact on the current-carrying capacity of DI-BSCCO superconducting tape

  • Rajput, M.;Swami, H.L.;Kumar, R.;Bano, A.;Vala, S.;Abhangi, M.;Prasad, Upendra;Kumar, Rajesh;Srinivasan, R.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2586-2591
    • /
    • 2022
  • In the present work, we have irradiated the DI-BSCCO superconducting tapes with the 100 keV deuterium ions to investigate the effect of ion irradiation on their critical current (Ic). The damage simulations are carried out using the binary collision approximation method to get the spatial distribution and depth profile of the damage events in the high temperature superconducting (HTS) tape. The point defects are formed near the surface of the HTS tape. These point defects change the vortex profile in the superconducting tape. Due to the long-range interaction of vortices with each other, the Ic of the tape degrades at the 77 K and self magnetic field. The radiation dose of 2.90 MGy degrades the 44% critical current of the tape. The results of the displacement per atom (dpa) and dose deposited by the deuterium ions are used to fit an empirical relation for predicting the degradation of the Ic of the tape. We include the dpa, dose and columnar defect terms produced by the incident particles in the empirical relation. The fitted empirical relation predicts that light ion irradiation degrades the Ic in the DI-BSCCO tape at the self field. This empirical relation can also be used in neutron irradiation to predict the lifetime of the DI-BSCCO tape. The change in the Ic of the DI-BSCCO tape due to deuterium irradiation is compared with the other second-generation HTS tape irradiated with energetic radiation.

LOW TEMPERATURE DEPOSITION OF SILICON OXIDE FILMS BY UV-ASSOSTED RF PLASMA-ENHANCED CVD

  • Hozumi, Atsushi;Sugimoto, Nobuhisa;Sekoguchi, Hiroki;Takai, Osamu
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.6
    • /
    • pp.773-780
    • /
    • 1996
  • Silicon oxide films were prepared by using five kinds of organosilicon compound as gas sources without oxygen by rf plasma-enhanced CVD (PECVD). UV light was irradiated on a substrate vertically during deposition to enhance film oxidation and ablation of carbon contamination in a deposited films. Films prepared with UV irradiation contained less carbon than those prepared without UV irradiation. The oxidation of the films was improved by UN irradiation. The effect of UV irradiation was, however, not observed when the films were prepared with tetramethy lsilane (TMS) which contained no oxygen atom. Dissociated oxygen atoms from an organosilicon compound were excited in the plasma with UV irradiation around the substrate surface and affected the enhancement of film oxidation and ablation of carbon in the films.

  • PDF

Micro-Spot Atmospheric Pressure Plasma Production for the Biomedical Applications

  • Hirata, T.;Tsutsui, C.;Yokoi, Y.;Sakatani, Y.;Mori, A.;Horii, A.;Yamamoto, T.;Taguchi, A.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.44-45
    • /
    • 2010
  • We are currently conducting studies on culturing and biocompatibility assessment of various cells such as neural stem cells and induced pluripotent stem cells(IPS cells) on carbon nanotube (CNT), on nerve regeneration electrodes, and on silicon wafers with a focus on developing nerve integrated CNT based bio devices for interfacing with living organisms, in order to develop brain-machine interfaces (BMI). In addition, we are carried out the chemical modification of carbon nanotube (mainly SWCNTs)-based bio-nanosensors by the plasma ion irradiation (plasma activation) method, and provide a characteristic evaluation of a bio-nanosensor using bovine serum albumin (BSA)/anti-BSA binding and oligonucleotide hybridization. On the other hand, the researches in the case of "novel plasma" have been widely conducted in the fields of chemistry, solid physics, and nanomaterial science. From the above-mentioned background, we are conducting basic experiments on direct irradiation of body tissues and cells using a micro-spot atmospheric pressure plasma source. The device is a coaxial structure having a tungsten wire installed inside a glass capillary, and a grounded ring electrode wrapped on the outside. The conditions of plasma generation are as follows: applied voltage: 5-9 kV, frequency: 1-3 kHz, helium (He) gas flow: 1-1.5 L/min, and plasma irradiation time: 1-300 sec. The experiment was conducted by preparing a culture medium containing mouse fibroblasts (NIH3T3) on a culture dish. A culture dish irradiated with plasma was introduced into a $CO_2$-incubator. The small animals used in the experiment involving plasma irradiation into living tissue were rat, rabbit, and pick and are deeply anesthetized with the gas anesthesia. According to the dependency of cell numbers against the plasma irradiation time, when only He gas was flowed, the growth of cells was inhibited as the floatation of cells caused by gas agitation inside the culture was promoted. On the other hand, there was no floatation of cells and healthy growth was observed when plasma was irradiated. Furthermore, in an experiment testing the effects of plasma irradiation on rats that were artificially given burn wounds, no evidence of electric shock injuries was found in the irradiated areas. In fact, the observed evidence of healing and improvements of the burn wounds suggested the presence of healing effects due to the growth factors in the tissues. Therefore, it appears that the interaction due to ion/radicalcollisions causes a substantial effect on the proliferation of growth factors such as epidermal growth factor (EGF), nerve growth factor (NGF), and transforming growth factor (TGF) that are present in the cells.

