• 제목/요약/키워드: Plant control system

검색결과 2,997건 처리시간 0.033초

원자력발전소 디젤발전기 디지털 다중화 여자시스템 개발 및 적용 (The Development of Digital Excitation Control System for Diesel Generator of Nuclear Power Plant and Its Application)

  • 이주현;임익헌;신만수;정태원
    • 전기학회논문지
    • /
    • 제59권8호
    • /
    • pp.1449-1455
    • /
    • 2010
  • The excitation control system of an emergency diesel generator is classified as a kind of safety-related system. Compared with other control systems in a power plant, this system is required to be more reliable and have better performance. In this paper, the digital multi-redundant excitation system for a diesel generator was proposed. The signal processing system of the proposed system makes high speed signal processing and arithmetic in excitation control possible. The improved soft start algorithm and multiple PI parameters adaptation considering the diesel generator characteristics were implemented in the proposed system. The developed system was applied to a nuclear power plant successfully.

시화조력발전소 수차발전기 제어시스템의 동적 특성 해석 (Dynamic Characteristic Analysis of Water-Turbine Generator Control System of Sihwa Tidal Power Plant)

  • 안상지;반우현;박철원
    • 전기학회논문지P
    • /
    • 제61권4호
    • /
    • pp.180-185
    • /
    • 2012
  • Tidal power is one of new and renewable energy sources. The seawater is stored inside a tidal embankment built at the mouth of a river or bay, where tides ebb and flow. The water turbine-generators produce power by exploiting the gap in the water level between the water outside and inside the embankment. Tidal power plant is a large plant that is installed on the sea. And then, the facility's operations and a separate control system for monitoring and maintenance is required. However, this plant predictive control of building systems and technologies have been avoided the transfer of technology from advanced global companies. Accordingly, the control system for core technology development and localization is urgently needed. This paper presents modeling and simulation using by PSS/E about generator, governor, exciter, and power system stabilizer for control system in Sihwa tidal power plant to improve the efficiency and develope of core technology. And the dynamic characteristics of governor and exciter were analyzed.

자동 학습 퍼지 제어기를 이용한 발전용 보일러 시스템 제어에 관한 연구 (A Study on the Boiler System Control of Fossil-Power Plant Using a Self-organizing Fuzzy Logic Control)

  • 문운철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권11호
    • /
    • pp.514-519
    • /
    • 2001
  • This Paper presents an application of a on-line self-organizing fuzzy logic controller to a boiler system of fossil-power plant. A boiler-turbine system is described as a MIMO nonlinear system in this paper. Then, three single loop fuzzy logic controllers are designed independently. The control rules and the membership functions of proposed fuzzy logic control system are generated automatically without using plant model. The simulation shows successful results for wide range operation of boiler system of fossil-power plant.

  • PDF

적응제어를 이용한 유압 액츄에이터의 특성개선에 관한 연구 (A Study on the Characteristics Improvement of Fluid Power Actuator Using Adaptive Control)

  • 염만오;윤일로
    • 한국정밀공학회지
    • /
    • 제21권1호
    • /
    • pp.124-132
    • /
    • 2004
  • A hydraulic system is difficult to keep the performance due to non-linearity, load pressure which changes according to working condition and system parameter variation, the requirement of control algorithm has been risen in order to satisfy them. An adaptive control is a control method which is suggested to achieve a control object though plant characteristics change. In spite of the case that plant characteristics and the degree of variation are difficult to grasp, adaptive control can keep the characteristics of closed-loop system regularly. In this study GMVAC(generalized minimum variance adaptive control) combined with output error feedback is proposed in order to solve problems of non-minimum phase, vibration and overshoot in initial response of the plant. The control performance according to the variation of characteristics of the plant is evaluated by changing the supply pressure only.

Development of an Unmanned Control System of Induction Generator for a Wave Power Plant

  • Hwan, Jeon-Bong;Lim, Yong-Kon;Hong, Seok-Won
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.74.5-74
    • /
    • 2001
  • The wave power plant is a generating system to convert the wave energy resources to electric energy. ´CHUJEON A´, which is a prototype of wave power plant developed by KORDI(Korea Ocean Research and Development Institute), has been launched for its performance test. A wound rotor induction machine is adopted as a generator for the power plant to acquire constant frequency and voltage over wide range of rotor speed. Because the generator of ´CHUJEON A´ has no connection to the power grid line on land, all of the processes to generate and consume the electricity have to be conducted on the floating plant. This paper deals with the design and implementation of the unmanned control system for ´CHUJEON A´. The system includes generator control system, power conversion and charging system, data acquisition and wireless communication system ...

