• 제목/요약/키워드: Plant Facilities

검색결과 938건 처리시간 0.053초

제주시 폐기물환경사업소의 미활용에너지 활용방안 연구 (A Study on Unused Energy Management of Jeju City Waste Environment Center)

  • 김상혁;권기린;박윤철
    • 동력기계공학회지
    • /
    • 제8권1호
    • /
    • pp.48-54
    • /
    • 2004
  • In this study, waste heat of Jeju City Waste Environment Center is investigated and the utilization method is suggested with economical analysis of additional investment that needed for new facility. Energy balance of the typical facilities is considered in this study such as incineration plant and LFG power plant. The payback period of the investment which is used for the LFG power plant waste heat utilization facility is about 2.4 years and the economic profit of the facility during 10 years operation is up to 926 million won.

  • PDF

대규모 해수담수화 플랜트에서의 전처리공정 비용 분석 (Cost comparison of pretreatment processes in large SWRO desalination plant)

  • 김영민;김진호;이상호;이창규;박광덕;최준석
    • 상하수도학회지
    • /
    • 제27권5호
    • /
    • pp.555-560
    • /
    • 2013
  • A cost analysis method for pretreament processes of a large scale seawater desalination plant was considered using a cost estimation model, WaTER (Water Treatment Estimation Routine). This model is based on cost functions of U.S. EPA to conduct economic analysis of water treatment facilities. A virtual seawater desalination plant which has pretreatment production capacity of $100,000m^3$ per day was chosen as a model plant. Dual media filtration and microfiltration systems were compared as pretreatment process, and the following reverse osmosis process was modeled. As a result, microfiltration showed a price competitiveness in condition of operating with reverse osmosis process by reducing the loads of water treatment and membrane cleaning despite it's high annual cost.

Assessment of environmental impacts of LID technologies on vegetation

  • Choi, Hyeseon;Hong, Jungsun;Geronimo, F.K.F.;Kim, Lee-Hyung
    • Membrane and Water Treatment
    • /
    • 제10권1호
    • /
    • pp.39-44
    • /
    • 2019
  • LID facilities do not consider environmental factors, and due to inappropriate vegetation planting causing degradation in efficiency due to plant damage and difficulty in maintenance. Therefore, in this study, assessment of impact environmental factor by seasonal variation of chlorophyll and growth of vegetation planted in LID technologies and change of pollutant reduction were conducted. In the case of B-SJ and B-RI, growth rate decreased after summer (August), and B-MG showed steady growth until autumn (September). Chlorophyll was found to increase during spring season while it decreased during autumn season. The chlorophyll concentration was found to affect the plant growth pattern. TN reduction efficiency was highest with greater than 80% efficiency in summer, and it was analyzed that plants were identified as the main factor affecting the seasonal reduction efficiency of TN. Also, temperature and relative humidity were analyzed to affect plant growth, activity and pollutant removal efficiency. Plant type and growth pattern are considered as factors to be considered in selection of appropriate plant types in LID technologies.

A Quantity Prediction Model for Reinforced Concrete and Bricks in Education Facilities Using Regression Analysis

  • Lee, Jong-Kyun;Kim, Boo-Young;Kim, Jang-Young;Kim, Tae-Hui;Son, Kiyoung
    • 한국건축시공학회지
    • /
    • 제13권5호
    • /
    • pp.506-512
    • /
    • 2013
  • Since the amendment of the law on the private sector investment in social infrastructure in January of 2005, the government has been actively promoting Build-Transfer-Lease (BTL) projects. Notably, most new educational facilities have been built as BTL projects. For these facilities, the unit cost per unit area has been applied to predict construction costs. However, since construction costs are mostly managed after the detailed design phase, the costs can be estimated incorrectly. For this reason, cost management is needed in the planning phase, with a sound approximate estimate to prevent the wasteful use of funds. To address this shortcoming, this study aims to develop a quantity prediction model for education facilities using regression analysis in the planning phase. The developed model is focused on the required quantities of reinforced concrete and bricks. In order to achieve the objective, the data of 44 educational facility projects collected from Gyeonggi-do was used in the regression model. This study can be utilized by major stakeholders to accurately predict construction costs by estimating the appropriate quantities of reinforced concrete and bricks in the planning design phase.