  • PDF

A Study on the UV Degradation Characteristics of FRP by Plasma Surface Modification (플라즈마 표면개질에 따른 FRP의 자외선 열화 특성에 관한 연구)

  • Hwang, Myung-Hwan;Lim, Kyung-Bum
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.3
    • /
    • pp.122-126
    • /
    • 2006
  • In this study, composite materials were put to dry interfacial treatment by use of plasma technology It has been presented that the optimum parameters for the best wettability of the samples at the time of generation of plasma were oxygen atmosphere, 0.1 Torr of system pressure, 100 W of discharge power, and 3 minutes of discharge time. The decrease in surface potential of charged samples by corona discharge indicates that the amount of accumulated electrical charges reduces and the charges that have been injected lessen rapidly when the duration of UV irradiation increases. The surface resistivity and the tensile strength of plasma treated samples, a longer UV irradiation time resulted in decreased insulation.

Neutron irradiation impact on structural and electrical properties of polycrystalline Al2O3

  • Sunil Kumar;Sejal Shah;S. Vala;M. Abhangi;A. Chakraborty
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.402-409
    • /
    • 2024
  • High energy neutron irradiations impact on structural and electrical properties of alumina are studied with particular emphasis on real time in-situ radiation induced conductivity measurement in low flux region. Polycrystalline Al2O3 samples are subjected to high energy neutrons produced from D-T neutron generator and Am-Be neutron source. 14 MeV neutrons from D-T generator are chosen to study the role of fast neutron irradiation in the structural modification of samples. Real time in-situ electrical measurement is performed to investigate the change in insulation resistance of Al2O3 due to radiation induced conductivity at low flux regime. During neutron irradiation, a significant transient decrease in insulation resistance is observed which recovers relative higher value just after neutron exposure is switched off. XRD results of 14 MeV neutron irradiated samples suggest annealing effect. Impact of relatively low energy neutrons on the structural properties is also studied using Am-Be neutrons. In this case, clustering is observed on the sample surface after prolonged neutron exposure. The structural characterizations of pristine and irradiated Al2O3 samples are performed using XRD, SEM, and EDX. The results from these characterizations are analysed and interpreted in the manuscript.

Development of a low energy ion irradiation system for erosion test of first mirror in fusion devices

  • Kihyun Lee;YoungHwa An;Bongki Jung;Boseong Kim;Yoo kwan Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.70-77
    • /
    • 2024
  • A low energy ion irradiation system based on the deuterium arc ion source with a high perveance of 1 µP for a single extraction aperture has been successfully developed for the investigation of ion irradiation on plasma-facing components including the first mirror of plasma optical diagnostics system. Under the optimum operating condition for mirror testing, the ion source has a beam energy of 200 eV and a current density of 3.7 mA/cm2. The ion source comprises a magnetic cusp-type plasma source, an extraction system, a target system with a Faraday cup, and a power supply control system to ensure stable long time operation. Operation parameters of plasma source such as pressure, filament current, and arc power with D2 discharge gas were optimized for beam extraction by measuring plasma parameters with a Langmuir probe. The diode electrode extraction system was designed by IGUN simulation to optimize for 1 µP perveance. It was successfully demonstrated that the ion beam current of ~4 mA can be extracted through the 10 mm aperture from the developed ion source. The target system with the Faraday cup is also developed to measure the beam current. With the assistance of the power control system, ion beams are extracted while maintaining a consistent arc power for more than 10 min of continuous operation.

Research on the Apoptotic Death of Melanoma by the irradiation of Micro Plasma (마이크로 플라즈마를 이용한 피부암 세포의 자연사 유도 연구)

  • Shon, C.H.;Kim, G.C.;Lee, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.220-221
    • /
    • 2007
  • Micro plasma has been recently studied to investigate the effects on various cells. We study a micro-plasma produced by a plasma needle that is operated with RF power and its effects on G361 melanoma cells. The micro plasma size ranges from sub-mm to several mm at a few watts of RF power. For the bio-medical treatment, low-temperature plasma is obtained and gas temperature is controlled within several tens of degrees $(^{\circ}C)$ in order not to disturb cell activities. Elementary spectroscopic studies to obtain plasma characteristics are presented for Ar and He plasma with different frequencies of RF power. Also the preliminary results of the micro plasma effects on G361 melanoma cells are presented. It was observed that the irradiation of micro plasma induces cell death through the deprivation of tyrosine phosphorylation in the G361 cells.

  • PDF