  • PDF

강진 UPFC Pilot Plant의 제어 범위 산정을 위한 계통 해석 (System Study for Decision of Control Limits of UPFC Pilot Plant in Korea)

  • 김학만;김종율;김정익;오태규;이학성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.53-55
    • /
    • 2002
  • This paper presents a part of system study results for UPFC Pilot Plant application in Korea. The system study includes control limits of UPFC Pilot Plant. Expansion of control limits is studied by coordination to switched shunt capacitors in local areas. The system study is simulated by PSS/E Ver 26.

  • PDF

계통주파수 제어를 위한 발전제어 특성개선 (The study of Line - frequency Control in performance improvement of plant Control system.)

  • 허성광;송성일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 정기총회 및 창립40주년기념 학술대회 학회본부
    • /
    • pp.114-117
    • /
    • 1987
  • This study is concerned with the improvement of the Automatic Boiler Control and Turbine Governor system to maintain line - frequency within $60{\pm}0.1\;HZ$. This describes the current problems of plant control system, the method, and equipments to be developed for each plant based on the experimental test were carried out at field, and, lastly, the results of the study with the progress of it.

  • PDF

발전소 제어시스템 기본 스테이션 기능 검증 (Functional Test of A Station of Control System for Power Plant)

  • 변승현;박두용;임익헌
    • 전자공학회논문지SC
    • /
    • 제48권4호
    • /
    • pp.25-32
    • /
    • 2011
  • 국내 전력의 수요증가로 인해 전력산업에서 신경망 역할을 하는 I&C(Instrumentation & Control)의 중요성이 날로 증가하고 있으며, 외국 선진 제작사의 기술 보호로 제어 시스템의 국산화가 요구되고 있는 상황이다. 이러한 상황에서 500MW급 초임계압 표준 석탄화력 발전소에의 실증 적용을 목표로 국산 통합 감시 제어시스템 개발 연구가 진행되고 있다. 개발하는 통합 감시 제어시스템은 발전설비의 중요성으로 인해 개발과정이나 개발 후 발전 설비에 적용되기 전에 시스템의 기능 및 신뢰성 등의 검증이 요구되고 있다. 또한 전력수요의 증가로 인해 제어시스템 설치 및 시운전 기간의 충분한 확보가 어려운 시점에서, 향후 실증 적용시 시행착오를 줄이기 위해 제어 시스템의 검증은 필수적이다. 본 논문에서는 개발한 제어 시스템의 기본 스테이션에 대해 기능 검증한 사례를 소개한다.

발전소 시뮬레이터 I/O 인터페이스 시스템 구축에 관한 연구 (An Implementation of I/O Interface System for Power Plant Simulator)

  • 변승현;장태인;조지용;곽귀일
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 하계종합학술대회 논문집
    • /
    • pp.773-776
    • /
    • 1999
  • For providing good quality power steadily, it is required that operators manipulate the control system of power plant with the good knowledge of power plant system and the control strategies, and cope with accidents effectively. With those requirements, it is general to train operators in power plant control room using full-scope simulator. A full scope simulator adopts the I&C instruments in the main cotrol room, so has to include I/O interface system to interface the simulation computer with I&C instruments in main control room. In already developed simulators, most of I/O interface systems are closed. vendor-dependent. proprietary systems. so have the many disadvantages in terms of cost and maintenance. In this paper. we suggest the method to configure I/O interface system for Thermal Power Plant Simulator based on standard technology which gives the advantages of ease-of-use. cost effectiveness, and simplicity of maintenanceuse by using off-the-shelf products for system integration.

  • PDF

Retrofit of Analog Boiler Control Systems with Digital Control Systems in a Thermal Power Plant

  • Park, Doo-Yong;Byun, Seung-Hyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1304-1308
    • /
    • 2005
  • This paper presents the case that the existing analog control systems were retrofitted with digital DCS(Distributed Control System)s for boiler unit in thermal power plant. Replacement of existing worn-out or obsolete analog control systems has been considered. Replacement of existing analog control systems with another analog control systems has lots of difficulties in maintaining the systems due to being out of stock. Due to those difficulties, existing analog control systems have been retrofitted with digital DCSs in many industrial sites. KEPRI(Korea Electric Power Research Institute) accomplished the project that retrofitted analog control systems with the developed DCSs for boiler unit in middle-scale coal-fired thermal power plant. The benefits of an upgrade to digital control include a increase of reliability due to system redundancy, ease of modifying the control logic and the parameters of function block, ease of maintenance due to available spare parts, improvement of information display, ease of modifying MMI(Man Machine Interface) displays, a increase in system availability, and improvement of control performance. This paper describes how to use the parameters of existing analog controllers, the implementation of digital PID controller, control system configuration for boiler unit in thermal power plant, some boiler control loops, control result during commissioning, and the comparison of boiler characteristic test data after retrofitting with the existing test data.

  • PDF