제주지역 빗물이용시설의 효율적 개선방안 연구 (A Study on Efficient Improvement Method of Rainwater Utilization Facilities in Jeju Island)

  • 박원배;문덕철;고기원
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제17권6호
    • /
    • pp.1-8
    • /
    • 2012
  • This study is to suggest a few efficient ways of rainwater utilization, through monitoring and analyzing 143 rainwater storage systems and 110 artificial recharge systems, which are installed in the recommended facilities by law, among the rainwater harvesting systems in Jeju Island. In the case that catchment facilities are damaged, rainwater could be contaminated by leaves and debris so that the rates of rainwater usages come to be lower. It is possible that contaminated rainwater could contaminate artificial recharge wells or rainwater discharging out of the rainwater harvesting system could result in flood and damage for the downgradient area. For maintaining high quality of rainwater and increasing rainwater utilization rate, it is necessary to install screening facilities and purification plant functioning precipitation and filtration. Also, in order to efficiently preclude the overflowing rainwater exceeding storage capacity, it is recommended to associate rainwater storage tanks with artificial recharge well or infiltration trench facilities.

저류지 생태공원 설계모형 개발에 관한 연구 (A Study on the Development of Design Model of Ecological Park as Stormwater Storage Facilities)

  • 변우일
    • 한국환경복원기술학회지
    • /
    • 제9권3호
    • /
    • pp.1-16
    • /
    • 2006
  • The purpose of this study is to develop design model of ecological park as stormwater storage facilities. The results are as follows : First, the design model of ecological park as stormwater storage facilities consider ecological and landscape characteristics such as high efficiency of land use, function as disaster prevention, ecological water purification, formation of habitat for flora and fauna. Second, this study demonstrates two types of plane structure and eight types of designed section. They can be combined and designed depending on conditions of each site. The facilities of stormwater storage conduct disaster prevention system and ecological park. Retention pond in stormwater storage facilities for ecological park also should be made for ecological restoration in the site. Third, the ecological park provide the basis for ecological network from in-site to out-site. Therefore its conservation and restoration plan consider the ecosystems of the site. Fourth, the most important factor for maintenance and management for retention pond is keeping water quality. Sustainable Structured wetland Biotop system is suggested for ecological water purification system in the retention pond which is one of the constructed wetland system using multi-celled aquatic plant and pond. This system can also provide habitat for animals and plants, water friendly park for men, and beautiful landscape.

비용편익 분석에 기초한 공동구의 경제적 타당성 평가 (Economic Feasibility of Common Utility Tunnel based on Cost-Benefit Analysis)

  • 강영구;최익창
    • 한국안전학회지
    • /
    • 제30권5호
    • /
    • pp.29-36
    • /
    • 2015
  • Common utility tunnel is essential to the daily lives of people underground utilities (electricity, gas and supply facilities such as water, communication facilities, sewer facilities, etc.) to improve the appearance by co-acceptance and disaster prevention, important for the conservation of the city's population was concentrated road construction the city-based facilities. There is recognition of the importance of the various supply treatment facilities in common utility tunnel as infrastructure to accommodate joint according to the city expanded, the demand for infrastructure. In this paper, a cost-benefit analysis using a one-time occurrence, without simply relying on cost or current cost, project manager for the city-dimensional feasibility study conducted, the user level of the maintenance costs and user costs, including social costs items from various angles can be investigated and proposed a mechanism of economic feasibility common utility tunnel. Evaluation of the proposed technique is cost-benefit and cost caused by installing common utility tunnel the existing pipeline area - was investigated by the benefit analysis, extended and repeated common utility tunnel installation depends much affected by the excavation, so users of reducing the number of repeat excavation convenience can be seen that this occurs.

