• 제목/요약/키워드: Plant Performance

검색결과 3,376건 처리시간 0.044초

강우자료 분석에 의한 소수력 발전소의 성능예측 (Performance Prediction of Small Hydropower Plant through Analyzing Rainfall Data)

  • 이철형;박완순;신동렬;정헌생
    • 태양에너지
    • /
    • 제9권3호
    • /
    • pp.81-91
    • /
    • 1989
  • This study represents the method to predict the flow duration curve and primary design specifications of small hydropower plant at hydropower site through analyzing the monthly rainfall data. Weibull distribution was selected to characterize the rainfall data and Thiessen method was used to calculate monthly average flowrate at site. Application of these results, primary design specifications such as design flowrate, annual average load factor and utility factor, annual average hydropower density and annual electric energy production were estimated and discussed for surveyed site located in Daigi-ri, Kangwon province. And performance characteristic model of small hydro-power plant was applied to estimate these specifications.

  • PDF

반포화 적분-비례제어기를 이용한 유도전동기의 속도제어 (Speed Control of Induction Motor Using Anti-windup Integral-Proportional Controller)

  • 정재호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.215-218
    • /
    • 2000
  • The windup phenomenon appears and degrades control performance when a controller with integrating action is used and the plant input is limited. An anti-windup integral -proportional(IP) controller is proposed for the variable-speed motor drives and it is experimentally applied to the speed control of a vector-controlled induction motor driven by a pulse width modulated (PWM) voltage source inverter(VSI). Although the operating conditions like motor load and speed command is changed under the limited plant input it is experimentally verified that the speed response has much improved performance such as no overshoot and fast settling time and the maximum plant input is also effectively utilized.

  • PDF

Analysis of the 6-gingerol Content in Zingiber spp. and their Commercial Foods using HPLC

  • Cho, Sunghun;Lee, Dong Gu;Lee, Sullim;Chae, Sungwook;Lee, Sanghyun
    • Journal of Applied Biological Chemistry
    • /
    • 제58권4호
    • /
    • pp.377-381
    • /
    • 2015
  • The content analysis of 6-gingerol, which is an active compound, in Zingiber spp. (Z. officinale and Z. mioga) and their commercial foods (ginger teas and powders) was conducted using high-performance liquid chromatography. A reverse phase system was used, with a gradient solvent system of water and acetonitrile. The 6-gingerol content was highest in the methanol extract of Z. officinale root (17.09 mg/g extract) and ginger powder B (15.92 mg/g extract). The results demonstrated that this method was simple and reliable for the quality control of Zingiber commercial foods.

발전기의 사고 시뮬레이션과 분석 (Fault Simulation and Analysis of Generator)

  • 박철원;오용택
    • 전기학회논문지P
    • /
    • 제62권3호
    • /
    • pp.151-158
    • /
    • 2013
  • Large generator of power plant is very important. In order to protect large generator from faults, digital protective relay or IED is required. However, all protective relays for generators of the domestic power plant are operated by foreign products. And now, for technological independence from foreign and improvement of import substitution effect, IEDs using domestic technology are being developed. To evaluate performance of developing next-generation power devices, the study of the dynamic characteristics of the power plant, generator system modeling, fault simulation and analysis, should be considered. Specially, To obtain IEEE Standards COMTRADE format for relay operation test, generator system modeling and fault simulation using PSCAD/EMTDC tools must be preceded. Until now, a complete modeling of generator internal windings and fault simulation techniques dose not exist. In this paper, for evaluation performance of relay elements of developing IED, the generator system modeling and various faults simulation using PSCAD/EMTDC tools were performed. And then, the various transient phenomena through obtained relaying signal of developed modeling were analyzed.

원자력 발전소 환경 디자인 설계를 위한 인체측정에 대한 연구 (Anthropometric Data Collection for MCR Environment Design of Nuclear Power Plant)

  • 차우창
    • 시스템엔지니어링학술지
    • /
    • 제6권1호
    • /
    • pp.47-52
    • /
    • 2010
  • Human Factors Engineering (HFE) for Main Control Room (MCR) of Nuclear Power Plant (NPP) has been applied to optimize the design and operation of Man-Machine Interface (MMI) between operators and their equipment in consideration of physical, psychological and cognitive aspects. However, it has been observed that operators complain about environmental discomfort in the MCR since the operators in the MCR experience excessive stress due to the environmental factors such as inappropriate interior and lighting system. Since the HFE is an essential factor for the high fidelity performance of operators in the MCR, the adequate MCR environment design with HFE rules and guidelines is as much important to enhance the operability and reliability of the MCRs. Therefore, there has been a strong need to design a pleasant environment for the MCR to improve human performance of the operators.