대구시 산업단지 환경기초시설의 악취발생 특성 (Emission Characteristics of Odor Compounds from Fundamental Environmental Facilities in an Industrial Complex Area in Daegu City)

  • 이찬형;전현숙;신명철;김은덕;장윤재;권병윤;송희봉
    • 한국환경보건학회지
    • /
    • 제42권4호
    • /
    • pp.246-254
    • /
    • 2016
  • Objectives: This study evaluated the odor emission characteristics from fundamental environmental facilities at an industrial complex area in Daegu City. Methods: The odor samples were collected from May 2015 to January 2016 and were analyzed for specified offensive odor substances. The odor quotient and the odor contribution was calculated. Results: Ammonia was detected in all samples monitoring specified odor compounds, followed by hydrogen sulfide and acetaldehyde. According to contribution analysis, hydrogen sulfide shows the highest contribution in all facilities. At wastewater treatment plants A and B and sewage treatment plant F, it was followed by acetaldehyde. At wastewater treatment plant C, it was followed by imethyl sulfide. Conclusion: The major component of odor can be determined by evaluating the degree of contribution to the odor intensity rather than the concentration of the individual odor components. To increase the effectiveness of odor reduction, policies focused on materials with a high odor contribution are needed rather than focusing on high-concentration odor compounds.

비균열 콘크리트에 매립된 발전설비 정착부 선 설치 앵커의 구조성능 평가 (Performance Evaluation of the Cast-in-place Anchor Bolt in Non-cracked Concrete used in Power Plant Facilities)

  • 김동익;정우영
    • 한국산학기술학회논문지
    • /
    • 제20권11호
    • /
    • pp.250-258
    • /
    • 2019
  • 과거 지진 발생으로 인하여 발전소 내 전력 운용설비의 전도로 인한 피해가 크게 발생하여 이에 대한 국내 발전소 운용설비 정착부에 대한 내진 안정성 평가는 매우 중요하다. 본 연구에서는 현재 국내 발전소 내 설치된 발전설비 현장조사를 통하여 콘크리트 슬래브에 설치된 발전설비 정착부 앵커볼트의 구조성능을 평가하였다. 대상구조물인 대청댐의 경우, 고정부 설치용으로 선 설치 앵커볼트가 사용되었으며 규격은 M10 J형 선설치 앵커볼트와 M12 J형 선설치 앵커볼트로 시공되었다. ASTM E 488-96 기준을 고려하여 앵커볼트 인발 및 전단 성능평가를 수행하였으며 평가된 앵커볼트의 성능을 국내외 설계기준(KCI 2012, ACI 318, EOTA TR45)과 비교, 분석하였다. 그 결과 M10, M12 J형 선설치 앵커볼트들은 모두 설계하중 값보다 높게 저항하는 것으로 나타나 현재 시공 상태가 설계기준은 충분히 만족하다는 결과를 얻었다. 하지만 이는 실험적 평가를 통한 결과일 뿐이므로 향후 수치해석 평가를 통하여 보다 폭넓게 분석될 필요가 있을 것으로 판단된다.

제주 시설온실 냉난방을 위한 발전소 온배수 활용 열펌프 시스템 구축 및 냉방성능 평가 (Construction of the Heat Pump System Using Thermal Effluents for Greenhouse Facilities in Jeju and Evaluation of Cooling Performance)

  • 이연건;허재혁;이동원;현명택
    • 에너지공학
    • /
    • 제27권4호
    • /
    • pp.70-79
    • /
    • 2018
  • 한국중부발전 제주화력본부에서 방류되는 온배수로부터 열원을 회수하여 약 3 km의 원거리에 위치하고 있는 신촌백합영농조합법인의 시설온실에 냉온수를 공급하기 위한 300 RT 용량의 열펌프 시스템을 구축하였다. 원거리 시설로 온배수열을 공급하기 위한 최적화 방안을 도출하였고, 수송관로의 온도와 누수여부를 모니터링하기 위한 설비들이 설치되었다. 본 논문에서는 제주 시설온실 냉난방을 위한 발전소 온배수 활용 열펌프 시스템의 구성과 주요기기에 대해 기술하였다. 2018년 하절기에 열펌프 시스템의 냉방성능을 평가하기 위한 실증운전을 수행하였다. 냉방운전 시 열펌프 시스템의 주요 위치에서 측정된 유체의 온도와 유량, 그리고 냉방 성능계수를 분석하여, 구축된 열펌프 시스템의 안정성과 냉방성능을 검증하였다.