  • PDF

마이크로 컴퓨터를 이용한 소수력발전소 PID 조속기에 관한 연구 (A Study on the Microcomputer-based PID Governor for Small Hydro Power Plant)

  • 신동렬;이규현;이원용
    • 대한전기학회논문지
    • /
    • 제36권7호
    • /
    • pp.492-500
    • /
    • 1987
  • Microcomputer-based PID governor which can be provided either stability or rapid response for small hydro power plant at low cost is developed and adapted to the 5 KW model hydro power for the performance test. The effects of PID gains on stability boundaries of the hydraulic turbine generating system is investigated. For the optimum selection of the PID gains, general equations are derived on the base of the experiments. This control system has a good performance at the model of hydro power plant. For the prediction of the control system, a mathematical model was developed and the results of the simulation using this model was matched with the experimental results.

  • PDF

Evaluation of an Alarm System Using Signal Detection Theory(SDT)

  • Park, Jin-Kyun;Hong, Jin-Hyuk;Chang, Soon-Heung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(1)
    • /
    • pp.197-202
    • /
    • 1995
  • When the process disturbance of nuclear power plant occurred, the operator should ensure plant safety, economy and identify the causes of disturbance. To accomplish these goals, operator should process a large amounts of information. Among these, alarms would be often in the operator's first indication of a plant state change or disturbance. To support limited information processing capability of operator, considerable works are under way to develop advanced alarm processing systems and to evaluate it. However, conventional evaluation method could provide just evaluation results but the design alternatives to enhance alarm system performance. To overcome problems associated with conventional evaluation methods of alarm system, signal detection theory(SDT) was introduced, and it was possible conclude that SDT could not only evaluate system but also suggest design alternatives for performance enhancement.

  • PDF

수력발전소 자동제어설비 시험용 신호변환장치 개발에 관한 연구 (A Study on Development of Signal Conditioner for Test of Automatic Control Equipments in Hydro Power Plant)

  • 변두균;장문성;김주현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.169-171
    • /
    • 1995
  • Automatic control equipment in hydro power plant, such as turbine governor or automatic voltage regulator have to act promptly against for variation of power system, so it is necessary to check and test continuously. During last five years, the performance test of automatic control equipment was performed about 20 units of hydro turbine generator. In this process, because it has complex connection and before calibration, signal conditioner was developed as an auxiliary equipment for performance test. It includes function of signal amplifier, transducer, and meters. As a result of use this equipment for electric governor test at soyang-gang hydro power plant, it was possible to find output data equal to old one.

  • PDF

차량용 SRM의 가변속 구동을 위한 퍼지 제어기 설계 (Design of Fuzzy Logic Controller for a SRM Variable Speed Drive on Vehicle)

  • 송병섭;엄기명;윤용호;원충연;김덕근
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2000년도 학술대회논문집
    • /
    • pp.193-198
    • /
    • 2000
  • Switched reluctance motor drives have been finding their applications in the variable speed drives due to their relatively low cost, simple and robust structure, controllability and high efficiency. Fuzzy control does not need any model of plant. It is based on plant operator experience and heuristics. Fuzzy control is basically adaptive and gives robust performance for plant parameter variation. This paper deals with the sped control of switched reluctance motor using fuzzy controller with 7-rule based fuzzy logic. The proposed fuzzy controller is superior to the control performance of the conventional PI controller. The fuzzy controller is implemented by 80C196KC, 16 bit one-chip microcontroller.

  • PDF

A Design Method of Model Following Control System using Neural Networks

  • Nagashima, Koumei;Aida, Kazuo;Yokoyama, Makoto
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.485-485
    • /
    • 2000
  • A design method of model following control system using neural networks is proposed. An unknown nonlinear single-input single-output plant is identified using a multilayer neural networks. A linear controller is designed fer the linear approximation model obtained by linearinzing the identification model. The identification model is also used as a plant emulator to obtain the prediction error. Deficient servo performance due to controlling nonlinear plant with only linear controller is mended by adjusting the linear controller output using the prediction output and the parameters of the identification model. An optimal preview controller is adopted as the linear controller by reason of having good servo performance lowering the peak of control input. Validity of proposed method is illustrated through a numerical simulation.

  • PDF